943 resultados para Model-driven design
Resumo:
We present a controlled stress microviscometer with applications to complex fluids. It generates and measures microscopic fluid velocity fields, based on dual beam optical tweezers. This allows an investigation of bulk viscous properties and local inhomogeneities at the probe particle surface. The accuracy of the method is demonstrated in water. In a complex fluid model (hyaluronic acid), we observe a strong deviation of the flow field from classical behavior. Knowledge of the deviation together with an optical torque measurement is used to determine the bulk viscosity. Furthermore, we model the observed deviation and derive microscopic parameters.
Resumo:
Numerical methods are used to simulate the double-diffusion driven convective pore-fluid flow and rock alteration in three-dimensional fluid-saturated geological fault zones. The double diffusion is caused by a combination of both the positive upward temperature gradient and the positive downward salinity concentration gradient within a three-dimensional fluid-saturated geological fault zone, which is assumed to be more permeable than its surrounding rocks. In order to ensure the physical meaningfulness of the obtained numerical solutions, the numerical method used in this study is validated by a benchmark problem, for which the analytical solution to the critical Rayleigh number of the system is available. The theoretical value of the critical Rayleigh number of a three-dimensional fluid-saturated geological fault zone system can be used to judge whether or not the double-diffusion driven convective pore-fluid flow can take place within the system. After the possibility of triggering the double-diffusion driven convective pore-fluid flow is theoretically validated for the numerical model of a three-dimensional fluid-saturated geological fault zone system, the corresponding numerical solutions for the convective flow and temperature are directly coupled with a geochemical system. Through the numerical simulation of the coupled system between the convective fluid flow, heat transfer, mass transport and chemical reactions, we have investigated the effect of the double-diffusion driven convective pore-fluid flow on the rock alteration, which is the direct consequence of mineral redistribution due to its dissolution, transportation and precipitation, within the three-dimensional fluid-saturated geological fault zone system. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
The main aim of this study is to evaluate the capacity of human dental pulp stem cells (hDPSC), isolated from deciduous teeth, to reconstruct large-sized cranial bone defects in nonimmunosuppressed (NIS) rats. To our knowledge, these cells were not used before in similar experiments. We performed two symmetric full-thickness cranial defects (5 x 8 mm) on each parietal region of eight NIS rats. In six of them, the left side was supplied with collagen membrane only and the right side (RS) with collagen membrane and hDPSC. In two rats, the RS had collagen membrane only and nothing was added at the left side (controls). Cells were used after in vitro characterization as mesenchymal cells. Animals were euthanized at 7, 20, 30, 60, and 120 days postoperatively and cranial tissue samples were taken from the defects for histologic analysis. Analysis of the presence of human cells in the new bone was confirmed by molecular analysis. The hDPSC lineage was positive for the four mesenchymal cell markers tested and showed osteogenic, adipogenic, and myogenic in vitro differentiation. We observed bone formation 1 month after surgery in both sides, but a more mature bone was present in the RS. Human DNA was polymerase chain reaction-amplified only at the RS, indicating that this new bone had human cells. The us e of hDPSC in NIS rats did not cause any graft. rejection. Our findings suggest that hDPSC is an additional cell resource for correcting large cranial defects in rats and constitutes a promising model for reconstruction of human large cranial defects in craniofacial surgery.
Resumo:
An important consideration in the development of mathematical models for dynamic simulation, is the identification of the appropriate mathematical structure. By building models with an efficient structure which is devoid of redundancy, it is possible to create simple, accurate and functional models. This leads not only to efficient simulation, but to a deeper understanding of the important dynamic relationships within the process. In this paper, a method is proposed for systematic model development for startup and shutdown simulation which is based on the identification of the essential process structure. The key tool in this analysis is the method of nonlinear perturbations for structural identification and model reduction. Starting from a detailed mathematical process description both singular and regular structural perturbations are detected. These techniques are then used to give insight into the system structure and where appropriate to eliminate superfluous model equations or reduce them to other forms. This process retains the ability to interpret the reduced order model in terms of the physico-chemical phenomena. Using this model reduction technique it is possible to attribute observable dynamics to particular unit operations within the process. This relationship then highlights the unit operations which must be accurately modelled in order to develop a robust plant model. The technique generates detailed insight into the dynamic structure of the models providing a basis for system re-design and dynamic analysis. The technique is illustrated on the modelling for an evaporator startup. Copyright (C) 1996 Elsevier Science Ltd
Resumo:
Purlin-sheeting systems used for roofs and walls commonly take the form of cold-formed channel or zed section purlins, screw-connected to corrugated sheeting. These purlin-sheeting systems have been the subject of numerous theoretical and experimental investigations over the past three decades, but the complexity of the systems has led to great difficulty in developing a sound and general model. This paper presents a non-linear elasto-plastic finite element model, capable of predicting the behaviour of purlin-sheeting systems without the need for either experimental input or over simplifying assumptions. The model incorporates both the sheeting and the purlin, and is able to account for cross-sectional distortion of the purlin, the flexural and membrane restraining effects of the sheeting, and failure of the purlin by local buckling or yielding. The validity of the model is shown by its good correlation with experimental results. A simplified version of this model, which is more suitable for use in a design environment, is presented in a companion paper. (C) 1997 Elsevier Science Ltd.
