962 resultados para Pre-design


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis a CMOS low-power and low-voltage RF receiver front-end is presented. The main objective is to design this RF receiver so that it can be powered by a piezoelectric energy harvesting power source, included in a Wireless Sensor Node application. For this type of applications the major requirements are: the low-power and low-voltage operation, the reduced area and cost and the simplicity of the architecture. The system key blocks are the LNA and the mixer, which are studied and optimized with greater detail, achieving a good linearity, a wideband operation and a reduced introduction of noise. A wideband balun LNA with noise and distortion cancelling is designed to work at a 0.6 V supply voltage, in conjunction with a double-balanced passive mixer and subsequent TIA block. The passive mixer operates in current mode, allowing a minimal introduction of voltage noise and a good linearity. The receiver analog front-end has a total voltage conversion gain of 31.5 dB, a 0.1 - 4.3 GHz bandwidth, an IIP3 value of -1.35 dBm, and a noise figure lower than 9 dB. The total power consumption is 1.9 mW and the die area is 305x134.5 m2, using a standard 130 nm CMOS technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The “CMS Safety Closing Sensors System” (SCSS, or CSS for brevity) is a remote monitoring system design to control safety clearance and tight mechanical movements of parts of the CMS detector, especially during CMS assembly phases. We present the different systems that makes SCSS: its sensor technologies, the readout system, the data acquisition and control software. We also report on calibration and installation details, which determine the resolution and limits of the system. We present as well our experience from the operation of the system and the analysis of the data collected since 2008. Special emphasis is given to study positioning reproducibility during detector assembly and understanding how the magnetic fields influence the detector structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

WEB DESIGN COMO FERRAMENTA DE COMUNICAÇÃO DIGITAL: DESIGN E DESENVOLVIMENTO DE SITES, UTILIZANDO O GESTOR DE CONTEÚDOS WORDPRESS; DESIGN DE CONTEÚDOS VISUAIS PARA O FACEBOOK DE UMA MARCA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Field Lab in Entrepreneurial Innovative Ventures

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: Objectivo: Este estudo teve por objectivo descrever a prática clínica e os resultados da intervenção da fisioterapia, às 6, 12 e 24 semanas, em indivíduos após ligamentoplastia do LCA. Introdução: O sucesso da ligamentoplastia do LCA está directamente relacionado com a reabilitação após a realização da mesma, permitindo ao utente o retorno a um estilo de vida activo. Apesar de se saber que um programa de reabilitação estruturado e baseado na evidência tem um papel fulcral nos resultados após cirurgia, e de existir consenso sobre a efectividade destes programas após a cirurgia, o mesmo não se pode afirmar acerca de quais os melhores componentes que devem fazer parte desse programa. Tendo em conta a heterogeneidade encontrada na literatura, no que diz respeito à nomenclatura utilizada, às diferenças de duração dos protocolos e às variações significativas nas recomendações dos cuidados de reabilitação, torna-se primordial a realização duma caracterização da prática clínica da fisioterapia em indivíduos submetidos a ligamentoplastia em Portugal, e consequentemente, descrever quais os resultados obtidos ao nível da incapacidade funcional, intensidade de dor e percepção global de melhoria. Metodologia: Realizou-se um estudo de série de casos, com uma amostra de conveniência, do tipo não probabilístico, constituída por 14 utentes referidos para 4 clínicas de fisioterapia e para 3 hospitais, e que cumpriam os critérios de inclusão e exclusão estabelecidos. Os utentes foram avaliados em 4 momentos pré-definidos: na 1ª sessão de fisioterapia e às 6, 12 e 24 semanas após cirurgia. Os resultados obtidos após intervenção da fisioterapia foram descritos ao nível da incapacidade funcional, da intensidade da dor e da percepção global de melhoria. Paralelamente realizou-se uma caracterização da prática clínica relativamente às modalidades utilizadas, número de sessões de tratamento e duração do episódio de cuidados. Resultados: Observou-se uma tendência de melhoria ao longo das 24 semanas em todas as dimensões da Knee injury and Osteoarthritis Outcome Score (KOOS) e na Escala Numérica da Dor (END), assim como na percepção de melhoria pelo utente, medida através da Patient Global Impression of Change Scale (PGIC). Às 6 semanas, as melhorias nas variáveis de resultados foram superiores às encontradas às 12 e 24 semanas, ao nível da incapacidade funcional (à excepção das dimensões KOOS – actividades desportivas e de lazer e KOOS - qualidade de vida) e dor. Relativamente à intervenção da fisioterapia observou-se uma grande heterogeneidade nas modalidades e procedimentos utilizados. Em média realizaram-se 58,14 (±14,15) sessões, sendo que 71 foi o número de sessões mais utilizado. Conclusão: Os resultados deste estudo sugerem que apesar da heterogeneidade da prática clínica, a intervenção da fisioterapia proporciona melhorias ao nível da capacidade funcional e da dor, em indivíduos submetidos a ligamentoplastia do LCA e que essas melhorias são percepcionadas pelos participantes como clinicamente importantes. ---------ABSTRACT: Objective: The aim of this study was to describe the clinical practice and the results of physical therapy