972 resultados para Scotchbond Multi-Purpose Plus
Resumo:
For the past decade, numerous imaging techniques gave rise to remarka-ble progresses in the understanding of brain’s structure and function. Amongst the wide variety of studies onto the field of neuroscience, neuropsychiatric re-searches with resource to neuroimaging have attracted increasing attention. The present study will focus on the identification of brain areas recruited while normative subjects read sentences related to past/present or future wor-ries. Our main aim was to accurately characterize these brain areas while providing them with a time-stamp that would hopefully help us understand the implications of past/present memories and future envisioning in worrying episodes. With that purpose, functional magnetic resonance imaging data was collected from ten healthy individuals. The obtained data was processed and statistically treated using the General Linear Model and both Fixed and Ran-dom Effects Analysis for group-level results. Thereafter, a Multi-Voxel Pattern Analysis with Searchlight Mapping was performed in order to find patterns of activation that allow differentiation between conditions. The obtained results indicate higher brain activation while reading sen-tences related to past/present worries when compared to future worry or neu-tral sentences. The main areas include frontal cortex, posterior parietal, occipital and temporal areas. Worrying, per se, was characterized by activation of the medial posterior parietal cortex, left posterior occipital lobe and left central temporal lobe. With the searchlight mapping approach we were able to further identify patterns of distinction between conditions, which were located in the parietal, limbic and frontal lobes.
Resumo:
RESUMO: O cancro de mama e o mais frequente diagnoticado a indiv duos do sexo feminino. O conhecimento cientifico e a tecnologia tem permitido a cria ção de muitas e diferentes estrat egias para tratar esta patologia. A Radioterapia (RT) est a entre as diretrizes atuais para a maioria dos tratamentos de cancro de mama. No entanto, a radia ção e como uma arma de dois canos: apesar de tratar, pode ser indutora de neoplasias secund arias. A mama contralateral (CLB) e um orgão susceptivel de absorver doses com o tratamento da outra mama, potenciando o risco de desenvolver um tumor secund ario. Nos departamentos de radioterapia tem sido implementadas novas tecnicas relacionadas com a radia ção, com complexas estrat egias de administra ção da dose e resultados promissores. No entanto, algumas questões precisam de ser devidamente colocadas, tais como: E seguro avançar para tecnicas complexas para obter melhores indices de conformidade nos volumes alvo, em radioterapia de mama? O que acontece aos volumes alvo e aos tecidos saudaveis adjacentes? Quão exata e a administração de dose? Quais são as limitações e vantagens das técnicas e algoritmos atualmente usados? A resposta a estas questões e conseguida recorrendo a m etodos de Monte Carlo para modelar com precisão os diferentes componentes do equipamento produtor de radia ção(alvos, ltros, colimadores, etc), a m de obter uma descri cão apropriada dos campos de radia cão usados, bem como uma representa ção geometrica detalhada e a composição dos materiais que constituem os orgãos e os tecidos envolvidos. Este trabalho visa investigar o impacto de tratar cancro de mama esquerda usando diferentes tecnicas de radioterapia f-IMRT (intensidade modulada por planeamento direto), IMRT por planeamento inverso (IMRT2, usando 2 feixes; IMRT5, com 5 feixes) e DCART (arco conformacional dinamico) e os seus impactos em irradia ção da mama e na irradia ção indesejada dos tecidos saud aveis adjacentes. Dois algoritmos do sistema de planeamento iPlan da BrainLAB foram usados: Pencil Beam Convolution (PBC) e Monte Carlo comercial iMC. Foi ainda usado um modelo de Monte Carlo criado para o acelerador usado (Trilogy da VARIAN Medical Systems), no c odigo EGSnrc MC, para determinar as doses depositadas na mama contralateral. Para atingir este objetivo foi necess ario modelar o novo colimador multi-laminas High- De nition que nunca antes havia sido simulado. O modelo desenvolvido est a agora disponí vel no pacote do c odigo EGSnrc MC do National Research Council Canada (NRC). O acelerador simulado foi validado com medidas realizadas em agua e posteriormente com c alculos realizados no sistema de planeamento (TPS).As distribui ções de dose no volume alvo (PTV) e a dose nos orgãos de risco (OAR) foram comparadas atrav es da an alise de histogramas de dose-volume; an alise estati stica complementar foi realizadas usando o software IBM SPSS v20. Para o algoritmo PBC, todas as tecnicas proporcionaram uma cobertura adequada do PTV. No entanto, foram encontradas diferen cas estatisticamente significativas entre as t ecnicas, no PTV, nos OAR e ainda no padrão da distribui ção de dose pelos tecidos sãos. IMRT5 e DCART contribuem para maior dispersão de doses baixas pelos tecidos normais, mama direita, pulmão direito, cora cão e at e pelo pulmão esquerdo, quando comparados com as tecnicas tangenciais (f-IMRT e IMRT2). No entanto, os planos de IMRT5 melhoram a distribuição de dose no PTV apresentando melhor conformidade e homogeneidade no volume alvo e