993 resultados para Pulp Revascularization
Resumo:
This project has two different goals, one of them is to promote the consumption of exotic fruits with high quality. The other goal of the project is to look for the viability of turning this work project into a real business, focusing in two different channels to diversify its revenues: B2B and B2C. In order to achieve this second goal, this project aims to see the best way to commercialize this product (Lucuma powder and Pulp of Lucuma) and how to make it in an efficient way with right companies. Therefore, the project aims to create a company to commercialize the product between the producers in Peru and possibly small businesses interested in acquire the processed fruit and also individuals interested in own consumption in small quantities. This project, if successful, tries to diversify the consumption into other good organic healthy products in the long-term.
Resumo:
Diabetic neuropathy is an important complication of the disease, responsible for ulceration and amputation of the foot. Prevention of these problems is difficult mainly because there is no method to correctly access sensibility on the skin of the foot. The introduction of the Pressure-Specified Sensory Device (PSSD TM) in the last decade made possible the measurement of pressure thresholds sensed by the patient, such as touch, both static and in movement, on a continuous scale. This paper is the first in Brazil to report the use of this device to measure cutaneous sensibility in 3 areas of the foot: the hallux pulp, the calcaneus, and the dorsum, which are territories of the tibial and fibular nerves. METHOD: Non-diabetic patients were measured as controls, and 2 groups of diabetic patients - with and without ulcers - were compared. The PSSD TM was used to test the 3 areas described above. The following were evaluated: 1 PS (1-point static), 1 PD (1-point dynamic), 2 PS (2-points static), 2 PD (2-points dynamic). RESULTS: The diabetic group had poorer sensibility compared to controls and diabetics with ulcers had poorer sensibility when compared to diabetics without ulcers. The differences were statistically significant (P <.001). CONCLUSION: Due to the small number of patients compared, the results should be taken as a preliminary report.
Resumo:
RESUMO: Na clínica, a recuperação funcional que se segue a uma lesão nervosa raramente é atingida na sua totalidade. A reinervação, quer motora, quer sensitiva, ocorre geralmente com maior ou menor deficit. Interessa, então, identificar os factores que podem interferir na regeneração nervosa. O neurónio é a unidade anatómica fundamental do sistema nervoso periférico e é muito vulnerável à isquemia pela grande distância que existe entre o corpo neuronal e a extensão do axónio, que pode ser de apenas alguns milímetros ou até atingir um metro. É, por isso, fundamental o estudo da vascularização do nervo periférico e da sua influência na regeneração nervosa. O resultado deste estudo pode levar ao desenvolvimento de técnicas cirúrgicas que criem as condições que garantam, por sua vez, a revascularização precoce do nervo periférico em caso de lesão, ou mesmo em caso de doenças, nas quais a vascularização do nervo está alterada como, por exemplo, na neuropatia diabética. O estudo da vascularização do nervo periférico realizou-se através da investigação da vascularização do nervo mediano do cadáver humano, pela investigação da vascularização do nervo isquiático do rato Wistar e do Plexo Braquial (PB) do mesmo. A vascularização do PB do rato não é muito diferente daquela que é reportada na espécie humana, existindo uma homologia entre o rato e o Homem no que diz respeito à morfologia e à vascularização do PB. Através da comparação angiomorfológica entre o nervo isquiático do rato e o nervo mediano humano, concluíu-se que a microvascularização do nervo isquiático do rato e do mediano humano são muito semelhantes, o que suporta a utilização do rato como modelo experimental de lesões do nervo mediano humano. Para a avaliação da influência da vascularização na regeneração nervosa foi feita a análise da eficácia de enxerto de tubo de membrana amniótica humana imunologicamente inerte, de enxerto de veia jugular externa autóloga e de auto-enxerto de nervo, na reparação de um defeito de 10 milímetros no nervo isquiático do rato, na presença de um fornecimento vascular axial, comparando-se com os mesmos procedimentos em estudos realizados anteriormente, sem suprimento vascular. Os ratos foram avaliados funcionalmente através do estudo das pegadas, da electroneurografia e da força de flexão ao nível do tornozelo, e estruturalmente, através das avaliações histológicas e morfométricas, da taxa de recuperação do peso dos músculos gastrocnémio e solhear e da marcação axonal retrógrada com True Blue às 4, 8 e 12 semanas. Os nervos reconstruídos apresentaram uma arquitectura normal, incluindo a arquitectura vascular. A membrana amniótica foi bem tolerada, persistindo imunologicamente em torno do nervo até à 12.