intervention, at 6, 12 and 24 weeks, in subjects after ACL reconstruction. Introduction: The success of ACL reconstruction is directly related with the rehabilitation after the surgery, allowing the patient to an active lifestyle return. Despite knowing that a rehabilitation program based on evidence and well designed has a key role in the results after surgery, the same cannot be said about what the best components that should make part of this program. Taking into account the heterogeneity found in the literature, whether at the level of the nomenclature used, whether at level of the differences in duration of the protocols, as well as the existence of recommendations of rehabilitative care that present significant variations at the international level, it becomes paramount to achieving a characterization of the clinical practice of physical therapy in subjects after ACL reconstruction in Portugal, and consequently describe the results obtained regarding to functional disability and pain intensity. Methodology: A case series design with a convenience sample of 14 patients referred to 7 different outpatients physical therapy settings, that fulfilled the pre- established inclusion and exclusion criteria. Patients were evaluated in four pre-defined moments: in the first session of physiotherapy and at 6, 12 and 24 weeks after surgery. The results obtained after physiotherapy intervention were described at the level of functional disability, pain and global perception of change. Subsequently, it was proceeded the characterization the practice of physical therapy regarding to the modalities used, the number of treatment sessions and duration of the episode of care. Results: It was found that there was a trend of improvement, clinically important, over the 24 weeks in all dimensions of Knee injury and Osteoarthritis Outcome Score (KOOS) and in the Numerical Pain Rating Scale (NPRS). At 6 weeks, improvements were superior to those found at 12 and 24 weeks, at the level of functional disability (with the exception of the KOOS-sports and recreation function and KOOS-knee related quality of life dimensions) and pain. As regards the intervention of physical therapy found that the heterogeneity encountered both at the level of clinical practice as evidence,are difficult to compare. On average 58,14 (±14,15) sessions were held, with 71 was the most commonly used sessions numbers. Conclusion: The results of this study suggest that in spite of the heterogeneity of clinical practice, physical therapy intervention provides improvements in terms of functional disability and pain in subjects after ACL reconstruction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The following work project illustrates the strategic issues There App, a mobile application, faces regarding the opportunity to expand from its current state as a product to a multisided platform. Initially, a market analysis is performed to identify the ideal customer groups to be integrated in the platform. Strategic design issues are then discussed on how to best match its value proposition with the identified market opportunity. Suggestions on how the company should organize its resources and operational processes to best deliver on its value proposition complete the work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work project aims to demonstrate how to design and develop an innovative concept of video streaming app. The project combines technology push and market pull theories into developing a product that is more suitable for the customer needs, with the particularity that there is no other way of seeing any place in the world, live and ondemand. An analysis on the bigger influencers in terms of design-thinking and new product development, as Tim Brown or Paul Trott, lead to a better understanding on how There App should evolve, keeping in mind the customer desires and technical features.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of this thesis was the development of polymeric structures from the dissolution of FucoPol, a bacterial exopolysaccharide (EPS), in a biocompatible ionic liquid, choline acetate. The FucoPol was produced by the bacteria Enterobacter A47 using glycerol as carbon source at controlled temperature and pH (30ºC and 7, respectively). At the end of 3 days it was produced 7 g/L of FucoPol. The net yield of Fucopol in glycerol (YP/S) was 0.22 g/g and the maximum productivity 2.37 g/L.d This polymer was characterized about its composition in sugars and acyl groups (by High-Performance Liquid Chromatography - HPLC), containing fucose (35 % mol), galactose (21 % mol), glucose (29 % mol), rhamnose (3% mol) and glucuronic acid (12% mol) as well as acetate (14.28 % mol), pyruvate (2.15 % mol) and succinate (1.80 % mol). Its content of water and ash was 15% p/p and 2% p/p, respectively, and the chemical bonds (determined by Infrared Spectroscopy - FT-IR) are consistent to the literature reports. However, due to limitations in Differential Scanning Calorimetry (DSC) equipment it was not possible to determine the glass transition temperature. In turn, the ionic liquid showed the typical behavior of a Newtonian fluid, glass transition temperature (determined by DSC) -98.03ºC and density 1.1031 g/cm3. The study of chemical bonds by FT-IR showed that amount of water (8.80%) influenced the visualization of the bands predicted to in view of their chemical structure. After the dissolution of the FucoPol in the ionic liquid at different temperatures (50, 60, 80 and 100 ° C) it was promoted the removal of this by the phase inversion method using deionized water as