893 resultados para Performance Evaluation of Pavements


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The topic of bioenergy, biofuels and bioproducts remains at the top of the current political and research agenda. Identification of the optimum processing routes for biomass, in terms of efficiency, cost, environment and socio-economics is vital as concern grows over the remaining fossil fuel resources, climate change and energy security. It is known that the only renewable way of producing conventional hydrocarbon fuels and organic chemicals is from biomass, but the problem remains of identifying the best product mix and the most efficient way of processing biomass to products. The aim is to move Europe towards a biobased economy and it is widely accepted that biorefineries are key to this development. A methodology was required for the generation and evaluation of biorefinery process chains for converting biomass into one or more valuable products that properly considers performance, cost, environment, socio-economics and other factors that influence the commercial viability of a process. In this thesis a methodology to achieve this objective is described. The completed methodology includes process chain generation, process modelling and subsequent analysis and comparison of results in order to evaluate alternative process routes. A modular structure was chosen to allow greater flexibility and allowing the user to generate a large number of different biorefinery configurations The significance of the approach is that the methodology is defined and is thus rigorous and consistent and may be readily re-examined if circumstances change. There was the requirement for consistency in structure and use, particularly for multiple analyses. It was important that analyses could be quickly and easily carried out to consider, for example, different scales, configurations and product portfolios and so that previous outcomes could be readily reconsidered. The result of the completed methodology is the identification of the most promising biorefinery chains from those considered as part of the European Biosynergy Project.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To compare distance and near visual performance with a zero-aberration aspheric intraocular lens (IOL) (Softec HD, Lenstec, Inc. FL, USA) with that of an otherwise identical, but spherical IOL (Softec 1). Setting: Department of Ophthalmology, Solihull Hospital, West Midlands, United Kingdom. Methods: This prospective study comprised 37 patients with a Softec 1 spherical IOL implanted in one eye, who underwent phacoemulsification and received the Softec HD aspheric IOL in the fellow eye. One month post-operatively, unaided distance and near vision, residual refraction, best spectacle corrected distance and near visual acuity, reading speed, pseudoaccommodation and photopic contrast sensitivity were recorded. Wavefront analysis enabled comparison of higher order aberrations between the IOLs. Results: Prior to surgery, the Softec 1 and Softec HD eyes were not significantly different. Post-operatively, unaided vision, best spectacle corrected visual acuity and residual refraction were not significantly different between the eyes, nor were there significant differences observed between the measured wavefront aberrations. Once implanted, the range of focus was significantly better in the Softec HD IOL eye than the Softec 1 IOL eye and, although reading speed was equivalent to the Softec 1 eye, the print size at which this could be achieved was significantly smaller. Conclusions: Depth of field was significantly improved with the aspheric IOL compared with the spherical IOL, without any compromise in distance visual performance between the two IOLs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There has been substantial research into the role of distance learning in education. Despite the rise in the popularity and practice of this form of learning in business, there has not been a parallel increase in the amount of research carried out in this field. An extensive investigation was conducted into the entire distance learning system of a multi-national company with particular emphasis on the design, implementation and evaluation of the materials. In addition, the performance and attitudes of trainees were examined. The results of a comparative study indicated that trainees using distance learning had significantly higher test scores than trainees using conventional face-to-face training. The influence of the previous distance learning experience, educational background and selected study environment of trainees was investigated. Trainees with previous experience of distance learning were more likely to complete the course and with significantly higher test scores than trainees with no previous experience. The more advanced the educational background of trainees, the greater the likelihood of their completing the course, although there was no significant difference in the test scores achieved. Trainees preferred to use the materials at home and those opting to study in this environment scored significantly higher than those studying in the office, the study room at work or in a combination of environments. The influence of learning styles (Kolb, 1976) was tested. The results indicated that the convergers had the greatest completion rates and scored significantly higher than trainees with the assimilator, accommodator and diverger learning styles. The attitudes of the trainees, supervisors and trainers were examined using questionnaire, interview and discussion techniques. The findings highlighted the potential problems of lack of awareness and low motivation which could prove to be major obstacles to the success of distance learning in business.