1000 resultados para Plane extraction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fast and accurate analysis and synthesis technique for high-gain sub-wavelength 2-D Fabry-Perot leaky-wave antennas (LWA) consisting of two periodic metallodielectric arrays over a ground plane is presented. Full-wave method of moments (MoM) together with reciprocity is employed for the estimation of the near fields upon plane wave illumination and the extraction of the radiation patterns of the LWA. This yields a fast and rigorous tool for the characterisation of this type of antennas. A thorough convergence study for different antenna designs is presented and the operation principles of these antennas as well as the radiation characteristics are discussed. Moreover, design guidelines to tailor the antenna profile, the dimensions of the arrays as well as the antenna directivity and bandwidth are provided. A study on the radiation efficiency for antennas with different profiles is also presented and the trade off between directivity and radiation bandwidth is discussed. Numerical examples are given throughout to demonstrate the technique. A finite size antenna model is simulated using commercial software (CST Microstripes 2009) which validates the technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new stir bar sorptive extraction (SBSE) technique coupled with HPLC-UV method for quantification of diclofenac in pharmaceutical formulations has been developed and validated as a proof of concept study. Commercially available polydimethylsiloxane stir bars (Twister (TM)) were used for method development and SBSE extraction (pH, phase ratio, stirring speed, temperature, ionic strength and time) and liquid desorption (solvents, desorption method, stirring time etc) procedures were optimised. The method was validated as per ICH guidelines and was successfully applied for the estimation of diclofenac from three liquid formulations viz. Voltarol (R) Optha single dose eye drops, Voltarol (R) Ophtha multidose eye drops and Voltarol (R) ampoules. The developed method was found to be linear (r=0.9999) over 100-2000 ng/ml concentration range with acceptable accuracy and precision (tested over three QC concentrations). The SBSE extraction recovery of the diclofenac was found to be 70% and the LOD and LOQ of the validated method were found to be 16.06 and 48.68 ng/ml, respectively. Furthermore, a forced degradation study of a diclofenac formulation leading to the formation of structurally similar cyclic impurity (indolinone) was carried out. The developed extraction method showed comparable results to that of the reference method, i.e. method was capable of selectively extracting the indolinone and diclofenac from the liquid matrix. Data on inter and intra stir bar accuracy and precision further confirmed robustness of the method, supporting the multiple re-use of the stir bars. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quality factor of microwave resonators miniaturised by virtue of periodic loading is assessed. Five X-band resonators in E-plane technology with different miniaturisation factors have been designed to resonate at approximately the same frequency. The loaded quality factor is extracted from the fractional bandwidth and subsequently employed to estimate the unloaded quality factor. The study reveals that the unloaded quality factor drops approximately linearly with the miniaturisation. Subsequently design guidelines for E-plane filters with periodically loaded resonators are provided by means of an example involving a fifth-order filter. Full-wave simulated and experimental results are presented to validate the study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some thermodynamical properties of solids, such as heat capacity and magnetic susceptibility, have recently been shown to be linked to the amount of entanglement in a solid. However, this entanglement may appear a mere mathematical artefact of the typical symmetrization procedure of many-body wavefunction in solid state physics. Here we show that this entanglement is physical, demonstrating the principles of its extraction from a typical solid-state system by scattering two particles off the system. Moreover, we show how to simulate this process using present day optical lattice technology. This demonstrates not only that entanglement exists in solids but also that it can be used for quantum information processing or as a test of Bell's inequalities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measuring neuropeptides in biological tissues by radioimmunoassay requires efficient extraction that maintains their immunoreactivity. Many different methods for extraction have been described, but there is little information on optimal extraction methods for individual neuropeptides from human dental pulp tissue. The aim was therefore to identify an effective extraction procedure for three pulpal neuropeptides: substance P. neurokinin A and calcitonin gene-related peptide. Tissue was obtained from 20 pulps taken from teeth freshly extracted for orthodontic reasons. The pulp samples were divided into four equal groups and different extraction methods were used for each group. Boiling whole pulp in acetic acid gave the highest overall yield and, in addition, offered an easy and rapid means of pulp tissue processing. The use of protease inhibitors did not increase the recovery of the immunoreactive neuropeptides but did provide the best combination of maximal recoveries and minimal variability. These results should be useful for planning the extraction of these neuropeptides from human pulp tissue in future studies. (C) 1999 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of four calix[5]arenes and three calix[6]arenes (R-calixarene-OCH2COR1) (R = H or Bu-t) with alkyl ketone residues (R-1 = Me or Bu-t) on the lower rim have been synthesized, and their affinity for complexation of alkali cations has been assessed through phase-transfer experiments and stability constant measurements. The conformations of these ketones have been probed by H-1 NMR and X-ray diffraction analysis, and by molecular mechanics calculations. Pentamer 3 (R R-1 = Bu-t) possesses a symmetrical cone conformation in solution and a very distorted cone conformation in the solid state. Pentamer 5 (R = H, R-1 = Bu-t) exists in a distorted 1,2-alternate conformation in the solid state, but in solution two slowly interconverting conformations, one a cone and the other presumed to be 1,2-alternate, can be detected. X-ray structure analysis of the sodium and rubidium perchlorate complexes of 3 reveal the cations deeply encapsulated by the ethereal and carbonyl oxygen atoms in distorted cone conformations which can be accurately reproduced by molecular mechanics calculations. The phase-transfer and stability constant data reveal that the extent of complexation depends on calixarene size and the nature of the alkyl residues adjacent to the ketonic carbonyls with tert-butyl much more efficacious than methyl.