a solvent, followed by drying in an oven at 70 ° C. The mixtures before and after the phase inversion method were characterized through the studies mentioned above. In order to explore possible application field’s biocompatibility assays and collage on balsa wood tests were performed. It was found that the process of washing with water by the phase inversion method was not totally effective in removing the biocompatible ionic liquid, since all FucoPol – IL mixtures still contained ionic liquid in their composition as can be seen by the DSC results and FT-IR. In addition, washing the mixtures with water significantly altered the composition of FucoPol. However, these mixtures, that developed a viscous behavior typical of a non-Newtonian fluid (shear-thinning), have the potential to be applied in the biomedical field as well as biological glues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simulated moving bed (SMB) chromatography is attracting more and more attention since it is a powerful technique for complex separation tasks. Nowadays, more than 60% of preparative SMB units are installed in the pharmaceutical and in the food in- dustry [SDI, Preparative and Process Liquid Chromatography: The Future of Process Separations, International Strategic Directions, Los Angeles, USA, 2002. http://www. strategicdirections.com]. Chromatography is the method of choice in these ¯elds, be- cause often pharmaceuticals and ¯ne-chemicals have physico-chemical properties which di®er little from those of the by-products, and they may be thermally instable. In these cases, standard separation techniques as distillation and extraction are not applicable. The noteworthiness of preparative chromatography, particulary SMB process, as a sep- aration and puri¯cation process in the above mentioned industries has been increasing, due to its °exibility, energy e±ciency and higher product purity performance. Consequently, a new SMB paradigm is requested by the large number of potential small- scale applications of the SMB technology, which exploits the °exibility and versatility of the technology. In this new SMB paradigm, a number of possibilities for improving SMB performance through variation of parameters during a switching interval, are pushing the trend toward the use of units with smaller number of columns because less stationary phase is used and the setup is more economical. This is especially important for the phar- maceutical industry, where SMBs are seen as multipurpose units that can be applied to di®erent separations in all stages of the drug-development cycle. In order to reduce the experimental e®ort and accordingly the coast associated with the development of separation processes, simulation models are intensively used. One impor- tant aspect in this context refers to the determination of the adsorption isotherms in SMB chromatography, where separations are usually carried out under strongly nonlinear conditions in order to achieve higher productivities. The accurate determination of the competitive adsorption equilibrium of the enantiomeric species is thus of fundamental importance to allow computer-assisted optimization or process scale-up. Two major SMB operating problems are apparent at production scale: the assessment of product quality and the maintenance of long-term stable and controlled operation. Constraints regarding product purity, dictated by pharmaceutical and food regulatory organizations, have drastically increased the demand for product quality control. The strict imposed regulations are increasing the need for developing optically pure drugs.(...)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Release of chloroethene compounds into the environment often results in groundwater contamination, which puts people at risk of exposure by drinking contaminated water. cDCE (cis-1,2-dichloroethene) accumulation on subsurface environments is a common environmental problem due to stagnation and partial degradation of other precursor chloroethene species. Polaromonas sp. strain JS666 apparently requires no exotic growth factors to be used as a bioaugmentation agent for aerobic cDCE degradation. Although being the only suitable microorganism found capable of such, further studies are needed for improving the intrinsic bioremediation rates and fully comprehend the metabolic processes involved. In order to do so, a metabolic model, iJS666, was reconstructed from genome annotation and available bibliographic data. FVA (Flux Variability Analysis) and FBA (Flux Balance Analysis) techniques were used to satisfactory validate the predictive capabilities of the iJS666 model. The iJS666 model was able to predict biomass growth for different previously tested conditions, allowed to design key experiments which should be done for further model improvement and, also, produced viable predictions for the use of biostimulant metabolites in the cDCE biodegradation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente relatório de estágio enquadra-se no método de avaliação final do Mestrado em Novos Media e Práticas Web, da Faculdade de Ciências Sociais e Humanas da Universidade Nova de Lisboa e pretende abordar o trabalho desenvolvido por mim durante o estágio curricular realizado na agência de comunicação e publicidade Ogilvy. O estágio decorreu entre novembro de 2014 e fevereiro de 2015, durante o qual desempenhei o cargo de online producer e fui supervisionada por Sara Cabral Fonseca, diretora de projeto. Todos os trabalhos tiveram como objetivo principal o acompanhamento e conhecimento do processo ligado ao desenvolvimento de projetos