972 resultados para Opção de Troca


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To quantify the effects of driver age on night-time pedestrian conspicuity, and to determine whether individual differences in visual performance can predict drivers' ability to recognise pedestrians at night. Methods Participants were 32 visually normal drivers (20 younger: M = 24.4 years ± 6.4 years; 12 older: M = 72.0 years ± 5.0 years). Visual performance was measured in a laboratory-based testing session including visual acuity, contrast sensitivity, motion sensitivity and the useful field of view. Night-time pedestrian recognition distances were recorded while participants drove an instrumented vehicle along a closed road course at night; to increase the workload of drivers, auditory and visual distracter tasks were presented for some of the laps. Pedestrians walked in place, sideways to the oncoming vehicles, and wore either a standard high visibility reflective vest or reflective tape positioned on the movable joints (biological motion). Results Driver age and pedestrian clothing significantly (p < 0.05) affected the distance at which the drivers first responded to the pedestrians. Older drivers recognised pedestrians at approximately half the distance of the younger drivers and pedestrians were recognised more often and at longer distances when they wore a biological motion reflective clothing configuration than when they wore a reflective vest. Motion sensitivity was an independent predictor of pedestrian recognition distance, even when controlling for driver age. Conclusions The night-time pedestrian recognition capacity of older drivers was significantly worse than that of younger drivers. The distance at which drivers first recognised pedestrians at night was best predicted by a test of motion sensitivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The population is ageing. Globally, the number of older adults (aged 60 years or over) is expected to more than double, from 841 million people in 2013 to more than 2 billion in 2050.1 In light of the increasing size of the older adult population, there is a pressing need to better identify the nature of, and mechanisms underlying, age-related vision impairment and the functional impact it has on the performance of everyday activities in older adults. The content of this feature issue reflects the diversity of research currently being undertaken on the topic of the ageing visual system and the important visual challenges that this presents for our ageing patient population. The scope is broad and includes topics relating to three main related themes: 1) The treatment of age-related ocular disorders and diseases and their consequences, including presbyopia and AMD; 2) The impact of age-related visual changes on everyday activities in older people, including mobility, driving and falls, and; 3) The interaction of age-related visual impairments and other age-related impairments including hearing and cognitive changes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To provide a comprehensive overview of research examining the impact of astigmatism on clinical and functional measures of vision, the short and longer term adaptations to astigmatism that occur in the visual system, and the currently available clinical options for the management of patients with astigmatism. Recent findings: The presence of astigmatism can lead to substantial reductions in visual performance in a variety of clinical vision measures and functional visual tasks. Recent evidence demonstrates that astigmatic blur results in short-term adaptations in the visual system that appear to reduce the perceived impact of astigmatism on vision. In the longer term, uncorrected astigmatism in childhood can also significantly impact on visual development, resulting in amblyopia. Astigmatism is also associated with the development of spherical refractive errors. Although the clinical correction of small magnitudes of astigmatism is relatively straightforward, the precise, reliable correction of astigmatism (particularly high astigmatism) can be challenging. A wide variety of refractive corrections are now available for the patient with astigmatism, including spectacle, contact lens and surgical options. Conclusion: Astigmatism is one of the most common refractive errors managed in clinical ophthalmic practice. The significant visual and functional impacts of astigmatism emphasise the importance of its reliable clinical management. With continued improvements in ocular measurement techniques and developments in a range of different refractive correction technologies, the future promises the potential for more precise and comprehensive correction options for astigmatic patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose Age-related changes in motion sensitivity have been found to relate to reductions in various indices of