997 resultados para Solar access
Resumo:
A composting Heat Extraction Unit (HEU) was designed to utilise waste heat from decaying organic matter for a variety of heating application The aim was to construct an insulated small scale, sealed, organic matter filled container. In this vessel a process fluid within embedded pipes would absorb thermal energy from the hot compost and transport it to an external heat exchanger. Experiments were conducted on the constituent parts and the final design comprised of a 2046 litre container insulated with polyurethane foam and kingspan with two arrays of qualpex piping embedded in the compost to extract heat. The thermal energy was used in horticultural trials by heating polytunnels using a radiator system during a winter/spring period. The compost derived energy was compared with conventional and renewable energy in the form of an electric fan heater and solar panel. The compost derived energy was able to raise polytunnel temperatures to 2-3°C above the control, with the solar panel contributing no thermal energy during the winter trial and the electric heater the most efficient maintaining temperature at its preset temperature of 10°C. Plants that were cultivated as performance indicators showed no significant difference in growth rates between the heat sources. A follow on experiment conducted using special growing mats for distributing compost thermal energy directly under the plants (Radish, Cabbage, Spinach and Lettuce) displayed more successful growth patterns than those in the control. The compost HEU was also used for more traditional space heating and hot water heating applications. A test space was successfully heated over two trials with varying insulation levels. Maximum internal temperature increases of 7°C and 13°C were recorded for building U-values of 1.6 and 0.53 W/m2K respectively using the HEU. The HEU successfully heated a 60 litre hot water cylinder for 32 days with maximum water temperature increases of 36.5°C recorded. Total energy recovered from the 435 Kg of compost within the HEU during the polytunnel growth trial was 76 kWh which is 3 kWh/day for the 25 days when the HEU was activated. With a mean coefficient of performance level of 6.8 calculated for the HEU the technology is energy efficient. Therefore the compost HEU developed here could be a useful renewable energy technology particularly for small scale rural dwellers and growers with access to significant quantities of organic matter
Resumo:
Stand alone solar powered refrigeration and water desalination, two of the most popular and sought after applications of solar energy systems, have been selected as the topic of research for the works presented in this thesis. The water desalination system based on evaporation and condensation was found to be the most suitable one to be powered by solar energy. It has been established that highoutput fast-response solar heat collectors used to achieve high rates of evaporation and reliable solar powered cooling system for faster rates of condensation are the most important factors in achieving increased outputs in solar powered desalination systems. Comprehensive reviews of Solar powered cooling/refrigeration and also water desalination techniques have been presented. In view of the fact that the Institute of Technology, Sligo has a well-established long history of research and development in the production of state of the art high-efficiency fast-response evacuated solar heat collectors it was decided to use this know how in the work described in this thesis. For this reason achieving high rates of evaporation was not a problem. It was, therefore, the question of the solar powered refrigeration that was envisaged to be used in the solar powered desalination tofacilitate rapid condensation of the evaporated water that had to be addressed first. The principles of various solar powered refrigeration techniques have also been reviewed. The first step in work on solar powered refrigeration was to successfully modify a conventional refrigerator working on Platen-Munters design to be powered by highoutput fast-response evacuated solar heat collectors. In this work, which was the first ever successful attempt in the field, temperatures as low as —19°C were achieved in the icebox. A new approach in the use of photovoltaic technology to power a conventional domestic refrigerator was also attempted. This was done by modifying a conventional domestic refrigerator to be powered by photovoltaic panels in the most efficient way. In the system developed and successfully tested in this approach, the power demand has been reduced phenomenally and it is possible to achieve 48 hours of cooling power with exposure to just 7 hours of sunshine. The successful development of the first ever multi-cycle intermittent solar powered icemaker is without doubt the most exciting breakthrough in the work described in this thesis. Output of 74.3kg of ice per module with total exposure area of 2.88 m2, or 25.73kg per m2, per day is a major improvement in comparison to about 5-6kg of ice per m2 per day reported for all the single cycle intermittent systems. This system has then become the basis for the development of a new solar powered refrigeration system with even higher output, named the “composite” system described in this thesis. Another major breakthrough associated with the works described in this thesis is the successful development and testing of the high-output water desalination system. This system that uses a combination of the high-output fast-response evacuated solar heat collectors and the multi-cycle icemaker. The system is capable of producing a maximum of 141 litres of distilled water per day per module which has an exposure area of 3.24m2, or a production rate of 43.5 litres per m2 per day. Once again when this result is compared to the reported daily output of 5 litres of desalinated water per m per day the significance of this piece of work becomes apparent. In the presentation of many of the components and systems described in this thesis CAD parametric solid modelling has been used instead of photographs to illustrate them more clearly. The multi-cycle icemaker and the high-output desalination systems are the subject of two patent applications.