percentagens de dose mais baixas nos orgãos do mesmo lado. A t ecnica de DCART não apresenta vantagens comparativamente com as restantes t ecnicas investigadas. Foram tamb em identi cadas diferen cas entre os algoritmos de c alculos: em geral, o PBC estimou doses mais elevadas para o PTV, pulmão esquerdo e cora ção, do que os algoritmos de MC. Os algoritmos de MC, entre si, apresentaram resultados semelhantes (com dferen cas at e 2%). Considera-se que o PBC não e preciso na determina ção de dose em meios homog eneos e na região de build-up. Nesse sentido, atualmente na cl nica, a equipa da F sica realiza medi ções para adquirir dados para outro algoritmo de c alculo. Apesar de melhor homogeneidade e conformidade no PTV considera-se que h a um aumento de risco de cancro na mama contralateral quando se utilizam t ecnicas não-tangenciais. Os resultados globais dos estudos apresentados confirmam o excelente poder de previsão com precisão na determinação e c alculo das distribui ções de dose nos orgãos e tecidos das tecnicas de simulação de Monte Carlo usados.---------ABSTRACT:Breast cancer is the most frequent in women. Scienti c knowledge and technology have created many and di erent strategies to treat this pathology. Radiotherapy (RT) is in the actual standard guidelines for most of breast cancer treatments. However, radiation is a two-sword weapon: although it may heal cancer, it may also induce secondary cancer. The contralateral breast (CLB) is a susceptible organ to absorb doses with the treatment of the other breast, being at signi cant risk to develop a secondary tumor. New radiation related techniques, with more complex delivery strategies and promising results are being implemented and used in radiotherapy departments. However some questions have to be properly addressed, such as: Is it safe to move to complex techniques to achieve better conformation in the target volumes, in breast radiotherapy? What happens to the target volumes and surrounding healthy tissues? How accurate is dose delivery? What are the shortcomings and limitations of currently used treatment planning systems (TPS)? The answers to these questions largely rely in the use of Monte Carlo (MC) simulations using state-of-the-art computer programs to accurately model the di erent components of the equipment (target, lters, collimators, etc.) and obtain an adequate description of the radiation elds used, as well as the detailed geometric representation and material composition of organs and tissues. This work aims at investigating the impact of treating left breast cancer using di erent radiation therapy (RT) techniques f-IMRT (forwardly-planned intensity-modulated), inversely-planned IMRT (IMRT2, using 2 beams; IMRT5, using 5 beams) and dynamic conformal arc (DCART) RT and their e ects on the whole-breast irradiation and in the undesirable irradiation of the surrounding healthy tissues. Two algorithms of iPlan BrainLAB TPS were used: Pencil Beam Convolution (PBC)and commercial Monte Carlo (iMC). Furthermore, an accurate Monte Carlo (MC) model of the linear accelerator used (a Trilogy R VARIANR) was done with the EGSnrc MC code, to accurately determine the doses that reach the CLB. For this purpose it was necessary to model the new High De nition multileaf collimator that had never before been simulated. The model developed was then included on the EGSnrc MC package of National Research Council Canada (NRC). The linac was benchmarked with water measurements and later on validated against the TPS calculations. The dose distributions in the planning target volume (PTV) and the dose to the organs at risk (OAR) were compared analyzing dose-volume histograms; further statistical analysis was performed using IBM SPSS v20 software. For PBC, all the techniques provided adequate coverage of the PTV. However, statistically significant dose di erences were observed between the techniques, in the PTV, OAR and also in the pattern of dose distribution spreading into normal tissues. IMRT5 and DCART spread low doses into greater volumes of normal tissue, right breast, right lung, heart and even the left lung than tangential techniques (f-IMRT and IMRT2). However,IMRT5 plans improved distributions for the PTV, exhibiting better conformity and homogeneity in target and reduced high dose percentages in ipsilateral OAR. DCART did not present advantages over any of the techniques investigated. Di erences were also found comparing the calculation algorithms: PBC estimated higher doses for the PTV, ipsilateral lung and heart than the MC algorithms predicted. The MC algorithms presented similar results (within 2% di erences). The PBC algorithm was considered not accurate in determining the dose in heterogeneous media and in build-up regions. Therefore, a major e ort is being done at the clinic to acquire data to move from PBC to another calculation algorithm. Despite better PTV homogeneity and conformity there is an increased risk of CLB cancer development, when using non-tangential techniques. The overall results of the studies performed con rm the outstanding predictive power and accuracy in the assessment and calculation of dose distributions in organs and tissues rendered possible by the utilization and implementation of MC simulation techniques in RT TPS.
