907 resultados para Portable device
Resumo:
Photograph of the internal mechanism of Medicide device (verso)
Resumo:
Mode of access: Internet.
Resumo:
Hearings held July 28-31, 1975.
Resumo:
Mode of access: Internet.
Resumo:
Thesis (Master's)--University of Washington, 2016-06
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-06
Resumo:
We propose a model for non-ideal monitoring of the state of a coupled quantum dot qubit by a quantum tunnelling device. The non-ideality is modelled using an equivalent measurement circuit. This allows realistically available measurement results to be related to the state of the quantum system (qubit). We present a quantum trajectory that describes the stochastic evolution of the qubit state conditioned by tunnelling events (i.e. current) through the device. We calculate and compare the noise power spectra of the current in an ideal and a non-ideal measurement. The results show that when the two qubit dots are strongly coupled the non-ideal measurement cannot detect the qubit state precisely. The limitation of the ideal model for describing a realistic system maybe estimated from the noise spectra.
Resumo:
The efficacy of 1-methylcyclopropene (1-MCP) gas to prevent the adverse effects of ethylene is limited by its short-term residual activity in some plants. Development of a simple 1-MCP sustained release device that prolongs 1-MCP exposure is reported herein. Sustained release devices comprised of polyvinylchloride tubes containing 0.1 g SmartFresh(TM) powder (a.i. 3.3% 1-MCP) and 1.25 ml deionised water were used to release 1-MCP into fibreboard cartons containing cut Geraldton waxflower (Chamelaucium uncinatum Schauer) cv. CWA Pink bunches during export shipment by air (107 h) from Australia to the UK. The devices protected flowers against abscission induced by subsequent test exposures to ethylene (1011,mul l(-1), 12 h, 20 degreesC) for 3-5 days after arrival. In contrast, pre-shipment treatments with either a single application of 790 nl l(-1) 1-MCP for 14 h at 2 degreesC or a 0.2 mM Ag+ (as silver thiosulphate; STS) pulse for 14 h at 2 degreesC protected flowers against exogenous ethylene for only 1-2 days of post-export life. However, pre-shipment 1-MCP fumigation was up to about three-fold more effective than either sustained 1-MCP release or pre-shipment STS treatments in reducing floral organ and leaf abscission from bunches during export. Thus, it is suggested that a combination of pre-shipment 1-MCP fumigation before export with sustained 1-MCP release during shipment should maximise efficacy against ethylene-induced waxflower flower abscission. (C) 2004 Elsevier B. V. All rights reserved.
Resumo:
A new device has been developed to directly measure the bubble loading of particle-bubble aggregates in industrial flotation machines, both mechanical flotation cells as well as flotation column cells. The bubble loading of aggregates allows for in-depth analysis of the operating performance of a flotation machine in terms of both pulp/collection zone and froth zone performance. This paper presents the methodology along with an example showing the excellent reproducibility of the device and an analysis of different operating conditions of the device itself. (C) 2004 Elsevier B.V All rights reserved.
Resumo:
We have used an animal model to test the reliability of a new portable continuous-wave Doppler ultrasonic cardiac output monitor, the USCOM. In six anesthetized dogs, cardiac output was measured with a high-precision transit time ultrasonic flowprobe placed on the ascending aorta. The dogs' cardiac output was increased with a dopamine infusion (0-15 mug (.) kg(-1) (.) min(-1)). Simultaneous flowprobe and USCOM cardiac output measurements were made. Up to 64 pairs of readings were collected from each dog. Data were compared by using the Bland and Altman plot method and Lin's concordance correlation coefficient. A total of 319 sets of paired readings were collected. The mean (+/-SD) cardiac output was 2.62 +/- 1.04 L/min, and readings ranged from 0.79 to 5.73 L/min. The mean bias between the 2 sets of readings was -0.01 L/min, with limits of agreement (95% confidence intervals) of -0.34 to 0.31 L/min. This represents a 13% error. In five of six dogs, there was a high degree of concordance, or agreement, between the 2 methods, with coefficients >0.9. The USCOM provided reliable measurements of cardiac output over a wide range of values. Clinical trials are needed to validate the device in humans.