990 resultados para Sub-sampling
Resumo:
The introduction of skin sub-stiffening features has the potential to modify the local stability and fatigue crack growth performance of stiffened panels. Proposed herein is a method to enable initial static strength sizing of panels with such skin sub-stiffening features. The method uses bespoke skin buckling coefficients, automatically generated by Finite Element analysis and thus limits the modification to the conventional aerospace panel initial sizing process. The approach is demonstrated herein and validated for prismatic sub-stiffening features. Moreover, examination of the generated buckling coefficient data illustrates the influence of skin sub-stiffening on buckling behavior, with static strength increases typically corresponding to a reduction in the number of initial skin longitudinal buckle half-waves.
Resumo:
The rate of uptake of Endosulfan by Mytilus edulis L. exposed to pesticide concentrations of 0.1, 0.5, and 1.0 mg/l, and its subsequent elution on removal to clean sea water, was investigated. Higher residue levels were recorded for mussels exposed to higher concentrations of the pesticide, but concentration factors were reduced. There was a rapid initial fall in tissue residue levels on transfer to clean sea water due, it is suggested, to elution of Endosulfan adsorbed on particulate matter assimilated in the gut. The spawning period was prolonged at higher concentrations and, at 1.0 mg/l, the onset of spawning was delayed, possibly due to interference with gamonic action. At 0.1 mg/l, the minor protraction of the spawning period may reflect the effect of experimental tank conditions. No seasonal trend was obvious, and there was an exaggeration of the expected fall in condition in mussels exposed to higher concentrations of Endosulfan. In controls, the expected seasonal trend was reduced.
Resumo:
Chlorinated hydrocarbon pesticides are now present in low concentration in most waters. While generally not causing direct mortality so far as we know, they may well have sub-lethal effects, reducing the health and viability of marine organisms. In this study the effect of Endosulfan, DDT and dieldrin on respiration, heart beat and burrowing of some marine bivalves has been examined.
Resumo:
Quantifying nutrient and sediment loads in catchments is dif?cult owing to diffuse controls related to storm hydrology. Coarse sampling and interpolation methods are prone to very high uncertainties due to under-representation of high discharge, short duration events. Additionally, important low-?ow processes such as diurnal signals linked to point source impacts are missed. Here we demonstrate a solution based on a time-integrated approach to sampling with a standard 24 bottle autosampler con?gured to take a sample every 7 h over a week according to a Plynlimon design. This is evaluated with a number of other sampling strategies using a two-year dataset of sub-hourly discharge and phosphorus concentration data. The 24/7 solution is shown to be among the least uncertain in estimating load (inter-quartile range: 96% to 110% of actual load in year 1 and 97% to 104% in year 2) due to the increased frequency raising the probability of sampling storm events and point source signals. The 24/7 solution would appear to be most parsimonious in terms of data coverage and certainty, process signal representation, potential laboratory commitment, technology requirements and the ability to be widely deployed in complex catchments.
Resumo:
In this study, the feasibility of using H3PO4-activated lignin for hexavalent chromium adsorption has been investigated. The composite of activated lignin was characterized using FTIR, XRD and SEM with EDAX analysis. It was observed that the pH had a strong effect on the adsorption capacity; adsorption of Cr(VI) was more favorable at acidic pH with maximum uptake at pH 2. The adsorption equilibrium data were best represented by Koble-Corrigan isotherm. The monolayer sorption capacity obtained from the Langmuir model was found to be 77.85 mg/g. Adsorption showed pseudo-second order rate kinetics and the process involving the rate-controlling step is complex as it involves both film and intraparticle diffusion processes. The NaOH desorbing agent was able to release approximately 84% of metal ions. Thermodynamic parameters showed that the sorption process is exothermic and non-spontaneous. The overall Cr(VI) retention on the activated lignin surface perhaps includes both the physical adsorption of Cr(VI) and the consequent reduction of Cr(VI) to Cr(III). (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
A self-tuning filter is disclosed. The self-tuning filter includes a digital clocking signal and an input coupled to the digital clocking signal, whereby the input reads a value incident on the input when the digital clocking signal changes to a predetermined state. A clock-tunable filter is, furthermore, coupled to the digital clocking signal so that the frequency of the clock-tunable filter is adjusted in relation to a sampling frequency at which the digital clocking signal operates. The self-tuning filter may be applied to an input of a data acquisition unit and applied to an input having a variable sampling frequency. A method of controlling the frequency of a clock-tunable filter is also disclosed.