driving performance and safety. The aim of this study was to investigate the basis of this relationship in terms of determining which aspects of motion perception are most relevant to driving. Methods Participants included 61 regular drivers (age range 22–87 years). Visual performance was measured binocularly. Measures included visual acuity, contrast sensitivity and motion sensitivity assessed using four different approaches: (1) threshold minimum drift rate for a drifting Gabor patch, (2) Dmin from a random dot display, (3) threshold coherence from a random dot display, and (4) threshold drift rate for a second-order (contrast modulated) sinusoidal grating. Participants then completed the Hazard Perception Test (HPT) in which they were required to identify moving hazards in videos of real driving scenes, and also a Direction of Heading task (DOH) in which they identified deviations from normal lane keeping in brief videos of driving filmed from the interior of a vehicle. Results In bivariate correlation analyses, all motion sensitivity measures significantly declined with age. Motion coherence thresholds, and minimum drift rate threshold for the first-order stimulus (Gabor patch) both significantly predicted HPT performance even after controlling for age, visual acuity and contrast sensitivity. Bootstrap mediation analysis showed that individual differences in DOH accuracy partly explained these relationships, where those individuals with poorer motion sensitivity on the coherence and Gabor tests showed decreased ability to perceive deviations in motion in the driving videos, which related in turn to their ability to detect the moving hazards. Conclusions The ability to detect subtle movements in the driving environment (as determined by the DOH task) may be an important contributor to effective hazard perception, and is associated with age, and an individuals' performance on tests of motion sensitivity. The locus of the processing deficits appears to lie in first-order, rather than second-order motion pathways.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose There have been only a limited number of studies examining the accommodative response that occurs when the two eyes are provided with disparate accommodative stimuli, and the results from these studies to date have been equivocal. In this study, we therefore aimed to examine the capacity of the visual system to aniso-accommodate by objectively measuring the interocular difference in the accommodation response between fellow dominant and non-dominant eyes under controlled monocular and binocular viewing conditions during short-term exposure to aniso-accommodative stimuli. Methods The accommodative response of each eye of sixteen young isometropic adults (mean age 22 ± 2 years) with normal binocular vision was measured using an open-field autorefractor during a range of testing conditions; monocularly (accommodative demands ranging from 1.32 to 4.55 D) and binocularly while altering the accommodation demand for each eye (aniso-accommodative stimuli ranging from 0.24 to 2.05 D). Results Under monocular viewing conditions, the dominant and non-dominant eyes displayed a highly symmetric accommodative response; mean interocular difference in spherical equivalent 0.01 ± 0.06 D (relative) and 0.22 ± 0.06 D (absolute) (p>0.05). During binocular viewing, the dominant eye displayed a greater accommodative response (0.11 ± 0.34 D relative and 0.24 ± 0.26 D absolute) irrespective of whether the demand of the dominant or non-dominant eye was altered (p = 0.01). Astigmatic power vectors J0 and J45 did not vary between eyes or with increasing accommodation demands under monocular or binocular viewing conditions (p>0.05). Conclusion The dominant and non-dominant eyes of young isometropic individuals display a similar consensual lag of accommodation under both monocular and binocular viewing conditions, with the dominant eye showing a small but significantly greater (by 0.12 to 0.25 D) accommodative response. Evidence of short-term aniso-accommodation in response to asymmetric accommodation demands was not observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose Optical blur and ageing are known to affect driving performance but their effects on drivers' eye movements are poorly understood. This study examined the effects of optical blur and age on eye movement patterns and performance on the DriveSafe slide recognition test which is purported to predict fitness to drive. Methods Twenty young (27.1 ± 4.6 years) and 20 older (73.3 ± 5.7 years) visually normal drivers performed the DriveSafe under two visual conditions: best-corrected vision and with +2.00 DS blur. The DriveSafe is a Visual Recognition Slide Test that consists of brief presentations of static, real-world driving scenes containing different road users (pedestrians, bicycles and vehicles). Participants reported the types, relative