974 resultados para Thrust curve


Relevância:

10.00% 10.00%

Publicador:

Resumo:

10th Conference on Telecommunications (Conftele 2015), Aveiro, Portugal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO - Os autores relatam a transição da etapa de retenção para a etapa de mitigação da Gripe A (H1N1), de acordo com a experiência portuguesa. Admitem que a curva epidémica da gripe poderia ser atrasada, mas não contida exactamente. A linha divisória entre os casos importados e os casos com origem em Portugal esteve na base da decisão de passar para a etapa de mitigação. ----------------- ---------ABSTRACT – The authors report the transition from the containment phase into the mitigation one, according to the Portuguese experience. They further admit that the epidemic flu curve could be delayed, but not exactly contained. The cross line between the imported cases and those generated in Portugal supported the decision to step forward into the mi

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Workshop on ns-3 (WNS '15). 13, May, 2015. Castelldefels, Spain.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: We set out to evaluate whether changes in N-terminal pro-brain natriuretic peptide (proBNP) can predict changes in functional capacity, as determined by cardiopulmonary exercise testing (CPET), in patients with chronic heart failure (CHF) due to dilated cardiomyopathy (DCM). METHODS: We studied 37 patients with CHF due to DCM, 81% non-ischemic, 28 male, who performed symptom-limited treadmill CPET, with the modified Bruce protocol, in two consecutive evaluations, with determination of proBNP after 10 minutes rest prior to CPET. The time between evaluations was 9.6+/-5.5 months, and age at first evaluation was 41.1+/-13.9 years (21 to 67). RESULTS IN THE FIRST AND SECOND EVALUATIONS RESPECTIVELY WERE: NYHA functional class >II 51% and 16% (p<0.001), sinus rhythm 89% and 86.5% (NS), left ventricular ejection fraction 24.9+/-8.9% and 26.6+/-8.6% (NS), creatinine 1.03+/-0.25 and 1.09+/-0.42 mg/dl (NS), taking ACE inhibitors or ARBs 94.5% and 100% (NS), beta-blockers 73% and 97.3% (p<0.001), and spironolactone 89% and 89% (NS). We analyzed the absolute and percentage variation (AV and PV) in peak oxygen uptake (pVO2--ml/kg/min) and proBNP (pg/ml) between the two evaluations. RESULTS: (1) pVO2 AV: -17.4 to 15.2 (1.9+/-5.7); pVO2 PV: -56.1 to 84% (11.0+/-25.2); proBNP AV: -12850 to 5983 (-778.4+/-3332.5); proBNP PV: -99.0 to 379.5% (-8.8+/-86.3); (2) The correlations obtained--r value and p value [r (p)]--are shown in the table below; (3) We considered that a coefficient of variation of pVO2 PV of >10% represented a significant change in functional capacity. On ROC curve analysis, a proBNP PV value of 28% showed 80% sensitivity and 79% specificity for pVO2 PV of >10% (AUC=0.876, p=0.01, 95% CI 0.75 to 0.99). CONCLUSIONS: In patients with CHF due to DCM, changes in proBNP values correlate with variations in pVO2, as assessed by CPET. However, our results suggest that only a proBNP PV of >28% predicts a significant change in functional capacity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Metabolic syndrome (MS) is associated with increased incidence of diabetes and atherosclerotic complications. The new definition of the International Diabetes Federation (IDF) increases the population with this entity, compared to the NCEP ATP III definition. OBJECTIVES: To study the prevalence of coronary artery disease (CAD) and carotid intima-media thickness (IMT) in patients with and without MS, according to the NCEP ATP III and IDF definitions, and the predictive ability of carotid IMT for CAD. METHODS: We studied 270 consecutive patients admitted for elective coronary angiography due to suspicion of CAD. All patients underwent ultrasound study of the carotid arteries to measure IMT (the highest value between the right and left common carotid arteries was used in the analysis). Coronary stenosis of > or =70% (or 50% for the left main coronary artery) was considered significant. RESULTS: By the ATP III definition, 14% of the patients had MS, and these patients had a higher prevalence of CAD (87% vs. 63%, p = 0.004), but no significant difference was found for carotid IMT (1.03 +/- 0.36 mm vs. 0.95 +/- 0.35 mm, p=NS). With the IDF definition, 61% of the patients had MS; this group was slightly older and included more women. There were no differences in terms of CAD (68% vs. 63%) or carotid IMT (0.97 +/- 0.34 vs. 0.96 +/- 0.39 mm). On multivariate analysis, the ATP III definition of MS predicts CAD (OR 4.76, 95% CI 1.71-13.25, p = 0.003), but the IDF definition does not (OR 1.29, 95% CI 0.74-2.27, p = 0.37). On ROC curve analysis, an IMT of > or = 0.95 mm predicts CAD (AUC 0.66, p < 0.001), with a sensitivity of 52% and specificity of 75%. CONCLUSIONS: The new IDF definition increases the population with MS, decreasing the capacity to predict the presence of CAD. In our population, neither the ATP III nor the IDF definition showed differences in terms of carotid IMT. Carotid IMT can predict CAD, but with only modest sensitivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