ª semana. Concluiu-se também que, na presença de um suprimento vascular axial local, a membrana amniótica humana e as veias autólogas são, pelo menos, tão eficazes como os auto-enxertos nervosos na reconstrução de defeitos nervosos de 10 milímetros.--------------------------------------ABSTRACT: At the clinic, the functional recovery that follows a nerve lesion is rarely achieved in full. The neuron is very vulnerable to ischemia that’s why it is essential to study the vascularization of the peripheral nerve and its influence on the nerve’s regeneration. The outcome of this study may lead to the development of surgical techniques that create the conditions which are necessary to ensure an early revascularization in case of a peripheral nerve injury. This study investigated the vascularization of the median nerve of the human cadaver and the vascularization of the sciatic nerve of the Wistar rat and his Brachial Plexus (BP) through animal experimentation. The mouse's BP vascularization is not so different from the one that is reported in the human species. An angiomorphological comparison between the mouse sciatic nerve and the human median nerve concluded that the microvascularizations are very similar, which supports the use of the mouse as an experimental model for the study of median nerve’s lesions. To evaluate the influence of vascularization in the nerve’s regeneration, it was made an assessment of the effectiveness of the human amniotic immuno-inert membrane grafts, of the autologous external jugular vein grafts and of the nerve auto-graft in the repair of a defect of 10 mm on the sciatic nerve of the rat, in the presence of an axial vascular supply, comparing these with the same procedures that were adopted in the previous studies, without vascular supply. The rats were functionally assessed and structurally evaluated (through histological and morphometric evaluations) at the 4.th, 8.th and 12.th weeks. The nerves reconstructed presented a normal architecture, including vascular architecture. The amniotic membrane was well-tolerated immunologically, persisting around the nerve until the 12.th week. As a result, it was also concluded that in the presence of a local axial vascular supply, the human amniotic membrane and the autologous veins are, at least, as effective as the nerve auto-grafts in the reconstruction of the nerve’s defects of 10 mm.
Resumo:
Cupuassu (Theobroma grandiflorum), a specie native to Amazonia, has been planted commercially in Brazil to satisfy the demand for the flavorful juice obtained from the pulp around its seeds. The trees are notorious for low and irregular fruit production. Data gathered over two seasons from trees in a germplasm collection in Pará, Brazil, showed that some of them fruited more regularly than others. Differences in fruit production correlated to differences in flower production. Tree-to-tree variation in flower production, fruit production, and consistency of both over time suggest considerable scope for improving yields by selection. Hand pollinations resulted in a much higher frequency of fruit set than open pollinations, indicating that lack of effective pollination is also a reason for low yield. However, attempts to increase the level of effective pollination are handicapped by low knowledge about the pollinators of cupuassu and their behavior.
Resumo:
Tese de Doutoramento em Engenharia Química e Biológica (área de conhecimento em Engenharia Enzimática e das Fermentações)
Resumo:
The present study was carried out to evaluate the effect of chitosan-based edible coatings with Aloe vera extract on the postharvest blueberry fruit quality during storage at 5 °C. Firstly, A. vera fractions (pulp and liquid) were extracted from leaves and evaluated in terms of antifungal and antioxidant capacities. The choice of the most adequate chitosan and A. vera fraction concentrations to be incorporated in coating formulation was made based on the wettability of the corresponding coating solutions. Coatings with 0.5% (w/v) chitosan + 0.5% (w/v) glycerol + 0.1% (w/v) Tween 80 + 0.5% (v/v) A. vera liquid fraction presented the best characteristics to uniformly coat blueberry surface. Physico-chemical (i.e., titratable acidity, pH, weight loss) and microbiological analyses of coated blueberries (non-inoculated or artificially inoculated with Botrytis cinerea) were performed during 25 d. Microbiological growth and water loss levels were approximately reduced by 50% and 42%, respectively, in coated blueberries after 25 d compared to uncoated blueberries. After 15 d, weight loss values were 6.2% and 3.7% for uncoated and chitosanA. vera coated blueberries, respectively. Uncoated fruits presented mold contamination after 2 d of storage (2.0 ± 0.32 log CFU g1), whilst fruits with chitosan-based coatings with A. vera presented mold contamination only after 9 d of storage (1.3 ± 0.35 log CFU g1). Overall, coatings developed in this study extend blueberries shelf-life for about 5 d, demonstrating for the first time that the combination of chitosan and A. vera liquid fraction as edible coating materials has great potential in expanding the shelf-life of fruits.
