862 resultados para Physician-Assisted Suicide
Resumo:
Homicide followed by the suicide of the offender is a well-known phenomenon. In most cases, it takes place in the context of the so-called "family tragedies." A recent series of such family tragedies in Switzerland prompted an intensive debate in the media and the Swiss government concerning the Swiss Weapon Law, in particular the requirement to keep personal army weapons at home. The present study of Homicide-Suicide cases in Switzerland, thus focuses on the role played by guns, especially military weapons, in such crimes. We investigated retrospectively 75 cases of Homicide-Suicide, comprising 172 individuals and spanning a period of 23 years in western and central Switzerland. Our results show that if guns were used in 76% of the cases, army weapons were the cause of death in 25% of the total. In 28% of the deaths caused by a gunshot, the exact type of the gun and its origin could not be determined. Thus, the majority of Homicide-Suicide cases in Switzerland involve the use of guns. The exact percentage of cases were military weapons were involved could not be defined. In our opinion, a stricter weapons law, restricting access to firearms, would be a factor of prevention of Homicide- Suicide cases in Switzerland.
Resumo:
The literature contains many case reports of planned and complex suicides, which combine various methods to commit suicide. In this article, we present the anomalous suicide of an adult male by strangulation with a belt and simultaneous ingestion of plaster. The specific circumstances of the case are described and relevant literature is briefly reviewed. This case vignette illustrates one example of the wide ranging methods employed in suicides and may represent the first reported case of a fatal complex suicide involving self-strangulation and plaster ingestion. Knowledge of varied and sometimes unusual suicide methods is important to the forensic investigator to prevent unnecessary criminal investigation and to reliably and confidently establish manner and cause of death.
Resumo:
Heavy alcohol consumption may accelerate the progression of hepatitis C-related liver disease and/or limit efforts at antiviral treatment in opioid-dependent patients receiving heroin-assisted treatment (HAT). Our study aims to assess alcohol intake among HAT patients by self-reports compared to direct ethanol metabolites.
Resumo:
Background Patients often establish initial contact with healthcare institutions by telephone. During this process they are frequently medically triaged. Purpose To investigate the safety of computer-assisted telephone triage for walk-in patients with non-life-threatening medical conditions at an emergency unit of a Swiss university hospital. Methods This prospective surveillance study compared the urgency assessments of three different types of personnel (call centre nurses, hospital physicians, primary care physicians) who were involved in the patients' care process. Based on the urgency recommendations of the hospital and primary care physicians, cases which could potentially have resulted in an avoidable hazardous situation (AHS) were identified. Subsequently, the records of patients with a potential AHS were assessed for risk to health or life by an expert panel. Results 208 patients were enrolled in the study, of whom 153 were assessed by all three types of personnel. Congruence between the three assessments was low. The weighted κ values were 0.115 (95% CI 0.038 to 0.192) (hospital physicians vs call centre), 0.159 (95% CI 0.073 to 0.242) (primary care physicians vs call centre) and 0.377 (95% CI 0.279 to 0.480) (hospital vs primary care physicians). Seven of 153 cases (4.57%; 95% CI 1.85% to 9.20%) were classified as a potentially AHS. A risk to health or life was adjudged in one case (0.65%; 95% CI 0.02% to 3.58%). Conclusion Medical telephone counselling is a demanding task requiring competent specialists with dedicated training in communication supported by suitable computer technology. Provided these conditions are in place, computer-assisted telephone triage can be considered to be a safe method of assessing the potential clinical risks of patients' medical conditions.
Resumo:
An algorithm for the real-time registration of a retinal video sequence captured with a scanning digital ophthalmoscope (SDO) to a retinal composite image is presented. This method is designed for a computer-assisted retinal laser photocoagulation system to compensate for retinal motion and hence enhance the accuracy, speed, and patient safety of retinal laser treatments. The procedure combines intensity and feature-based registration techniques. For the registration of an individual frame, the translational frame-to-frame motion between preceding and current frame is detected by normalized cross correlation. Next, vessel points on the current video frame are identified and an initial transformation estimate is constructed from the calculated translation vector and the quadratic registration matrix of the previous frame. The vessel points are then iteratively matched to the segmented vessel centerline of the composite image to refine the initial transformation and register the video frame to the composite image. Criteria for image quality and algorithm convergence are introduced, which assess the exclusion of single frames from the registration process and enable a loss of tracking signal if necessary. The algorithm was successfully applied to ten different video sequences recorded from patients. It revealed an average accuracy of 2.47 ± 2.0 pixels (∼23.2 ± 18.8 μm) for 2764 evaluated video frames and demonstrated that it meets the clinical requirements.