Resumo:
Nesta dissertação é realizado o estudo de um motor em disco polifásico com armadura convencional e rotor que pode ser convencional, em alumínio, ou composto por material supercondutor de alta temperatura multi‐semente. O motor com o rotor em alumínio apresenta um comportamento assíncrono bem definido, baseado na lei geral de indução de eletromotrizes no induzido. Contudo, ao ser mergulhado em azoto líquido, evidencia melhores características eléctricas, tanto do induzido como do indutor, mesmo que o núcleo ferromagnético convencional possa exibir degradação magnética. O motor com o rotor SAT exibe um comportamento distinto, evidenciando ambos os regimes síncrono e assíncrono estáveis. O regime síncrono fica caracterizado pelo fenómeno de aprisionamento de campo, que garante que o rotor gire síncrono com o campo girante do estator. Em regime assíncrono, para um determinado valor de binário resistente aplicado superior ao electromagnético máximo desenvolvido pelo motor, o fenómeno de escoamento de campo está presente, sendo o binário electromagnético motor reforçado por um binário extra de perdas de carácter resistivo desenvolvidas no rotor devido à interacção da densidade de corrente a campos eléctricos que se estabelecem no rotor. Neste caso, o fenómeno de escoamento de campo não é devido a forças de Lorentz que se definem na matriz de Abrikosov, mas sim devido a esta ser “puxada” pelo campo girante do estator, ficando a matriz a deslizar sobre o rotor. De modo a obter as características dos sistemas electromecânicos em estudo é realizada uma análise teórica, baseada na teoria convencional das máquinas eléctricas, com o objectivo de compreender alguns dos fenómenos do motor de fluxo axial, e uma análise baseada num programa comercial de elementos finitos onde o fenómeno da supercondutividade é simulado com base na relação entre o campo elétrico e a densidade de corrente pela lei da potenciação (E‐J power law). O ensaio dos motores referidos é realizado para comparar ambos os sistemas e de realçar o princípio de funcionamento e as características mais relevantes de cada um. Da análise realizada é desenvolvido um modelo que caracteriza o funcionamento da máquina com o rotor com SAT.
Resumo:
The Intel R Xeon PhiTM is the first processor based on Intel’s MIC (Many Integrated Cores) architecture. It is a co-processor specially tailored for data-parallel computations, whose basic architectural design is similar to the ones of GPUs (Graphics Processing Units), leveraging the use of many integrated low computational cores to perform parallel computations. The main novelty of the MIC architecture, relatively to GPUs, is its compatibility with the Intel x86 architecture. This enables the use of many of the tools commonly available for the parallel programming of x86-based architectures, which may lead to a smaller learning curve. However, programming the Xeon Phi still entails aspects intrinsic to accelerator-based computing, in general, and to the MIC architecture, in particular. In this thesis we advocate the use of algorithmic skeletons for programming the Xeon Phi. Algorithmic skeletons abstract the complexity inherent to parallel programming, hiding details such as resource management, parallel decomposition, inter-execution flow communication, thus removing these concerns from the programmer’s mind. In this context, the goal of the thesis is to lay the foundations for the development of a simple but powerful and efficient skeleton framework for the programming of the Xeon Phi processor. For this purpose we build upon Marrow, an existing framework for the orchestration of OpenCLTM computations in multi-GPU and CPU environments. We extend Marrow to execute both OpenCL and C++ parallel computations on the Xeon Phi. We evaluate the newly developed framework, several well-known benchmarks, like Saxpy and N-Body, will be used to compare, not only its performance to the existing framework when executing on the co-processor, but also to assess the performance on the Xeon Phi versus a multi-GPU environment.
Resumo:
This dissertation aims to guarantee the integration of a mobile autonomous robot equipped with many sensors in a multi-agent distributed and georeferenced surveillance system. The integration of a mobile autonomous robot in this system leads to new features that will be available to clients of surveillance system may use. These features may be of two types: using the robot as an agent that will act in the environment or by using the robot as a mobile set of sensors. As an agent in the system, the robot can move to certain locations when alerts are received, in order to acknowledge the underlying events or take to action in order to assist in resolving this event. As a sensor platform in the system, it is possible to access information that is read from the sensors of the robot and access complementary measurements to the ones taken by other sensors in the multi-agent system. To integrate this mobile robot in an effective way it is necessary to extend the current multi-agent system architecture to make the connection between the two systems and to integrate the functionalities provided by the robot into the multi-agent system.