positions and direction of travel of the road users in each image; the score was the number of correctly reported items (maximum score of 128). Eye movements were recorded while participants performed the DriveSafe test using a Tobii TX300 eye tracking system. Results There was a significant main effect of blur on DriveSafe scores (best-corrected: 114.9 vs blur: 93.2; p < 0.001). There was also a significant age and blur interaction on the DriveSafe scores (p < 0.001) such that the young drivers were more negatively affected by blur than the older drivers (reductions of 22% and 13% respectively; p < 0.001): with best-corrected vision, the young drivers performed better than the older drivers (DriveSafe scores: 118.4 vs 111.5; p = 0.001), while with blur, the young drivers performed worse than the older drivers (88.6 vs 95.9; p = 0.009). For the eye movement patterns, blur significantly reduced the number of fixations on road users (best-corrected: 5.1 vs blur: 4.5; p < 0.001), fixation duration on road users (2.0 s vs 1.8 s; p < 0.001) and saccade amplitudes (7.4° vs 6.7°; p < 0.001). A main effect of age on eye movements was also found where older drivers made smaller saccades than the young drivers (6.7° vs 7.4°; p < 0.001). Conclusions Blur reduced DriveSafe scores for both age groups and this effect was greater for the young drivers. The decrease in number of fixations and fixation duration on road users, as well as the reduction in saccade amplitudes under the blurred condition, highlight the difficulty experienced in performing the task in the presence of optical blur, which suggests that uncorrected refractive errors may have a detrimental impact on aspects of driving performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE To estimate refractive indices used by the Lenstar biometer to translate measured optical path lengths into geometrical path lengths within the eye. METHODS Axial lengths of model eyes were determined using the IOLMaster and Lenstar biometers; comparing those lengths gave an overall eye refractive index estimate for the Lenstar. Using the Lenstar Graphical User Interface, we noticed that boundaries between media could be manipulated and opposite changes in optical path lengths on either side of the boundary could be introduced. Those ratios were combined with the overall eye refractive index to estimate separate refractive indices. Furthermore, Haag-Streit provided us with a template to obtain 'air thicknesses' to compare with geometrical distances. RESULTS The axial length estimates obtained using the IOLMaster and the Lenstar agreed to within 0.01 mm. Estimates of group refractive indices used in the Lenstar were 1.340, 1.341, 1.415, and 1.354 for cornea, aqueous, lens, and overall eye, respectively. Those refractive indices did not match those of schematic eyes, but were close in the cases of aqueous and lens. Linear equations relating air thicknesses to geometrical thicknesses were consistent with our findings. CONCLUSION The Lenstar uses different refractive indices for different ocular media. Some of the refractive indices, such as that for the cornea, are not physiological; therefore, it is likely that the calibrations in the instrument correspond to instrument-specific corrections and are not the real optical path lengths.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A recent suggestion by a reviewer of a manuscript that the use of the word ‘hypermetropia’ was incorrect and that it should be replaced by ‘hyperopia’ caused us to look again at the literature of the subject to see if this criticism was justified. The background is an interesting one...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To provide a summary of the classic paper "Differences in the accommodation stimulus response curves of adult myopes and emmetropes" published in Ophthalmic and Physiological Optics in 1998 and to provide an update on the topic of accommodation errors in myopia. Summary The accommodation responses of 33 participants (10 emmetropes, 11 early onset myopes and 12 late onset myopes) aged 18-31 years were measured using the Canon Autoref R-1 free space autorefractor using three methods to vary the accommodation demand: decreasing distance (4 m to 0.25 cm), negative lenses (0 to -4 D at 4 m) and positive lenses (+4 to 0 D at 0.25 m). We observed that the greatest accommodation errors occurred for the negative lens method whereas minimal errors were observed using positive lenses. Adult progressing myopes had greater lags of accommodation than stable myopes at higher demands induced by negative lenses. Progressing myopes had shallower response gradients than the emmetropes and stable myopes; however the reduced gradient was much less than that observed in children using similar methods. Recent Findings This paper has been often cited as evidence that accommodation responses at near may be primarily reduced