961 resultados para Soil-water Characteristic Curve


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this work was to evaluate rootstock influence on agronomical, ecophysiological and qualitative characteristics of 'Syrah' vines managed by double pruning. Grapevines were grafted onto 'SO4', '110 Richter' and '1103 Paulsen' rootstocks and trained in vertical shoot position, with no irrigation. Ecophysiological characteristics, yield and composition of ripe grapes were evaluated in three crop seasons (2007, 2008 and 2010). Rootstocks did not affect pre-dawn water potential, with values close to -0.2 MPa, indicating that there was no soil water deficit at the end of ripening (June). There was also no significant effect of rootstocks on yield. The rootstock '1103 Paulsen' induced lower vegetative growth, lower photosynthetic rate and the best results for berry maturation for crop seasons with lower amount of rainfall. The rootstocks '110 Richter' and 'SO4' showed higher vigor under the meteorological conditions of 2010 and the greatest photosynthetic rates in the same period. Meteorological conditions significantly affected technological and phenolic ripeness, with best results observed in drought years. The '1103 Paulsen' rootstock provides better balance between vigor and yield, increasing grape quality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The estimation of reference evapotranspiration (ETo), used in water balance, allows to determine soil water content, assisting on irrigation management. The present study aimed to compare simple ETo estimating methods with the Penman-Monteith (FAO), in the folowing time scales: daily, 5, 10, 15 and 30 days and monthly in the counties of Frederico Westphalen and Palmeira das Missoes, in the Rio Grande do Sul state, Brazil. The methods tested had their efficiency improved by increasing the time scale of analysis, keeping the same performance for both locations. The highest and lowest ETo values occurred in December and June, respectively. Most methods underestimated ETo. For any of the time scales Makking and Radiaton FAO24 methods can replace the Penman-Monteith for estimating ETo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Previous evidence supports a direct relationship between the calcium burden (volume) on post-contrast CT with the percent internal carotid artery (ICA) stenosis at the carotid bifurcation. We sought to further investigate this relationship by comparing non-enhanced CT (NECT) and digital subtraction angiography (DSA). Methods: 50 patients (aged 41-82 years) were retrospectively identified who had undergone cervical NECT and DSA. A 64-multidetector array CT (MDCT) scanner was utilised and the images reviewed using preset window widths/levels (30/300) optimised to calcium, with the volumes measured via three-dimensional reconstructive software. Stenosis measurements were performed on DSA and luminal diameter stenoses >40% were considered "significant". Volume thresholds of 0.01, 0.03, 0.06, 0.09 and 0.12 cm(3) were utilised and Pearson's correlation coefficient (r) was calculated to correlate the calcium volume with percent stenosis. Results: Of 100 carotid bifurcations, 88 were available and of these 7 were significantly stenotic. The NECT calcium volume moderately correlated with percent stenosis on DSA r=0.53 (p<0.01). A moderate-strong correlation was found between the square root of calcium volume on NECT with percent stenosis on DSA (r=0.60, p<0.01). Via a receiver operating characteristic curve, 0.06 cm(3) was determined to be the best threshold (sensitivity 100%, specificity 90.1%, negative predictive value 100% and positive predictive value 46.7%) for detecting significant stenoses. Conclusion: This preliminary investigation confirms a correlation between carotid bifurcation calcium volume and percent ICA stenosis and is promising for the optimal threshold for stenosis detection. Future studies could utilise calcium volumes to create a "score" that could predict high grade stenosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background Smear negative pulmonary tuberculosis (SNPT) accounts for 30% of pulmonary tuberculosis cases reported yearly in Brazil. This study aimed to develop a prediction model for SNPT for outpatients in areas with scarce resources. Methods The study enrolled 551 patients with clinical-radiological suspicion of SNPT, in Rio de Janeiro, Brazil. The original data was divided into two equivalent samples for generation and validation of the prediction models. Symptoms, physical signs and chest X-rays were used for constructing logistic regression and classification and regression tree models. From the logistic regression, we generated a clinical and radiological prediction score. The area under the receiver operator characteristic curve, sensitivity, and specificity were used to evaluate the model's performance in both generation and validation samples. Results It was possible to generate predictive models for SNPT with sensitivity ranging from 64% to 71% and specificity ranging from 58% to 76%. Conclusion The results suggest that those models might be useful as screening tools for estimating the risk of SNPT, optimizing the utilization of more expensive tests, and avoiding costs of unnecessary anti-tuberculosis treatment. Those models might be cost-effective tools in a health care network with hierarchical distribution of scarce resources.