952 resultados para Retaining wall. Instrumentation. Anchors
Resumo:
As compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were submitted to dynamic bending testing in stainless-steel simulated curved canals. Axial displacement of the simulated canals was performed with half of the instruments (n = 10), with back-and-forth movements in a range of 1.5 mm. Time until fracture was recorded, and the number of cycles until instrument fracture was calculated. Cyclic fatigue resistance was greater for reciprocating systems than for rotary systems (P < 0.05). Instruments from the Reciproc and WaveOne systems significantly differed only when axial displacement occurred (P < 0.05). Instruments of the ProTaper Universal and MTwo systems did not significantly differ (P > 0.05). Cyclic fatigue and torsional resistance were greater for reciprocating systems than for continuous rotary systems, irrespective of axial displacement.
Resumo:
This article consists in a discourse analysis of the feature film in animation Wall.e produced by Pixar in association to Disney in 2008. Pixar has been known to produce films that contain various discursive levels, making its products appealing not only for children, but also for adults. However, Wall-e proves to be a masterpiece in Pixar carrier, because it is the one which focuses on the analysis and critique of contemporary society associated with technological development. For this, the plot has as its starting point the question of sustainability and unbridled consumerism. But the film expands the debate, tracing the relationship between technology and humanity, discussing how one affects the other. The project therefore aims to show how the animation works such concepts and constructs his discourse. To this end, the work seeks to identify the signs that make up the discourse and draw the intertextuality between WALL.E and other works that also discuss the same elements such as Stanley Kubrick‟s 2001 - A Space Odyssey (1968)
Resumo:
Population growth, together with the gradual social ascent in Brazil, reflects at the growing need for better use of urban spaces. In this context, the amount of new buildings to meet the demand in property market, the needs for creating new roads and highways, among others, make the use of geotechnical works and, more specifically, retaining walls, more and more common. One of the simplest solutions for underground works is the use of retaining structures using tie back walls for soil support, therefore, the present work deals with this kind of structures. This paper proposes the use of FTOOL software testing in predicting deformations in tie back walls, by comparing simulations of the presented model to a real and measured deformation case in Guabirotuba Formation (PR). The results showed the importance of defining the parameters such as stiffness and curtain geometry, as well as the definition of representative loads acting on it. Also, it was pointed out that the passive response of the steel rods depends on the horizontal displacement of the wall. The study concluded that the program generates very representative results when compared to field data and seems to be a promising tool for tie back structures displacement predictions
Resumo:
Endometriosis is a continuous and progressive disease with a poorly understood aetiology, pathophysiology and natural history. This study evaluated the histological differences between eutopic and ectopic endometria (abdominal wall endometriosis) and the expression of mast cell proteases (tryptase and chymase), annexin A1 (ANXA1) and formyl peptide receptor 1 (FPR1). Ectopic endometrium from 18 women with abdominal wall endometriosis and eutopic endometrium from 10 women without endometriosis were obtained. The endometrial samples were analysed by histopathology, immunohistochemistry and ultrastructural immunogold labeling to determine mast cell heterogeneity (tryptase and chymase positive cells) and the expression levels of ANXA1 and FPR1. Histopathological analysis of the endometriotic lesions showed a glandular pattern of mixed differentiation and an undifferentiated morphology with a significant influx of inflammatory cells and a change in mast cell heterogeneity, as evidenced by a significant increase in the number of chymase-positive cells and endogenous chymase expression. The undifferentiated glandular pattern of endometriotic lesions was positively associated with a marked increase and co-localization of ANXA1 and FPR1 in the epithelial cells. In conclusion, the co-upregulated expression of mast cell chymase and ANXA1–FPR1 system in ectopic endometrium suggests their involvement in the development of endometriotic lesions.