Resumo:
We have developed a haptic-based approach for retraining of interjoint coordination following stroke called time-independent functional training (TIFT) and implemented this mode in the ARMin III robotic exoskeleton. The ARMin III robot was developed by Drs. Robert Riener and Tobias Nef at the Swiss Federal Institute of Technology Zurich (Eidgenossische Technische Hochschule Zurich, or ETH Zurich), in Zurich, Switzerland. In the TIFT mode, the robot maintains arm movements within the proper kinematic trajectory via haptic walls at each joint. These arm movements focus training of interjoint coordination with highly intuitive real-time feedback of performance; arm movements advance within the trajectory only if their movement coordination is correct. In initial testing, 37 nondisabled subjects received a single session of learning of a complex pattern. Subjects were randomized to TIFT or visual demonstration or moved along with the robot as it moved though the pattern (time-dependent [TD] training). We examined visual demonstration to separate the effects of action observation on motor learning from the effects of the two haptic guidance methods. During these training trials, TIFT subjects reduced error and interaction forces between the robot and arm, while TD subject performance did not change. All groups showed significant learning of the trajectory during unassisted recall trials, but we observed no difference in learning between groups, possibly because this learning task is dominated by vision. Further testing in stroke populations is warranted.
Resumo:
In this paper we propose a new system that allows reliable acetabular cup placement when the THA is operated in lateral approach. Conceptually it combines the accuracy of computer-generated patient-specific morphology information with an easy-to-use mechanical guide, which effectively uses natural gravity as the angular reference. The former is achieved by using a statistical shape model-based 2D-3D reconstruction technique that can generate a scaled, patient-specific 3D shape model of the pelvis from a single conventional anteroposterior (AP) pelvic X-ray radiograph. The reconstructed 3D shape model facilitates a reliable and accurate co-registration of the mechanical guide with the patient’s anatomy in the operating theater. We validated the accuracy of our system by conducting experiments on placing seven cups to four pelvises with different morphologies. Taking the measurements from an image-free navigation system as the ground truth, our system showed an average accuracy of 2.1 ±0.7 o for inclination and an average accuracy of 1.2 ±1.4 o for anteversion.
Resumo:
Laser tissue soldering (LTS) is a promising technique for tissue fusion but is limited by the lack of reproducibility particularly when the amount of indocyanine green (ICG) applied as energy absorber cannot be controlled during the soldering procedure. Nanotechnology enables the control over the quantitative binding of the ICG. The aim of this study was to establish a highly reproducible and strong tissue fusion using ICG packed nanoshells. By including the chromophore in the soldering scaffold, dilution of the energy absorber during the soldering procedure is prevented. The feasibility of this novel nanoshell soldering technique was studied by assessing the local heating of the area and tensile strength of the resulting fused tissue.
Resumo:
Posterior lumbar fusion is a frequently performed procedure in spinal surgery. High percentages of good and excellent results are indicated by physicians. On the other hand patient-based outcomes are reported. Little is known about the correlations of these two assessment types. We aimed at their comparison. The analysis included 1013 patients with degenerative spinal disease or spondylolisthesis from an international spine registry, treated with posterior lumbar fusion. All patients were pre/postop assessed by physician-based McNab criteria (‘excellent’, ‘good’, ‘fair’, ‘poor’). Of these patients, 210 (mean age 61 years; 57% females) were in addition assessed by patient-based Oswestry Disability Index (ODI). The remaining 803 patients (mean age 59 years; 56% females) were assessed by patient-based Core Outcome Measure Index (COMI), including Visual Analogue Scale (VAS) for back and leg pain as well as verbal self-rating (‘helped a lot’, ‘helped’, ‘helped only little’, ‘didn’t help’, ‘made things worse’). McNab criteria were compared to the Minimal Clinically Important Difference (MCID) in ODI (12.8), in VAS back (1.2) and leg pain (1.6). We investigated the correlations between McNab criteria and these patient-based outcomes. In the ‘excellent’ group as rated by physicians, the proposed MCID was reached in 83% of patients for ODI, in 69% for VAS back and in 83% for VAS leg pain. All patients said the treatment had ‘helped’ or ‘helped a lot’. In the ‘good’ group 56% (ODI), 66% (back pain) and 86% (leg pain) reached the MCID. 96% of patients perceived the treatment as positive. In the ‘fair’ group 37% (ODI), 55% (back pain) and 63% (leg pain) reached the MCID. 49% had positive treatment considerations. The ‘poor’ group revealed 30% (ODI), 35% (back pain) and 44% (leg pain) of patients with reached MCID. Only 15% rated the treatment as positive. The Spearman correlation coefficients between McNab criteria on the one hand and ODI, back and leg pain as well as patients’ verbal self-rating on the other hand were 0.57, 0.37, 0.36 and 0.46 respectively. The comparison of physician and patient-based outcomes showed the highest correlations between McNab criteria and ODI, somewhat weaker correlations with patients’ self-rating and the weakest correlations with back and leg pain. Based on these findings, physicians’ evaluation of patient outcomes can be considered a valuable part of patient assessment, corresponding very well with patients’ perceptions of success or failure of spinal surgery.