in adults with progressing myopia and not in stable myopes and/or that challenging accommodation stimuli (negative lenses with monocular viewing) are required to generate larger accommodation errors. As an analogy, animals reared with hyperopic errors develop axial elongation and myopia. Retinal defocus signals are presumably passed to the retinal pigment epithelium and choroid and then ultimately the sclera to modify eye length. A number of lens treatments that act to slow myopia progression may partially work through reducing accommodation errors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose Transient changes in corneal topography associated with soft and conventional or reverse geometry rigid contact lens wear have been well documented; however, only a few studies have examined the influence of scleral contact lens wear upon the cornea. Therefore, in this study, we examined the influence of modern miniscleral contact lenses, which land entirely on the sclera and overlying tissues, upon anterior corneal curvature and optics. Methods Anterior corneal topography and elevation data were acquired using Scheimpflug imaging (Pentacam HR, Oculus) immediately prior to and following 8 hours of miniscleral contact lens wear in 15 young healthy adults (mean age 22 ± 3 years, 8 East Asian, 7 Caucasian) with normal corneae. Corneal diurnal variations were accounted for using data collected on a dedicated measurement day without contact lens wear. Corneal clearance was quantified using an optical coherence tomographer (RS-3000, Nidek) following lens insertion and after 8 hours of lens wear. Results Although corneal clearance was maintained throughout the 8 hour lens wear period, significant corneal flattening (up to 0.08 ± 0.04 mm) was observed, primarily in the superior mid-peripheral cornea, which resulted in a slight increase in against-the-rule corneal astigmatism (mean +0.02/-0.15 x 94 for an 8 mm diameter). Higher order aberration terms of horizontal coma, vertical coma and spherical aberration all underwent significant changes for an 8 mm corneal diameter (p ≤ 0.01), which typically resulted in a decrease in RMS error values (mean change in total higher order RMS -0.035 ± 0.046 µm for an 8 mm diameter). There was no association between the magnitude of change in central or mid-peripheral corneal clearance during lens wear and the observed changes in corneal curvature (p > 0.05). However, Asian participants displayed a significantly greater reduction in corneal clearance (p = 0.04) and greater superior-nasal corneal flattening compared to Caucasians (p = 0.048). Conclusions Miniscleral contact lenses that vault the cornea induce significant changes in anterior corneal surface topography and higher order aberrations following 8 hours of lens wear. The region of greatest corneal flattening was observed in the superior-nasal mid-periphery, more so in Asian participants. Practitioners should be aware that corneal measurements obtained following miniscleral lens removal may mask underlying corneal steepening.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To explore the effect of small-aperture optics, designed to aid presbyopes by increasing ocular depth-of-focus, on measurements of the visual field. Methods Simple theoretical and ray-tracing models were used to predict the impact of different designs of small-aperture contact lenses or corneal inlays on the proportion of light passing through natural pupils of various diameters as a function of the direction in the visual field. The left eyes of five healthy volunteers were tested using three afocal, hand-painted opaque soft contact lenses (www.davidthomas.com). Two were opaque over a 10 mm diameter but had central clear circular apertures of 1.5 and 3.0 mm in diameter. The third had an annular opaque zone with inner and outer diameters of 1.5 and 4.0 mm, approximately simulating the geometry of the KAMRA inlay (www.acufocus.com). A fourth, clear lens was used for comparison purposes. Visual fields along the horizontal meridian were evaluated up to 50° eccentricity with static automated perimetry (Medmont M700, stimulus Goldmann-size III; www.medmont.com). Results According to ray-tracing, the two lenses with the circular apertures were expected to reduce the relative transmittance of the pupil to zero at specific field angles (around 60° for the conditions of the experimental measurements). In contrast, the annular stop had no effect on the absolute field but relative transmittance was reduced over the central area of the field, the exact effects depending upon the natural pupil diameter. Experimental results broadly agreed with these theoretical expectations. With the 1.5 and 3.0 mm pupils, only minor losses in sensitivity (around 2 dB) in comparison with the clear-lens case occurred across the central 10° radius of field. Beyond this angle, sensitivity losses increased, to reach about 7 dB at the edge of the measured field (50°). The field results with the annular stop showed at most only a slight loss in sensitivity (≤3 dB) across the measured field. Conclusion The present theoretical and experimental results support earlier clinical findings that KAMRA-type annular stops, unlike circular artificial pupils, have only minor effects on measurements of the visual field.