990 resultados para Quantitative sensory test
Resumo:
Lesions observed in chronic chagasic cardiopathy frequently produce electrocardiographic alterations and affect cardiac function. Through a computerized morphometrical analysis we quantified the areas occupied by cardiac muscle, connective and adipose tissues in the right atrium of dogs experimentally infected with Trypanosoma cruzi. All of the infected dogs showed chronic myocarditis with variable reduction levels of cardiac muscle, fibrosis and adipose tissue replacement. In the atrial myocardium of dogs infected with Be78 and Be62 cardiac muscle represented 34 and 50%, fibrosis 28 and 32% and adipose tissue 38 and 18%, respectively. The fibrosis observed was both diffuse and focal and mostly intrafascicular, either partially or completely interrupting the path of muscle bundles. Such histological alterations probably contributed to the appearance of electrocardiographic disturbances verified in 10 out 11 dogs which are also common in human chronic chagasic cardiopathy. Fibrosis was the most important microscopic occurrence found since it produces rearrangements of collagen fibers in relation to myocardiocytes which causes changes in anatomical physiognomy and mechanical behavior of the myocardium. These abnormalities can contribute to the appearance of cardiac malfunction, arrythmias and congestive cardiac insufficiency as observed in two of the analyzed dogs. Strain Be78 caused destruction of atrial cardiac muscle higher than that induced by strain Be62.
Resumo:
The present study was carried out to evaluate the Malar-CheckTM Pf test, an immunochromatographic assay that detects Plasmodium falciparum Histidine Rich Protein II, does not require equipment, and is easy and rapid to perform. In dilution assays performed to test sensitivity against known parasite density, Malar-CheckTMwere compared with thick blood smear (TBS), the gold standard for diagnosis. Palo Alto isolate or P. falciparum blood from patients with different parasitemias was used. The average cut-off points for each technique in three independent experiments were 12 and 71 parasites/mm³ (TBS and Malar-CheckTM, respectively). In the field assays, samples were collected from patients with fever who visited endemic regions. Compared to TBS, Malar-CheckTMyielded true-positive results in 38 patients, false-positive results in 3, true-negative results in 23, and false-negative result in 1. Malar-CheckTMperformed with samples from falciparum-infected patients after treatment showed persistence of antigen up to 30 days. Malar-CheckTM should aid the diagnosis of P. falciparum in remote areas and improve routine diagnosis even when microscopy is available. Previous P. falciparum infection, which can determine a false-positive test in cured individuals, should be considered. The prompt results obtained with the Malar-CheckTM for early diagnosis could avoid disease evolution to severe cases.
Resumo:
This study evaluated the whole blood immunochromatographic card test (ICT card test) in a survey performed in Northeastern Brazil. 625 people were examined by the thick blood film (TBF) and ICT card test. Residents of a non-endemic area were also tested by the whole blood card test and Og4C3. The sensitivity of the ICT card test was 94.7% overall, but lower in females than males, based on the reasonable assumption that TBF is 100% specific. However, since TBF and other methods have unknown sensitivity, the true specificity of the card test is unknown. Nevertheless, it is possible to estimate upper and lower limits for the specificity, and relate it to the prevalence of the disease. In the endemic area, the possible range of the specificity was from 72.4% to 100%. 29.6% of the card tests performed in the non-endemic area exhibited faint lines that were interpreted as positives. Characteristics of the method including high sensitivity, promptness and simplicity justify its use for screening of filariasis. However, detailed information about the correct interpretation in case of extremely faint lines is essential. Further studies designed to consider problems arising from imperfect standards are necessary, as is a sounder diagnostic definition for the card test.
Resumo:
Using low cost portable devices that enable a single analytical step for screening environmental contaminants is today a demanding issue. This concept is here tried out by recycling screen-printed electrodes that were to be disposed of and by choosing as sensory element a low cost material offering specific response for an environmental contaminant. Microcystins (MCs) were used as target analyte, for being dangerous toxins produced by cyanobacteria released into water bodies. The sensory element was a plastic antibody designed by surface imprinting with carefully selected monomers to ensure a specific response. These were designed on the wall of carbon nanotubes, taking advantage of their exceptional electrical properties. The stereochemical ability of the sensory material to detect MCs was checked by preparing blank materials where the imprinting stage was made without the template molecule. The novel sensory material for MCs was introduced in a polymeric matrix and evaluated against potentiometric measurements. Nernstian response was observed from 7.24 × 10−10 to 1.28 × 10−9 M in buffer solution (10 mM HEPES, 150 mM NaCl, pH 6.6), with average slopes of −62 mVdecade−1 and detection capabilities below 1 nM. The blank materials were unable to provide a linear response against log(concentration), showing only a slight potential change towards more positive potentials with increasing concentrations (while that ofthe plastic antibodies moved to more negative values), with a maximum rate of +33 mVdecade−1. The sensors presented good selectivity towards sulphate, iron and ammonium ions, and also chloroform and tetrachloroethylene (TCE) and fast response (<20 s). This concept was successfully tested on the analysis of spiked environmental water samples. The sensors were further applied onto recycled chips, comprehending one site for the reference electrode and two sites for different selective membranes, in a biparametric approach for “in situ” analysis.
