966 resultados para Power circuit
Resumo:
In this study of symbolic power relations in a transnational merger, we suggest that the popular media can provide a significant arena for (re)constructing national identities and power in this kind of dramatic industrial restructuring, and are an under-utilized source of empirical data in research studies. Focusing on the press coverage of a recent Swedish-Finnish merger, we specify and illustrate a particular feature of discursive (re)construction of asymmetric power relations; superior (Swedish) and inferior (Finnish) national identities, which, we argue, are embedded in the history of colonization and domination between the two nations. The findings of the present study lead us to suggest that a lens taken from post-colonial theory is particularly useful in understanding the wider symbolic power implications of international industrial restructuring.
Resumo:
We argue in this paper that corporate language policies have significant power implications that are easily overlooked. By drawing on previous work on power in organizations (Clegg, 1989), we examine the complex power implications of language policy decisions by looking at three levels of analysis: episodic social interaction, identity/subjectivity construction, and reconstruction of structures of domination. In our empirical analysis, we focus on the power implications of the choice of Swedish as the corporate language in the case of the recent banking sector merger between the Finnish Merita and the Swedish Nordbanken. Our findings show how language skills become empowering or disempowering resources in organizational communication, how these skills are associated with professional competence, and how this leads to the creation of new social networks. The case also illustrates how language skills are an essential element in the construction of international confrontation, lead to a construction of superiority and inferiority, and also reproduce post-colonial identities in the merging bank. Finally, we also point out how such policies ultimately lead to the reification of post-colonial and neo-colonial structures of domination in multinational corporations.
Resumo:
We argue in this paper that corporate language policies have significant power implications that are easily overlooked. By drawing on previous work on power in organizations (Clegg, 1989), we examine the complex power implications of language policy decisions by looking at three levels of analysis: episodic social interaction, identity/subjectivity construction, and reconstruction of structures of domination. In our empirical analysis, we focus on the power implications of the choice of Swedish as the corporate language in the case of the recent banking sector merger between the Finnish Merita and the Swedish Nordbanken. Our findings show how language skills become empowering or disempowering resources in organizational communication, how these skills are associated with professional competence, and how this leads to the creation of new social networks. The case also illustrates how language skills are an essential element in the construction of international confrontation, lead to a construction of superiority and inferiority, and also reproduce post-colonial identities in the merging bank. Finally, we also point out how such policies ultimately lead to the reification of post-colonial and neo-colonial structures of domination in multinational corporations.
Resumo:
We develop an alternate characterization of the statistical distribution of the inter-cell interference power observed in the uplink of CDMA systems. We show that the lognormal distribution better matches the cumulative distribution and complementary cumulative distribution functions of the uplink interference than the conventionally assumed Gaussian distribution and variants based on it. This is in spite of the fact that many users together contribute to uplink interference, with the number of users and their locations both being random. Our observations hold even in the presence of power control and cell selection, which have hitherto been used to justify the Gaussian distribution approximation. The parameters of the lognormal are obtained by matching moments, for which detailed analytical expressions that incorporate wireless propagation, cellular layout, power control, and cell selection parameters are developed. The moment-matched lognormal model, while not perfect, is an order of magnitude better in modeling the interference power distribution.
Resumo:
The effects of power-law plasticity (yield strength and strain hardening exponent) on the plastic strain distribution underneath a Vickers indenter was systematically investigated by recourse to three-dimensional finite element analysis, motivated by the experimental macro-and micro-indentation on heat-treated Al-Zn-Mg alloy. For meaningful comparison between simulated and experimental results, the experimental heat treatment was carefully designed such that Al alloy achieve similar yield strength with different strain hardening exponent, and vice versa. On the other hand, full 3D simulation of Vickers indentation was conducted to capture subsurface strain distribution. Subtle differences and similarities were discussed based on the strain field shape, size and magnitude for the isolated effect of yield strength and strain hardening exponent.
