973 resultados para One-point Quadrature
Resumo:
Rapid accumulation of few polyhedra (FP) mutants was detected during serial passaging of Helicoverpa armigera nucleopolyhedrovirus (HaSNPV) in cell culture. 100% FP infected cells were observed by passage 6. The specific yield decreased from 178 polyhedra per cell at passage 2 to two polyhedra per cell at passage 6. The polyhedra at passage 6 were not biologically active, with a 28-fold reduction in potency compared to passage 3. Electron microscopy studies revealed that very few polyhedra were produced in an FP infected cell (< 10 polyhedra per section) and in most cases these polyhedra contained no virions. A specific failure in the intranuclear nucleocapsid envelopment process in the FP infected cells, leading to the accumulation of naked nucleocapsids, was observed. Genomic restriction endonuclease digestion profiles of budded virus DNA from all passages did not indicate any large DNA insertions or deletions that are often associated with such FP phenotypes for the extensively studied Autographa californica nucleopolyhedrovirus and Gaileria mellonella nucleopolyhedrovirus. Within an HaSNPV 25K FP gene homologue, a single base-pair insertion (an adenine residue) within a region of repetitive sequences (seven adenine residues) was identified in one plaque-purified HaSNPV FP mutant. Furthermore, the sequences obtained from individual clones of the 25KFP gene PCR products of a late passage revealed point mutations or single base-pair insertions occurring throughout the gene. The mechanism of FP mutation in HaSNPV is likely similar to that seen for Lymantria dispar nucleopolyhedrovirus, involving point mutations or small insertions/deletions of the 25K FP gene.
Resumo:
A new cloud-point extraction and preconcentration method, using a cationic, surfactant, Aliquat-336 (tricaprylyl-methy;ammonium chloride), his-been developed for the determination of cyanobacterial toxins, microcystins, in natural waters. Sodium sulfate was used to induce phase separation at 25 degreesC. The phase behavior of Aliquat-336 with respect to concentration of Na2SO4 was studied. The cloud-point system revealed a very high phase volume ratio compared to other established systems of nonionic, anionic, and cationic surfactants: At pH 6-7, it showed an outstanding selectivity in ahalyte extraction for anionic species. Only MC-LR and MC-YR, which are known to be predominantly anionic, were extracted (with averaged recoveries of 113.9 +/- 9% and 87.1 +/- 7%, respectively). MC-RR, which is likely to be amphoteric at the above pH range, was. not cle tectable in.the extract. Coupled to HPLC/UV separation and detection, the cloud-point extraction method (with 2.5 mM Aliquat-336 and 75 mM Na2SO4 at 25 degreesC) offered detection limits of 150 +/- 7 and 470 +/- 72 pg/mL for MC-LR and MC-YR, respectively, in 25 mL of deionized water. Repeatability of the method was 7.6% for MC-LR and 7.3% for MC-YR: The cloud-point extraction process can be. completed within 10-15 min with no cleanup steps required. Applicability of the new method to the determination of microcystins in real samples was demonstrated using natural surface waters, collected from a local river and a local duck pond spiked with realistic. concentrations of microcystins. Effects of salinity and organic matter (TOC) content in the water sample on the extraction efficiency were also studied.
Resumo:
Manual therapy, exercise and education target distinct aspects of chronic low back pain and probably have distinct effects, This study aimed to determine the efficacy of a combined physiotherapy treatment that comprised all of these strategies. By concealed randomisation, 57 chronic low back pain patients were allocated to either the four-week physiotherapy program or management as directed by their general practitioners, The dependent variables of interest were pain and disability. Assessors were blind to treatment group. Outcome data from 49 subjects (86%) showed a significant treatment effect. The physiotherapy program reduced pain and disability by a mean of 1.5/10 points on a numerical rating scale (95% CI 0.7 to 2.3) and 3.9 points on the 18-point Roland Morris Disability Questionnaire (95% CI 2 to 5.8), respectively. The number needed to treat in order to gain a clinically meaningful change was 3 (95% CI 3 to 8) for pain, and 2 (95% CI 2 to 5) for disability. A treatment effect was maintained at one-year follow-up. The findings support the efficacy of combined physiotherapy treatment in producing symptomatic and functional change in moderately disabled chronic low back pain patients.