Resumo:
A promoção de competências de leitura é um tema central, tanto na educação regular, como na educação especial em crianças em idade pré-escolar e escolar. Todavia, as competências de leitura de indivíduos adultos com incapacidade intelectual são um domínio muito pouco estudado. São também escassos os estudos direcionados à avaliação dessas competências. Esta investigação propõe uma tradução/ adaptação do APAR (Assessment of Phonological Awareness and Reading), um protocolo de avaliação da consciência fonológica (CF) e da leitura especificamente concebido para a população em estudo. Procura-se também analisar os processos cognitivos envolvidos na leitura nos quais a intervenção produzirá resultados mais significativos e confirmar uma relação positiva entre a avaliação prévia de competências escolares em contexto formativo profissional e o efetivo desenvolvimento de competências de leitura. Foram avaliadas em dois momentos (pré e pós-teste) a CF e competências de leitura de 12 adultos com incapacidade intelectual ligeira, sendo estes sujeitos a um programa de intervenção, visando áreas menos desenvolvidas das suas competências que possibilitassem desempenhos de leitura mais fortes. Ao nível da análise quantitativa, foram comparados os resultados obtidos nos dois momentos de administração. No tratamento estatístico recorreu-se a análises de correlação de Spearman para determinar a presença de indicadores de desempenho ao nível da CF e ao cálculo de coeficientes de correlação de Pearson e Spearman para controlar variáveis externas como idade, sexo e habilitações literárias. Os resultados obtidos revelam desempenhos fracos ao nível da leitura/ compreensão textual e, em particular, da CF em pré-teste e ganhos significativos globais após implementação de uma intervenção baseada em medidas de avaliação prévia de competências de leitura/compreensão e CF
Resumo:
A novel optical disposable probe for screening fluoroquinolones in fish farming waters is presented, having Norfloxacin (NFX) as target compound. The colorimetric reaction takes place in the solid/liquid interface consisting of a plasticized PVC layer carrying the colorimetric reagent and the sample solution. NFX solutions dropped on top of this solid-sensory surface provided a colour change from light yellow to dark orange. Several metals were tested as colorimetric reagents and Fe(III) was selected. The main parameters affecting the obtained colour were assessed and optimised in both liquid and solid phases. The corresponding studies were conducted by visible spectrophotometry and digital image acquisition. The three coordinates of the HSL model system of the collected image (Hue, Saturation and Lightness) were obtained by simple image management (enabled in any computer). The analytical response of the optimised solid-state optical probe against concentration was tested for several mathematical transformations of the colour coordinates. Linear behaviour was observed for logarithm NFX concentration against Hue+Lightness. Under this condition, the sensor exhibited a limit of detection below 50 μM (corresponding to about 16 mg/mL). Visual inspection also enabled semi-quantitative information. The selectivity was ensured against drugs from other chemical groups than fluoroquinolones. Finally, similar procedure was used to prepare an array of sensors for NFX, consisting on different metal species. Cu(II), Mn(II) and aluminon were selected for this purpose. The sensor array was used to detect NFX in aquaculture water, without any prior sample manipulation.
Resumo:
A rapid test based on an immunochromatography assay - Determine Syphilis TP (Abbott Lab.) for detecting specific antibodies to Treponema pallidum was evaluated against serum samples from patients with clinical, epidemiological and serological diagnosis of syphilis, patients with sexually transmitted disease other than syphilis, and individuals with negative serology for syphilis. The Determine test presented the sensitivity of 93.6%, specificity of 92.5%, and positive predictive value and negative predictive value of 95.2% and 93.7%, respectively. One serum sample from patient with recent latent syphilis showed a prozone reaction. Determine is a rapid assay, highly specific and easy to perform. This technique obviates the need of equipment and its diagnostic features demonstrate that it may be applicable as an alternative assay for syphilis screening under some emergency conditions or for patients living in remote localities.
Resumo:
A novel artificial antibody for troponin T (TnT) was synthesized by molecular imprint (MI) on the surface of multiwalled carbon nanotubes (MWCNT). This was done by attaching TnT to the MWCNT surface, and filling the vacant spaces by polymerizing under mild conditions acrylamide (monomer) in N,N′-methylenebisacrylamide (cross-linker) and ammonium persulphate (initiator). After removing the template, the obtained biomaterial was able to rebind TnT and discriminate it among other interfering species. Stereochemical recognition of TnT was confirmed by the non-rebinding ability displayed by non-imprinted (NI) materials, obtained by imprinting without a template. SEM and FTIR analysis confirmed the surface modification of the MWCNT. The ability of this biomaterial to rebind TnT was confirmed by including it as electroactive compound in a PVC/plasticizer mixture coating a wire of silver, gold or titanium. Anionic slopes of 50 mV decade−1 were obtained for the gold wire coated with MI-based membranes dipped in HEPES buffer of pH 7. The limit of detection was 0.16 μg mL−1. Neither the NI-MWCNT nor the MWCNT showed the ability to recognize the template. Good selectivity was observed against creatinine, sucrose, fructose, myoglobin, sodium glutamate, thiamine and urea. The sensor was tested successfully on serum samples. It is expected that this work opens new horizons on the design of new artificial antibodies for complex protein structures.