Resumo:
The aim of this study was to evaluate the efficacy and safety of traumatic orbital defect reconstruction with titanium mesh. A retrospective study was made. Evaluations were made after a minimum postoperative follow-up of 12 months, looking for the main complications. Twenty-four patients were included in this evaluation; 19 were male (79.1%) and 5 (20.8%) were female. The main injury etiology was vehicle accidents (50%) followed by other causes. Fourteen patients (58.3%) presented orbital floor fractures, and 10 had more than one wall fractured (41.6%). Permanent infraorbital nerve hypoesthesia was observed in two patients (8.3%), enophthalmos occurred in five patients (20.8%), and exophthalmos was found in two patients (8.3%). Four patients (16.6%) still presented evidence of residual prolapsed intraorbital content, and one of those needed further surgical correction; sinusitis occurred in one patient (4.1%). Titanium mesh is a reliable option for orbital reconstruction, despite some complications found in this sample.
Resumo:
The aim of this study was to review the literature on the systems used to decontaminate the implant's surface. Different instruments have been proposed, but there is no agreement in the literature about which methods would be more efficient with no damage to the implant surface. It was reported the use of plastic, carbon fiber, stainless-steel and titanium curettes and also the use of other systems such as ultrasonic points with different tips, rubber cups and air abrasion. Literature review: In most of the studies, the injury caused on the titanium surface at the time of instrumentation was examined. In others, the cell adhesion on the titanium dental implants following instrumentation of the implant surface was observed. Moreover, to enhance cleaning around implants, ultrasonic systems were recently tested. Conclusion: Metal instruments can lead to major damage to implant surface, therefore, they are not indicated for decontamination of dental implants surfaces. Furthermore, non-metallic instruments, such as plastic curettes, rubber cups, air abrasion and some ultrasonic systems seem to be better choices to remove calculus and plaque of the sub- and supra-gingival peri-implant area. It is noteworthy that more studies evaluating the effects of these systems are required to establish best practices to be used in the treatment of patients with dental implants.
Resumo:
Purpose: The purpose of this study was to evaluate the increase of the cervical area and dentin thickness in mesial and distal walls of the mesial canals from mandibular molars after the use of LA Axxess (LA), CP Drill (CP) and Gates-Glidden (GG) rotary instruments. Material and Methods: Sixty root canals from thirty mandibular first molar were sectioned 3 mm below the cement-enamel junction, divided in 3 groups (n = 20 root canals, each) according to rotary instrument used, and the cervical images were captured before and after pre-enlargement instrumentation. The increase of the instrumented cervical area (mm2) and the dentin removal thickness (mm), at mesial and distal walls were calculated using Image tools software, by comparison of images. Data were analyzed by ANOVA and Tukey tests (p=0.05). Results: All rotary instruments promoted thickness reduction in dentin walls. In mesial wall, all rotary instruments promoted similar thickness reduction of dentinal wall and did not differ from each other (p>0.05). In distal wall, LA Axxess instrument promoted higher dentin thickness reduction than other groups (p<0.05). The three rotary instruments promoted different increase at the instrumented cervical area (p<0.05), LA promoted the highest increase area and GG and CP presented similar results. Conclusion: LA 20/0.06 promoted the highest thickness reduction in distal wall and increase of cervical area of root canal. On the other hand, CP was the safest instrument, with lower dentin removal of distal wall and similar increased area to GG.
