963 resultados para NYLON-1010
Resumo:
Background: The aim of this study was to analyze stable hypertrophied myocardial function and its response to inotropic maneuvers in rats submitted to renovascular hypertension for a 10-week period (RHT group, n=10). Material/Methods: Myocardial performance was studied in isolated left ventricle papillary muscles in isometric contraction under the following conditions: at postrest contraction of 30 seconds (PRC), at extracellular calcium (ECa 2+) chloride concentration of 1.25 and 5.20 mM, and after beta-adrenergic stimulation with 10 -6 M isoproterenol (ISOP). Results: The results were compared with normotensive Wistar controls rats (C group, n=10). In basal condition, resting tension, and contraction time (TPT) were greater, while relaxation time (RT 50) tended to be longer in RHT than C group. PRC and ISOP promoted a similar change in muscle function response intensity (Δ) in both groups. ECa 2+ shift did not change TPT in the C group and decreased TPT in the RHT animals; Δ was different between these groups. RT 50 increased in C and decreased in RHT, both without statistical significance; however, Δ was different. Conclusions: These results suggest that hypertrophied myocardial dysfunction may be attibuted to changes in intracellular calcium cycling. © Med Sci Monit, 2010.
Resumo:
Times of in situ incubation (144 and 288h) for determination of internal markers IADF and INDF and the effects of differents procedures (wash or not the nylon bag every 72h incubation) was evaluated in samples of diet, duodenal digesta and cattle feces. The duodenal flow dry matter and fecal production utilizing the internal markers to compare with the external marker chromium oxide there was estimated. The animals were fed with sorgum silage, concentrate or urea. In this experiment, a latin square design was used, in a factorial scheme (two times of incubation × two processing nylon bag). No was observed effect of the incubation time or processing in the internal markers INDF and IADF concentration and the in situ incubation after 144h is adequate to reproduce the indigestible markers fraction in samples. For fecal production estimation, the external marker chromium oxide presented similar result (1.26 kg day-1) as the total fecal collection (1.49 kg day-1). Both the internal markers overestimate the duodenal flow dry matter when compared with the external marker chromium oxide.
Resumo:
Aim: There is little information considering the framework association between cast clasps and attachments. The aim of this study was to evaluate the retention strength of frameworks match circumferential clasps and extra resilient attachment cast in three different alloys (cobalt-chromium, nickel-chromium titanium and commercially pure titanium), using two undercut (0.25 and 0.75 mm) and considering different period of time (0, 1/2, 1, 2, 3, 4 and 5 years). Methods: Using two metallic matrices, representing a partially edentulous mandibular right hemiarch with the first molar crown, canine root and without premolars, 60 frameworks were fabricated. Three groups (n = 20) of each metal were cast and each group was divided into two subgroups (n = 10), corresponding the molar undercut of 0.25 mm and 0.75 mm. The nylon male was positioned at the matrix and attached to the acrylic resin of the prosthetic base. The samples were subjected to an insertion and removal test under artificial saliva environment. Results: The data were analyzed and compared with ANOVAs and Tukey's test at 95% of probability. The groups cast in cobaltchromium and nickel-chromium-titanium had the highest mean retention strength (5.58 N and 6.36 N respectively) without significant difference between them, but statistically different from the group cast in commercially pure titanium, which had the lowest mean retention strength in all the periods (3.46 N). The association frameworks using nickel-chromium-titanium and cobalt-chromium could be used with 0.25 mm and 0.75 mm of undercut, but the titanium samples seems to decrease the retention strength, mainly in the 0.75 mm undercut. The circumferential clasps cast in commercially pure titanium used in 0.75 mm undercuts have a potential risk of fractures, especially after the 2nd year of use. Conclusion: This in vitro study showed that the framework association between cast clasp and an extra resilient attachment are suitable to the three metals evaluated, but strongly suggest extra care with commercially pure titanium in undercut of 0.75 mm. Clinical significance: Frameworks fabricated in Cp Ti tend to decrease in retentive strength over time and have a potential risk of fracture in less than 0.75 mm of undercut.