Resumo:
PURPOSE: To determine the frequency of coronary artery disease, microalbuminuria and the relation to lipid profile disorders, blood pressure and clinical and metabolic features. METHODS: Fifty-five type 2 diabetic patients (32 females, 23 males), aged 59.9±9 years and with known diabetes duration of 11±7.3 years were studied. Coronary artery disease (CAD) was defined as a positive history of myocardial infarction, typical angina, myocardial revascularization or a positive stress testing. Microalbuminuria was defined when two out of three overnight urine samples had a urinary albumin excretion ranging 20 - 200µg/min. RESULTS: CAD was present in 24 patients (43,6%). High blood pressure (HBP) present in 32 patients (58.2%) and was more frequent in CAD group (p=0.05) HBP. Increased the risk of CAD 3.7 times (CI[1.14-12]). Microalbuminuria was present in 25 patients (45.5%) and tended to associate with higher systolic blood pressure (SBP) (p = 0.06), presence of hypertension (p = 0.06) and know diabetes duration (p = 0.08). In the stepwise multiple logistic regression the systolic blood pressure was the only variable that influenced UAE (r = 0.39, r² = 0.14, p = 0.01). The h ypertensive patients had higher cholesterol levels (p = 0.04). CONCLUSION: In our sample the frequency of microalbuminuria, hypertension, hypercholesterolemia and CHD was high. Since diabetes is an independent risk factor for cardiovascular disease, the association of others risk factors suggest the need for an intensive therapeutic intervention in primary and in secundary prevention.
Resumo:
PURPOSE: The authors analyzed the 30-day and 6-month outcomes of 1,126 consecutive patients who underwent coronary stent implantation in 1996 and 1997. METHODS: The 30-day results and 6-month angiographic follow-up were analyzed in patients treated with coronary stents in 1996 and 1997. All patients underwent coronary stenting with high-pressure implantation (>12 atm) and antiplatelet drug regimen (aspirin plus ticlopidine). RESULTS: During the study period, 1,390 coronary stents were implanted in 1,200 vessels of 1,126 patients; 477 patients were treated in the year 1996 and 649 in 1997. The number of percutaneous procedures performed using stents increased significantly in 1997 compared to 1996 (64 % vs 48%, p=0.0001). The 30-day results were similar in both years; the success and stent thrombosis rates were equal (97% and 0.8%, respectively). The occurrence of new Q wave MI (1.3% vs 1.1%, 1996 vs 1997, p=NS), emergency coronary bypass surgery (1% vs 0.6%, 1996 vs 1997, p=NS) and 30-day death rates (0.2% vs 0.5%, 1996 vs 1997, p=NS) were similar. The 6-month restenosis rate was 25% in 1996 and 27% in 1997 (p= NS); the target vessel revascularization rate was 15% in 1996 and 16% in 1997 (p = NS). CONCLUSIONS: Intracoronary stenting showed a high success rate and a low incidence of 30-day occurrence of new major coronary events in both periods, despite the greater angiographic complexity of the patients treated with in 1997. These adverse variables did not have a negative influence at the 6-month clinical and angiographic follow-up, with similar rates of restenosis and ischemia-driven target lesion revascularization rates.
