907 resultados para POSITION-82
Resumo:
A sigmatropic methyl shift from the angular position C-1 in ring to the position C-20 between rings and constitutes the crucial step in syntheses leading to a 20-methyl-isobacteriochlorin and to 20-methyl-pyrrocorphins which served as substrates in the investigation presented in the accompanying communication.
Resumo:
Vorbesitzer: Eljāqīm Carmoly; Abraham Merzbacher
Resumo:
Vorbesitzer: Bartholomaeusstift Frankfurt am Main
Resumo:
The precise phylogenetic propinquity of Dura within the Tibeto-Burman or Trans-Himalayan language family has hitherto been indeterminate. In the absence of compelling comparative evidence, the language has previously been assigned to a subgroup in its own right within the linguistic phylum as a whole. Meanwhile, the Dura language is effectively extinct, although attempts at revival may be undertaken by well-intentioned members of Dura ethnicity. On the basis of a comprehensive study and analysis of all of the extant Dura language material, the phylogenetic position of the language within the family will be clarified. Comparative evidence from the Dura lexicon, its nominal and verbal morphology as well as from syntactic and phonological properties is adduced to determine the phylogenetic position of Dura. Moreover, this result will help explain some of the sociocultural realities associated with the Dura language community in Lamjung, Nepal
Resumo:
OBJECTIVE Cochlear implants (CI) are standard treatment for prelingually deafened children and postlingually deafened adults. Computed tomography (CT) is the standard method for postoperative imaging of the electrode position. CT scans accurately reflect electrode depth and position, which is essential prior to use. However, routine CT examinations expose patients to radiation, which is especially problematic in children. We examined whether new CT protocols could reduce radiation doses while preserving diagnostic accuracy. METHODS To investigate whether electrode position can be assessed by low-dose CT protocols, a cadaveric lamb model was used because the inner ear morphology is similar to humans. The scans were performed at various volumetric CT dose-indexes CTDIvol)/kV combinations. For each constant CTDIvol the tube voltage was varied (i.e., 80, 100, 120 and 140kV). This procedure was repeated at different CTDIvol values (21mGy, 11mGy, 5.5mGy, 2.8mGy and 1.8mGy). To keep the CTDIvol constant at different tube voltages, the tube current values were adjusted. Independent evaluations of the images were performed by two experienced and blinded neuroradiologists. The criteria diagnostic usefulness, image quality and artifacts (scaled 1-4) were assessed in 14 cochlear-implanted cadaveric lamb heads with variable tube voltages. RESULTS Results showed that the standard CT dose could be substantially reduced without sacrificing diagnostic accuracy of electrode position. The assessment of the CI electrode position was feasible in almost all cases up to a CTDIvol of 2-3mGy. The number of artifacts did not increase for images within this dose range as compared to higher dosages. The extent of the artifacts caused by the implanted metal-containing CI electrode does not depend on the radiation dose and is not perceptibly influenced by changes in the tube voltage. Summarizing the evaluation of the CI electrode position is possible even at a very low radiation dose. CONCLUSIONS CT imaging of the temporal bone for postoperative electrode position control of the CI is possible with a very low and significantly radiation dose. The tube current-time product and voltage can be reduced by 50% without increasing artifacts. Low-dose postoperative CT scans are sufficient for localizing the CI electrode.
Resumo:
Ischaemic spinal cord injury (SCI) remains the Achilles heel of open and endovascular descending thoracic and thoracoabdominal repair. Neurological outcomes have improved coincidentially with the introduction of neuroprotective measures. However, SCI (paraplegia and paraparesis) remains the most devastating complication. The aim of this position paper is to provide physicians with broad information regarding spinal cord blood supply, to share strategies for shortening intraprocedural spinal cord ischaemia and to increase spinal cord tolerance to transitory ischaemia through detection of ischaemia and augmentation of spinal cord blood perfusion. This study is meant to support physicians caring for patients in need of any kind of thoracic or thoracoabdominal aortic repair in decision-making algorithms in order to understand, prevent or reverse ischaemic SCI. Information has been extracted from focused publications available in the PubMed database, which are cohort studies, experimental research reports, case reports, reviews, short series and meta-analyses. Individual chapters of this position paper were assigned and after delivery harmonized by Christian D. Etz, Ernst Weigang and Martin Czerny. Consequently, further writing assignments were distributed within the group and delivered in August 2014. The final version was submitted to the EJCTS for review in September 2014.
Resumo:
The implementation of new surgical techniques offers chances but carries risks. Usually, several years pass before a critical appraisal and a balanced opinion of a new treatment method are available and rely on the evidence from the literature and expert's opinion. The frozen elephant trunk (FET) technique has been increasingly used to treat complex pathologies of the aortic arch and the descending aorta, but there still is an ongoing discussion within the surgical community about the optimal indications. This paper represents a common effort of the Vascular Domain of EACTS together with several surgeons with particular expertise in aortic surgery, and summarizes the current knowledge and the state of the art about the FET technique. The majority of the information about the FET technique has been extracted from 97 focused publications already available in the PubMed database (cohort studies, case reports, reviews, small series, meta-analyses and best evidence topics) published in English.
Resumo:
Chordomas are very rare bone malignant tumours that have had a shortage of effective treatments for a long time. New treatments are now available for both the local and the metastatic phase of the disease, but the degree of uncertainty in selecting the most appropriate treatment remains high and their adoption remains inconsistent across the world, resulting in suboptimum outcomes for many patients. In December, 2013, the European Society for Medical Oncology (ESMO) convened a consensus meeting to update its clinical practice guidelines on sarcomas. ESMO also hosted a parallel consensus meeting on chordoma that included more than 40 chordoma experts from several disciplines and from both sides of the Atlantic, with the contribution and sponsorship of the Chordoma Foundation, a global patient advocacy group. The consensus reached at that meeting is shown in this position paper.
Resumo:
Welsch (Projektbearbeiter): Appell von 50 Urwählern des Berliner 82. Bezirks, nur solche Wahlmänner zu wählen, die zur konstitutionellen Monarchie und zur Verfassung vom 5. Dezember 1848 stehen. Letztere ist aufgrund der Möglichkeit der Revision nicht unbedingt oktroyiert zu nennen.
Resumo:
There are large variations in the incidence, registration methods and reported causes of sudden cardiac arrest/sudden cardiac death (SCA/SCD) in competitive and recreational athletes. A crucial question is to which degree these variations are genuine or partly due to methodological incongruities. This paper discusses the uncertainties about available data and provides comprehensive suggestions for standard definitions and a guide for uniform registration parameters of SCA/SCD. The parameters include a definition of what constitutes an 'athlete', incidence calculations, enrolment of cases, the importance of gender, ethnicity and age of the athlete, as well as the type and level of sporting activity. A precise instruction for autopsy practice in the case of a SCD of athletes is given, including the role of molecular samples and evaluation of possible doping. Rational decisions about cardiac preparticipation screening and cardiac safety at sport facilities requires increased data quality concerning incidence, aetiology and management of SCA/SCD in sports. Uniform standard registration of SCA/SCD in athletes and leisure sportsmen would be a first step towards this goal.