959 resultados para RADIOGRAPHIC OSTEOARTHRITIS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 38 year old woman having chronic intestinal pseudoobstruction associated with mitochondrial myopathy is reported. The clinical and radiographic features suggested the diagnosis of chronic intestinal pseudoobstruction. Muscular atrophy and ophthalmoplegia led to muscle biopsy, which disclosed accumulation of normal and abnormal mitochondria ('ragged red fibres'), characteristic of mitochondrial myopathy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the results of an anatomic open stabilization procedure. Twenty-three consecutive patients with traumatic, recurrent, anterior glenohumeral instability were managed with a modified open procedure. All had a Bankart lesion. A standardized, true anatomic capsulolabral reconstruction was performed with suture anchors. Two patients were lost to follow-up, and twenty-one were evaluated after 36 months [range, 24-49 months] by an independent observer. Shoulder stability and function were the principal outcome measures. None of the patients had subsequent dislocations. All returned to full working capacity, and 19 reached their previous level of sport activities. The mean loss in active abduction and flexion was 1 degrees, in internal rotation, one vertebral level, and in external rotation, 7 degrees (arm at 90 degrees of abduction). Two patients had a positive anterior apprehension test. No sign of shoulder osteoarthritis was observed. The open anatomic capsulolabral reconstruction provides excellent results and allows the restoration of stability with good function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of this work is to develop a method to objectively compare the performance of a digital and a screen-film mammography system in terms of image quality. The method takes into account the dynamic range of the image detector, the detection of high and low contrast structures, the visualisation of the images and the observer response. A test object, designed to represent a compressed breast, was constructed from various tissue equivalent materials ranging from purely adipose to purely glandular composition. Different areas within the test object permitted the evaluation of low and high contrast detection, spatial resolution and image noise. All the images (digital and conventional) were captured using a CCD camera to include the visualisation process in the image quality assessment. A mathematical model observer (non-prewhitening matched filter), that calculates the detectability of high and low contrast structures using spatial resolution, noise and contrast, was used to compare the two technologies. Our results show that for a given patient dose, the detection of high and low contrast structures is significantly better for the digital system than for the conventional screen-film system studied. The method of using a test object with a large tissue composition range combined with a camera to compare conventional and digital imaging modalities can be applied to other radiological imaging techniques. In particular it could be used to optimise the process of radiographic reading of soft copy images.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Atraumatic osteonecrosis of the talus can be extremely painful and lead to significant functional impairment. Although clinical, radiographic, and demographic characteristics of atraumatic osteonecrosis of the talus have been well documented, the diagnosis is frequently missed or delayed; the most common causes are use of corticosteroids and the presence of immune disorders. Operative treatment of large osteochondral lesions of the talus is difficult because the blood supply is poor in the talar dome. Microvascular reconstruction of the talar dome with iliac crest autografts is a complex but functionally excellent therapeutic option. We present a 48-year-old man, who developed an extensive atraumatic avascular necrosis of the talar dome without collapse. Except for insulin dependent diabetes mellitus no further comorbidities were known. A microvascular iliac crest bone flap was inserted into the talus. A follow-up 16 years postoperatively showed a clinically as well as radiographically stable reconstruction of the talar dome and an excellent mobility of the ankle joint. The AOFAS hindfoot scale had improved from initially 33 points to 100 on the last follow-up. Free microvascular bony reconstruction of the talar dome should not only be considered in younger patients but also for middle aged active patients, since our follow-up shows an excellent long term result. Early reconstruction can prevent collapse of the talar bone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ethmoidal regions weer prepared and dissected to demonstrate regional sinus anatomy and endoscopic surgery approaches from six human heads. After perparation, the specimens were plastinated using the standard S10 