980 resultados para Tip


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present work we consider two aspects of the deposition of metal clusters on an electrode surface. The formation of such clusters with the tip of a scanning tunneling microscope is simulated by atom dynamics. Subsequently the stability of these clusters is investigated by Monte Carlo simulations in a grand-canonical ensemble. In particular, the following systems were considered explicitly: Pd clusters on Au(111), Cu on Au(111), Ag on Au(111), Pb on Au(111) and Cu on Ag(111). The analysis of the results obtained for the different systems leads to the conclusion that optimal systems for nanostructuring are those where the metals participating have similar cohesive energies and negative heats of alloy formation. In this respect, the system Cu-Pd(111) is predicted as a good candidate for the formation of stable clusters. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Palladium clusters have been deposited on the surface of a Au(111) electrode with the tip of a scanning tunnelling microscope. The distance over which the tip was moved towards the surface has a decisive influence on the properties of the clusters: the larger this distance, the larger the generated clusters, and the more stable they are. These findings are supported by computer simulations, which further suggest that the larger clusters contain a sizable amount of gold, which enhances their stability. Dissolution of the clusters occurs from the edges rather than layer by layer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The properties of palladium clusters, generated with the electrochemical scanning tunneling microscope, have been investigated both by experiments and by computer simulations. The clusters are found to be larger and more stable if the tip is moved further towards the electrode surface in the generation process. The simulations suggest that the larger clusters consist of a palladium - gold mixture, which is more stable than pure palladium. Dissolution of the clusters occurs from the edges rather than layer by layer

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Liquid droplets suspended by the tip of a thin wire, a glass capillary, or a needle form high-Q optical resonators, thanks to surface tension. Under gravity equilibrium conditions, the maximum drop diameter is approximately 1.5 mm for paraffin oil (volume ∼ 0.5 μL) using, for instance, a silica fiber with 250 μm thickness. Whispering gallery modes are excited by a free-space near-infrared laser that is frequency locked to the cavity resonance. The droplet cavity serves as a miniature laboratory for sensing of chemical species and particles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An extensive experimental program has been carried out on a 135?mm tip diameter radial turbine using a variety of stator designs, in order to facilitate direct performance comparisons of varying stator vane solidity and the effect of varying the vaneless space. A baseline vaned stator was designed using commercial blade design software, having 15 vanes and a vane trailing edge to rotor leading edge radius ratio (Rte/rle) of 1.13. Two additional series of stator vanes were designed and manufactured; one series having varying vane numbers of 12, 18, 24, and 30, and a further series with Rte/rle ratios of 1.05, 1.175, 1.20, and 1.25. As part of the design process a series of CFD simulations were carried out in order to guide design iterations towards achieving a matched flow capacity for each stator. In this way the variations in the measured stage efficiency could be attributed to the stator passages only, thus allowing direct comparisons to be made. Interstage measurements were taken to capture the static pressure distribution at the rotor inlet and these measurements were then used to validate subsequent numerical models. The overall losses for different stators have been quantified and the variations in the measured and computed efficiency were used to recommend optimum values of vane solidity and Rte/rle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gold is the optimal tip metal for light emission in scanning tunnelling microscopy (LESTM) under ambient conditions. Sharp Au-tips of similar to 10nm radius were produced reliably using a safe, two-step etching method in 20% (w/w) CaCl2 solution. Previous CaCl2-based methods have tended to produce blunter tips, while other etching techniques that do produce sharp Au-tips, do so with the use of toxic or hazardous electrolytes. The tips are characterised using scanning electron microscopy and their efficacy in LESTM is evidenced by high-resolution, simultaneous topographic and photon mapping of Au(1 1 1)- and polycrystalline Au-surfaces. Spectra of the optical emission exhibit only one or two peaks with etched tips in contrast to the more complex spectra typical of cut tips; this feature, together with the highly symmetric geometry of the tips, facilitates a definitive analysis of the light emission process. (c) 2007 Elsevier B. V.. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The string mode of operation for an electron beam ion source uses axially oscillating electrons in order to reduce power consumption, also simplifying the construction by omitting the collector with cooling requirements and has been called electron string ion source (ESIS). We have started a project (supported by INTAS and GSI) to use Schottky field emitting cathode tips for generating the electron string. The emission from these specially conditioned tips is higher by orders of magnitude than the focused Brillouin current density at magnetic fields of some Tesla and electron energies of some keV. This may avoid the observed instabilities in the transition from axially oscillating electrons to the string state of the electron plasma, opening a much wider field of possible operating parameters for an ESIS. Besides the presentation of the basic features, we emphasize in this paper a method to avoid damaging of the field, emission tip by backstreaming ions. (C) 2008 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Demographic ageing is a global phenomenon. UK policy and research have, until recently, focused on national trends and implications and largely viewed ageing as a 'pensions and care' problem. While other and more positive aspects are beginning to be acknowledged, regional, local, and rural impacts remain underinvestigated. This paper, by reviewing the literature from several disciplines and countries, introduces a series of research questions that could usefully inform future geographical inquiry. It argues that the nature, experiences, and consequences of demographic ageing will vary across space, stage in the life course and numerous aspects of our everyday lives. Our current knowledge and understanding are but the tip of the iceberg in terms of the research opportunities that lie ahead.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes an investigation of various shroud bleed slot configurations of a centrifugal compressor using CFD with a manual multi-block structured grid generation method. The compressor under investigation is used in a turbocharger application for a heavy duty diesel engine of approximately 400 hp. The baseline numerical model has been developed and validated against experimental performance measurements. The influence of the bleed slot flow field on a range of operating conditions between surge and choke has been analysed in detail.