Resumo:
Double degree. A Work Project presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA- School of Business and Economics and Warsaw School of Economics
Resumo:
Environmental pollution is one of the major and most important problems of the modern world. In order to fulfill the needs and demands of the overgrowing human population, developments in agriculture, medicine, energy sources, and all chemical industries are necessary (Ali 2010). Over the last century, the increased industrialization and continued population growth led to an augmented production of environmental pollutants that are released into air, water, and soil, with significant impact in the degradation of various ecosystems (Ali 2010, Khan et al. 2013).(...)
Resumo:
RESUMO: Introdução: Uma meta-análise recente demonstrou que uso adjuvante de ácido zoledrónico (AZ) em mulheres pós-menopáusicas com cancro da mama precoce (CM) conduz a redução do risco de morte por CM em 17%. Investigámos o efeito do estado hormonal (pré [PrM] vs pós-menopausa tardia [PoM]) na remodelação óssea e controlo de doença em mulheres com CM e metástases ósseas (MO) tratadas com AZ e quimioterapia (QT). Métodos: Neste estudo de coorte retrospetivo, colhemos variáveis clinico-patológicas e quantificámos o telopéptido N-terminal (NTX) urinário e marcadores tumorais (MT) séricos em mulheres com CM e MO tratadas com QT e AZ. As doentes foram divididas em PrM (<45 anos) e PoM (>60 anos). Endpoints do estudo: variação do NTX, CA15.3 e CEA nos meses 3, 6 e 9, tempo até falência de QT de primeira-linha e sobrevivência. Quando apropriado foram usados os testes de Wilcoxon rank-sum, modelo de efeitos lineares mistos, teste log-rank e modelo de Cox. Resultados: Quarenta doentes foram elegíveis para análise (8 PrM e 32 PoM). Depois da introdução de AZ e QT, os níveis de NTX e MT caíram no coorte global. O perfil de resposta não diferiu entre grupos no mês 3 ou em tempos posteriores (valor-p para interação tempo-estado hormonal no mês 3=0.957). Ademais, o perfil de resposta dos MT também não diferiu entre grupos. O tempo mediano até falência de primeira-linha de QT em PrM e PoM foi de 15.2 e 17.4 meses, respetivamente. Não foi identificada diferença significativa entre grupos, quer em análise univariada quer após controlo para envolvimento visceral (p=0.399 e 0.469, respetivamente). Igualmente, não houve diferenças em termos de sobrevivência. Conclusões: Neste coorte, não foram identificadas diferenças no controlo de NTX ou MT em função do estado menopausico. Igualmente, não foi identificada diferença no tempo até falência de primeira-linha de CT ou sobrevivência.----------- ABSTRACT: Background: A recent meta-analysis showed that the adjuvant use of zoledronic acid (ZA) in postmenopausal women with early breast cancer (BC) leads to a reduction in the risk of breast cancer death by 17%. We investigated the effect of the hormonal status (pre [PrM] vs late post menopause [PoM]) on bone turnover and disease control among women with BC and boné metastases (BM) treated with ZA and chemotherapy (CT). Methods: In this retrospective cohort study, we collected clinicopathologic variables, urinary Nterminal telopeptide (NTX) and serum tumor marker levels from women with BC and BM treated with CT and ZA. Patients were divided in PrM (<45 years) and PoM (>60 years). Study endpoints were NTX, CA15.3 and CEA variation at 3, 6 and 9 months, and time to first-line CT failure and survival. We performed multilevel mixed-effects linear regression models to assess the variation of repeated measures and cox regression models for time to event outcomes. Results: Forty patients were eligible for analysis (8 PrM and 32 PoM). After introduction of ZA and CT, NTX and tumor markers declined in the overall cohort. Response profile was similar between menopausal groups at month 3 and at later time points (p-value for time-hormonal status interaction at month 3=0.957). Furthermore, tumor markers response profile was also equal between groups. Median time to first-line CT failure in PrM and PoM women was 15.2 and 17.4 months, respectively. No significant difference between groups was found, either using a univariate analysis or after controlling for visceral disease involvement (p=0.399 and 0.469, respectively). Likewise, no differences in survival were found. Conclusions: In this cohort, no differences were found in terms of NTX or tumor markers control according to menopausal status. Similarly, no difference in time to first-line CT failure or survival was found.