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background Decreased heart rate variability (HRV) is related to higher morbidity and mortality. In this study we evaluated the linear and nonlinear indices of the HRV in stable angina patients submitted to coronary angiography. Methods We studied 77 unselected patients for elective coronary angiography, which were divided into two groups: coronary artery disease (CAD) and non-CAD groups. For analysis of HRV indices, HRV was recorded beat by beat with the volunteers in the supine position for 40 minutes. We analyzed the linear indices in the time (SDNN [standard deviation of normal to normal], NN50 [total number of adjacent RR intervals with a difference of duration greater than 50ms] and RMSSD [root-mean square of differences]) and frequency domains ultra-low frequency (ULF) ≤ 0,003 Hz, very low frequency (VLF) 0,003 – 0,04 Hz, low frequency (LF) (0.04–0.15 Hz), and high frequency (HF) (0.15–0.40 Hz) as well as the ratio between LF and HF components (LF/HF). In relation to the nonlinear indices we evaluated SD1, SD2, SD1/SD2, approximate entropy (−ApEn), α1, α2, Lyapunov Exponent, Hurst Exponent, autocorrelation and dimension correlation. The definition of the cutoff point of the variables for predictive tests was obtained by the Receiver Operating Characteristic curve (ROC). The area under the ROC curve was calculated by the extended trapezoidal rule, assuming as relevant areas under the curve ≥ 0.650. Results Coronary arterial disease patients presented reduced values of SDNN, RMSSD, NN50, HF, SD1, SD2 and -ApEn. HF ≤ 66 ms2, RMSSD ≤ 23.9 ms, ApEn ≤−0.296 and NN50 ≤ 16 presented the best discriminatory power for the presence of significant coronary obstruction. Conclusion We suggest the use of Heart Rate Variability Analysis in linear and nonlinear domains, for prognostic purposes in patients with stable angina pectoris, in view of their overall impairment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To develop and validate a short health literacy assessment tool for Portuguese-speaking adults. METHODS: The Short Assessment of Health Literacy for Portuguese-speaking Adults is an assessment tool which consists of 50 items that assess an individual's ability to correctly pronounce and understand common medical terms. We evaluated the instrument's psychometric properties in a convenience sample of 226 Brazilian older adults. Construct validity was assessed by correlating the tool scores with years of schooling, self-reported literacy, and global cognitive functioning. Discrimination validity was assessed by testing the tool's accuracy in detecting inadequate health literacy, defined as failure to fully understand standard medical prescriptions. RESULTS: Moderate to high correlations were found in the assessment of construct validity (Spearman's coefficients ranging from 0.63 to 0.76). The instrument showed adequate internal consistency (Cronbach's alpha=0.93) and adequate test-retest reliability (intraclass correlation coefficient=0.95). The area under the receiver operating characteristic curve for detection of inadequate health literacy was 0.82. A version consisting of 18 items was tested and showed similar psychometric properties. CONCLUSIONS: The instrument developed showed good validity and reliability in a sample of Brazilian older adults. It can be used in research and clinical settings for screening inadequate health literacy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A armazenagem de água no solo é muito variável no tempo e no espaço devido à influência de vários fatores ambientais e topográficos. Objetivou-se neste estudo: quantificar a armazenagem de água no solo; avaliar sua estabilidade temporal e sua variabilidade espacial em um local próximo e outro distante do sistema radicular numa sucessão feijão/aveia-preta; e constatar sua variabilidade espacial em função do relevo. Em área experimental de 1.500 m², situada em Piracicaba-SP (latitude de 22° 42' 30" S, longitude de 47° 38' 00" W e 546 m de altitude), estabeleceram-se 60 pontos de amostragem, distanciados entre si de 5 m, numa grade de 10 por 6 pontos (50 x 30 m). Os valores da armazenagem de água no solo apresentaram comportamento-padrão para o solo estudado, com valores maiores em profundidade do que na camada mais superficial. Houve maior estabilidade temporal da armazenagem de água no solo durante o período chuvoso, porém na fase de secagem do solo a estabilidade temporal também foi constatada, mas com valores de coeficiente de correlação mais elevados