Resumo:
Osteopetrosis (OP) is a rare hereditary disorder characterized by a dysfunction of the osteoclasts that impairs bone resorption, which together with the normal osteoblastic activity forms intense bone sclerosis with reduction of marrow. A common complication that arises, most frequently, as a result of tooth extraction is mandibular osteomyelitis. There is no consensus on the literature about the treatment of this infection in an osteopetrotic patient, therefore, the purpose of this paper is to report a case of marginal resection for treatment of mandibular osteomyelitis in an osteopetrotic patient and discuss relevant features of this procedure. © 2010 European Association for Cranio-Maxillo-Facial Surgery.
Resumo:
ITO nanowires were synthesized by carbothermal reduction process, using a co-evaporation method, and have controlled size, shape, and chemical composition. The electrical measurements of nanowires showed they have a resistance of about 102 Ω. In order to produce nanocomposites films, nanowires were dispersed in toluene using an ultrasonic cleaner, so the PMMA polymer was added, and the system was kept under agitation up to obtain a clear suspension. The PMMA polymer was filled with 1, 2, 5 and 10% in weight of nanowires, and the films were done by tape casting. The results showed that the electrical resistance of nanocomposites changed by over 7 orders of magnitude by increasing the amount of filler, and using 5 wt% of filler the composite resistance decreased from 1010 Ω to about 104 Ω, which means that percolation threshold of wires occurred at this concentration. This is an interesting result once for nanocomposites filled with ITO nanoparticles is necessary about 18% in weight to obtain percolation. The addition of filler up to 10 wt% decreased the resistance of the composite to 103 Ω, which is a value close to the resistance of wires. The composites were also analyzed by transmission electron microscopy (TEM), and the TEM results are in agreement with the electrical ones about percolation of nanowires. These results are promising once indicates that is possible to produce conductive and transparent in the visible range films by the addition of ITO nanowires in a polymeric matrix using a simple route. © 2011 Materials Research Society.
Resumo:
The aim of this study is to report the case of a quick growing brown tumour in the jaw after a parathyroidectomy due to the presence of a rare fifth parathyroid gland. The patient had chronic renal disease and the diagnosis was tertiary hyperparathyroidism. Thirty days after the parathyroidectomy, the patient returned with a significant increase in the tumour size. The suspicion of a supernumerary gland was confirmed by parathyroid scintigraphy. The treatment of brown tumour is dependent on the treatment of the hyperparathyroidism. However, curettage should be considered if a large lesion is disturbing mastication. In conclusion, this case should attract the attention of general practitioner dentists, since they may be the first professionals who have contact with the patient with a brown tumour in the jaws. Likewise, this case emphasises the importance of knowing the type of hyperparathyroidism involved to allow for effective treatment planning. © 2011 European Association for Cranio-Maxillo-Facial Surgery.
Resumo:
Incluye Bibliografía
Resumo:
Incluye Bibliografía
Resumo:
Previo la discusion del origen y objetivos del CELADE, se describe el programa general de ensenanza del Centro con enfasis en el Curso Basico de Demografia
Resumo:
The increased use of orofacial fillers in cosmetic procedures has led to new diagnostic challenges for dentists and oral pathologists. Here, we describe a case with multiple oral foreign body granulomas, which were formed after a polymethylmetacrylate injection for cosmetic purposes. © 2011 European Association for Cranio-Maxillo-Facial Surgery.
Resumo:
Incluye Bibliografía
Resumo:
Porous ceramics can be produced by adding starch (corn, potato) and protein (animal or vegetable) to raw material as pore forming element. In this study, titanium dioxide ceramics were formed by vegetable protein consolidation. Soybean was chosen as the binding agent and pore forming. The samples, which were produced in cylindrical shape, had the following processing: material mixture, gelling, drying, pre-sintering and sintering. Heated platinum microscopy were performed by using suspensions with different compositions in order to verify protein gelling capacity and better know the temperature in which this process occurs. The samples were characterized by apparent porosity and roughness measurement. Besides, imaging by light microscopy was also performed in order to determine the sample morphology and porosity. © (2012) Trans Tech Publications, Switzerland.