Resumo:
To evaluate the influence of variations in the working angle of the piezoelectric ultrasonic scaler (PUS) on root surfaces. Material and methods Fifty-five uniradicular bovine teeth were used, of which 25 teeth were used for the analysis of the roughness and root wear, while the remaining 30 teeth were used for the analysis of morphology (MRS) and the attachment of blood components (ABC). The teeth were randomly divided into five groups according to the type of treatment (G1-G5: piezoelectric ultrasonic scaler; G6: manual curette) and to the PUS working angle applied (G1: 0°; G2: 30°; G3: 45°; G4: 60°; G5: 90°). For statistical analysis, the data describing the MRS and ABC were analysed by the Kruskal–Wallis and Dunn's tests, and the data describing the roughness and tooth wear were analysed by anova and Tukey's tests at the significance level of 5%. Results Manual curette (MC) promoted a smoother root surface than the application of the PUS. The PUS used at the angles of 30° and 45° resulted in a high level of ABC that was comparable to that obtained by MC. Additionally, the group in which the PUS was applied at an angle of 45° exhibited less tooth wear than the other groups. Conclusions Changes in the working angle of the PUS influenced the characteristics of root surfaces after instrumentation.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to assess the cleaning capacity of the Protaper system using motor-driven or manual instrumentation. Materials and Methods: Ten mandibular molars were randomly separated into 2 groups (n = 5) according to the type of instrumentation performed, as follows: Group 1 - instrumentation with rotary nickel-titanium (Ni-Ti) files using ProTaper Universal System (Dentsply/Maillefer); and, Group 2 - instrumentation with Ni-Ti hand files using ProTaper Universal (Dentsply-Maillefer). Afterwards, the teeth were sectioned transversely and submitted to histotechnical processing to obtain histological sections for microscopic evaluation. The images were analyzed by the Corel Photo-Paint X5 program (Corel Corporation) using an integration grid superimposed on the image. Results: Statistical analysis (U-Mann-Whitney - P < 0.05) demonstrated that G1 presented higher cleaning capacity when compared to G2. Conclusions: The rotary technique presented better cleaning results in the apical third of the root canal system when compared to the manual technique.
Resumo:
The purpose of this study was to evaluate the repair process in the reconstruction of the anterior wall of the frontal sinus of monkeys with bovine bone matrix. Four adult Cebus apella monkeys underwent an ostectomy of the anterior wall of the frontal sinus. The frontal sinus mucosa and the nasofrontal duct were not manipulated. Reconstruction occurred with implants of bovine bone matrix laminae measuring 2.0 x 2.5 cm and 0.4 mm thick, stabilized under pressure in the lateral wall of the frontal sinus. The monkeys were sacrificed over a period of 150 days and routine laboratory procedures were followed for hematoxylin-eosin staining and histologic evaluation of the specimens. Neoformed bone tissue was observed in contact with the frontal sinus mucosa and the bovine bone matrix. The frontal sinus mucosa remained whole without fibrous tissue or cystic formations. There was no occurrence of cellularization as well as revascularization of the bovine bone matrix, though it has permitted bone conduction on this surface. It was possible to conclude that the demineralized bovine bone matrix was biotolerable, being incorporated into the bone without the presence of inflammatory cells with characteristics of inertness and antigenicity and behaved as an osteoconductive material.
Resumo:
Few studies has been done using guided bone regeneration in maxillary sinus defects. AIM: To assess the bone repair process in surgical defects on the alveolar wall of the monkey maxillary sinus, which communicates with the sinus cavity, by using collagen membranes: Gen-derm - Genius Baumer, Pro-tape - Proline and autologous temporal fascia. MATERIALS AND METHODS: In this prospective and experimental study, orosinusal communications were performed in four tufted capuchin monkeys (Cebus apella) and histologic analysis was carried out 180 days after. RESULTS: In the defects without a cover (control), bone proliferation predominated in two animals and fibrous connective tissue predominated in the other two. In defects repaired with a temporal fascia flap, fibrous connective tissue predominated in three animals and bone proliferation predominated in one. In the defects repaired with Gen-derm or Pro-tape collagen membranes there was complete bone proliferation in three animals and fibrous connective tissue in one. CONCLUSIONS: Surgical defect can be repaired with both bone tissue and fibrous connective tissue in all study groups; collagen membranes was more beneficial in the bone repair process than temporal fascia or absence of a barrier.
Resumo:
This paper refers to the design of an expert system that captures a waveform through the use of an accelerometer, processes the signal and converts it to the frequency domain using a Fast Fourier Transformer to then, using artificial intelligence techniques, specifically Fuzzy Reasoning, it determines if there is any failure present in the underlying mode of the equipment, such as imbalance, misalignment or bearing defects.