Resumo:
Percutaneous needle intervention based on PET/CT images is effective, but exposes the patient to unnecessary radiation due to the increased number of CT scans required. Computer assisted intervention can reduce the number of scans, but requires handling, matching and visualization of two different datasets. While one dataset is used for target definition according to metabolism, the other is used for instrument guidance according to anatomical structures. No navigation systems capable of handling such data and performing PET/CT image-based procedures while following clinically approved protocols for oncologic percutaneous interventions are available. The need for such systems is emphasized in scenarios where the target can be located in different types of tissue such as bone and soft tissue. These two tissues require different clinical protocols for puncturing and may therefore give rise to different problems during the navigated intervention. Studies comparing the performance of navigated needle interventions targeting lesions located in these two types of tissue are not often found in the literature. Hence, this paper presents an optical navigation system for percutaneous needle interventions based on PET/CT images. The system provides viewers for guiding the physician to the target with real-time visualization of PET/CT datasets, and is able to handle targets located in both bone and soft tissue. The navigation system and the required clinical workflow were designed taking into consideration clinical protocols and requirements, and the system is thus operable by a single person, even during transition to the sterile phase. Both the system and the workflow were evaluated in an initial set of experiments simulating 41 lesions (23 located in bone tissue and 18 in soft tissue) in swine cadavers. We also measured and decomposed the overall system error into distinct error sources, which allowed for the identification of particularities involved in the process as well as highlighting the differences between bone and soft tissue punctures. An overall average error of 4.23 mm and 3.07 mm for bone and soft tissue punctures, respectively, demonstrated the feasibility of using this system for such interventions. The proposed system workflow was shown to be effective in separating the preparation from the sterile phase, as well as in keeping the system manageable by a single operator. Among the distinct sources of error, the user error based on the system accuracy (defined as the distance from the planned target to the actual needle tip) appeared to be the most significant. Bone punctures showed higher user error, whereas soft tissue punctures showed higher tissue deformation error.
Resumo:
The synthesis of cyclic polystyrene (Pst) with an alkoxyamine functionality has been accomplished by intramolecular radical coupling in the presence of a nitroso radical trap Linear alpha,omega-dibrominated polystyrene, produced by the atom transfer radical polymerization (ATRP) of styrene using a dibrominated initiator, was subjected to chain-end activation via the atom transfer radical coupling (ATRC) process under pseudodilute conditions in the presence of 2-methyl-2-nitrosopropane (MNP). This radical trap-assisted, intramolecular ATRC (RTA-ATRC) produced cyclic polymers in greater than 90% yields possessing < G > values in the 0.8-0.9 range as determined by gel permeation chromatography (GPC). Thermal-induced opening of the cycles, made possible by the incorporated alkoxyamine, resulted in a return to the original apparent molecular weight, further supporting the formation of cyclic polymers in the RTA-ATRC reaction. Liquid chromatography-mass spectrometry (LC-MS) provided direct confirmation of the cyclic architecture and the incorporation of the nitroso group into the macrocycle RTA-ATRC cyclizations carried out with faster rates of polymer addition into the redox active solution and/or in the presence of a much larger excess of MNP (up to a 250:1 ratio of MNP:C-Br chain end) still yielded cyclic polymers that contained alkoxyamine functionality.
Resumo:
To provide insight into the recently published cost comparisons in the context of open, laparoscopic, and robotic-assisted laparoscopic radical cystectomy and to demonstrate the complexity of such economic analyses.
Resumo:
Monobrominated polystyrene (PStBr) chains were prepared using standard atom transfer radical polymerization (ATRP) procedures at 80 °C in THF, with monomer conversions allowed to proceed to approximately 40%. At this time, additional copper catalyst, reducing agent, and ligand were added to the unpurified reaction mixture, and the reaction was allowed to proceed at 50 °C in an atom transfer radical coupling (ATRC) phase. During this phase, polymerization continued to occur as well as coupling; expected due to the substantial amount of residual monomer remaining. This was confirmed using gel permeation chromatography (GPC), which showed increases in molecular weight not matching a simple doubling of the PStBr formed during ATRP, and an increase in monomer conversion after the second phase. When the radical trap 2-methyl-2-nitrosopropane (MNP) was added to the ATRC phase, no further monomer conversion occurred and the resulting product showed a doubling of peak molecular weight (Mp), consistent with a radical trap-assisted ATRC (RTA-ATRC) reaction.