Resumo:
RESUMO - O presente projecto enquadra-se no paradigma salutogénico e visa apurar alguns dos factores que determinam que algumas pessoas se apresentem mais saudáveis que a população em geral. Foi seleccionado um estudo, quantitativo, analítico tipo caso-controlo (1 caso para 3 controlos), em que os casos são constituídos por indivíduos integrando a Função Pública que se encontram acima do percentil 95 de assiduidade ao trabalho nos últimos dois anos e com uma auto-percepção de Saúde classificada como muito boa, os controlos são indivíduos que não obedecem à definição de caso. Os indivíduos serão emparelhados por idade, género, estado civil, carreira, categoria profissional e unidade funcional que integram. A assiduidade será calculada com recurso aos certificados de incapacidade temporária entregues nos respectivos serviços. Os factores a estudar são os mais citados na literatura como factores salutogénicos ou factores de protecção, são eles: - Sentido de Coerência de Antonowsky - Locus de controlo - Auto conceito -Auto Eficácia - Aptidão física nas três vertentes clássicas: Capacidade aeróbia, Composição corporal, Aptidão muscular. Todos estes factores serão estudados com recurso a questionários auto preenchidos devidamente testados e validados para o português de Portugal sendo a aptidão física apurada com recurso á bateria de testes "Fitness Gram" adoptada para Portugal pelo Instituto do Desporto de Portugal e pelo Ministério da Educação. Os resultados serão apurados com recurso ao software de análise epidemiológica EPIDAT. 3.1. ---------------- ABSTRACT - The present project follows the salutogénic paradigm and intends to identify some of the factors that determine why some people are healthier than the general population. It was selected a quantitative, analytic, case-control study type (1 case to 3 controls), in which the cases are constituted by individuals who are integrated in Public Services and find themselves above 95 percentile of assiduity in work in the last two years, and with a self-perception of Health classified as very good, the controls are individuals who don’t obey to the case definition. The individuals will be matched by age, gender, civil state, career, professional category and Functional Unity in the Health services. The assiduity will be calculated with the help of temporary incapacity certificates delivered in the respective services. The currently studying factors are the most cited in literature, like salutogenic factors or protection factors, are those: - Antonowsky’s Sense of Coherence - Locus Control - Self-concept - Self-Efficacy - The three classic strands of Physical Fitness: Aerobic Capacity, Corporal Composition, Muscular Fitness. All these factors will be studied with the resource of properly tested and validated self-filled questionnaires for Portugal Portuguese (language), with the Physical Fitness being determined with the resource of “Fitness Gram” test battery, adopted for Portugal by the Portuguese Sports Institute and the Education Ministry. The results will be determined with the resource of the epidemiologic analysis software EPIDAT. 3.1.
Resumo:
NanoPT 2014 International Conference, in Portugal, on February 12-14. Poster presentation based on topic Nanobio/Nanomedicine
Resumo:
Twenty-four whole blood and serum samples were drawn from an eight year-old heart transplant child during a 36 months follow-up. EBV serology was positive for VCA-IgM and IgG, and negative for EBNA-IgG at the age of five years old when the child presented with signs and symptoms suggestive of acute infectious mononucleosis. After 14 months, serological parameters were: positive VCA-IgG, EBNA-IgG and negative VCA-IgM. This serological pattern has been maintained since then even during episodes suggestive of EBV reactivation. PCR amplified a specific DNA fragment from the EBV gp220 (detection limit of 100 viral copies). All twenty-four whole blood samples yielded positive results by PCR, while 12 out of 24 serum samples were positive. We aimed at analyzing whether detection of EBV-DNA in serum samples by PCR was associated with overt disease as stated by the need of antiviral treatment and hospitalization. Statistical analysis showed agreement between the two parameters evidenced by the Kappa test (value 0.750; p < 0.001). We concluded that detection of EBV-DNA in serum samples of immunosuppressed patients might be used as a laboratory marker of active EBV disease when a Real-Time PCR or another quantitative method is not available.
Resumo:
O objetivo desta investigação é compreender até que ponto a experiência passada do empreendedor social condicionou a decisão de lançamento de uma iniciativa social. A investigação adota uma metodologia quantitativa, o que implicou o recurso à construção de um questionário que foi aplicado, sob a forma de inquérito online, às Organizações Não Governamentais para o Desenvolvimento registadas em Portugal e aos projetos cotados na Bolsa de Valores Sociais. Para o tratamento e a análise dos dados foram aplicadas técnicas de análise descritiva e técnicas de estatística inferencial (teste binomial e teste do qui-quadrado do ajustamento). Os resultados deste estudo confirmam o papel relevante que as experiências profissionais e pessoais passadas têm sobre a adoção de um comportamento socialmente empreendedor