na camada de 0,0-0,80 m, mostrando que essa estabilidade foi claramente devida à posição topográfica desses pontos, os quais estão localizados na porção mais baixa do relevo. Assim, o ponto 52 foi escolhido como representativo da média na fase de recarga de água no solo em ambas as camadas estudadas, e o ponto 46, na camada superior durante a fase de secagem do solo. A dependência espacial da variabilidade da armazenagem de água no solo foi detectada em ambas as camadas de solo, porém com maior alcance na camada de 0,0-0,40 m, quando houve ocorrência de precipitação. Quando as chuvas cessaram, o alcance foi maior na camada de 0,0-0,80 m. Durante o período chuvoso, o padrão de variabilidade espacial foi muito semelhante em ambas as camadas de solo, com armazenagens maiores na faixa de maior inclinação e depressões do terreno.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study of the hydro-physical behavior in soils using toposequences is of great importance for better understanding the soil, water and vegetation relationships. This study aims to assess the hydro-physical and morphological characterization of soil from a toposequence in Galia, state of São Paulo, Brazil). The plot covers an area of 10.24 ha (320 × 320 m), located in a semi-deciduous seasonal forest. Based on ultra-detailed soil and topographic maps of the area, a representative transect from the soil in the plot was chosen. Five profiles were opened for the morphological description of the soil horizons, and hydro-physical and micromorphological analyses were performed to characterize the soil. Arenic Haplustult, Arenic Haplustalf and Aquertic Haplustalf were the soil types observed in the plot. The superficial horizons had lower density and greater hydraulic conductivity, porosity and water retention in lower tensions than the deeper horizons. In the sub-superficial horizons, greater water retention at higher tensions and lower hydraulic conductivity were observed, due to structure type and greater clay content. The differences observed in the water retention curves between the sandy E and the clay B horizons were mainly due to the size distribution, shape and type of soil pores.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fluxes of CO2 were measured above a sugarcane plantation using the eddy-covariance method covering two growth cycles, representing the second and third re-growth (ratoons) harvested with stubble burning. The total net ecosystem exchange (NEE) in the first cycle (second ratoon, 393 days long) was −1964 ± 44 g C m−2; the gross ecosystem productivity (GEP) was 3612 ± 46 g C m−2 and the ecosystem respiration (RE) was 1648 ± 14 g C m−2. The NEE and GEP totals in the second cycle (third ratoon, 374 days long) decreased 51% and 25%, respectively and RE increased 7%. Accounting for the carbon emitted during biomass burning and the removal of stalks at harvest, net ecosystem carbon balance (NECB) totals were 102 ± 130 g C m−2 and 403 ± 84 g C m−2 in each cycle respectively. Thus the sugarcane agrosystem was approximately carbon neutral in the second ratoon. Yield in stalks fresh weight (SFW) attained the regional average (8.3 kg SFW m−2). Although it was a carbon source to the atmosphere, observed productivity (6.2 kg SFW m−2) of the third ratoon was 19% lower than the regional average due to the lower water availability observed during the initial 120 days of re-growth. However, the overall water use efficiency (WUE) achieved in the first cycle (4.3 g C kg−1 H2O) decreased only 5% in the second cycle. © 2013 Elsevier B.V. All rights reserved

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to compare the techniques of indirect immunofluorescence assay (IFA) and flow cytometry to clinical and laboratorial evaluation of patients before and after clinical cure and to evaluate the applicability of flow cytometry in post-therapeutic monitoring of patients with American tegumentary leishmaniasis (ATL). Sera from 14 patients before treatment (BT), 13 patients 1 year after treatment (AT), 10 patients 2 and 5 years AT were evaluated. The results from flow cytometry were expressed as levels of IgG reactivity, based on the percentage of positive fluorescent parasites (PPFP). The 1:256 sample dilution allowed us to differentiate individuals BT and AT. Comparative analysis of IFA and flow cytometry by ROC (receiver operating characteristic curve) showed, respectively, AUC (area under curve) = 0.8 (95% CI = 0.64–0.89) and AUC = 0.90 (95% CI = 0.75–0.95), demonstrating that the flow cytometry had equivalent accuracy. Our data demonstrated that 20% was the best cut-off point identified by the ROC curve for the flow cytometry assay. This test showed a sensitivity of 86% and specificity of 77% while the IFA had a sensitivity of 78% and specificity of 85%. The after-treatment screening, through comparative analysis of the technique performance indexes, 1, 2 and 5 years AT, showed an equal performance of the flow cytometry compared with the IFA. However, flow cytometry shows to be a better diagnostic alternative when applied to the study of ATL in the cure criterion. The information obtained in this work opens perspectives to monitor cure after treatment of ATL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Máster Universitario en Sistemas Inteligentes y Aplicaciones Numéricas en Ingeniería (SIANI)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