Resumo:
Fixed-point roundoff noise in digital implementation of linear systems arises due to overflow, quantization of coefficients and input signals, and arithmetical errors. In uniform white-noise models, the last two types of roundoff errors are regarded as uniformly distributed independent random vectors on cubes of suitable size. For input signal quantization errors, the heuristic model is justified by a quantization theorem, which cannot be directly applied to arithmetical errors due to the complicated input-dependence of errors. The complete uniform white-noise model is shown to be valid in the sense of weak convergence of probabilistic measures as the lattice step tends to zero if the matrices of realization of the system in the state space satisfy certain nonresonance conditions and the finite-dimensional distributions of the input signal are absolutely continuous.
Resumo:
We compared the quality of realtime fetal ultrasound images transmitted using ISDN and IP networks. Four experienced obstetric ultrasound specialists viewed standard recordings in a randomized trial and rated the appearance of 30 fetal anatomical landmarks, each on a seven-point scale. A total of 12 evaluations were performed for various combinations of bandwidths (128, 384 or 768 kbit/s) and networks (ISDN or IF). The intraobserver coefficient of variation was 2.9%, 5.0%, 12.7% and 14.7% for the four observers. The mean overall ratings by each of the four observers were 4.6, 4.8, 5.0 and 5.3, respectively (a rating of 4 indicated satisfactory visualization and 7 indicated as good as the original recording). Analysis of variance showed that there were no significant interobserver variations nor significant differences in the mean scores for the different types of videoconferencing machines used. The most significant variable affecting the mean score was the bandwidth used. For ISDN, the mean score was 3.7 at 128 kbit/s, which was significantly worse than the mean score of 4.9 at 384 kbit/s, which was in turn significantly worse than the mean score of 5.9 at 768 kbit/s. The mean score for transmission using IP was about 0.5 points lower than that using ISDN across all the different bandwidths, but the differences were not significant. It appears that IP transmission in a private (non-shared) network is an acceptable alternative to ISDN for fetal tele-ultrasound and one deserving further study.
Resumo:
We investigate difference equations which arise as discrete approximations to two-point boundary value problems for systems of second-order, ordinary differential equations. We formulate conditions under which all solutions to the discrete problem satisfy certain a priori bounds which axe independent of the step-size. As a result, the nonexistence of spurious solutions are guaranteed. Some existence and convergence theorems for solutions to the discrete problem are also presented. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
Objective: To compare head relocation accuracy in traumatic ( whiplash), insidious onset neck pain patients and asymptomatic subjects when targeting a natural head posture (NHP) and complex predetermined positions. Design: A case-control study. Setting: University-based musculoskeletal research clinic. Participants: Sixty-three volunteers divided into three groups of similar gender and age: Group 1 (n=21) an asymptomatic group; group 2 (n=20) insidious onset neck pain; group 3 (n=22) a history of whiplash injury. Intervention: Five randomly ordered tests designed to detect relocation accuracy of the head. Outcome measures: A 3-Space Fastrak system measured the mean absolute relocation error of three trials of each relocation test. Results: A significant difference was found between groups in one of the tests targeting the NHP (p=0.001). Post-hoc pairwise comparisons revealed a significant difference (pless than or equal to0.05) between the asymptomatic group and each symptomatic group. The difference between the symptomatic groups just failed to reach significance (p=0.07). None of the other four tests revealed significant differences. Conclusion: The test of targeting the NHP indicates that relocation inaccuracy exists in patients with neck pain with a trend to suggest that the deficit may be greater in whiplash patients. Tests employing unfamiliar postures or more complex movement were not successful in differentiating subject groups.
Resumo:
The effect of unitary noise on the discrete one-dimensional quantum walk is studied using computer simulations. For the noiseless quantum walk, starting at the origin (n=0) at time t=0, the position distribution P-t(n) at time t is very different from the Gaussian distribution obtained for the classical random walk. Furthermore, its standard deviation, sigma(t) scales as sigma(t)similar tot, unlike the classical random walk for which sigma(t)similar toroott. It is shown that when the quantum walk is exposed to unitary noise, it exhibits a crossover from quantum behavior for short times to classical-like behavior for long times. The crossover time is found to be Tsimilar toalpha(-2), where alpha is the standard deviation of the noise.