technique. A CT-scan of each ethmoidal block was performed before and after preparation of the block to access shrinkage. The plastinated specimens were successfully introduced into clinical teaching of sinus anatomy and surgery. One advantage of using these specimens is their long-lasting preservation without deterioration of the tissue. The specimens were well suited for comparative radiographic and ondoscopic studies, and the CT-scans allowed an exact measurement of tissue shrinkage due to plastination. Increaseed tissue rigidity and shrionkage due to plastination has to be taken into account for subsequent endoscopic observation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Usually the measurement of multi-segment foot and ankle complex kinematics is done with stationary motion capture devices which are limited to use in a gait laboratory. This study aimed to propose and validate a wearable system to measure the foot and ankle complex joint angles during gait in daily conditions, and then to investigate its suitability for clinical evaluations. The foot and ankle complex consisted of four segments (shank, hindfoot, forefoot, and toes), with an inertial measurement unit (3D gyroscopes and 3D accelerometers) attached to each segment. The angles between the four segments were calculated in the sagittal, coronal, and transverse planes using a new algorithm combining strap-down integration and detection of low-acceleration instants. To validate the joint angles measured by the wearable system, three subjects walked on a treadmill for five minutes at three different speeds. A camera-based stationary system that used a cluster of markers on each segment was used as a reference. To test the suitability of the system for clinical evaluation, the joint angle ranges were compared between a group of 10 healthy subjects and a group of 12 patients with ankle osteoarthritis, during two 50-m walking trials where the wearable system was attached to each subject. On average, over all joints and walking speeds, the RMS differences and correlation coefficients between the angular curves obtained using the wearable system and the stationary system were 1 deg and 0.93, respectively. Moreover, this system was able to detect significant alteration of foot and ankle function between the group of patients with ankle osteoarthritis and the group of healthy subjects. In conclusion, this wearable system was accurate and suitable for clinical evaluation when used to measure the multi-segment foot and ankle complex kinematics during long-distance walks in daily life conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Cervical foraminal injection performed with a direct foraminal approach may induce serious neurologic complications. We describe a technique of CT-guided cervical facet joint (CFJ) injection as an indirect foraminal injection, including feasibility and diffusion pathways of the contrast agent. Methods and materials: Retrospective study included 84 punctures in 65 consecutive patients presenting neck pain and/or radiculopathy related to osteoarthritis or soft disc herniation. CT images were obtained from C2 to T1 in supine position, with a metallic landmark on the skin. CFJ punctures were performed by MSK senior radiologists with a lateral approach. CT control of the CFJ opacification was performed after injections of contrast agent (1 ml), followed by slow-acting corticosteroid (25 mg). CFJ opacification was considered as successful when joint space and/or capsular recess opacification occurred. The diffusion of contrast agent in foraminal and epidural spaces was recorded. We assessed the epidural diffusion both on axial and sagittal images, with a classification in two groups (small diffusion or large diffusion). Results: CFJ opacification was successful in 82% (69/84). An epidural and/or foraminal opacification was obtained in 74% (51/69). A foraminal opacification occurred in 92% (47/51) and an epidural opacification in 63% (32/51), with small diffusion in 47% (15/32) and large diffusion in 53% (17/32). No complication occurred. Conclusion: CT- guided CFJ injection is easy to perform and safe. It is most often successful, with a frequent epidural and/or foraminal diffusion of the contrast agent. This technique could be an interesting and safe alternative to foraminal cervical injection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In mammography, the image contrast and dose delivered to the patient are determined by the x-ray spectrum and the scatter to primary ratio S/P. Thus the quality of the mammographic procedure is highly dependent on the choice of anode and filter material and on the method used to reduce the amount of scattered radiation reaching the detector. Synchrotron radiation is a useful tool to study the effect of beam energy on the optimization of the mammographic process because it delivers a high flux of monochromatic photons. Moreover, because the beam is naturally flat collimated in one direction, a slot can be used instead of a grid for scatter reduction. We have measured the ratio S/P and the transmission factors for grids and slots for monoenergetic synchrotron radiation. In this way the effect of beam energy and scatter rejection method were separated, and their respective importance for image quality and dose analyzed. Our results show that conventional mammographic spectra are not far from optimum and that the use of a slot instead of a grid has an important effect on the optimization of the mammographic process. We propose a simple numerical model to quantify this effect.