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pregnancy rates (PR) to fixed-time AI (FTAI) in Brahman heifers were compared after treatment with a traditional oestradiol-based protocol (OPO-8) or a modified protocol (OPO-6) where the duration of intravaginal progesterone releasing device (IPRD) was reduced from 8 to 6 days, and the interval from IPRD removal to oestradiol benzoate (ODB) was increased from 24 to 36 h. Rising 2 yo heifers on Farm A: (n = 238 and n = 215; two consecutive days AI); B (n = 271); and C (n = 393) were allocated to OPO-8 or OPO-6. An IPRD was inserted and 1 mg ODB i.m. on Day 0 for OPO-8 heifers and Day 2 for OPO-6 heifers. On Day 8, the IPRD was removed and 500 μg cloprostenol i.m. At 24 h, for OPO-8 heifers, and 36 h, for OPO-6 heifers, post IPRD removal all heifers received 1 mg ODB i.m. FTAI was conducted at 54 and 72 h post IPRD removal for OPO-8 and OPO-6 heifers. At Farm A, OPO-6 heifers, AI on the second day, the PR was 52.4 to FTAI (P = 0.024) compared to 36.8 for OPO-8 heifers. However, no differences were found between OPO-8 and OPO-6 protocols at Farm A (first day of AI) (39.9 vs. 35.7), or Farms B (26.2 vs. 35.4) and C (43.2 vs. 40.3). Presence of a corpus luteum at IPRD insertion affected PR to FTAI (43.9 vs. 28.8; P < 0.001). This study has shown that the modified ovulation synchronisation protocol OPO-6 may be a viable alternative to the OPO-8 protocol for FTAI in B. indicus heifers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To examine whether anterior scleral and conjunctival thickness undergoes significant diurnal variation over a 24-hour period. Methods Nineteen healthy young adults (mean age 22 ± 2 years) with minimal refractive error (mean spherical equivalent refraction -0.08 ± 0.39 D), had measures of anterior scleral and conjunctival thickness collected using anterior segment optical coherence tomography (AS-OCT) at seven measurement sessions over a 24-hour period. The thickness of the temporal anterior sclera and conjunctiva were determined at 6 locations (each separated by 0.5 mm) at varying distances from the scleral spur for each subject at each measurement session. Results Both the anterior sclera and conjunctiva were found to undergo significant diurnal variations in thickness over a 24-hour period (both p <0.01). The sclera and conjunctiva exhibited a similar pattern of diurnal change, with a small magnitude thinning observed close to midday, and a larger magnitude thickening observed in the early morning immediately after waking. The amplitude of diurnal thickness change was larger in the conjunctiva (mean amplitude 69 ± 29 μm) compared to the sclera (21 ± 8 μm). The conjunctiva exhibited its smallest magnitude of change at the scleral spur location (mean amplitude 56 ± 17 μm) whereas the sclera exhibited its largest magnitude of change at this location (52 ± 21 μm). Conclusions This study provides the first evidence of diurnal variations occurring in the thickness of the anterior sclera and conjunctiva. Studies requiring precise measures of these anatomical layers should therefore take time of day into consideration. The majority of the observed changes occurred in the early morning immediately after waking and were of larger magnitude in the conjunctiva compared to the sclera. Thickness changes at other times of the day were of smaller magnitude and generally not statistically significant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wavelength tuning and stability characteristics of a singly resonant continuous-wave optical parametric oscillator (cw OPO) in the proximity of signal-idler degeneracy have been studied. The OPO is made singly resonant by using a Bragg grating as a spectral filter in the OPO cavity. The signal-idler frequency difference can be tuned from 0.5 to 7 THz, which makes the OPO suitable for cw THz generation by optical heterodyning. The operation of the OPO within this singly-resonant regime is characterized by a strong self-stabilization effect. A gradual transition to an unstable, doubly-resonant regime is observed for a signal-idler detuning smaller than ~ 0.5 THz.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Soft-chemical oxidation of KTiOPO4-like KM(0.5)(V)Ti(0.5)(III)OPO(4) (M = Nb, Ta) using chlorine in CHCl3 is accompanied by partial deintercalation of potassium, yielding K(0.5)MV(0.5)Ti(0.5)(IV)OPO(4) compounds which are new non-linear optical materials that exhibit efficient second-harmonic generation of 1064 nm radiation, as does KTiOPO4.