digitais, desde o briefing até à programação e conteúdo. Os trabalhos compreenderam a realização de testes de usabilidade em deskop e mobile dos sites e aplicações desenvolvidos pelo departamento digital da empresa, e também o apoio na realização de tarefas ligadas à gestão de conteúdos de vários websites. Este relatório resulta de todo o trabalho concretizado e pretende efetuar uma contextualização teórica ligada à importância dos testes de usabilidade e do Responsive Web Design (RWD) na implementação de projetos digitais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction In Brazil, little data exist regarding the distribution of genotypes in relation to basal core promoter (BCP) and precore/core mutations among chronic hepatitis B virus (HBV) carriers from different regions of the country. The aim of this study was to identify HBV genotypes and the frequency of mutations at the BCP and precore/core region among the prevalent genotypes in chronic carriers from southern Brazil. Methods Nested-polymerase chain reaction (nested-PCR) products amplified from the S-polymerase gene, BCP and precore/core region from 54 samples were sequenced and analyzed. Results Phylogenetic analysis of the S-polymerase gene sequences showed that 66.7% (36/54) of the patients were infected with genotype D (D1, D2, D3), 25.9% (14/54) with genotype A (A1, A2), 5.6% (3/54) with subgenotype C2, and 2% (1/54) with genotype E. A comparison of virological characteristics showed significant differences between genotypes A, C and D. The comparison between HBeAg status and the G1896A stop codon mutation in patients with genotype D revealed a relationship between HBV G1896A precore mutants and genotype D and hepatitis B e antigen (HBeAg) seroconversion. Genotype D had a higher prevalence of the G1896A mutation and the presence of a thymine at position 1858. Genotype A was associated with a higher prevalence of the G1862T mutation and the presence of a cytosine at position 1858. Conclusions HBV genotype D (D3) is predominant in HBV chronic carriers from southern Brazil. The presence of mutations in the BCP and precore/core region was correlated with the HBV genotype and HBeAg negative status.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design of anchorage blisters of internal continuity post-tensioning tendons of bridges built by the cantilever method, presents some peculiarities, not only because they are intermediate anchorages but also because these anchorages are located in blisters, so the prestressing force has to be transferred from the blister the bottom slab and web of the girder. The high density of steel reinforcement in anchorage blisters is the most common reason for problems with concrete cast in situ, resulting in zones with low concrete compacity, leading to concrete crushing failures under the anchor plates. A solution may involve improving the concrete compression and tensile strength. To meet these requirements a high-performance fibre reinforced self-compacting mix- ture (HPFRC) was used in anchorage corner blisters of post-tensioning tendons, reducing the concrete cross-section and decreasing the reinforcement needed. To assess the ultimate capacity and the adequate serviceability of the local anchorage zone after reducing the minimum concrete cross-section and the confining reinforcement, specified by the anchorage device supplier for the particular tendon, load transfer tests were performed. To investigate the behaviour of anchorage blisters regarding the transmission of stresses to the web and the bottom slab of the girder, and the feasibility of using high performance concrete only in the blister, two half scale models of the inferior corner of a box girder existing bridge were studied: a reference specimen of ordinary reinforced concrete and a HPFRC blister specimen. The design of the reinforcement was based in the tensile forces obtained on strut-and-tie models. An experimental program was carried out to assess the models used in design and to study the feasibility of using high performance concrete only in the blister, either with casting in situ, or with precast solutions. A non-linear finite element analysis of the tested specimens was also performed and the results compared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work has its origin on the necessity of enabling a design certified company, or DOA (Design Organization Approval), to perform a modification; this modification is the installation of EO/IR (Electro-optical infrared) sensors on aircrafts. The subject of interest in this dissertation lies on the aerodynamic impact of the modification on the aircraft. The primary purpose of the present thesis is the creation of a methodology that regards the design stage of the modification. This methodology serves as guidance to the DOA design team that is assigned to the design of the modification. The methodology includes a recommendation to the certification of the modification; it contains a method intended to decide the location of the installation of the sensors on the aircraft; it also comprises of a design structure specifically adapted to the modification in study. Regarding the aerodynamic impact, it is studied the aerodynamic analysis’ tools, which allows one to relate the different stages of design to the most suited tools to each stage. A case study is performed with the purpose of not only validating the methodology which was created but also to giving a first approach to the preliminary design of the modification. As example, there are used the Lockheed Martin C-130 aircraft and the FLIR Star Safire III sensor.