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Las metatarsalgias o dolor localizado en el antepié, representan uno de los cuadros clínicos más frecuentement observados en nuestras consultas de podología. En un 90% de los casos son de origen mecánico, a consecuencia de alteraciones biomecánicas de esta zona, que acaban la mayoría de las veces en procesos degenerativos artrósicos, de difícil tratamiento.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Disease characteristics. Recessive multiple epiphyseal dysplasia (EDM4/rMED) is characterized by joint pain (usually in the hips or knees); malformations of hands, feet, and knees; and scoliosis. Approximately 50% of affected individuals have some abnormal finding at birth, e.g., clubfoot, clinodactyly, or (rarely) cystic ear swelling. Onset of articular pain is variable but usually occurs in late childhood. Stature is usually within the normal range prior to puberty; in adulthood, stature is only slightly diminished and ranges from 150 to 180 cm. Functional disability is mild. Diagnosis/testing. Diagnosis of EDM4/rMED is based on clinical and radiographic findings. SLC26A2 is the only gene known to be associated with EDM4/rMED. Molecular genetic testing is available on a clinical basis. Management. Treatment of manifestations: physiotherapy for muscular strengthening; cautious use of analgesic medications such as nonsteroidal anti-inflammatory drugs (NSAIDs); orthopedic surgery as indicated. Surveillance: radiographs as indicated. Agents/circumstances to avoid: sports involving joint overload. Genetic counseling. EDM4/rMED is inherited in an autosomal recessive manner. At conception, each sib of a proband with EDM4/rMED has a 25% chance of being affected, a 50% chance of being an asymptomatic carrier, and a 25% chance of being unaffected and not a carrier. Once an at-risk sib is known to be unaffected, the risk of his/her being a carrier is 2/3. Carrier testing for at-risk relatives and prenatal testing for pregnancies at increased risk is possible if both disease-causing alleles in the family are known and the carrier status of the parents has been confirmed. Requests for prenatal testing for mild conditions such as EDM4/rMED are not common.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Video records are widely used to analyze performance in alpine skiing at professional or amateur level. Parts of these analyses require the labeling of some movements (i.e. determining when specific events occur). If differences among coaches and differences for the same coach between different dates are expected, they have never been quantified. Moreover, knowing these differences is essential to determine which parameters reliable should be used. This study aimed to quantify the precision and the repeatability for alpine skiing coaches of various levels, as it is done in other fields (Koo et al, 2005). METHODS: A software similar to commercialized products was designed to allow video analyses. 15 coaches divided into 3 groups (5 amateur coaches (G1), 5 professional instructors (G2) and 5 semi-professional coaches (G3)) were enrolled. They were asked to label 15 timing parameters (TP) according to the Swiss ski manual (Terribilini et al, 2001) for each curve. TP included phases (initiation, steering I-II), body and ski movements (e.g. rotation, weighting, extension, balance). Three video sequences sampled at 25 Hz were used and one curve per video was labeled. The first video was used to familiarize the analyzer to the software. The two other videos, corresponding to slalom and giant slalom, were considered for the analysis. G1 realized twice the analysis (A1 and A2) at different dates and TP were randomized between both analyses. Reference TP were considered as the median of G2 and G3 at A1. The precision was defined as the RMS difference between individual TP and reference TP, whereas the repeatability was calculated as the RMS difference between individual TP at A1 and at A2. RESULTS AND DISCUSSION: For G1, G2 and G3, a precision of +/-5.6 frames, +/-3.0 and +/-2.0 frames, was respectively obtained. These results showed that G2 was more precise than G1, and G3 more precise than G2, were in accordance with group levels. The repeatability for G1 was +/-3.1 frames. Furthermore, differences among TP precision