935 resultados para Polimorfismo de nucleótido simple


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present general explicit expressions for a shell-model calculation of the vector hypernuclear parameter in nonmesonic weak decay. We use a widely accepted effective coupling Hamiltonian involving the exchange of the complete pseudoscalar and vector meson octets (π, η, K, ρ, ω, K*). In contrast to the approximated formula widely used in the literature, we correctly treat the contribution of transitions originated from single-proton states beyond the s-shell. Exact and simple analytical expressions are obtained for the particular cases of Λ 5He and Λ 12C, within the one-pion-exchange model. Numerical computations of the asymmetry parameter, aΛ, are presented. Our results show a qualitative agreement with other theoretical estimates but also a contradiction with recent experimental determinations. Our simple analytical formulas provide a guide in searching the origin of such discrepancies, and they will be useful for helping to solve the hypernuclear weak decay puzzle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cold-formed steel members are subject to failure caused by buckling, normally under loads smaller than those corresponding to partial or total yielding of the cross section. The buckling of members in bending can be classified as local or global, and the occurrence of one or the other type is expected by the members' geometric characteristics and by the constraints and load conditions. One of the local instability modes that can characterize a member's failure is distortional buckling of the cross section occurring on its own plane and involving lateral displacements and rotations. This paper presents and discusses the procedures and results obtained from experimental tests of cold-formed steel members under bending. Forty-eight beams were carried out on members in simple lipped channel, in pairs, with 6-meter spans and loads applied by concentrated forces at every 1/3 of the span. The thickness, width and dimensions, of the stiffeners were chosen so that the instability by distortion buckling of the cross section was the principal failure mode expected. The experimental results are compared with the obtained results by using the direct strength method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate the effect of beta-lactoglobulin polymorphism, breed and seasonality on physico-chemical characteristics and stability of bovine milk. Six Holstein-Zebu (H-Z) and five Holstein dairy herds were selected, of which 660 Holstein and 293 crossbred Holstein-Zebu milk and blood samples were collected, adding up 953 samples, distributed in two collecting periods at rainy and two at dry seasons. Each milk sample was analyzed for titratable acidity, pH, freezing point and milk ethanol stability, at the following ethanol concentrations: 70, 76, 80 and 84GL. Individual blood samples were submitted to polymerase chain reaction (PCR) for the determination of beta-lactoglobulin polymorphism. No effect of beta-lactoglobulin polymorphism was observed in physico-chemical characteristics of milk, in both studied breed. Breed effect for Holstein and H-Z, respectively, was observed on titratable acidity (16.16 and 17.07°D, while effect of seasonality (for rainy and dry seasons, respectively) was also observed on freezing point (-0.5411 and -0.5376°H). Effects of breed and seasonality on milk stability were observed (Holstein-Zebu milk was less stable on dry season), however, no effect of beta-lactoglobulin on milk stability was observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The most significant studies about the spinner dolphin (Stenella longirostris) in the Southwestern Atlantic Ocean were conducted in Fernando de Noronha Archipelago, off Northeastern Brazil. The continuity of these studies depends upon the development of non-invasive methods. In this work, we present results from the skin swabbing sampling procedure for this species. We tested the performance of this method for nuclear and mitochondrial DNA analysis, unknown for this population. A total of skin 161 samples were collected during two expeditions. After the contacts the most of the dolphins remained close to the boat. Microsatellites markers and cytochrome b region primers were evaluated and the respective fragments were successfully amplified. Thus, skin swabbing may be considered an efficient strategy to obtain tissue samples for spinner dolphin genetic analysis in Fernando de Noronha Archipelago.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, rapid and sensitive spectrophotometric method has been developed for the determination of methyldopa in pharmaceutical formulations. The method is based on the reaction between tetrachloro-p-benzoquinone (p-chloranil) and methyldopa, accelerated by hydrogen peroxide (H 2O 2), producing a violet-red compound (λmax = 535 nm) at ambient temperature (25.0 ± 0.2°C). Experimental design methodologies were used to optimize the measurement conditions. Beer's law is obeyed in a concentration range from 2.10 × 10 -4 to 2.48 × 10 -3 mol L -1 (r = 0.9997). The limit of detection was 7.55 × 10 -6 mol L -1 and the limit of quantification was 2.52 × 10 -5 mol L -1. The intraday precision and interday precision were studied for 10 replicate analyses of 1.59 × 10 -3 mol L -1 methyldopa solution and the respective coefficients of variation were 0.7 and 1.1%. The proposed method was successfully applied to the determination of methyldopa in commercial brands of pharmaceuticals. No