GOALS OF WORK: Recent literature has indicated the need for rapid evaluation of psychosocial issues secondary to cancer. Because of the problems of routine use of psychometric instruments, short instruments such as visual analogue scales or one-item 0-10 scales have been developed as valid assessment alternatives. PATIENTS AND METHODS: A study was conducted to examine the role of two 0-10 scales in measuring emotional stress (distress thermometer, DT) and depressed mood (mood thermometer, MT), respectively, in a multicenter study carried out in southern European countries (Italy, Portugal, Spain, and Switzerland). A convenience sample of 312 cancer outpatients completed the DT and MT and the Hospital Anxiety Depression Scale (HADS). MAIN RESULTS: DT was more significantly associated HADS anxiety than HADS depression while MT was related both to HADS anxiety and depression. The correlation of MT with HADS was higher than DT. A cutoff point >4 on the DT maximized sensitivity (65%) and specificity (79%) for general psychosocial morbidity while a cutoff >5 identified more severe "caseness" (sensitivity=70%; specificity=73%). On the MT, sensitivity and specificity for general psychosocial morbidity were 85% and 72% by using the cutoff score >3. A score >4 on the MT was associated with a sensitivity of 78% and a specificity of 77% in detecting more severe caseness. CONCLUSIONS: Two simple instruments, the DT and the MT, were found to have acceptable levels of sensitivity and specificity in detecting psychosocial morbidity. Compared to the HADS, however, the mood MT performed better than the DT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The introduction of new procedures in surgery usually implies the costs of the so called learning curve. However patients should not suffer the negative effects of surgeon's learning curves. We report our results with the first 15 Ross procedures, a single surgeon and institution experience, and how it was possible to build a safe learning curve without major consequences for the patients. We emphasize the need for a continuous program of surgical performance assessment throughout the learning curve period, as was demonstrated in our series.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho consiste no projeto, desenvolvimento e implementação de uma máquina voadora de inspiração biológica. Para a sua construção, é elaborado um estudo do voo nos seres biológicos de forma a obter alguma informação para o seu dimensionamento e é elaborada uma análise de projetos que utilizem as mesmas características de voo. Com os dados recolhidos neste estudo, é elaborado o projeto da máquina. Numa última fase, com recurso a materiais leves, é implementada uma máquina capaz de exercer as forças envolvidas no voo, força de propulsão e força de sustentação, e são elaborados estudos a fim de perceber quais os pontos fortes e os pontos fracos da mesma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Desde sempre o Homem procurou automatizar tarefas repetitivas. Tanto na indústria como no sector doméstico ou de comércio estão constantemente a surgir novos equipamentos procurando aumentar o nível de automação de diversas tarefas. A necessidade de empresas criadoras de produtos inovadores se manterem concorrenciais obrigou à adopção de métodos de projecto e planeamento mais estruturados e eficientes que eliminem os desperdícios tanto de material como de tempo. Diversas construções em termos orçamentais e o aumento da procura de produtos de alta qualidade a baixo custo deu origem a um novo tipo de programas, os programas de simulação virtual. Tal como na indústria, também na investigação nas Instituições de Ensino Superior se procuram adoptar os métodos de trabalho mais eficientes possíveis. Uma parte dos programas de simulação robótica utilizados hoje em dia na investigação no Instituto Superior de Engenharia do Porto estão concebidos em linguagem C. Embora esta linguagem seja extremamente capaz, existem métodos mais adequados de simulação que aceleram o processo de modelação permitindo a visualização do movimento e simulação de diversas situações potencialmente criticas sem existir a necessidade de construção de um protótipo funcional do robô. Durante o último ano, este projecto permitiu construir um modelo de um robô quadrúpede num programa de simulação virtual chamado Simmechanics™. Embora haja já algum trabalho desenvolvido nesta área, constatou-se que a informação existente possuía algumas lacunas. Com o trabalho desenvolvido preparou-se esta dissertação que pretende clarificar algumas questões que surgem na modelação de um robô. Neste documento explica-se como modelar um robô de corpo flexível, modelar as pernas e as respectivas juntas da anca e do joelho assim como também se apresenta a modelação de um contacto com o solo recorrendo a um modelo descrito na literatura. Este documento foi escrito a pensar no leitor, procurando-se explicar de forma simples mas concisa os diversos passos necessários para construir um modelo virtual de um robô. O autor espera, desta forma, ajudar futuros colegas que pretendam trabalhar com o Simmechanics™ a mais facilmente se integrarem com o programa aumentando desta forma o declive da curva de aprendizagem e permitindo um maior aproveitamento desta ferramenta.