1000 resultados para Técnica de conservación de alimentos


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to investigate the action of the flocculating agents Panfloc and Panclar a full factorial design 2³ and a Central Composite design 2² were carried out. The control variables were the flocculant concentration, pH and temperature. The response variables were phenolic compounds reduction and spectral area reduction. The best conditions of treatment was hydrolyzate at pH 9 for both coagulants, but the use of Panfloc was more effective in the phenolic compounds reduction (73.9%) and spectral area reduction (65.8%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The 10B isotope tracer technique is essential to study the B mobility in plants. Factors that can influence the quality of measured B isotope ratios were optimized experimentally using High Resolution Inductively Coupled Plasma Mass Spectrometry (HRICP-MS). An isotopically certified standard (NIST SRM-951) was used. The best combination was obtained using a resolution of 400, a RF power of 1250 W, followed by 15 measurements over a 10-s integration period each (15*10). Utilizing this approach it was possible to obtain a precision of 0.3 % in standard material and 2z % in the experimental samples. The results show the importance of establishing optimized work conditions before carrying out the analytical series.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a practical and rapid method which was validated for simultaneous quantification and confirmation of 29 pesticides in fruits and vegetables using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The samples were extracted following the method known as QuEChERS. Using the developed chromatographic conditions, the pesticides can be separated in less than 9 min. Two multiple reaction monitoring (MRM) assays were used for each pesticide. Four representative matrices (lettuce, tomato, apple and grapes) were selected to investigate the effect in recoveries and precision. Typical recoveries ranged from 70-120%, with relative standard deviation (RSDs) lower than 20%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analysis of fatty acid (FA) esters by gas chromatography and flame ionization detector (FID) normally uses the normalization method. However, if one FA is wrongly estimated, the results could be greatly affected. In this study, methodologies using internal standards and correction factors for the FID response are described. The results show that by using theoretical correction factors associated to the internal standardization, the quantitative analyses of the FAs are expressed in mass, increasing the accuracy and facilitating the interpretation and comparison of the results for foods and biodiesels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The DGT technique allows one to measure quantitatively free and labile metal species in aquatic systems. Nevertheless, for this approach, knowledge is required of the diffusion coefficients of the analytes in a diffusive layer. In this study, the diffusion coefficients of Hg(II), As(III), Mn(II), Mg(II), Cu(II), Cd(II) were determined in agarose gel and those of Ba(II), Cd(II), Cu(II), Mg(II), Mn(II) e Zn(II) in cellulose acetate membranes. These materials presented good performance and the reported results can be used as a data base for further DGT studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article discusses the adsorption kinetics of a L-cysteine monolayer onto a gold surface by means of information obtained through the QCM technique. The results indicate that the adsorption process is rapid and follows the Langmuir isotherm, in which adsorption and desorption are considered. From these measurements the following parameter values were obtained: k d = (4.2 ± 0.4) x 10-3 s-1, k a = 75 ± 6 M-1 s-1, Keq=(1.8 ± 0.3) x 10(4) M-1 and ΔGads = - (5.8 ± 0.2) kcal mol-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is an overview of LC-MS techniques applied for macrolide determination in food, including sample preparation and method validation, as well as the policies adopted by international agencies regarding their presence in food. Techniques for the analysis of macrolides in food normally include solid phase or liquid-liquid extraction followed by HPLC. UHPLC presents advantages in running time, detectability and solvent consumption. Triple-quadrupoles are the most common analyzers in instruments used for the determination of contaminants in food, but time-of-flight and ion-trap spectrometers have been successfully applied for analyses focusing on the investigation of structural formula or the presence of degradation products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of veterinary drug residues in foods of animal origin is an important issue because of the risk these compounds pose to human health in addition to their persistence and tendency to bioaccumulate. In recent years, significant progress has been made in the area and this review presents the state of the art in sample preparation procedures associated with chromatographic techniques coupled to mass spectrometry for multiresidue determination of veterinary drugs in food of animal origin at concentration levels suitable for the control of residues and contaminants in food.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the level of the metals Pb mg kg-1 and Cd mg kg-1 found in plant species and the contribution of the levels detected in contaminated soils located in the urban area of the city of Santo Amaro, Bahia. Levels were determined by graphite furnace and flame atomic absorption spectrometry. The results showed the presence of Pb and Cd in plant species at levels ranging from 0.18 to 118.2 mg kg-1 and 0.04 to 7.29 mg kg-1, respectively. The concentration values obtained varied according to the plant species and were not strongly influenced by the concentration values detected in the soil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chloropropanols are a well-known group of food processing contaminants. They are formed through the reaction between lipids and chlorides when submitted to thermal treatment, and can be found in free and bound form. Although free chloropropanols were identified around 30 years ago, the occurrence of bound forms, especially 3-MCPD, and glycidyl fatty acid esters, has only recently been reported in several food products. Dietary exposure to these ester-bound compounds has been considered a priority food safety issue since free forms can be potentially released through the action of gut lipases, representing a major toxicological concern.