Resumo:
Design of high-frequency inductors for purposes like Active Front End (AFE) converter filters involves analytical calculations based on methods like area product approach and accurate graphical methods. Once a core with an area product is selected the subsequent calculations of inductance and peak operating flux requires the estimation of reluctance of the magnetic circuit. This in turn demands an estimate of the fringing that will happen in the air gap of the inductor. In this paper we have looked at analytical methods for evaluating fringing flux and compared it with results from finite element method. Different levels of details of modelling the inductor is first considered for this purpose. The end results are compared with experimental measurements of inductance. It is shown that simple fringing flux model can provide accurate models for the inductor design.
Resumo:
The performance of a plate clutch in a two-inertia power transmission system is analysed assuming negligible compliance and using a piecewise linear function to represent the clutch torque characteristic. Expressions defining, for all linear segments of the clutch torque characteristic, dimensionless input and output velocities of the clutch and dimensionless slip period are presented. The use of these expressions in preparing design charts to aid analysis and design of the plate clutch is outlined.
Resumo:
Lead acid batteries are used in hybrid vehicles and telecommunications power supply. For reliable operation of these systems, an indication of state of charge of battery is essential. To determine the state of charge of battery, current integration method combined with open circuit voltage, is being implemented. To reduce the error in the current integration method the dependence of available capacity as a function of discharge current is determined. The current integration method is modified to incorporate this factor. The experimental setup built to obtain the discharge characterstics of the battery is presented.
Resumo:
The aim of the current study is to examine the influence of the channel external environment on power, and the effect of power on the distribution network structure within the People’s Republic of China. Throughout the study a dual research process was applied. The theory was constructed by elaborating the main theoretical premises of the study, the channel power theories, the political economy framework and the distribution network structure, but these marketing channel concepts were expanded with other perspectives from other disciplines. The main method applied was a survey conducted among 164 Chinese retailers, complemented by interviews, photographs, observations and census data from the field. This multi-method approach enabled not only to validate and triangulate the quantitative results, but to uncover serendipitous findings as well. The theoretical contribution of the current study to the theory of marketing channels power is the different view it takes on power. First, earlier power studies have taken the producer perspective, whereas the current study also includes a distributor perspective to the discussion. Second, many power studies have dealt with strongly dependent relationships, whereas the current study examines loosely dependent relationships. Power is dependent on unequal distribution of resources rather than based on high dependency. The benefit of this view is in realising that power resources and power strategies are separate concepts. The empirical material of the current study confirmed that at least some resources were significantly related to power strategies. The study showed that the dimension resources composed of technology, know-how and knowledge, managerial freedom and reputation was significantly related to non-coercive power. Third, the notion of different outcomes of power is a contribution of this study to the channels power theory even though not confirmed by the empirical results. Fourth, it was proposed that channel external environment other than the resources would also contribute to the channel power. These propositions were partially supported thus providing only partial contribution to the channel power theory. Finally, power was equally distributed among the different types of actors. The findings from the qualitative data suggest that different types of retailers can be classified according to the meaning the actors put into their business. Some are more business oriented, for others retailing is the only way to earn a living. The findings also suggest that in some actors both retailing and wholesaling functions emerge, and this has implications for the marketing channels structure.
Resumo:
The low predictive power of implied volatility in forecasting the subsequently realized volatility is a well-documented empirical puzzle. As suggested by e.g. Feinstein (1989), Jackwerth and Rubinstein (1996), and Bates (1997), we test whether unrealized expectations of jumps in volatility could explain this phenomenon. Our findings show that expectations of infrequently occurring jumps in volatility are indeed priced in implied volatility. This has two important consequences. First, implied volatility is actually expected to exceed realized volatility over long periods of time only to be greatly less than realized volatility during infrequently occurring periods of very high volatility. Second, the slope coefficient in the classic forecasting regression of realized volatility on implied volatility is very sensitive to the discrepancy between ex ante expected and ex post realized jump frequencies. If the in-sample frequency of positive volatility jumps is lower than ex ante assessed by the market, the classic regression test tends to reject the hypothesis of informational efficiency even if markets are informationally effective.