Resumo:
OBJECTIVE: To evaluate the use of the intraaortic balloon (IAoB) in association with coronary angioplasty in high-risk patients. METHODS: Fourteen high-risk patients unresponsive to clinical therapy and with formal contraindication to surgical revascularization were treated by coronary angioplasty, most of which was followed by stenting. All procedures were performed with circulatory support with the IAoB. This study reports the early results and the late findings after 12 months of follow-up. Six patients had multivessel coronary disease; of these, four had left main equivalent lesions and two had unprotected left main coronary artery disease, one of whom had severe "end-vessel" stenosis and the other was a patient with Chagas' disease with single-vessel lesion. Eleven patients had a left ventricular ejection fraction <30%. RESULTS: In 100% of the patients, the procedures were initially successful. Two patients had severe bleeding during the withdrawal of the left femoral sheath. At the end of twelve months, 4 patients were asymptomatic and the others were clinically controlled. There were two late deaths in the 7th and 11th months. CONCLUSION: The combined use of the intraaortic balloon pump and percutaneous coronary angioplasty in high-risk patients with acute ischemic syndromes provides the necessary hemodynamic stability to successfully perform the procedures.
Resumo:
OBJECTIVE - This study compared the early and late results of the use of one single stent with those of the use of multiple stents in patients with lesions longer than 20mm. METHODS - Prospective assessment of patients electively treated with stents, with optimal stent deployment and followed-up for more than 3 months. From February '94 to January '98, 215 patients with lesions >20mm were treated. These patients were divided into 2 groups as follows: Group A - 105 patients (49%) with one stent implanted; Group B - 110 patients (51%) with multiple stents implanted. RESULTS - The mean length of the lesions was 26mm in group A (21-48mm) versus 29mm in group B (21-52mm) (p=0.01). Major complications occurred in one patient (0.9%) in group A (subacute thrombosis, myocardial infarctionand death) and in 2 patients (1.8%) in group B (one emergency surgery and one myocardial infarction) (p=NS). The results of the late follow-up period (>6 months) were similar for both groups (group A = 82% vs group B = 76%; p=NS), and we observed an event-free survical in 89% of the patients in group A and in 91% of the patients in group B (p=NS). Angina (group A = 11% vs group B = 7%) and lesion revascularization (group A = 5% vs group B = 6%; p=NS) also occurred in a similar percentage. No infarction or death was observed in the late follow-up period; restenosis was identified in 33% and 29% of the patients in groups A and B, respectively (p=NS). CONCLUSION - The results obtained using one stent and using multiple stents were similar; the greater cost-effectiveness of one stent implantation, however, seems to make this strategy the first choice.
Resumo:
OBJECTIVE: Comparative analysis of the in-hospital results after primary implantation of stents or coronary balloon angioplasty in patients with acute myocardial infarction (MI). METHODS: CENIC (National Center of Cardiovascular Interventions) gathered data on 3,924 patients undergoing coronary angioplasty (in the primary form, without the previous use of thrombolytic agents) in the first 24 hours after a MI, during the period of 1996-1998. From these 3,924 patients, 1,337 (34%) underwent stent implantation. We analyzed the success of the procedure and the occurrence of adverse cardiac events. RESULTS: In patients undergoing stent implantation there were more males (77% vs 69%, p=0.001), previous by pass surgery (6.3% vs. 4.5%, p=0.01), anterior MI and stent implantation in left descending artery (55% vs. 48% vs. p=0.009), and saphenous vein bypass grafts (3.3% vs. 1.9%). the procedure was more succesful in the group of stents (97% vs. 84%, p=0.001) and reinfarction rate (2.5 vs. 4%, p=0.002). The need for emergency revascularization was similar (1% vs. 1.1%, NS). Total in-hospital mortality was lower in stent group (3.4% vs. 7. 2%, p=0.0001) and this effect was in patients Killip class III/V (19.5% vs. 32.5%, p= 0.002) because there was no difference in patients class I/II (1.7% vs. 2.8%, p=0.9). CONCLUSION: Primary stent implantation in acute myocardial infarction showed better early results than balloon angioplasty alome.