Wavelet correlation between subjects: A time-scale data driven analysis for brain mapping using fMRI
Resumo:
Functional magnetic resonance imaging (fMRI) based on BOLD signal has been used to indirectly measure the local neural activity induced by cognitive tasks or stimulation. Most fMRI data analysis is carried out using the general linear model (GLM), a statistical approach which predicts the changes in the observed BOLD response based on an expected hemodynamic response function (HRF). In cases when the task is cognitively complex or in cases of diseases, variations in shape and/or delay may reduce the reliability of results. A novel exploratory method using fMRI data, which attempts to discriminate between neurophysiological signals induced by the stimulation protocol from artifacts or other confounding factors, is introduced in this paper. This new method is based on the fusion between correlation analysis and the discrete wavelet transform, to identify similarities in the time course of the BOLD signal in a group of volunteers. We illustrate the usefulness of this approach by analyzing fMRI data from normal subjects presented with standardized human face pictures expressing different degrees of sadness. The results show that the proposed wavelet correlation analysis has greater statistical power than conventional GLM or time domain intersubject correlation analysis. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Objective: To develop an animal model of endometrial ablation, and to evaluate the histologic effects of trichloroacetic acid (TCA) in the uterine cavity. Design: Experimental prospective. Setting: Department of gynecology. Patient(s): Thirty female adult rats. Intervention(s): Animals were submitted to injection of TCA in one uterine horn and saline solution in the other. Group 1 was sacrificed the day after the procedure. Group 2 was sacrificed in phase of diestrus. Superficial epithelia of the endometrium, stromal thickness, endometrial glands, and myometrium thickness were compared among the uterine horns of the same rats of group 1. The same evaluation was performed in group 2. Endometrial regeneration was evaluated. Main Outcome Measure(s): Histologic effects. Result(s): In group 1, histologic parameters showed endometrial destruction on TCA injected uterine horn. In group 2, four rats died after the procedure, and six rats had no viable material. In the rest of the group, TCA-injected uterine horns showed endometrial destruction. Superficial epithelia of the endometrium and stromal thickness were similar between TCA uterine horn from groups. However, the number of endometrial glands was higher in group 1. Conclusion(s): The study developed an experimental model for endometrial ablation. TCA acid is a potent agent for endometrial ablation in rat model. No endometrial regeneration was observed after recovery of cycle. (Fertil Steril (R) 2011; 95: 2418-21. (C) 2011 by American Society for Reproductive Medicine.)
Resumo:
Objective: To analyze the antiangiogenic effects of the selective cyclooxygenase-2 (COX-2) inhibitor parecoxib on the growth of endometrial implants in a rat model of peritoneal endometriosis. Design: Pharmacologic interventions in an experimental model of peritoneal endometriosis. Setting: Research laboratory in the Federal University of Rio de Janeiro. Animal(s): Twenty female Sprague-Dawley rats with experimentally induced endometriosis. Intervention(s): After implantation and establishment of autologous endometrium onto the peritoneum abdominal wall, rats were randomized into groups and treated with parecoxib or the vehicle by IM injection for 30 days. Main Outcome Measure(s): Vascular density, the expression of vascular endothelial growth factor (VEGF) and its receptor Flk-1, the distribution of activated macrophages, the expression of COX-2, and the prostaglandin concentration in the endometriotic lesions treated with parecoxib were analyzed. Result(s): The treatment significantly decreased the implant size, and histologic examination indicated mostly atrophy and regression. A reduction in microvessel density and in the number of macrophages, associated with decreased expression of VEGF and Flk-1, also were observed. The treatment group showed a low concentration of prostaglandin E(2). Conclusion(s): These results suggest that the use of COX-2 selective inhibitors could be effective to suppress the establishment and growth of endometriosis, partially through their antiangiogenic activity. (Fertil Steril (R) 2010; 93: 2674-9. (C) 2010 by American Society for Reproductive Medicine.)