The impact of the returning bleed flow on the incidence at the impeller blade leading edge due to its mixing with the main through-flow has also been studied. From the baseline geometry, a number of modifications to the bleed slot width have been proposed, and a detailed comparison of the flow characteristics performed. The impact of slot variations on the inlet incidence angle has been investigated, highlighting the improvement in surge and choked flow capability. Along with this, the influence of the bleed slot on stabilising the blade passage flow by the suction of the tip and over-tip vortex flow by the slot has been considered near surge.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We simulate the localized surface plasmon resonances of an Au nanoparticle within tunnelling proximity of an Au substrate. The results demonstrate that the calculated resonance energies can be identified with those experimentally detected for light emission from the tip-sample junction of a scanning tunnelling microscope. Relative to the modes of an isolated nanoparticle these modes show significant red-shifting, extending further into the infrared with increasing radius, primarily due to a proximity-induced lowering of the effective bulk plasmon frequency. Spatial mapping of the field enhancement factor shows an oscillatory variation of the field, absent in the case of a dielectric substrate; also the degree of localization of the modes, and thus the resolution achievable electromagnetically, is shown to depend primarily on the nanoparticle radius, which is only weakly dependent on wavelength.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electromagnetic radiation originating with localized surface plasmons in the metal-tip/metal-sample nanocavity of a scanning tunneling microscope is demonstrated to extend to a wavelength lambda of at least 1.7 mu m. Progressive spectral extension beyond lambda similar to 1.0 mu m occurs for increasing tip radius above similar to 15 nm, reaching lambda similar to 1.7 mu m for tip radius similar to 100 nm; these observations are corroborated by use of a simple physical model that relates the discrete plasmon mode frequencies to the tip radius. This spectral extension opens up a new regime for scanning tunneling microscope-based optical spectroscopy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Scanning tunnelling microscope (STM) tip-induced light emission from Au and Ag has been studied. Thin film samples similar to100nm thick were prepared by thermal evaporation at 0.5nm/s onto a room-temperature glass substrate to produce grains of 20-50nm in lateral dimension at the surface. Light emission from the samples in the STM was quasi-simultaneously recorded with the topography, at 1.8V tip bias and 3-40nA current, alternating pixel by pixel at the same bias. Typically, a surface scan range of 150 nm x 150 nm was surveyed. Au, W and PtIr tips were used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The formation of chemically etched fibre tips for use in optical scanning probe microscopy is addressed. For tips formed at a cleaved fibre end in the bulk of a buffered HF acid solution the morphological features (tip height, cone angle) are found to depend strongly on the temperature and etchant composition. The tip formation process is analysed and explained in terms of a simple model in which the only pertinent physical parameters are the fibre core diameter and etch rates of the fibre core and cladding. The etch rates are determined in separate experiments as a function of temperature (in the range 24-50 degreesC) for etchant solutions of de ionised water: 50% HF acid: 40% NH4F in the volume ratio 1 : 1 : X for X=2, 4 and 6, and used in the model to yield a correct description of the experimental tip cone angles. The model is successfully extended to the intriguing case of negative tip formation which initiates in a normal, positive tip structure. By contrast, tip formation in the meniscus region of a bare fibre/etchant/organic solvent system is found to be independent of etchant composition and temperature. (C) 2000 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The interaction of an ultraintense laser pulse with a conical target is studied by means of numerical particle-in-cell simulations in the context of fast ignition. The divergence of the fast electron beam generated at the tip of the cone has been shown to be a crucial parameter for the efficient coupling of the ignition laser pulse to the precompressed fusion pellet. In this paper, we demonstrate that a focused hot electron beam is produced at the cone tip, provided that electron currents flowing along the surfaces of the cone sidewalls are efficiently generated. The influence of various interaction parameters over the formation of these wall currents is investigated. It is found that the strength of the electron flows is enhanced for high laser intensities, low density targets, and steep density gradients inside the cone. The hot electron energy distribution obeys a power law for energies of up to a few MeV, with the addition of a high-energy Maxwellian tail.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stress analysis of the cement fixation of orthopaedic implants to bone is frequently? carried out using finite element analysis. However, the stress distribution in the cement laver is usually intricate, and it is difficult to report it in a way that facilitates comparison of implants for pre-clinical testing. To study this problem, and make recommendations for stress reporting, a finite element analysis of a hip prosthesis implanted into a synthetic composite femur is developed. Three cases are analyzed: a fully bonded implant, a debonded implant, and a debonded implant where the cement is removed distal to the stein tip. In addition to peak stresses, and contour and vector plots, a stressed volume and probability-of-failure analysis is reported. It is predicted that the peak stress is highest for the debonded stem, and that removal of the distal cement more than halves this peak stress. This would suggest that omission of the distal cement is good for polished prostheses (as practiced for the Exeter design). However; if the percentage of cement stressed above a certain threshold (say 3 MPa) is considered, then the removal of distal cement is shown to be disadvantageous because a higher volume of cement is stressed to above the threshold. Vector plots clearly demonstrate the different load transfer for bonded and debonded prostheses: A bonded stein generates maximum tensile stresses in the longitudinal direction, whereas a debonded stem generates most tensile stresses in the hoop direction, except near the tip where tensile longitudinal stresses occur due to subsidence of the stein. Removal of the cement distal to the tip allows greater subsidence but alleviates these large stresses at the tip, albeit at the expense of increased hoop stresses throughout the mantle. It is concluded that a thorough analysis of cemented implants should not report peak stress, which can be misleading, but rather stressed volume, and that vector plots should be reported if a precise analysis of the load transfer mechanism is required.