993 resultados para Recovery technique
Resumo:
OBJECTIVE: Skeletal Muscle Biopsy is a minor surgical procedure for the diagnosis of different neuromuscular pathological conditions and has recently gained popularity also in the research field of age-related muscular modifications and sarcopenia. Few studies focused on the application of mini-invasive muscular biopsy in both normal and pathological conditions. The aim of our study was to describe a mini invasive ultrasound-guided skeletal muscular biopsy technique in complete spinal cord injured (SCI) patients and healthy controls with a tri-axial end-cut needle. PATIENTS AND METHODS: Skeletal muscle biopsies were collected from 6 chronic SCI patients and 3 healthy controls vastus lateralis muscle with a tri-axial end cut needle (Biopince© - Angiotech). Muscle samples were stained for ATPase to determine fibers composition, moreover, gene expression of cyclooxygenase-1 (COX-1) and prostaglandin E2 receptor has been analyzed by Real Time RT-PCR. RESULTS: All the procedures were perfomed easily without failures and complications. Control tissue was macroscopically thicker than SCI one. Control specimen displayed an equal distribution of type I and type II fibers, while SCI sample displayed a prevalence of type II fibers SCI specimen displayed a significant reduction in COX-1 gene expression. This mini-invasive approach was easy, accurate and with low complication rate in performing skeletal muscle biopsy in both SCI patients and controls. CONCLUSIONS: This technique could be useful in conditions in which the overall quantity of specimen required is small like for molecular biology analysis. For histological diagnostic purposes and/or conditions in which the original tissue is already pathologically modified, this technique should be integrated with more invasive techniques.
Resumo:
BACKGROUND: The objective measurement of dominant/nondominant arm use proportion in daily life may provide relevant information on healthy and pathologic arm behavior. This prospective case-control study explored the potential of such measurements as indicators of upper limb functional recovery after rotator cuff surgery. METHODS: Data on dominant/nondominant arm usage were acquired with body-worn sensors for 7 hours. The postsurgical arm usage of 21 patients was collected at 3, 6, and 12 months after rotator cuff surgery in the sitting, walking, and standing postures and compared with a reference established with 41 healthy subjects. The results were calculated for the dominant and nondominant surgical side subgroups at all stages. The correlations with clinical scores were calculated. RESULTS: Healthy right-handed and left-handed dominant arm usage was 60.2% (±6.3%) and 53.4% (±6.6%), respectively. Differences in use of the dominant side were significant between the right- and left-handed subgroups for sitting (P = .014) and standing (P = .009) but not for walking (P = .328). The patient group showed a significant underuse of 10.7% (±8.9%) at 3 months after surgery (P < .001). The patients recovered normal arm usage within 12 months, regardless of surgical side. The arm underuse measurement was weakly related to function and pain scores. CONCLUSION: This study provided new information on arm recovery after rotator cuff surgery using an innovative measurement method. It highlighted that objective arm underuse measurement is a valuable indicator of upper limb postsurgical outcome that captures a complementary feature to clinical scores.
Resumo:
To improve our understanding of the limiting factors during repeated sprinting, we manipulated hypoxia severity during an initial set and examined the effects on performance and associated neuro-mechanical alterations during a subsequent set performed in normoxia. On separate days, 13 active males performed eight 5-s sprints (recovery = 25 s) on an instrumented treadmill in either normoxia near sea-level (SL; FiO2 = 20.9%), moderate (MH; FiO2 = 16.8%) or severe normobaric hypoxia (SH; FiO2 = 13.3%) followed, 6 min later, by four 5-s sprints (recovery = 25 s) in normoxia. Throughout the first set, along with distance covered [larger sprint decrement score in SH (-8.2%) compared to SL (-5.3%) and MH (-7.2%); P < 0.05], changes in contact time, step frequency and root mean square activity (surface electromyography) of the quadriceps (Rectus femoris muscle) in SH exceeded those in SL and MH (P < 0.05). During first sprint of the subsequent normoxic set, the distance covered (99.6, 96.4, and 98.3% of sprint 1 in SL, MH, and SH, respectively), the main kinetic (mean vertical, horizontal, and resultant forces) and kinematic (contact time and step frequency) variables as well as surface electromyogram of quadriceps and plantar flexor muscles were fully recovered, with no significant difference between conditions. Despite differing hypoxic severity levels during sprints 1-8, performance and neuro-mechanical patterns did not differ during the four sprints of the second set performed in normoxia. In summary, under the circumstances of this study (participant background, exercise-to-rest ratio, hypoxia exposure), sprint mechanical performance and neural alterations were largely influenced by the hypoxia severity in an initial set of repeated sprints. However, hypoxia had no residual effect during a subsequent set performed in normoxia. Hence, the recovery of performance and associated neuro-mechanical alterations was complete after resting for 6 min near sea level, with a similar fatigue pattern across conditions during subsequent repeated sprints in normoxia.