[ES]Hemos analizado la posible relación entre la presencia de contaminantes emergentes en agua regenerada para riego, agua del lixiviado del suelo y agua subterránea y la resistencia a antibióticos de las bacterias aisladas. Se tomaron muestras de agua. Cada muestra se dividió en dos partes. Una se centrifugó y se resembró en diferentes medios. Cincuenta mililitros de la segunda parte se añadieron a Caldo Brain Heart. En la siembra directa de agua de riego y solución del suelo se detectaron numerosas colonias. El crecimiento en la siembra directa de agua de galería fue escaso, y no hubo crecimiento cuando se sembró agua de pozo. Mediante enriquecimiento en Caldo BHI y resiembra posterior, se obtuvieron numerosas colonias

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction 1.1 Occurrence of polycyclic aromatic hydrocarbons (PAH) in the environment Worldwide industrial and agricultural developments have released a large number of natural and synthetic hazardous compounds into the environment due to careless waste disposal, illegal waste dumping and accidental spills. As a result, there are numerous sites in the world that require cleanup of soils and groundwater. Polycyclic aromatic hydrocarbons (PAHs) are one of the major groups of these contaminants (Da Silva et al., 2003). PAHs constitute a diverse class of organic compounds consisting of two or more aromatic rings with various structural configurations (Prabhu and Phale, 2003). Being a derivative of benzene, PAHs are thermodynamically stable. In addition, these chemicals tend to adhere to particle surfaces, such as soils, because of their low water solubility and strong hydrophobicity, and this results in greater persistence under natural conditions. This persistence coupled with their potential carcinogenicity makes PAHs problematic environmental contaminants (Cerniglia, 1992; Sutherland, 1992). PAHs are widely found in high concentrations at many industrial sites, particularly those associated with petroleum, gas production and wood preserving industries (Wilson and Jones, 1993). 1.2 Remediation technologies Conventional techniques used for the remediation of soil polluted with organic contaminants include excavation of the contaminated soil and disposal to a landfill or capping - containment - of the contaminated areas of a site. These methods have some drawbacks. The first method simply moves the contamination elsewhere and may create significant risks in the excavation, handling and transport of hazardous material. Additionally, it is very difficult and increasingly expensive to find new landfill sites for the final disposal of the material. The cap and containment method is only an interim solution since the contamination remains on site, requiring monitoring and maintenance of the isolation barriers long into the future, with all the associated costs and potential liability. A better approach than these traditional methods is to completely destroy the pollutants, if possible, or transform them into harmless substances. Some technologies that have been used are high-temperature incineration and various types of chemical decomposition (for example, base-catalyzed dechlorination, UV oxidation). However, these methods have significant disadvantages, principally their technological complexity, high cost , and the lack of public acceptance. Bioremediation, on the contrast, is a promising option for the complete removal and destruction of contaminants. 1.3 Bioremediation of PAH contaminated soil & groundwater Bioremediation is the use of living organisms, primarily microorganisms, to degrade or detoxify hazardous wastes into harmless substances such as carbon dioxide, water and cell biomass Most PAHs are biodegradable unter natural conditions (Da Silva et al., 2003; Meysami and Baheri, 2003) and bioremediation for cleanup of PAH wastes has been extensively studied at both laboratory and commercial levels- It has been implemented at a number of contaminated sites, including the cleanup of the Exxon Valdez oil spill in Prince William Sound, Alaska in 1989, the Mega Borg spill off the Texas coast in 1990 and the Burgan Oil Field, Kuwait in 1994 (Purwaningsih, 2002). Different strategies for PAH bioremediation, such as in situ , ex situ or on site bioremediation were developed in recent years. In situ bioremediation is a technique that is applied to soil and groundwater at the site without removing the contaminated soil or groundwater, based on the provision of optimum conditions for microbiological contaminant breakdown.. Ex situ bioremediation of PAHs, on the other hand, is a technique applied to soil and groundwater which has been removed from the site via excavation (soil) or pumping (water). Hazardous contaminants are converted in controlled bioreactors into harmless compounds in an efficient manner. 