Resumo:
Chromatographic and electroanalytical methods were developed to detect and quantify Sudan II (SD-II) dye in fuel ethanol samples. Sudan II is reduced at +0.50 V vs. Ag/AgCl on a glassy carbon electrode using Britton-Robinson buffer (pH 4.0) and N,N-dimethylformamide (70:30, v/v) + sodium dioctyl sulfosuccinate surfactant as supporting electrolyte, due to the azo group. This is the basis for its determination by square-wave voltammetry (SWV). Using the optimized conditions, it is possible to get a linear calibration curve from 3.00×10-6 to 1.80×10-5 mol L-1 (r = 0.998) with limits of detection (LOD) and quantification (LOQ) of 2.05×10-6 and 6.76×10-6 mol L-1, respectively. In addition, the hydroxyl substituent in the SD-II dye is also oxidized at +0.85 V vs. Ag/AgCl, which was conveniently used for its determination by high-performance liquid chromatography coupled to electrochemical detection (HPLC-ED). Under the optimized condition, the SD-II dye was eluted and separated using a reversed-phase column (cyanopropyl, CN) using isocratic elution with the mobile phase containing acetonitrile and aqueous lithium chloride (5.00×10-4 mol L-1) at 70:30 (v/v) and a flow rate of 1.2 mL min-1. Linear calibration curves were obtained from 3.00×10-7 to 2.00×10-6 mol L-1 (r = 0.999) with LOD and LOQ of 3.10×10-8 and 1.05×10-7 mol L-1, respectively. Both methods were simple, fast and suitable to detect and quantify the dye in fuel ethanol samples at recovery values between 83.0 to 102% (SWV) and 88.0 to 112% (HPLC-ED) with satisfactory precision and accuracy.
Resumo:
Five new lanthanide(III) complexes of hydrocinnamic acid (Hcin), [Ln(cin)3(H2O)3]·3Hcin (Ln = Tb(III) (1), Dy(III) (2), Er(III) (3), Eu(III) (4) and Gd(III) (5)) have been synthesized and characterized. The X-ray structures of 1-5 reveal that all compounds are isostructural and that each lanthanide ion is nine-coordinated by oxygen atoms in an overall distorted tricapped trigonal-prismatic geometry. Six oxygen atoms are provided by carboxylate moieties, and the other three by water molecules. The supramolecular architectures of 1-5 show the presence of uncoordinated hydrocinnamic acid molecules which induce the formation of numerous hydrogen bonds. The photophysical properties of these complexes in the solid state at room temperature were studied using diffuse reflectance (DR), fluorescence excitation and emission spectra. An energy level diagram was used to establish the most relevant channels involved in the ligand-to-metal energy transfer, indicating that cin- ligands can act as intramolecular energy donors for Tb(III), Dy(III) and Eu(III) ions. © 2012 Elsevier B.V.
Resumo:
The purpose of this study is to determine the expression of CCL19, CCL21, and CCR7 in samples of oral squamous cell carcinoma (OSCC) and their relationship with clinical and microscopic parameters. A comparative analysis was made of the mRNA expression of these chemokines and receptor in OSCC and normal oral mucosa. The immunoexpression of CCR7, CCL19, and CCL21 was also verified in OSCC and lymph nodes. Statistical significance was accepted at P < 0.05. Similar levels of CCR7, CCL19, and CCL21 mRNA in OSCC and normal oral mucosa were seen. A low expression of CCL19 and CCL21 in the intra- and peritumoral regions was observed. Scarce CCL19+ and CCL21+ cells were also noted in metastatic and non-metastatic lymph nodes. No association was found between the expression of these chemokines and clinical and microscopic parameters. Our findings would suggest that CCL19 and CCL21 may not be associated with cervical lymph node metastasis or other clinical and microscopic factors in OSCC. © 2012 International Society of Oncology and BioMarkers (ISOBM).