Resumo:
STUDY DESIGN: Clinical measurement. PURPOSE: The test-retest reliability of maximal grip strength measurements (MGSM) is examined in subjects for 12 weeks post-stroke together with maximal grip strength recovery and the maximal-grip and upper-extremity strength measurements' relationship with capacity and performance test scores. METHODS: A Jamar dynamometer and the Motricity Index (MI) were used for strength measurements. The Chedoke Arm and Hand Activity Inventory and ABILHAND questionnaire for evaluating capacities and performances. RESULTS: MGSM were reliable (Intraclass Correlation Coefficients = 0.97-0.99, Minimal Detectable Differences = 2.73-4.68 kg). Among the 34 participants, 47% did not have a measurable grip strength one week post-stroke but 50% of these recovered some strength within the first eight weeks. The MGSM and MI scores were correlated with scores of tests of capacity and performance (Spearman's Rank Correlation Coefficients = 0.69-0.94). CONCLUSIONS: MGSM are reliable in the first weeks after a stroke. LEVEL OF EVIDENCE: N/A.
Resumo:
The present study proposes a method based on ski fixed inertial sensors to automatically compute spatio-temporal parameters (phase durations, cycle speed and cycle length) for the diagonal stride in classical cross-country skiing. The proposed system was validated against a marker-based motion capture system during indoor treadmill skiing. Skiing movement of 10 junior to world-cup athletes was measured for four different conditions. The accuracy (i.e. median error) and precision (i.e. interquartile range of error) of the system was below 6ms for cycle duration and ski thrust duration and below 35ms for pole push duration. Cycle speed precision (accuracy) was below 0.1m/s (0.005m/s) and cycle length precision (accuracy) was below 0.15m (0.005m). The system was sensitive to changes of conditions and was accurate enough to detect significant differences reported in previous studies. Since capture volume is not limited and setup is simple, the system would be well suited for outdoor measurements on snow.
Resumo:
PURPOSE: A surgical gastrostomy is mandatory in cases where a PEG is not feasible. Various minimally invasive techniques have been described, but many involve unusable materials in small children and/or have risk of disunion. We describe a technique for true Stamm gastrostomy performed by laparoscopy (LSG) with a purse string suture and four points of attachment onto the wall. METHOD: We reviewed 20 children who underwent an LSG from 2010 to 2013. After incision of the skin at the location planned for the gastrostomy, using three 3-5mm ports the stomach is fixed to the wall by three suspension stitches, which are entered and then emerged subcutaneously. A fourth stitch of attachment is used to make an award on the stomach and tie around the gastrostomy tube. RESULTS: Mean age was 4.2years, with 70% aged <2years. All children were malnourished, most often severely. All but two underwent a concomitant fundoplication. Feeding through the gastrostomy started on D0 or D1. Total feeding by gastrostomy was achieved in a mean duration of 2.9day. Mean hospital stay was 4.5days. There was no perioperative complication. Mean follow-up was 14months. Once, the balloon was accidently deflated and reinflated in the wall leading to its necrosis. Five peristomial granulomas were noticed. It was always possible to replace the tube by a gastrostomy device at least 6weeks after surgery. CONCLUSION: This new technique for true Stamm gastrostomy by laparoscopy reproduces exactly the one done by laparotomy, without special equipment. It can be made since the neonatal period, in all the circumstances when a laparoscopy is possible.