1.4 Bioavailability of PAH in the subsurface Frequently, PAH contamination in the environment is occurs as contaminants that are sorbed onto soilparticles rather than in phase (NAPL, non aqueous phase liquids). It is known that the biodegradation rate of most PAHs sorbed onto soil is far lower than rates measured in solution cultures of microorganisms with pure solid pollutants (Alexander and Scow, 1989; Hamaker, 1972). It is generally believed that only that fraction of PAHs dissolved in the solution can be metabolized by microorganisms in soil. The amount of contaminant that can be readily taken up and degraded by microorganisms is defined as bioavailability (Bosma et al., 1997; Maier, 2000). Two phenomena have been suggested to cause the low bioavailability of PAHs in soil (Danielsson, 2000). The first one is strong adsorption of the contaminants to the soil constituents which then leads to very slow release rates of contaminants to the aqueous phase. Sorption is often well correlated with soil organic matter content (Means, 1980) and significantly reduces biodegradation (Manilal and Alexander, 1991). The second phenomenon is slow mass transfer of pollutants, such as pore diffusion in the soil aggregates or diffusion in the organic matter in the soil. The complex set of these physical, chemical and biological processes is schematically illustrated in Figure 1. As shown in Figure 1, biodegradation processes are taking place in the soil solution while diffusion processes occur in the narrow pores in and between soil aggregates (Danielsson, 2000). Seemingly contradictory studies can be found in the literature that indicate the rate and final extent of metabolism may be either lower or higher for sorbed PAHs by soil than those for pure PAHs (Van Loosdrecht et al., 1990). These contrasting results demonstrate that the bioavailability of organic contaminants sorbed onto soil is far from being well understood. Besides bioavailability, there are several other factors influencing the rate and extent of biodegradation of PAHs in soil including microbial population characteristics, physical and chemical properties of PAHs and environmental factors (temperature, moisture, pH, degree of contamination). Figure 1: Schematic diagram showing possible rate-limiting processes during bioremediation of hydrophobic organic contaminants in a contaminated soil-water system (not to scale) (Danielsson, 2000). 1.5 Increasing the bioavailability of PAH in soil Attempts to improve the biodegradation of PAHs in soil by increasing their bioavailability include the use of surfactants , solvents or solubility enhancers.. However, introduction of synthetic surfactant may result in the addition of one more pollutant. (Wang and Brusseau, 1993).A study conducted by Mulder et al. showed that the introduction of hydropropyl-ß-cyclodextrin (HPCD), a well-known PAH solubility enhancer, significantly increased the solubilization of PAHs although it did not improve the biodegradation rate of PAHs (Mulder et al., 1998), indicating that further research is required in order to develop a feasible and efficient remediation method. Enhancing the extent of PAHs mass transfer from the soil phase to the liquid might prove an efficient and environmentally low-risk alternative way of addressing the problem of slow PAH biodegradation in soil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mining and processing of metal ores are important causes of soil and groundwater contamination in many regions worldwide. Metal contaminations are a serious risk for the environment and human health. The assessment of metal contaminations in the soil is therefore an important task. A common approach to assess the environmental risk emanating from inorganic contaminations to soil and groundwater is the use of batch or column leaching tests. In this regard, the suitability of leaching tests is a controversial issue. In the first part of this work the applicability and comparability of common leaching tests in the scope of groundwater risk assessment of inorganic contamination is reviewed and critically discussed. Soil water sampling methods (the suction cup method and centrifugation) are addressed as an alternative to leaching tests. Reasons for limitations of the comparability of leaching test results are exposed and recommendations are given for the expedient application of leaching tests for groundwater risk assessment. Leaching tests are usually carried out in open contact with the atmosphere disregarding possible changes of redox conditions. This can affect the original metal speciation and distribution, particularly when anoxic samples are investigated. The influence of sample storage on leaching test results of sulfide bearing