Resumo:
A novel ZVS auxiliary switch commutated variation for all DGDC converter topologies has been proposed in 2006. With proper designation of the circuit variables (throw current I and the pole voltage V), all these converters are seen to be governed by an identical set of equations. With idealized switches, the steady-state performance is obtainable in an analytical form. The conversion ratio of the converter topologies is obtained. A generalized equivalent circuit emerges for all these converters from the steady-state conversion ratio. It also provides a dynamic model as well. With these generalized steady-state equivalent circuits, small signal analysis of these converters may be carried out readily. It enables one to use the familiar state space averaged results of the standard PWM DGDC converters for the resonant counterparts. Th dc and ac models reveals that dc and low frequency behaviour of the proposed family of converters is similiar to that of its PWM parent
Resumo:
An algorithm for optimal allocation of reactive power in AC/DC system using FACTs devices, with an objective of improving the voltage profile and also voltage stability of the system has been presented. The technique attempts to utilize fully the reactive power sources in the system to improve the voltage stability and profile as well as meeting the reactive power requirements at the AC-DC terminals to facilitate the smooth operation of DC links. The method involves successive solution of steady-state power flows and optimization of reactive power control variables with Unified Power Flow Controller (UPFC) using linear programming technique. The proposed method has been tested on a real life equivalent 96-bus AC and a two terminal DC system under normal and contingency conditions.
Resumo:
This paper describes an approach for the analysis and design of 765kV/400kV EHV transmission system which is a typical expansion in Indian power grid system, based on the analysis of steady state and transient over voltages. The approach for transmission system design is iterative in nature. The first step involves exhaustive power flow analysis, based on constraints such as right of way, power to be transmitted, power transfer capabilities of lines, existing interconnecting transformer capabilities etc. Acceptable bus voltage profiles and satisfactory equipment loadings during all foreseeable operating conditions for normal and contingency operation are the guiding criteria. Critical operating strategies are also evolved in this initial design phase. With the steady state over voltages obtained, comprehensive dynamic and transient studies are to be carried out including switching over voltages studies. This paper presents steady state and switching transient studies for alternative two typical configurations of 765kV/400 kV systems and the results are compared. Transient studies are carried out to obtain the peak values of 765 kV transmission systems and are compared with the alternative configurations of existing 400 kV systems.
Resumo:
The voltage stability control problem has become an important concern for utilities transmitting power over long distances. This paper presents an approach using fuzzy set theory for reactive power control with the purpose of improving the voltage stability of a power system. To minimize the voltage deviations from pre-desired values of all the load buses, using the sensitivities with respect to reactive power control variables form the basis of the proposed fuzzy logic control (FLC). Control variables considered are switchable VAR compensators, On Load Tap Changing (OLTC) transformers and generator excitations. Voltage deviations and controlling variables are translated into fuzzy set notations to formulate the relation between voltage deviations and controlling ability of controlling devices. The developed fuzzy system is tested on a few simulated practical Indian power systems and some IEEE standard test systems. The performance of the fuzzy system is compared with conventional optimization technique and results obtained are encouraging. Results obtained for a 24 - node equivalent EHV system of part of Indian southern grid and IEEE New England 39-bus system are presented for illustration purposes. The proposed Fuzzy-Expert technique is found suitable for on-line applications in energy control centre as the solution is obtained fast with significant speedups.
Resumo:
Power system disturbances are often caused by faults on transmission lines. When faults occur in a power system, the protective relays detect the fault and initiate tripping of appropriate circuit breakers, which isolate the affected part from the rest of the power system. Generally Extra High Voltage (EHV) transmission substations in power systems are connected with multiple transmission lines to neighboring substations. In some cases mal-operation of relays can happen under varying operating conditions, because of inappropriate coordination of relay settings. Due to these actions the power system margins for contingencies are decreasing. Hence, power system protective relaying reliability becomes increasingly important. In this paper an approach is presented using Support Vector Machine (SVM) as an intelligent tool for identifying the faulted line that is emanating from a substation and finding the distance from the substation. Results on 24-bus equivalent EHV system, part of Indian southern grid, are presented for illustration purpose. This approach is particularly important to avoid mal-operation of relays following a disturbance in the neighboring line connected to the same substation and assuring secure operation of the power systems.