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ionic liquid 1-ethyl-3-methylimidazolium bis{(trifluoromethyl)sulfonyl}amide ([C(2)mim][NTf2]) was tested as solvent for the separation of aromatic and aliphatic hydrocarbons containing 7 or 8 carbon atoms (the C-7- and C-8-fractions). The liquid-liquid equilibria (LLE) of the ternary systems (heptane + toluene + [C(2)mim][NTf2]) and (octane + ethylbenzene + [C(2)mim][NTf2]), at 25 degrees C, were experimentally determined. The performance of the ionic liquid as the solvent in such systems was evaluated by means of the calculation of the solute distribution ratio and the selectivity. The results were compared to those previously reported for the extraction of benzene from its mixtures with hexane by using the same ionic liquid, therefore analysing the influence of the size of the hydrocarbons. It was found that the ionic liquid is also good for the extraction of C-7- and C-8- fraction aromatic compounds, just a greater amount of ionic liquid being needed to perform an equivalently efficient separation than for the C-6-fraction. It is also discussed how [C(2)mim][NTf2] performs comparably better than the conventional solvent sulfolane. The original 'Non-Random Two-Liquid' (NRTL) equation was used to adequately correlate the experimental LLE data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rectangular waveguide-to-microstrip transition operating at G-band is presented. The E-plane probe, used in the transition, is fabricated on semi-insulating gallium arsenide (SI-GaAs) and it is elevated on the substrate. This configuration reduces interaction with semiconductor material. The elevated probe is suitable for direct integration with monolithic microwave integrated circuits. Measured results show S11 better than 210dB between 150 and 200 GHz and S21 ¼ 2 4dB at centre band (180GHz) for two transitions in back-to-back configuration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study the extraction of paralytic shellfish poisoning (PSP) toxins from a toxic strain of the marine dinoflagellate Alexandrium tamarense CCMP-1493 using various mechanical and/or physical procedures was investigated. PBS buffer was investigated as the extraction solvent in order for these procedures to be used directly with immuno-magnetic Ferrospheres-N. The extraction was performed following the determination of when toxin content by the algae was at its highest during batch culture. The methods used for cell lysis and toxin extraction included freeze-thawing, freeze-boiling, steel ball bearing beating, glass bead beating, and sonication. The steel ball bearing beating was determined to release a similar amount of toxin when compared to a modified standard extraction method which was reported to release 100% of toxins from the algal cells and was therefore used in the next phase of the study. This next phase was to determine the feasibility of utilising an antibody coupled to novel magnetic microspheres (Ferrospheres-N) as a simple, rapid immune-capture procedure for PSP toxins extracted from the algae. The effects of increasing mass of Ferrospheres-N on the immuno-capture of the PSP toxins from the toxic algal strain extracts were investigated. Toxin recovery was found to increase when an increasing mass of Ferrospheres-N was used until 96.2% (+/- 1.3 SD) of the toxin extracted from the cells was captured and eluted. Toxin recovery was determined by comparison to an appropriate PSP toxin standard curve following analysis by the AOAC HPLC method. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The capillary micro reactor, with four stable operating flow patterns and a throughput range from grams per hour to kilograms per hour, presents an attractive alternative to chip-based and microstructured reactors for laboratory- and pilot-scale applications. In this article, results for the extraction of 2-butanol from toluene under different flow patterns in a water/toluene flow in long capillary microreactors are presented. The effects of the capillary length (0.4-2.2 m), flow rate (0.1-12 mL/min), and aqueous-to-organic volumetric flow ratio (0.25-9) on the slug, bubbly, parallel, and annular flow hydrodynamics were investigated. Weber-number-dependent flow maps were composed for capillary lengths of 0.4 and 2 m that were used to interpret the flow pattern formation in terms of surface tension and inertia forces. When the capillary length was decreased from 2 to 0.4 m, a transition from annular to parallel flow was observed. The capillary length had little influence on slug and bubbly flows. The flow patterns were evaluated in terms of stability, surface-to-volume ratio, throughput, and extraction efficiency. Slug and bubbly flow operations yielded 100% thermodynamic extraction efficiency, and increasing the aqueous-to-organic volumetric ratio to 9 allowed for 99% 2-butanol extraction. The parallel and annular flow operating windows were limited by the capillary length, thus yielding maximum 2-butanol extractions of 30% and 47% for parallel and annular flows, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A surface plasmon resonance (SPR) biosensor screening assay was developed and validated to detect 11 benzimidazole carbamate (BZT) veterinary drug residues in milk. The polyclonal antibody used was raised in sheep against a methyl 5(6)-[(carboxypentyl)-thio]-2-benzimidazole carbamate protein conjugate. A sample preparation procedure was developed using a modified QuEChERS method. BZT residues were extracted from milk using liquid extraction/partition with a dispersive solid phase extraction clean-up step. The assay was validated in accordance with the performance criteria described in 2002/657/EC. The limit of detection of the assay was calculated from the analysis of 20 known negative milk samples to be 2.7 mu g kg(-1). The detection capability (CC beta) of the assay was determined to be 5 mu g kg(-1) for 11 benzimidazole residues and the mean recovery of analytes was in the range 81-116%. A comparison was made between the SPR-biosensor and UPLC-MS/MS analyses of milk samples (n = 26) taken from cows treated different benzimidazole products, demonstrating the SPR-biosensor assay to be fit for purpose. (C) 2009 Elsevier B.V. All rights reserved.