Resumo:
Background: Elevated C-reactive protein (CRP) concentration is a risk factor for cardiovascular events that may add prognostic information. Statin treatment is associated with significant reductions in CRP concentrations, which appear to be unrelated to the magnitude of LDL-cholesterol reduction. We investigated the effect of atorvastatin, across its dose range, on high sensitivity (hs)CRP in subjects at high cardiovascular risk. Methods: ACTFAST was a 12 week, prospective, multicenter, open-label trial in which high-risk subjects were assigned a starting dose of atorvastatin (10, 20, 40 or 80 mg/d) based on LDL-C and status of statin use at screening (1345 statin-free [ SF] and 772 previously statin-treated [ST]). Results: At baseline, ST subjects had significantly lower hsCRP levels than SF subjects (ST group 2.31, 95% CI 2.15, 2.48 mg/L vs. SF group 3.16, 95% CI 2.98, 3.34 mg/L, p
Resumo:
We report the discovery of WASP-34b, a sub-Jupiter-mass exoplanet transiting its 10.4-magnitude solar-type host star (1SWASP J110135.89-235138.4; TYC 6636-540-1) every 4.3177 days in a slightly eccentric orbit (e = 0.038±0.012). We find a planetary mass of 0.59±0.01 MJup and radius of 1.22-0.08+0.11 RJup. There is a linear trend in the radial velocities of 55±4 m s-1 y-1 indicating the presence of a long-period third body in the system with a mass ?0.45 MJup at a distance of ?1.2 AU from the host star. This third-body is either a low-mass star, a white dwarf, or another planet. The transit depth ((RP/Rstar)2 = 0.0126) and high impact parameter (b = 0.90) suggest that this could be the first known transiting exoplanet expected to undergo grazing transits, but with a confidence of only 80%. Radial velocity and photometric data are only available in electronic form at the CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/526/A130
Resumo:
UVES interstellar observations from the Paranal Observatory Project are presented for early-type stars located in the line of sight to the nearby open clusters IC 2391 (Omni Vel) and NGC 6475 (M7), with spectroscopic resolution R similar to 80 000 and signal-to-noise ratios in the Ti II (3383 angstrom), Ca II K, CH+ (4232 angstrom), Na I D and K I (7698 angstrom) lines of several hundred. The sightlines are a mixture of cluster and non-cluster objects. A total of 22 early-type stars (A and B type) are present in our sample towards IC 2391, with 21 towards NGC 6475/M7, and enable us to probe for differences in column density on scales from similar to 0.07 to 7.3 and similar to 0.05 to 4.9 pc in the respective clusters. Additionally, towards Praesepe the Na I D interstellar variation only is probed towards 13 sightlines and transverse scales of similar to 0.16-10.7 pc at R = 70 000. Towards IC 2391 variations are found in Ti II, Ca II K and Na I D column density in different sightlines of up to 0.7, 1.0 and 1.8 dex (excluding one star), respectively. This kind of variability correlates well with the Hipparcos parallax of the objects, and probes structure within the Local Bubble. For cluster-only objects the variations are 0.3, 0.3 and 0.5 dex, respectively. For the field of view towards NGC6475 the corresponding maximum variations are somewhat smaller, being 0.5, 0.3, 0.8 and 1.0 dex for Ti II, Ca II K, Na I and K I, respectively, for all objects and 0.4, 0.2, 0.6 and 0.7 dex for the cluster-only objects. These are uncorrelated with parallax, and again demonstrate that Ca II K tends to be more smoothly distributed than Na I D. A few likely cluster sightlines show evidence for CH+ and variations in this molecular species of a factor of 10 in equivalent width over sub-pc scales. Towards Praesepe variation in interstellar Na I D is small, being a maximum of only similar to 0.4 dex (including measurement errors), but with fewer sightlines studied. Overall, the scatter in the data is similar for the singly ionized species Ti II and Ca II, lending more support to the hypothesis that these two species sample similar parts of the interstellar medium (ISM). This also appears to be the case for the neutral species Na I D and K I in the one cluster studied. Finally, multiple-epoch observations from a variety of archive sources are used to search for astronomical unit (au) scale structure in the ISM towards 46 sightlines. There are tentative indications of structure on scales of tens to thousands of au for three sightlines. Future observations will confirm the veracity or otherwise of the time-variable components and others presented.
Resumo:
The eluent droplet size defines the number of sampling compartments in a continuously operated annular electrochromatograph and therefore influences separation efficiency. In this work, an assembly of two capillaries, a feeding capillary on the top and a receiving capillary placed under it, has been investigated to control droplet size. The receiving capillary prevents the liquid droplet formation beyond a critical size, which reduces the volume of sampling compartment as compared with the case of the electrolyte flow driven solely by gravity. With a receiving capillary, the electrolyte droplet size was reduced from 1.5 to 0.46 mm. Further decrease of droplet size was not possible due to a so-called droplet jump upwards effect which has been observed on a hydrophilic glass surface with water. A typical electrolyte used in CAEC has high methanol content. In an attempt to improve the methanol-repellent properties of the glass surface, two approaches have been implemented: (i) self-assembled chemisorbed monolayers of an alkylsiloxane and (ii) fabrication of a nano-pin film. The methanol-repellent surface of the feeding capillary suppressed the droplet jump upwards effect. The surface remained methanol repellent in different solutions with lower polarity than that of water.
Resumo:
Lack of time to implement pharmaceutical care has been cited as a barrier to the routine provision of this extended patient-care service. Using self-reported work sampling methodology, this study investigated how community pharmacists utilise their time. Pharmacists working in community pharmacies in the Greater Belfast area were found to spend approximately 49% of their time engaged in professional activities, 29% in semi-professional activities and 22% involved in non-professional activities. The activity to which pharmacists devoted the majority of their time was product assembly and labelling, this being a task which can be performed by trained technical staff. Only 9.5% of community pharmacists' time was devoted to counselling patients on their prescription medicines. Wide variation in the amount of time apportioned to each activity was observed between the participating community pharmacists (n=30). Staffing levels within the community pharmacy were found to significantly influence pharmacists' involvement in a number of activities, with pharmacists who worked in pharmacies employing multiple pharmacists devoting more time to the assembly and labelling of products and less time to administrative tasks, non-professional encounters and to miscellaneous professional activities. Pharmacists working in pharmacies with a high prescription turnover were found to devote significantly less time to counselling patients regarding OTC products and in responding to patient symptoms.