were observed, considering G2 and G3, with largest differences of +/-5.9 frames for "body counter rotation movement in steering phase II", and of 0.8 frame for "ski unweighting in initiation phase". CONCLUSION: This study quantified coach ability to label video in term of precision and repeatability. The best precision was obtained for G3 and was of +/-0.08s, which corresponds to +/-6.5% of the curve cycle. Regarding the repeatability, we obtained a result of +/-0.12s for G1, corresponding to +/-12% of the curve cycle. The repeatability of G2 and G3 are expected to be lower than the precision of G1 and the corresponding repeatability will be assessed soon. In conclusion, our results indicate that the labeling of video records is reliable for some TP, whereas caution is required for others. REFERENCES Koo S, Gold MD, Andriacchi TP. (2005). Osteoarthritis, 13, 782-789. Terribilini M, et al. (2001). Swiss Ski manual, 29-46. IASS, Lucerne.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To describe the clinical features of idiopathic chiasmal neuritis in a large cohort of patients and to report their visual and neurologic outcomes. DESIGN: A retrospective medical record review of consecutive patients with chiasmal neuritis at a single institution. Patients with clinical or radiographic evidence of inflammation involving the intraorbital optic nerve and patients with a systemic inflammatory or neoplastic disorder were excluded. RESULTS: Twenty patients were identified (14 female, 6 male; mean age, 37 years). Visual acuity at initial examination ranged from 20/15 to light perception. Progressive visual loss beyond 1 month was documented in 1 patient. Twelve of 15 patients who underwent magnetic resonance imaging demonstrated chiasmal enlargement and/or enhancement; 6 patients had 1 or more white matter lesions. Follow-up time ranged from 2 weeks to 22 years, with a mean of 5.7 years. The final median visual acuity was 20/20 (range, 20/15-20/50) and visual fields were normal or improved. Of 15 patients with a minimum follow-up interval of 1 year, 6 developed multiple sclerosis. CONCLUSIONS: The demographic and clinical features of idiopathic chiasmal neuritis resemble those of idiopathic optic neuritis. Visual prognosis is excellent. In this series, 40% of patients subsequently developed multiple sclerosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: A new ultra congruent, postero-stabilized total knee arthroplasty (TKA) with a mobile bearing, the FIRST knee prosthesis (Free Insert in Rotation Stabilized in Translation, Symbios SA), was designed and expected to significantly reduce polyethylene wear, to improve the range of motion and the overall stability of the knee while ensuring a physiological ligament balance. Gait analysis has proven to give really objective outcome parameters after lower limb surgery. The goal of our study was to compare the subjective and really objective results of this new TKA with two other widespread models of TKA. Methods: A clinical prospective monocentric cohort study of 100 consecutive patients (47-88 yrs) undergoing a FIRST TKA for primary osteoarthritis is currently being done. Pre- and post-operative follow-ups (6 weeks, 4 months and 1 year) were done with well-recognized subjective evaluations (EQ-5D and WOMAC scores) and semi-objective questionnaires (KSS score and radiography evaluation) as well as with a really objective evaluation using gait parameters from 6 walking trials, performed at different speeds (slow, normal and fast) with an ambulatory gait analysis system (Physilog®, BioAGM CH). The outcomes of the first 32 new TKA after one year of follow-up were compared to the results after 1 year of a randomized controlled clinical trial comparing 29 NexGen® postero-stabilized TKA (Zimmer Inc) with a fixed bearing and 26 NexGen® TKA with a mobile bearing using the same methods. Results: Subjective and semi-objective results were similar for the three types of TKA. As for the really objective parameters, the gait cycle time of the FIRST TKA was statistically significantly shorter at normal speed of walk, as well as double-support periods, as compared to both standard models. The extension (in terms of range of motion when walking) of the operated knee was significantly improved for all three types of walk in favour of the FIRST TKAs compared to both NexGen TKAs. The normal walking speed was significantly higher with faster swing speed and stride lengths for the new TKA. Significantly better coordination scores were observed at normal walking speed for the FIRST TKA as compared to the fixed-bearing TKAs. Conclusion: The FIRST TKAs showed statistically significantly better objective outcomes in terms of gait after one year of follow-up with similar subjective and semi-objective results in comparison with widespread TKA designs. These encouraging short-terms results will have to be confirmed at a 5 years follow-up of the FIRST TKAs.