Annuaire de la papeterie française et étrangère (technique, industriel et commercial, fondé en 1865)
Resumo:
Variante(s) de titre : Annuaire général de la papeterie française et étrangère
Annuaire de la papeterie française et étrangère (technique, industriel et commercial, fondé en 1865)
Resumo:
1865 (A1).
Resumo:
Objectives: We present the retrospective analysis of a single-institution experience for radiosurgery (RS) in brain metastasis (BM) with Gamma Knife (GK) and Linac. Methods: From July 2010 to July 2012, 28 patients (with 83 lesions) had RS with GK and 35 patients (with 47 lesions) with Linac. The primary outcome was the local progression-free survival (LPFS). The secondary outcome was the overall survival (OS). Apart a standard statistical analysis, we included a Cox regression model with shared frailty, to modulate the within-patient correlation (preliminary evaluation showed a significant frailty effect, meaning that the correlation within patient could be ignored). Results: The mean follow-up period was 11.7 months (median 7.9, 1.7-22.7) for GK and 18.1 (median 17, 7.5-28.7) for Linac. The median number of lesions per patient was 2.5 (1-9) in GK compared with 1 (1-3) in Linac. There were more radioresistant lesions (melanoma) and more lesions located in functional areas for the GK group. The median dose was 24 Gy (GK) compared with 20 Gy (Linac). The LPFS actuarial rate was as follows: for GK at 3, 6, 9, 12, and 17 months: 96.96, 96.96, 96.96, 88.1, and 81.5%, and remained stable till 32 months; for Linac at 3, 6, 12, 17, 24, and 33 months, it was 91.5, 91.5, 91.5, 79.9, 55.5, and 17.1%, respectively (p = 0.03, chi-square test). After the Cox regression analysis with shared frailty, the p-value was not statistically significant between groups. The median overall survival was 9.7 months for GK and 23.6 months for Linac group. Uni- and multivariate analysis showed a lower GPA score and noncontrolled systemic status were associated with lower OS. Cox regression analysis adjusting for these two parameters showed comparable OS rate. Conclusions: In this comparative report between GK and Linac, preliminary analysis showed that more difficult cases are treated by GK, with patients harboring more lesions, radioresistant tumors, and highly functional located. The groups look, in this sense, very heterogeneous at baseline. After a Cox frailty model, the LPFS rates seemed very similar (p < 0.05). The OS was similar, after adjusting for systemic status and GPA score (p < 0.05). The technical reasons for choosing GK instead of Linac were the anatomical location related to highly functional areas, histology, technical limitations of Linac movements, especially lower posterior fossa locations, or closeness of multiple lesions to highly functional areas optimal dosimetry with Linac
Resumo:
This thesis studies the possibilities to recover energy in a hydraulic forklift system. Controlling of the system is done directly with an electric servo motor drive and a hydraulic pump. A real system was built and tested and simulations of the system were made with Matlab. Results of the system and simulations were analysed and compared and according to them, energy can be recovered efficiently from the hydraulic forklift system. Also new ideas and directions of further research were obtained with the help of this research.
Resumo:
A method for generating beams with arbitrary polarization and shape is proposed. Our design requires the use of a Mach-Zehnder set-up combined with translucent liquid crystal displays in each arm of the interferometer; in this way, independent manipulation of each transverse beam components is possible. The target of this communication is to develop a numerical procedure for calculating the holograms required for dynamically encode any amplitude value and polarization state in each point of the wavefront. Several examples demonstrating the capabilities of the method are provided.
Resumo:
We use an ordered logistic model to empirically examine the factors that explain varying degrees of private involvement in the U.S. water sector through public-private partnerships. Our estimates suggest that a variety of factors help explain greater private participation in this sector. We find that the risk to private participants regarding cost recovery is an important driver of private participation. The relative cost of labor is also a key factor in determining the degree of private involvement in the contract choice. When public wages are high relative to private wages, private participation is viewed as a source of cost savings. We thus find two main drivers of greater private involvement: one encouraging private participation by reducing risk, and another encouraging government to seek out private participation in lowering costs.