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study a citrate-buffered version of QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method for determination of 14 organochlorine pesticides (OCPs) residues in tamarind peel, fruit and commercial pulp was optimized using gas chromatography (GC) coupled with electron-capture detector (ECD) and confirmation by GC tandem mass spectrometry (GC–MS/MS). Five procedures were tested based on the original QuEChERS method. The best one was achieved with increased time in ultrasonic bath. For the extract clean-up, primary secondary amine (PSA), octadecyl-bonded silica (C18) and magnesium sulphate (MgSO4) were used as sorbents for tamarind fruit and commercial pulp and for peel was also added graphitized carbon black (GCB). The samples mass was optimized according to the best recoveries (1.0 g for peel and fruit; 0.5 g for pulp). The method results showed the matrix-matched calibration curve linearity was r2 > 0.99 for all target analytes in all samples. The overall average recoveries (spiked at 20, 40 and 60 μg kg−1) have been considered satisfactory presenting values between 70 and 115% with RSD of 2–15 % (n = 3) for all analytes, with the exception of HCB (in peel sample). The ranges of limits of detection (LOD) and quantification (LOQ) for OCPs were for peel (LOD: 8.0–21 μg kg−1; LOQ: 27–98 μg kg−1); for fruit (LOD: 4–10 μg kg−1; LOQ: 15–49 μg kg−1) and for commercial pulp (LOD: 2–5 μg kg−1; LOQ: 7–27 μg kg−1). The method was successfully applied in tamarind samples being considered a rapid, sensitive and reliable procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The adhesive bonding technique enables both weight and complexity reduction in structures that require some joining technique to be used on account of fabrication/component shape issues. Because of this, adhesive bonding is also one of the main repair methods for metal and composite structures by the strap and scarf configurations. The availability of strength prediction techniques for adhesive joints is essential for their generalized application and it can rely on different approaches, such as mechanics of materials, conventional fracture mechanics or damage mechanics. These two last techniques depend on the measurement of the fracture toughness (GC) of materials. Within the framework of damage mechanics, a valid option is the use of Cohesive Zone Modelling (CZM) coupled with Finite Element (FE) analyses. In this work, CZM laws for adhesive joints considering three adhesives with varying ductility were estimated. The End-Notched Flexure (ENF) test geometry was selected based on overall test simplicity and results accuracy. The adhesives Araldite® AV138, Araldite® 2015 and Sikaforce® 7752 were studied between high-strength aluminium adherends. Estimation of the CZM laws was carried out by an inverse methodology based on a curve fitting procedure, which enabled a precise estimation of the adhesive joints’ behaviour. The work allowed to conclude that a unique set of shear fracture toughness (GIIC) and shear cohesive strength (ts0) exists for each specimen that accurately reproduces the adhesive layer’ behaviour. With this information, the accurate strength prediction of adhesive joints in shear is made possible by CZM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: Evaluate the sensitivity/specificity of immunoperoxidase method in comparison with the standard immunofluorescence. MATERIAL AND METHODS: Retrospective review of 87 biopsies made for allograft dysfunction. Immunofluorescence (IF) was performed in frozen allograft biopsies using monoclonal antibody anti-C4d from Quidel®. The indirect immunoperoxidase (IP) technique was performed in paraffin-embebbed tissue with polyclonal antiserum from Serotec®. Biopsies were independently evaluated by two nephropathologist according Banff 2007 classification. RESULTS: By IF, peritubular C4d deposition were detected in 60 biopsies and absent in 27 biopsies. The evaluation of biopsy by IP was less precise due to the presence of background and unspecific staining. We find 13.8% (12/87) of false negative and Banff classification concordance in 79.3% (69/87) of cases (table1). The ROC curve study reveal a specificity of 100% and sensitivity of 80.0 % of IP method in relation to the gold standard (area under curve:0.900; 95% Confidence interval :0.817-0.954; p=0.0001). Banff Classification C4d Cases Immunofluorescence Immunoperoxidase n =87 Diffuse Negative 3 (3.4%) Focal Negative 9 (10.3%) Negative Negative 27 (31.0%) Diffuse Diffuse 33 (37.9%) Focal Focal 9 (10.3%) Diffuse Focal 6 (6.9%) CONCLUSION: The IP method presents a good specificity, but lesser sensitivity to C4d detection in allograft dysfunction. The evaluation is more difficult, requiring more experience of the observer than IF method. If frozen tissue is unavailable, the use of IP for C4d detection is acceptable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Container