interferences were observed from the common excipients in the formulations. The results obtained by the proposed method were favorably compared with those given by the Brazilian Pharmacopoeia procedure at 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A previous work showed that viscosity values measured high frequency by ultrasound agreed with the values at low frequency by the rotational viscometer when conditions are met, such as relatively low frequency viscosity. However, these conditions strongly reduce the range of the measurement cell. In order to obtain a measurement range and sensitivity high frequency must used, but it causes a frequency-dependent decrease on the viscosity values. This work introduces a new simple in order to represent this frequency-dependent behavior.model is based on the Maxwell model for viscoelastic , but using a variable parameter. This parameter has physical meaning because it represents the linear behavior the apparent elasticity measured along with the viscosity by .Automotive oils SAE 90 and SAE 250 at 22.5±0.5oC viscosities at low frequency of 0.6 and 6.7 Pa.s, respectively,tested in the range of 1-5 MHz. The model was used in to fit the obtained data using an algorithm of non-linear in Matlab. By including the viscosity at low frequency an unknown fitting parameter, it is possible to extrapolate its . Relative deviations between the values measured by the and extrapolated using the model for the SAE 90 and SAE 250 oils were 5.0% and 15.7%, respectively.©2008 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In spite of the stated Brazilian policy on medicines that their quality, effectiveness and safety should be ensured at reasonable cost, hospitals in the ANVISA Surveillance Network have been receiving notifications of technical complaints, adverse reactions and suspected therapeutic ineffectiveness (STI) of medicines. The purpose of this study was to identify the medicines notified for suspicion of therapeutic ineffectiveness, at a university hospital participating in the national Surveillance Network, and to investigate the existence of polymorphs of any of the drugs involved, by examining the literature. There were 31 notifications of STI in a period of 18 months, concerning 11 different drugs, all of which were 'similar' drugs (neither original nor licensed by originator); five of these could contain polymorphs, according to the literature. However, this does not mean that the other drugs could not contain some unknown polymorphs, more studies being needed on polymorphism, especially in the cases of reported therapeutic ineffectiveness. Therefore, tests of polymorphism should be made part of the routine quality control of the raw materials during the development of medicines and in the studies of pharmaceutical equivalence to 'reference' medicines (innovative brands). The stability test should also involve a study of polymorphism, in order to confirm the solid state stability of the drug. All these measures will assure the effectiveness of medicines, since the reproducibility in the quality of pharmaceutical products could be monitored, as well as the equivalence of each production batch with the batch selected to determine the bioequivalence with the reference brand.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sickle cell disease is an inflammatory condition with a pathophysiology that involves vaso-occlusive episodes. Mutations of the methylenetetrahydrofolate reductase (MTHFR) and cystathionine beta-synthase (CBS) genes are risk factors for vascular disease. Due to the importance of identifying risk factors for vaso-occlusive events in sickle cell patients, we investigated the frequencies of the C677T and 844ins68 mutations of the MTHFR and CBS genes, respectively. Three hundred patients with Hb SS, HB SC and HbS/Beta thalassemia, from Brasília, Goiânia, Rio de Janeiro, São Jose do Rio Preto and São Paulo were evaluated. Samples of 5 mL of venous blood were collected in EDTA after informed consent was received from patients. Classical diagnostic methods were used to confirm the hemoglobin phenotypes. The hemoglobin genotypes and polymorphisms studied were evaluated by Restriction Fragment Length Polymorphism and Allele Specific amplification. The results showed that 93 patients (31.00%) were heterozygous and 13 (4.33%) homozygous for the C677T mutation and 90 were heterozygotes (30.00%) and 8 homozygous (2.66%) for the 844ins68 mutation, both with significant differences for genotype frequency between the localities. The allelic frequencies are in Hardy-Weinberg equilibrium for both polymorphisms. The frequency of mutations was significant and the presence of related vaso-occlusive events was more common in patients with Hb SS (p = 0007). The 844ins68 mutation was approximately three times more frequent in patients with vaso-occlusive complications (p = 0011). The C677T mutation did not prove to be associated with risk of vaso-occlusive events (p = 0.193). A C677T-844ins68 interaction occurred in 12.08% of the patients, doubling the risk of vaso-occlusive manifestations. The frequencies of the polymorphisms are consistent with those expected in the Brazilian population. The presence of the 844ins68 mutation of the CBS gene proved to be a potential risk factor for vaso-occlusive events in sickle cell patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective this article is describe a methodology for the calculation of the profile of the electric field in the level soil and proximities originated by electric energy transmission systems