Resumo:
Background:The radial access provides a lower risk of bleeding and vascular complications related to the puncture site in comparison to the femoral access. Recent studies have suggested a reduction in mortality associated with the radial access in patients with acute myocardial infarction undergoing percutaneous coronary intervention.Objective:To compare the occurrence of adverse cardiovascular ischemic and hemorrhagic events in patients undergoing primary angioplasty according to the type of arterial access route.Methods:From August 2010 to December 2011, 588 patients undergoing primary percutaneous coronary intervention during acute ST-segment elevation myocardial infarction were assessed; they were recruited from 47 centers participating in the ACCEPT registry. Patients were grouped and compared according to the arterial access used for the procedure.Results:The mean age was 61.8 years; 75% were males and 24% had diabetes mellitus. There was no difference between groups as regards the procedure success rate, as well as regards the occurrence of death, reinfarction, or stroke at six months of follow-up. Severe bleeding was reported in 1.1% of the sample analyzed, with no statistical difference related to the access used.Conclusions:The femoral and radial accesses are equally safe and effective for the performance of primary percutaneous coronary intervention. The low rate of cardiovascular events and of hemorrhagic complications reflects the quality of the participating centers and the operators expertise with the use of both techniques.
Resumo:
Background: According to some international studies, patients with acute coronary syndrome (ACS) and increased left atrial volume index (LAVI) have worse long-term prognosis. However, national Brazilian studies confirming this prediction are still lacking. Objective: To evaluate LAVI as a predictor of major cardiovascular events (MCE) in patients with ACS during a 365-day follow-up. Methods: Prospective cohort of 171 patients diagnosed with ACS whose LAVI was calculated within 48 hours after hospital admission. According to LAVI, two groups were categorized: normal LAVI (≤ 32 mL/m2) and increased LAVI (> 32 mL/m2). Both groups were compared regarding clinical and echocardiographic characteristics, in- and out-of-hospital outcomes, and occurrence of ECM in up to 365 days. Results: Increased LAVI was observed in 78 patients (45%), and was associated with older age, higher body mass index, hypertension, history of myocardial infarction and previous angioplasty, and lower creatinine clearance and ejection fraction. During hospitalization, acute pulmonary edema was more frequent in patients with increased LAVI (14.1% vs. 4.3%, p = 0.024). After discharge, the occurrence of combined outcome for MCE was higher (p = 0.001) in the group with increased LAVI (26%) as compared to the normal LAVI group (7%) [RR (95% CI) = 3.46 (1.54-7.73) vs. 0.80 (0.69-0.92)]. After Cox regression, increased LAVI increased the probability of MCE (HR = 3.08, 95% CI = 1.28-7.40, p = 0.012). Conclusion: Increased LAVI is an important predictor of MCE in a one-year follow-up.