Resumo:
Objective: To examine the effects of two commercial media on the development of mouse ova fertilized in vitro to the blastocyst stage. Design: Animal model. Setting: Academic institution. Animal(s): Eight-week old, superovulated mice. Intervention(s): One-cell embryos cultured in vitro up to the blastocyst stage in potassium-enriched simplex optimized medium (KSOM) or G1/G2 medium. Main Outcome Measure(s): Blastocyst and hatching rates, total cell number count, and proportion of allocation of cells to the inner cell mass (ICM) and trophectoderm (TE). Result(s): The percentage of zygotes that developed to the blastocyst stage 96 and 120 hours after insemination was statistically significantly higher in the KSOM group. The percentage of blastocysts that partially or completely hatched by day 5 of culture was 84% and 71% for the KSOM and G1/G2 groups, respectively, showing a statistically significant difference between the groups. The mean number of ICM cells was 11.7 +/- 4.0 and 9.2 +/- 5.2 for the zygotes cultured in KSOM and G1/G2 media, respectively, revealing a statistically significantly higher cell number in the ICM of blastocysts derived from culture in KSOM medium. The ICM/TE ratio in the blastocysts cultured in KSOM or G1/G2 media was similar in both groups. Conclusion(s): Commercially available KSOM medium is superior to sequential G1/G2 media for culturing one-cell embryos up to the blastocyst stage in the mouse IVF model.
Resumo:
Experimental models of infection are good tools for establishing immunological parameters that have an effect on the host-pathogen relationship and also for designing new vaccines and immune therapies. In this work, we evaluated the evolution of experimental tuberculosis in mice infected with increasing bacterial doses or via distinct routes. We showed that mice infected with low bacterial doses by the intratracheal route were able to develop a progressive infection that was proportional to the inoculum size. In the initial phase of disease, mice developed a specific Th1-driven immune response independent of inoculum concentration. However, in the late phase, mice infected with higher concentrations exhibited a mixed Th1/Th2 response, while mice infected with lower concentrations sustained the Th1 pattern. Significant IL-10 concentrations and a more preeminent T regulatory cell recruitment were also detected at 70 days post-infection with high bacterial doses. These results suggest that mice infected with higher concentrations of bacilli developed an immune response similar to the pattern described for human tuberculosis wherein patients with progressive tuberculosis exhibit a down modulation of IFN-gamma production accompanied by increased levels of IL-4. Thus, these data indicate that the experimental model is important in evaluating the protective efficacy of new vaccines and therapies against tuberculosis. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
OBJECTIVE: Investigate the effects of antenatal steroids and tracheal occlusion on pulmonary expression of vascular endothelial growth factor receptors in rats with nitrofen-induced congenital diaphragmatic hernia. STUDY DESIGN: Fetuses were exposed to nitrofen at embryonic day 9.5. Subgroups received dexamethasone or were operated on for tracheal occlusion, or received combined treatment. Morphologic variables were recorded. To analyze vascular endothelial growth factor receptor 1 and vascular endothelial growth factor receptor 2 expression, we performed Western blotting and immunohistochemistry. Morphologic variables were analyzed by analysis of variance and immunohistochemistry by Kruskal-Wallis test. RESULTS: Congenital diaphragmatic hernia decreased body weight, total lung weight, and lung-to-body weight ratio. Tracheal occlusion increased total lung weight and lung-to-body weight ratio (P < .05). Fetuses with congenital diaphragmatic hernia had reduced vascular endothelial growth factor receptor 1 and vascular endothelial growth factor receptor 2 expression, whereas steroids and tracheal occlusion increased their expression. Combined treatment increased expression of receptors, but had no additive effect. CONCLUSION: Vascular endothelial growth factor signaling disruption may be associated with pulmonary hypertension in congenital diaphragmatic hernia. Tracheal occlusion and steroids provide a pathway for restoring expression of vascular endothelial growth factor receptors.