Resumo:
The following work project illustrates the strategic issues There App, a mobile application, faces regarding the opportunity to expand from its current state as a product to a multisided platform. Initially, a market analysis is performed to identify the ideal customer groups to be integrated in the platform. Strategic design issues are then discussed on how to best match its value proposition with the identified market opportunity. Suggestions on how the company should organize its resources and operational processes to best deliver on its value proposition complete the work.
Resumo:
The need for more efficient illumination systems has led to the proliferation of Solid-State Lighting (SSL) systems, which offer optimized power consumption. SSL systems are comprised of LED devices which are intrinsically fast devices and permit very fast light modulation. This, along with the congestion of the radio frequency spectrum has paved the path for the emergence of Visible Light Communication (VLC) systems. VLC uses free space to convey information by using light modulation. Notwithstanding, as VLC systems proliferate and cost competitiveness ensues, there are two important aspects to be considered. State-of-the-art VLC implementations use power demanding PAs, and thus it is important to investigate if regular, existent Switched-Mode Power Supply (SMPS) circuits can be adapted for VLC use. A 28 W buck regulator was implemented using a off-the-shelf LED Driver integrated circuit, using both series and parallel dimming techniques. Results show that optical clock frequencies up to 500 kHz are achievable without any major modification besides adequate component sizing. The use of an LED as a sensor was investigated, in a short-range, low-data-rate perspective. Results show successful communication in an LED-to-LED configuration, with enhanced range when using LED strings as sensors. Besides, LEDs present spectral selective sensitivity, which makes them good contenders for a multi-colour LED-to-LED system, such as in the use of RGB displays and lamps. Ultimately, the present work shows evidence that LEDs can be used as a dual-purpose device, enabling not only illumination, but also bi-directional data communication.
Resumo:
An energy harvesting system requires an energy storing device to store the energy retrieved from the surrounding environment. This can either be a rechargeable battery or a supercapcitor. Due to the limited lifetime of rechargeable batteries, they need to be periodically replaced. Therefore, a supercapacitor, which has ideally a limitless number of charge/discharge cycles can be used to store the energy; however, a voltage regulator is required to obtain a constant output voltage as the supercapacitor discharges. This can be implemented by a Switched-Capacitor DC-DC converter which allows a complete integration in CMOS technology, although it requires several topologies in order to obtain a high efficiency. This thesis presents the complete analysis of four different topologies in order to determine expressions that allow to design and determine the optimum input voltage ranges for each topology. To better understand the parasitic effects, the implementation of the capacitors and the non-ideal effect of the switches, in 130 nm technology, were carefully studied. With these two analysis a multi-ratio SC DC-DC converter was designed with an output power of 2 mW, maximum efficiency of 77%, and a maximum output ripple, in the steady state, of 23 mV; for an input voltage swing of 2.3 V to 0.85 V. This proposed converter has four operation states that perform the conversion ratios of 1/2, 2/3, 1/1 and 3/2 and its clock frequency is automatically adjusted to produce a stable output voltage of 1 V. These features are implemented through two distinct controller circuits that use asynchronous time machines (ASM) to dynamically adjust the clock frequency and to select the active state of the converter. All the theoretical expressions as well as the behaviour of the whole system was verified using electrical simulations.
Resumo:
The evolution of receiver architectures, built in modern CMOS technologies, allows the design of high efficient receivers. A key block in modern receivers is the oscillator. The main objective of this thesis is to design a very low power and low area 8-Phase Ring Oscillator for biomedical applications (ISM and WMTS bands). Oscillators with multiphase outputs and variable duty cycles are required. In this thesis we are focused in 12.5% and 50% duty-cycles approaches. The proposed circuit uses eight inverters in a ring structure, in order to generate the output duty cycle of 50%. The duty cycle of 1/8 is achieved through the combination of the longer duty cycle signals in pairs, using, for this purpose, NAND gates. Since the general application are not only the wireless communications context, as well as industrial, scientific and medical plans, the 8-Phase Oscillator is simulated to be wideband between 100 MHz and 1 GHz, and be able to operate in the ISM bands (447 MHz-930 MHz) and WMTS (600 MHz). The circuit prototype is designed in UMC 130 nm CMOS technology. The maximum value of current drawn from a DC power source of 1.2 V, at a maximum frequency of 930 MHz achieved, is 17.54 mA. After completion of the oscillator layout studied (occupied area is 165 μm x 83 μm). Measurement results confirm the expected operating range from the simulations, and therefore, that the oscillator fulfil effectively the goals initially proposed in order to be used as Local Oscillator in RF Modern Receivers.