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this thesis the validity of an Assessment Centre (called 'Extended Interview') operated on behalf of the British police is investigated. This Assessment Centre (AC) is used to select from amongst internal candidates (serving policemen and policewomen) and external candidates (graduates) for places on an accelerated promotion scheme. The literature is reviewed with respect to history, content, structure, reliability, validity, efficiency and usefulness of ACs, and to contextual issues surrounding AC use. The history of, background to and content of police Extended Interviews (Els) is described, and research issues are identified. Internal validation involved regression of overall EI grades on measures from component tests, exercises, interviews and peer nominations. Four samples numbering 126, 73, 86 and 109 were used in this part of the research. External validation involved regression of three types of criteria - training grades, rank attained, and supervisory ratings - on all EI measures. Follow-up periods for job criteria ranged from 7 to 19 years. Three samples, numbering 223, 157 and 86, were used in this part of the research. In subsidiary investigations, supervisory ratings were factor analysed and criteria intercorrelated. For two of the samples involved in the external validition, clinical/judgemental prediction was compared with mechanical (unit-weighted composite) prediction. Main conclusions are that: (1) EI selection decisions were valid, but only for a job performance criterion; relatively low validity overall was interpreted principally in terms of the questionable job relatedness of the EI procedure; (2) Els as a whole had more validity than was reflected in final EI decisions; (3) assessors' use of information was not optimum, tending to over-emphasize subjectively derived information particularly from interviews; and (4) mechanical prediction was superior to clinical/judgemental prediction for five major criteria.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present thesis evaluates various aspects of videokeratoscopes, which are now becoming increasingly popular in the investigation of corneal topography. The accuracy and repeatability of these instruments has been assessed mainly using spherical surfaces, however, few studies have assessed the performance of videokeratoscopes in measuring convex aspheric surfaces. Using two videokeratoscopes, the accuracy and repeatability of measurements using twelve aspheric surfaces is determined. Overall, the accuracy and repeatability of both instruments were acceptable, however, progressively flatter surfaces introduced greater errors in measurement. The possible reasons for these errors are discussed. The corneal surface is a biological structure lubricated by the precorneal tear film. The effects of variations in the tear film on the repeatability of videokeratoscopes have not been determined in terms of peripheral corneal measurements. The repeatability of two commercially available videokeratoscopes is assessed. The repeatability is found to be dependent on the point of measurement on the corneal surface. Typically, superior and nasal meridians exhibit poorest repeatability. It is suggested that interference of the ocular adnexa is responsible for the reduced repeatability. This localised reduction in repeatability will occur for all videokeratoscopes. Further, comparison with the keratometers and videokeratoscopes used show that measurements between these instruments are not interchangeable. The final stage of this thesis evaluates the performance of new algorithms. The characteristics of a new videokeratoscope are described. This videokeratoscope is used to test the accuracy of the new algorithms for twelve aspheric surfaces. The new algorithms are accurate in determining the shape of aspheric surfaces, more so than those algorithms proposed at present.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The specific objective of the research was to evaluate proprietary audit systems. Proprietary audit systems comprise question sets containing approximately 500 questions dealing with selected aspects of health and safety management. Each question is allotted a number of points and an organisation seeks to judge its health and safety performance by the overall score achieved in the audit. Initially it was considered that the evaluation method might involve comparing the proprietary audit scores with other methods of measuring safety performance. However, what appeared to be missing in the first instance was information that organisations could use to compare the contrast question set content against their own needs. A technique was developed using the computer database FileMaker Pro. This enables questions in an audit to be sorted into categories using a process of searching for key words. Questions that are not categorised by word searching can be identified and sorted manually. The process can be completed in 2-3 hours which is considerably faster than manual categorisation of questions which typically takes about 10 days. The technique was used to compare and contrast three proprietary audits: ISRS, CHASE and QSA. Differences and similarities between these audits were successfully identified. It was concluded that in general proprietary audits need to focus to a greater extent on identifying strengths and weaknesses in occupational health and safety management systems. To do this requires the inclusion of more probing questions which consider whether risk control measures are likely to be successful.