Loading Problem (CLP) literature has traditionally evaluated the dynamic stability of cargo by applying two metrics to box arrangements: the mean number of boxes supporting the items excluding those placed directly on the floor (M1) and the percentage of boxes with insufficient lateral support (M2). However, these metrics, that aim to be proxies for cargo stability during transportation, fail to translate real-world cargo conditions of dynamic stability. In this paper two new performance indicators are proposed to evaluate the dynamic stability of cargo arrangements: the number of fallen boxes (NFB) and the number of boxes within the Damage Boundary Curve fragility test (NB_DBC). Using 1500 solutions for well-known problem instances found in the literature, these new performance indicators are evaluated using a physics simulation tool (StableCargo), replacing the real-world transportation by a truck with a simulation of the dynamic behaviour of container loading arrangements. Two new dynamic stability metrics that can be integrated within any container loading algorithm are also proposed. The metrics are analytical models of the proposed stability performance indicators, computed by multiple linear regression. Pearson’s r correlation coefficient was used as an evaluation parameter for the performance of the models. The extensive computational results show that the proposed metrics are better proxies for dynamic stability in the CLP than the previous widely used metrics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective Public health organizations recommend that preschool-aged children accumulate at least 3 h of physical activity (PA) daily. Objective monitoring using pedometers offers an opportunity to measure preschooler's PA and assess compliance with this recommendation. The purpose of this study was to derive step-based recommendations consistent with the 3 h PA recommendation for preschool-aged children. Method The study sample comprised 916 preschool-aged children, aged 3 to 6 years (mean age = 5.0 ± 0.8 years). Children were recruited from kindergartens located in Portugal, between 2009 and 2013. Children wore an ActiGraph GT1M accelerometer that measured PA intensity and steps per day simultaneously over a 7-day monitoring period. Receiver operating characteristic (ROC) curve analysis was used to identify the daily step count threshold associated with meeting the daily 3 hour PA recommendation. Results A significant correlation was observed between minutes of total PA and steps per day (r = 0.76, p < 0.001). The optimal step count for ≥ 3 h of total PA was 9099 steps per day (sensitivity (90%) and specificity (66%)) with area under the ROC curve = 0.86 (95% CI: 0.84 to 0.88). Conclusion Preschool-aged children who accumulate less than 9000 steps per day may be considered Insufficiently Active.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction. Peritubular capillary complement 4d staining is one of the criteria for the diagnosis of antibody-mediated rejection, and research into this is essential to kidney allograft evaluation. The immunofluorescence technique applied to frozen sections is the present gold-standard method for complement 4d staining and is used routinely in our laboratory. The immunohistochemistry technique applied to paraffin-embedded tissue may be used when no frozen tissue is available. Material and Methods. The aim of this study is to evaluate the sensitivity and specificity of immunohistochemistry compared with immunofluorescence. We describe the advantages and disadvantages of the immunohistochemistry vs. the immunofluorescence technique. For this purpose complement 4d staining was performed retrospectively by the two methods in indication biopsies (n=143) and graded using the Banff 07 classification. Results. There was total classification agreement between methods in 87.4% (125/143) of cases. However, immunohistochemistry staining caused more difficulties in interpretation, due to nonspecific staining in tubular cells and surrounding interstitium. All cases negative by immunofluorescence were also negative by immunohistochemistry. The biopsies were classified as positive in 44.7% (64/143) of cases performed by immunofluorescence vs. 36.4% (52/143) performed by immunohistochemistry. Fewer biopsies were classified as positive diffuse in the immunohistochemistry group(25.1% vs. 31.4%) and more as positive focal (13.2% vs. 11.1%). More cases were classified as negative by immunohistochemistry (63.6% vs. 55.2%). Study by ROC curve showed immunohistochemistry has a specificity of 100% and a sensitivity of 81.2% in relation to immunofluorescence (AUC: 0.906; 95% confidence interval: 0.846-0.949; p=0.0001). Conclusions. The immunohistochemistry method presents an excellent specificity but lower sensitivity to C4d detection in allograft dysfunction. The evaluation is more difficult, requiring a more experienced observer than the immunofluorescence method. Based on these results, we conclude that the immunohistochemistry technique can safely be used when immunofluorescence is not available.