Resumo:
OBJECTIVE: To evaluate the early outcome of mitral valve prostheses implantation and left ventricular remodeling in 23 patients with end-stage cardiomyopathy and secondary mitral regurgitation (NYHA class III and IV). METHODS: Mitral valvular prosthesis implantation with preservation of papillary muscles and chordae tendinae, and plasty of anteriun cuspid for remodeling of the left ventricle. RESULTS: The surgery was performed in 23 patients, preoperative ejection fraction (echocardiography) varied from 13% to 44% (median: 30%). In 13 patients associated procedures were performed: myocardial revascularization (9), left ventricle plicature repair (3) and aortic prosthese implantation (1). Early deaths (2) occurred on the 4th PO day (cardiogenic shock) and on the 20th PO day (upper gastrointestinal bleeding), and a late death in the second month PO (ventricular arrhythmia). Improvement occurred in NYHA class in 82.6% of the patients (P<0.0001), with a survival rate of 86.9% (mean of 8.9 months of follow-up). CONCLUSION: This technique offers a promising therapeutic alternative for the treatment of patients in refractory heart failure with cardiomyopathy and secondary mitral regurgitation.
Resumo:
OBJECTIVE: Evaluation of inter and intraobserver reproducibility of by the visual method interpretation of cineangiogram in a clinically based context. METHODS: Five interventional cardiologists analyzed 11 segments of 8 coronary cineangiograms at a two month apart sessions. The percent luminal reduction by the lesions were analyzed by two different classifications: in one (A) the lesions were graded in 0% = absent, 1-50% = mild, 51 - 69 = moderate, and > or = 70% = severe; the other classification (B) was a dichotomic one : <70% = nonsignificant and > or = 70%=significant lesions. The agreement were measured by the kappa (k) index. RESULTS: Interobserver agreement was moderate for classification A (1st measurement, k = 0.36 -- 0.63, k m = 0.49; 2nd measurement, k = 0.39-0.68, k m = 0.52) and good for classification B (1st measurement, k = 0.55-0.73, k m = 0.63; 2nd measurement, k = 0.37-0.82, k m = 0.61). Intraobserver levels of agreement were k = 0.57-0.95 for classification A and 0.62-1.0 for classification B. CONCLUSION: The higher level of reproducibility obtained by adopting the dichotomous criteria usually considered for ischemic limits demonstrates that in the present clinical context, the reliability of the simple visual method is adequate for the identification of patients with clinically significant lesions and candidates for myocardial revascularization procedures.
Resumo:
We report the case of a 40-year-old woman with 2 previous myocardial infarctions, revascularization surgery, and an ongoing pregnancy complicated with preeclampsia and fetal hypoxia. Her follow-up performed by a multidisciplinary team made possible the birth through cesarean section of a premature infant of the female sex with a very low birth weight, but without severe respiratory distress of the hyaline membrane disease type. Three months after the delivery, mother and daughter were healthy.
Resumo:
OBJECTIVE: To assess safety and efficacy of coronary angioplasty with stent implantation in unstable coronary syndromes. METHODS: Retrospective analysis of in-hospital and late evolution of 74 patients with unstable coronary syndromes (unstable angina or infarction without elevation of the ST segment) undergoing coronary angioplasty with stent placement. These 74 patients were compared with 31 patients with stable coronary syndromes (stable angina or stable silent ischemia) undergoing the same procedure. RESULTS: No death and no need for revascularization of the culprit artery occurred in the in-hospital phase. The incidences of acute non-Q-wave myocardial infarction were 1.4% and 3.2% (p=0.6) in the unstable and stable coronary syndrome groups, respectively. In the late follow-up (11.2±7.5 months), the incidences of these events combined were 5.7% in the unstable coronary syndrome group and 6.9% (p=0.8) in the stable coronary syndrome group. In the multivariate analysis, the only variable with a tendency to significance as an event predictor was diabetes mellitus (p=0.07; OR=5.2; 95% CI=0.9-29.9). CONCLUSION: The in-hospital and late evolutions of patients with unstable coronary syndrome undergoing angioplasty with intracoronary stent implantation are similar to those of the stable coronary syndrome group, suggesting that this procedure is safe and efficacious when performed in unstable coronary syndrome patients.