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To exploit the popularity of TCP as still the dominant sender and protocol of choice for transporting data reliably across the heterogeneous Internet, this thesis explores end-to-end performance issues and behaviours of TCP senders when transferring data to wireless end-users. The theme throughout is on end-users located specifically within 802.11 WLANs at the edges of the Internet, a largely untapped area of work. To exploit the interests of researchers wanting to study the performance of TCP accurately over heterogeneous conditions, this thesis proposes a flexible wired-to-wireless experimental testbed that better reflects conditions in the real-world. To exploit the transparent functionalities between TCP in the wired domain and the IEEE 802.11 WLAN protocols, this thesis proposes a more accurate methodology for gauging the transmission and error characteristics of real-world 802.11 WLANs. It also aims to correlate any findings with the functionality of fixed TCP senders. To exploit the popularity of Linux as a popular operating system for many of the Internet’s data servers, this thesis studies and evaluates various sender-side TCP congestion control implementations within the recent Linux v2.6. A selection of the implementations are put under systematic testing using real-world wired-to-wireless conditions in order to screen and present a viable candidate/s for further development and usage in the modern-day heterogeneous Internet. Overall, this thesis comprises a set of systematic evaluations of TCP senders over 802.11 WLANs, incorporating measurements in the form of simulations, emulations, and through the use of a real-world-like experimental testbed. The goal of the work is to ensure that all aspects concerned are comprehensively investigated in order to establish rules that can help to decide under which circumstances the deployment of TCP is optimal i.e. a set of paradigms for advancing the state-of-the-art in data transport across the Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purine and pyrimidine triplex-forming oligonucleotides (TFOs), as potential antibacterial agents, were designed to bind by Hoogsteen and reverse Hoogsteen hydrogen bonds in a sequence specific manner in the major groove of genomic DNA at specific polypurine sites within the gyrA gene of E. coli and S. pneumoniae. Sequences were prepared by automated synthesis, with purification and characterisation determined by high performance liquid chromatograpy, capillary electrophoresis and mass spectrometry. Triplex stability was assessed using melting curves where the binding of the third strand to the duplex target, was assessed over a temperature range of 0-80°C, and at pH 6.4 and 7.2. The most successful of the unmodified TFOs (6) showed a Tm value of 26 °C at both pH values with binding via reverse Hoogsteen bonds. Binding to genomic DNA was also demonstrated by spectrofluorimetry, using fluorescein-labelled TFOs, from which dissociation constants were determined. Modifications in the form of 5mC, 5' acridine attachment, phosphorothioation, 2'-0-methylation and phosphoramidation, were made in order to. increase Tm values. Phosphoramidate modification was the most with increased Tm values of 42°C. However, the final purity of these sequences was poor due to their difficult syntheses. FACS (fluorescent activated cell sorting) analysis was used to determine the potential uptake of a fluorescently labelled analogue of 6 via passive, coJd shock mediated, and anionic liposome aided, uptake. This was established at 20°C and 37°C. At both temperatures anionic lipid-mediated uptake produced unrivalled fluorescence, equivalent to 20 and 43% at 20 and 37°C respectively. Antibacterial activity of each oligonucleotide was assessed by viable count anaJysis relying on passive uptake, cold shocking techniques, chlorpromazine-mediated uptake, and, cationic and anionic lipid-aided uptake. All oligonucleotides were assessed for their ability to enhance uptake, which is a major barrier to the effectiveness of these agents. Compound 6 under cold shocking conditions produced the greatest consistent decline in colony forming units per ml. Results for this compound were sometimes variable indicating inconsistent uptake by this particular assay method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

WiMAX has been introduced as a competitive alternative for metropolitan broadband wireless access technologies. It is connection oriented and it can provide very high data rates, large service coverage, and flexible quality of services (QoS). Due to the large number of connections and flexible QoS supported by WiMAX, the uplink access in WiMAX networks is very challenging since the medium access control (MAC) protocol must efficiently manage the bandwidth and related channel allocations. In this paper, we propose and investigate a cost-effective WiMAX bandwidth management scheme, named the WiMAX partial sharing scheme (WPSS), in order to provide good QoS while achieving better bandwidth utilization and network throughput. The proposed bandwidth management scheme is compared with a simple but inefficient scheme, named the WiMAX complete sharing scheme (WCPS). A maximum entropy (ME) based analytical model (MEAM) is proposed for the performance evaluation of the two bandwidth management schemes. The reason for using MEAM for the performance evaluation is that MEAM can efficiently model a large-scale system in which the number of stations or connections is generally very high, while the traditional simulation and analytical (e.g., Markov models) approaches cannot perform well due to the high computation complexity. We model the bandwidth management scheme as a queuing network model (QNM) that consists of interacting multiclass queues for different service classes. Closed form expressions for the state and blocking probability distributions are derived for those schemes. Simulation results verify the MEAM numerical results and show that WPSS can significantly improve the network's performance compared to WCPS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis describes research that has developed the principles of a modelling tool for the analytical evaluation of a manufacturing strategy. The appropriate process of manufacturing strategy formulation is based on mental synthesis with formal planning processes supporting this role. Inherent to such processes is a stage where the effects of alternative strategies on the performance of a manufacturing system must be evaluated so that a choice of preferred strategy can be made. Invariably this evaluation is carried out by practitioners applying mechanisms of judgement, bargaining and analysis. Ibis thesis makes a significant and original contribution to the provision of analytical support for practitioners in this role. The research programme commences by defining the requirements of analytical strategy evaluation from the perspective of practitioners. A broad taxonomy of models has been used to identify a set of potentially suitable techniques for the strategy evaluation task. Then, where possible, unsuitable modelling techniques have been identified on the basis of evidence in the literature and discarded from this set. The remaining modelling techniques have been critically appraised by testing representative contemporary modelling tools in an industrially based experimentation programme. The results show that individual modelling techniques exhibit various limitations in the strategy evaluation role, though some combinations do appear to provide the necessary functionality. On the basis of this comprehensive and in-depth knowledge a modelling tool ' has been specifically designed for this task. Further experimental testing has then been conducted to verify the principles of this modelling tool. Ibis research has bridged the fields of manufacturing strategy formulation and manufacturing systems modelling and makes two contributions to knowledge. Firstly, a comprehensive and in-depth platform of knowledge has been established about modelling techniques in manufacturing strategy evaluation. Secondly, the principles of a tool that supports this role have been formed and verified.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Accommodating Intraocular Lenses (IOLs), multifocal IOLs (MIOLs) and toric IOLs are designed to provide a greater level of spectacle independency post cataract surgery. All of these IOLs are reliant on the accurate calculation of intraocular lens power determined through reliable ocular biometry. A standardised defocus area metric and reading performance index metric were devised for the evaluation of the range of focus and the reading ability of subjects implanted with presbyopic correcting IOLs. The range of clear vision after implantation of an MIOL is extended by a second focal point; however, this results in the prevalence of dysphotopsia. A bespoke halometer was designed and validated to assess this photopic phenomenon. There is a lack of standardisation in the methods used for determining IOL orientation and thus rotation. A repeatable, objective method was developed to allow the accurate assessment of IOL rotation, which was used to determine the rotational and positional stability of a closed loop haptic IOL. A new commercially available biometry device was validated for use with subjects prior to cataract surgery. The optical low coherence reflectometry instrument proved to be a valid method for assessing ocular biometry and covered a wider range of ocular parameters in comparison with previous instruments. The advantages of MIOLs were shown to include an extended range of clear vision translating into greater reading ability. However, an increased prevalence of dysphotopsia was shown with a bespoke halometer, which was dependent on the MIOL optic design. Implantation of a single optic accommodating IOL did not improve reading ability but achieved high subjective ratings of near vision. The closed-loop haptic IOL displayed excellent rotational stability in the late period but relatively poor rotational stability in the early period post implantation. The orientation error was compounded by the high frequency of positional misalignment leading to an extensive overall misalignment of the IOL. This thesis demonstrates the functionality of new IOL lens designs and the importance of standardised testing methods, thus providing a greater understanding of the consequences of implanting these IOLs. Consequently, the findings of the thesis will influence future designs of IOLs and testing methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To evaluate the performance of an aspheric diffractive multifocal acrylic intraocular lens (IOL), ZMB00 