Resumo:
Dezentrale Energieversorgung; Regenerative Energien; Kraft-Wärme-Kopplung; Windkraft; Photovoltaik; Solarthermie; Kraft-Wärme-Kälte-Kopplung; Bewertungskriterien dezentraler Energieversorgung
Resumo:
Background: Fewer bleeding complications and early ambulation make radial access a privileged route for cardiac catheterization. However, transradial (TR) approach is not always successful, requiring its conversion into femoral access. Objectives: To evaluate the rate of conversion from radial into femoral access in cardiac catheterization and to identify its predictors. Methods: Prospective dual-center registry, including 7632 consecutive patients undergoing catheterization via the radial access between Jan/2009 and Oct/2012. We evaluated the incidence of conversion into femoral access and its predictors by logistic regression analysis. Results: The patients’ mean age was 66 ± 11 years, and 32% were women. A total of 2969 procedures (38.4%) were percutaneous coronary interventions (PCI), and the most used first intention arterial access was the right radial artery (97.6%). Radial access failure rate was 5.8%. Independent predictors of conversion from radial into femoral access were the use of short introducer sheaths (OR 3.047, CI: 2.380-3.902; p < 0.001), PCI (OR 1.729, CI: 1.375-2.173; p < 0.001), female sex (OR 1.569, CI: 1.234-1.996; p < 0.001), multivessel disease (OR 1.457, CI: 1.167-1.819; p = 0.001), body surface area (BSA) ≤ 1.938 (OR 1.448, CI: 1.120-1.871; p = 0.005) and age > 66 years (OR 1.354, CI: 1.088-1.684; p = 0.007). Conclusion: Transradial approach for cardiac catheterization has a high success rate and the need for its conversion into femoral access in this cohort was low. Female sex, older age, smaller BSA, the use of short introducer sheaths, multivessel disease and PCI were independent predictors of conversion into femoral access.
Resumo:
In the field of agrometeorological studies we are in need of the estimation of the solar radiation frequently. At the present study the authors have worked out some dat:t regarding the hours of sunshine during the months of August, September, October, November, December and January of 1957, 1958 and 1959. Based on such hours of sunshine in the Agrometeorological Station, located at the Escola Superior de Agricultura "Luiz de Queiroz" - U.S. P., in Piracicaba, the authors calculated the solar radiation received on a plane and horizontal surface, from the method proposed by Glover and Mc Culloch. With those results the authors estimated the percentual part of radiation that would be received on vertical wall facing north.
Resumo:
O efeito da orientação cardial de uma parcela experimental sobre a variação de temperatura do solo foi estudado. Verificou-se que à latitude de 15°S, a parcela com uma inclinação de rampa de 5% apresentou diferenças mensuráveis entre as temperaturas do solo nas diversas faces de exposição, sendo mais salientes as diferenças entre as faces Norte e Sul. Os dados obtidos foram coerentes com as determinações de radiação solar recebida.
Resumo:
The present paper refers to a research work carried out at the Dept. of Agriculture and Horticulture of ESALQ, University of São Paulo, in Piracicaba, State of São Paulo (latitude 22º42'S, longitude 47º33' WG and altitude 546 m). Sowing at different times and using artificial cover, an attempt was made to evaluate the behavior of cultivar IAC 17 of cotton (Gossypium hirsutum L.) as to production and quality of fiber relating to incident solar radiation. Incident solar radiation, as well as insolation during the trial period, were tabulated and compared with yelds and agricultural and technological characters of fibers. The treatment under cover showed a mean level of incident solar radiation equivalent to less than 20% of that at clear sky, causing a decrease in cotton production and in the agricultural and technological characters of fibers.
Resumo:
O presente trabalho se propõe a verificar de que modo a orientação de uma edificação rural influe na carga térmica radiante (radiação solar) interceptada pela mesma. Duas situações freqüentemente encontradas na prática são examinadas: a orientação Norte-Sul e a Leste-Oeste. Para determinar a carga térmica radiante, de importância nos problemas deventilação e refrigeração, é adotado um modelo de construção a título de exemplo, sendo que as relações aqui propostas são aplicáveis a qualquer modelo de construção desejado. Os resultados mostraram quea carga térmica radiante da exposição Leste-Oeste chega a ser 74% da carga na exposição Norte-Sul.
Resumo:
v.17:no.4(1932)
Resumo:
v.7:no.6(1943)
Resumo:
v.17:no.4(1932)
Resumo:
This paper analyzes the employment relationship on the basis of the notion of access. We argue that the degree of access provided by a job is an incentive to activate the employee’s self-actualization needs. We investigate the effect of access on the workers’ performance through an agency model and provide a number of propositions with practical implications for personnel policies. Our results are consistent with the intuition emerged from the real business practice as well as with many of the arguments on the substitutive role between monetary and non-monetary incentives frequently reported in the literature.