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was the immobilization of the enzyme Candida antarctica lipase B (CAL B) using the sol-gel method of immobilization and three different initiators of the polymerization reaction: one acid (HCl), one basic (NH4OH) and the other nucleophilic (HBr). Tetraethylorthosilicate was used as the silica precursor. The influence of the additive PEG 1500 on immobilization was assessed. The efficiency of the process was evaluated considering the esterification activity of the xerogels. The immobilization process provided enhanced thermal stability, storage and operational aspects relative to the free enzyme. Storage temperature proved one of the main variables to be considered in the process, with the xerogels stored under refrigeration showing better results in terms of residual activity (nearly 200 days with ≥ 90% residual activity of basic and nucleophilic xerogels) when compared with storage at ambient temperature (nearly 40 days). The results demonstrated the possibility of reuse of derivatives and a greater number of cycles (nine), considering a residual activity of 50%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microemulsions (MEs) are thermodynamically stable systems consisting of nanosized droplets dispersed in a solvent continuous medium (known as pseudo-phase), which is immiscible with the dispersed phase. These systems consist of water, a hydrophobic solvent called "oil," an amphiphile and often, a co-surfactant that is normally a medium chain alcohol. A large number of publications describe the importance of MEs in many branches of chemistry, and there is an intensive search for new applications. In addition, MEs have been applied in many areas, including oil extraction, removal of environmental pollutants from soils and effluents, dissolution of additives in lubricants and cutting oils, cleaning processes, dyeing and textile finishing, as nanoreactors to obtain nanoparticles of metals, semiconductors, superconductors, magnetic and photographic materials, and latex. However, only some studies indicate the potential applications of MEs in food and even fewer evaluate their chemical behavior. Potential applications of MEs in food comprise dissolution of lipophilic additives, stabilization of nutrients and biologically active compounds, using as an antimicrobial agent and to maximize the efficiency of food preservatives. This work consists of a literature review focusing on composition and physical and chemical characteristics of microemulsions. Despite the small number of studies on the subject reported in the literature, we demonstrate some potential applications of MEs in food chemistry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound as a metrology tool has many applications in health care, industrial, and chemical analyses. Ultrasonic techniques are rapid, low-cost, non-invasive, and highly repeatable. Although ultrasound can be used to measure emulsions, no effort had been made thus far to optimize its sensitivity for metrological analysis. In this work, a technique for analyzing oil in water was validated. The wave velocity and attenuation were chosen as the ultrasonic parameters. The technique was implemented in the boundary region established by law for effluents from industrial plants involved with biofuel manufacturing. A technical effort of this study was to establish stable emulsions in concentrations close to the desired limit of study. The phase behaviours of pseudo-ternary oil, sodium chloride, and sodium lauryl sulphate were studied. The composition in the widest region of the diagram allowed for the formation of a stable emulsion, from which the ultrasound measurement was carried out. An analytical curve was obtained using ultrasonic attenuation to determine the content of oils and greases in wastewater ranging 15–240 ppm. The speed of sound did not appear to be an applicable parameter for this application. The technique was demonstrated to be an important alternative solution for the continuous monitoring of wastewater with regard to oil concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work was developed to adapt culture filtrates of Alternaria solani to be used in vitro selection of resistant potato. Three isolates of A. solani (I1 and I2) from Eldorado do Sul and Rio Pardo were used. Two liquid media, V8 and Czapek, were used to grow each of the fungal isolate, giving six culture filtrates (I1V8, I2V8, I3V8, I1Cz, I2Cz and I3Cz). Two sterilization forms, Millipore and autoclave were tested. There was no difference in these two sterilization forms. Tissue culture and toxic filtrates of A. solani have a potential to reduce the time in selection of resistant potato.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho teve por objetivo verificar a viabilidade de utilização da técnica de PCR, usando primers considerados específicos, para identificação de Xanthomonas axonopodis pv. phaseoli (Xap) e x. axonopodis pv. phaseoli var. fuscans (Xapf), visando criar bases para sua utilização em diagnose rotineira e em programas de certificação de sementes. Foram incluídos no estudo 42 isolados da bactéria provenientes de locais distintos, além de outros gêneros, espécies e patovares, para ser verificada a especificidade dos primers. Os resultados obtidos permitem concluir que os primers utilizados são adequados para identificação de Xap e Xapf, embora dois isolados patogênicos não tenham sido amplificados. Foi observada também a amplificação de uma banda fraca para X. axonopodis pv. vitians, com o mesmo número de pares de bases, o que sugere existir homologia entre estes patovares, na região amplificada.