1-Piece Tecnis. Setting: Five sites across Europe. Methods: Fifty-two patients with cataracts (average age 68.5±10.5 years, 35 female) were bilaterally implanted with the aspheric diffractive multifocal IOL after completing a questionnaire regarding their optical visual symptoms, use of visual correction and their visual satisfaction. The questionnaire was completed again 4-6 months after surgery along with measures of uncorrected and best-corrected distance and near visual acuity, under photopic and mesopic lighting, reading ability, defocus curve testing and ocular examination for adverse events. Results: The residual refractive error was 0.01±0.47D with 56% of eyes within ±0.25D and 97% within ±1.0D. Uncorrected visual acuity was 0.02±0.10logMAR at distance and 0.15±0.30 logMAR at near, only reducing to 0.07±0.10logMAR at distance and 0.21±0.25logMAR at near in mesopic conditions.The defocus curve showed a near addition between 2.5-3.0 D allowing a reading acuity of 0.08±0.13 logMAR, with a range of clear vision <0.3 logMAR of ∼4.0 D. The average reading speed was 121.4±30.8 words per minute. Spectacle independence was 100% for distance and 88% for near, with high levels of satisfaction reported. Overall rating of vision without glasses could be explained (r=0.760) by preoperative best-corrected distance acuity, postoperative reading acuity and postoperative uncorrected distance acuity in photopic conditions (p<0.001). Only two minor adverse events occurred. Conclusions: The ZMB00 1-Piece Tecnis multifocal IOL provides a good visual outcome at distance and near with minimal adverse effects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background - The PELICAN Multidisciplinary Team Total Mesorectal Excision (MDT-TME) Development Programme aimed to improve clinical outcomes for rectal cancer by educating colorectal cancer teams in precision surgery and related aspects of multidisciplinary care. The Programme reached almost all colorectal cancer teams across England. We took the opportunity to assess the impact of participating in this novel team-based Development Programme on the working lives of colorectal cancer team members. Methods - The impact of participating in the programme on team members' self-reported job stress, job satisfaction and team performance was assessed in a pre-post course study. 333/568 (59%) team members, from the 75 multidisciplinary teams who attended the final year of the Programme, completed questionnaires pre-course, and 6-8 weeks post-course. Results - Across all team members, the main sources of job satisfaction related to working in multidisciplinary teams; whilst feeling overloaded was the main source of job stress. Surgeons and clinical nurse specialists reported higher levels of job satisfaction than team members who do not provide direct patient care, whilst MDT coordinators reported the lowest levels of job satisfaction and job stress. Both job stress and satisfaction decreased after participating in the Programme for all team members. There was a small improvement in team performance. Conclusions - Participation in the Development Programme had a mixed impact on the working lives of team members in the immediate aftermath of attending. The decrease in team members' job stress may reflect the improved knowledge and skills conferred by the Programme. The decrease in job satisfaction may be the consequence of being unable to apply these skills immediately in clinical practice because of a lack of required infrastructure and/or equipment. In addition, whilst the Programme raised awareness of the challenges of teamworking, a greater focus on tackling these issues may have improved working lives further.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With business incubators deemed as a potent infrastructural element for entrepreneurship development, business incubation management practice and performance have received widespread attention. However, despite this surge of interest, scholars have questioned the extent to which business incubation delivers added value. Thus, there is a growing awareness among researchers, practitioners and policy makers of the need for more rigorous evaluation of the business incubation output performance. Aligned to this is an increasing demand for benchmarking business incubation input/process performance and highlighting best practice. This paper offers a business incubation assessment framework, which considers input/process and output performance domains with relevant indicators. This tool adds value on different levels. It has been developed in collaboration with practitioners and industry experts and therefore it would be relevant and useful to business incubation managers. Once a large enough database of completed questionnaires has been populated on an online platform managed by a coordinating mechanism, such as a business incubation membership association, business incubator managers can reflect on their practices by using this assessment framework to learn their relative position vis-à-vis their peers against each domain. This will enable them to align with best practice in this field. Beyond implications for business incubation management practice, this performance assessment framework would also be useful to researchers and policy makers concerned with business incubation management practice and impact. Future large-scale research could test for construct validity and reliability. Also, discriminant analysis could help link input and process indicators with output measures.