anoxic material from a former flotation dump is investigated in a long-term study. Since the oxidation of the sulfide-bearing samples leads to a significant overestimation of metal release, a feasible modification for the conduction of common leaching tests for anoxic material is proposed, where oxidation is prevented efficiently. A comparison of leaching test results to soil water analyzes have shown that the modified saturation soil extraction (SSE) is found to be the only of the tested leaching procedures, which can be recommended for the assessment of current soil water concentrations at anoxic sites if direct investigation of the soil water is impossible due to technical reasons. The vertical distribution and speciation of Zn and Pb in the flotation residues as well as metal concentrations in soil water and plants were investigated to evaluate the environmental risk arising from this site due to the release of metals. The variations in pH and inorganic C content show an acidification of the topsoil with pH values down to 5.5 in the soil and a soil water pH of 6 in 1 m depth. This is due to the oxidation of sulfides and depletion in carbonates. In the anoxic subsoil pH conditions are still neutral and soil water collected with suction cups is in equilibrium with carbonate minerals. Results from extended x-ray absorption fine-structure (EXAFS) spectroscopy confirm that Zn is mainly bound in sphalerite in the subsoil and weathering reactions lead to a redistribution of Zn in the topsoil. A loss of 35% Zn and S from the topsoil compared to the parent material with 10 g/kg Zn has been observed. 13% of total Zn in the topsoil can be regarded as mobile or easily mobilizable according to sequential chemical extractions (SCE). Zn concentrations of 10 mg/L were found in the soil water, where pH is acidic. Electron supply and the buffer capacity of the soil were identified as main factors controlling Zn mobility and release to the groundwater. Variable Pb concentrations up to 30 µg/L were observed in the soil water. In contrast to Zn, Pb is enriched in the mobile fraction of the oxidized topsoil by a factor of 2 compared to the subsoil with 2 g/kg Pb. 80% of the cation exchange capacity in the topsoil is occupied by Pb. Therefore, plant uptake and bioavailability are of major concern. If the site is not prevented from proceeding acidification in the future, a significant release of Zn, S, and Pb to the groundwater has to be expected. Results from this study show that the assessment of metal release especially from sulfide bearing anoxic material requires an extensive comprehension of leaching mechanisms on the one hand and on weathering processes, which influence the speciation and the mobility of metals, on the other hand. Processes, which may change redox and pH conditions in the future, have to be addressed to enable sound decisions for soil and groundwater protection and remediation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Carbonylsulfid (COS) ist eines der stabilsten reduzierten schwefelhaltigen Spurengase in der Atmosphäre. In der gut durchmischten Troposphäre bewegt sich seine Konzentration um 500 ppt. COS spielt eine wichtige Rolle in der Produktion von stratosphärischem Aerosol und im Ozon Zyklus. Dieses Spurengas hat eine Vielfalt an natürlichen und anthropogenen Quellen, denen gleichstarke Senken, darunter die dominanten wie Vegetation und Boden, gegenüber stehen. Die Stärke der Senken ist trotz langjähriger Forschungen immer noch Gegenstand der Diskussionen. Daher ist es wichtig die kontrollierenden Parameter zu charakterisieren. Alle Austauschmessungen vor 1990 vermuteten Böden als Quelle von COS, was aber durch Castro and Galloway (1991) klar widerlegt wurde. Heute werden Böden in Ergänzung zur Vegetation grundsätzlich als Senke betrachtet. Vor diesem Hintergrund wurden Bodenproben auf den Austausch von Carbonylsulfid mit der Atmosphäre unter verschiedenen Umgebungsbedingungen untersucht. Drei Ackerböden aus Deutschland, China und Finnland und zwei Waldböden aus Sibirien und Surinam konnten parametrisiert werden in Relation zur atmosphärischen Umgebungskonzentration, Temperatur und Bodenfeuchte (WC). Neben Umgebungskonzentration und Bodenfeuchte, scheinen Bodenstruktur und enzymatische Aktivität die Richtung und Größe des Austauschflusses zu kontrollieren. Die übereinstimmenden Optima für boreale Böden in Relation zum wassergefüllten Porenvolumen des Bodens (WFPS) und die Linearität zwischen Depositionsgeschwindigkeit (Vd) und Bulk density lassen auf eine Dominanz der Abhängigkeit der COS-Aufnahme von der durch WFPS bestimmten Diffusionsfähigkeit schließen. WFPS ist abhängig von WC, Bodenstruktur und Bodenporosität. In Ergänzung zu diesen eher physikalischen Parametern konnte die Carboanhydrase (CA) als kontrollierendes Enzym in Böden identifiziert werden. Erste Versuche zur direkten Bestimmung der CA in den untersuchten Böden erlaubten eine erste, aber noch sehr ungenaue Abschätzung der Enzymaktivität.