real and in operation in the country. It also is commented the equation used and your computational implementation in order to agile and to optimize the studies. The results of simulations were just presented for the transmission system in the voltage class 500 kV for simplify the understanding and space restriction in the article, very although five others types of configurations have also been used in the complete study with very voltages and respective classes. The results were animating and very nearby of values well-known of electric field of other and publications traditional in the area. The graphic exits of program for better visual comprehension and understanding went in accomplished in the plan and in the space © 2010 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, rapid, accurate and inexpensive spectrophotometric method for the determination of tetracycline and doxycycline has been developed. The method is based on the reaction between these drugs and chloramine-T in alkaline medium producing red color products with absorbance maximum at the λ=535 and 525 nm for the tetracycline and doxycycline, respectively. The best conditions for the reactions have been found using multivariate method. Beer's law is obeyed in a concentration ranges 1. 03 x 10 -5 to 3. 61 x 10 4mol L -1 and 1. 75 x 10 -5 to 3. 48 x 10 4mol L -1 for the tetracycline and doxycycline, respectively. The quantification limits were 5. 63 x 10 -6 mol L -1 and 7. 12 x 10 -7 mol L -1 for the tetracycline and doxycycline, respectively. The proposed method was successfully applied to the determination of these drugs in pharmaceutical formulations and the results obtained were in good agreement with those obtained by the comparative method at the 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A poly glutamic acid film modified electrode exhibited a catalytic response toguanosine oxidation potential and higher peak current value. Linear concentration curve was obtained in the concentration interval of 1.0 a 10.0 μmol L-1 in 0.04 mol L-1 B-R buffer pH 2.0 with a detection limit of 0.198 μmol L-1. The electrode was used for the determination of guanosine in the potential of +1.1 V (vs. Ag/AgCl) using differential pulse voltammetry (DPV) at urine sample with good recovery. © 2010 by CEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We developed and optimized a simple, efficient and inexpensive method for in vitro culture of peripheral blood lymphocytes from the Brazilian tortoise Chelonoidis carbonaria (Testudinidae), testing various parameters, including culture medium, mitogen concentration, mitotic index, culture volume, incubation time, and mitotic arrest. Peripheral blood samples were obtained from the costal vein of four couples. The conditions that gave a good mitotic index were lymphocytes cultured at 37°C in minimum essential medium (7.5 mL), with phytohemagglutinin as a mitogen (0.375 mL), plus streptomycin/penicillin (0.1 mL), and an incubation period of 72 h. Mitotic arrest was induced by 2-h exposure to colchicine (0.1 mL), 70 h after establishing the culture. After mitotic arrest, the cells were hypotonized with 0.075 M KCl for 2 h and fixed with methanol/acetic acid (3:1). The non-banded mitotic chromosomes were visualized by Giemsa staining. The diploid chromosome number of C. carbonaria was found to be 52 in females and males, and sex chromosomes were not observed. We were able to culture peripheral blood lymphocytes of a Brazilian tortoise in vitro, for the preparation of mitotic chromosomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple method to determine Cu, Fe, Mn and Zn in single aliquots of medicinal plants by HR-CS FAAS is proposed. The main lines for Cu, Mn and Zn, and the alternate line measured at the wing of the main line for Fe at 248.327 nm allowed calibration within the 0.025 - 2.0 mg L-1 Cu, 1.0 - 20.0 mg L-1 Fe, 0.05 - 2.0 mg L-1 Mn, 0.025 - 0.75 mg L-1 Zn ranges. Nineteen medicinal plants and two certified plant reference materials were analyzed. Results were in agreement at a 95% confidence level (paired t-test) with reference values. Limits of detection were 0.12 μg L-1 Cu, 330 μg L-1 Fe, 1.42 μg L-1 Mn and 8.12 μg L-1 Zn. Relative standard deviations (n=12) were ≤ 3% for all analytes. Recoveries in the 89 - 105% (Cu), 95 - 108% (Fe), 94 - 107% (Mn), and 93 - 110% (Zn) ranges were obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a simple, environmentally friendly and rapid quantitative spot test procedure for the determination of captopril (CPT) in bulk drug and in pharmaceutical formulations by using diffuse reflectance spectroscopy. The proposed method is based on the reflectance measurements of the orange compound (λ max 490 nm) produced by the spot test reaction between CPT and p-chloranil (CL). Under optimal conditions, calibration curves were obtained for CPT by plotting the optical density of the reflectance signal (A R) vs. the log of the mol L -1 concentration, from 6.91×10 -3 to 1.17×10 -1, with a good coefficient of determination (R 2 = 0.9992). The common excipients used as additives in pharmaceuticals do not interfere in the proposed method. The method was applied to determine CPT in commercial pharmaceutical formulations. The results obtained by the proposed method are compared favorably with those obtained by an official procedure at 95% confidence level. The method validation results showed that the sensitivity and selectivity of the methods were adequated for drug monitoring in industrial quality control laboratories. © 2011 Moment Publication.