Resumo:
Background: There is only limited knowledge on how the quantification of valvular regurgitation by color Doppler is affected by changing blood viscosity. This study was designed to evaluate the effect of changing blood viscosity on the vena contracta width using an in vitro model of valvular insufficiency capable of providing ample variation in the rate and stroke volume. Methods: We constructed a pulsatile flow model filled with human blood at varying hematocrit (15%, 35%, and 55%) and corresponding blood viscosity (blood/water viscosity: 2.6, 4.8, 9.1) levels in which jets were driven through a known orifice (7 mm(2)) into a 110 mL compliant receiving chamber (compliance: 2.2 mL/mmHg) by a pulsatile pump. In addition, we used variable pump stroke volumes (5, 7.5, and 10 mL) and rates (40, 60, and 80 ppm). Vena contracta region was imaged using a 3.5 MHz transducer. Pressure and volume in the flow model were kept constant during each experimental condition, as well as ultrasound settings. Results: Blood viscosity variation in the experimental range did not induce significant changes in vena contracta dimensions. Also, vena contracta width did not change from normal to low hematocrit and viscosity levels. A very modest increase only in vena contracta dimension was observed at very high level of blood viscosity when hematocrit was set to 55% . Pump rate, in the evaluated range, did not influence vena contracta width. These results in controlled experimental settings suggest that the vena contracta is an accurate quantitative method for quantifying valvular regurgitation even when this condition is associated with anemia, a frequent finding in patients with valvular heart disease.
Resumo:
The relationship between the ordering characteristic of the pyrochlore structure type and that characteristic of the defect fluorite structure type (immediately on either side of two phase regions separating the two structure types) in a range of rare eath sesquioxide stabilized cubic zirconias is investigated via electron diffraction and imaging. Systematic structural change as a function of composition and relative size of the constituent metal ions is highlighted and a multi-q to single-q = 1/2 [111]* model proposed for the observed pyrochlore to defect fluorite phase transition. Strain introduced into the close-packed {111} metal ion planes of the defect fluorite average structure by the local cation and oxygen vacancy distribution is pointed to as the likely origin of the observed behavior. (C) 2001 Academic Press
Resumo:
There are many methods for the analysis and design of embedded cantilever retaining walls. They involve various different simplifications of the pressure distribution to allow calculation of the limiting equilibrium retained height and the bending moment when the retained height is less than the limiting equilibrium value, i.e. the serviceability case. Recently, a new method for determining the serviceability earth pressure and bending moment has been proposed. This method makes an assumption defining the point of zero net pressure. This assumption implies that the passive pressure is not fully mobilised immediately below the excavation level. The finite element analyses presented in this paper examine the net pressure distribution on walls in which the retained height is less, than the limiting equilibrium value. The study shows that for all practical walls, the earth pressure distributions on the front and back of the wall are at their limit values, Kp and K-a respectively, when the lumped factor of safety F-r is less than or equal to2.0. A rectilinear net pressure distribution is proposed that is intuitively logical. It produces good predictions of the complete bending moment diagram for walls in the service configuration and the proposed method gives results that have excellent agreement with centrifuge model tests. The study shows that the method for determining the serviceability bending moment suggested by Padfield and Mair(1) in the CIRIA Report 104 gives excellent predictions of the maximum bending moment in practical cantilever walls. It provides the missing data that have been needed to verify and justify the CIRIA 104 method.
Resumo:
Bond's method for ball mill scale-up only gives the mill power draw for a given duty. This method is incompatible with computer modelling and simulation techniques. It might not be applicable for the design of fine grinding ball mills and ball mills preceded by autogenous and semi-autogenous grinding mills. Model-based ball mill scale-up methods have not been validated using a wide range of full-scale circuit data. Their accuracy is therefore questionable. Some of these methods also need expensive pilot testing. A new ball mill scale-up procedure is developed which does not have these limitations. This procedure uses data from two laboratory tests to determine the parameters of a ball mill model. A set of scale-up criteria then scales-up these parameters. The procedure uses the scaled-up parameters to simulate the steady state performance of full-scale mill circuits. At the end of the simulation, the scale-up procedure gives the size distribution, the volumetric flowrate and the mass flowrate of all the streams in the circuit, and the mill power draw.