968 resultados para Medical procedures
Resumo:
A low-profile wearable antenna suitable for integration into low-cost, disposable medical vital signs monitors is presented. Simulated and measured antenna performance was characterized on a layered human tissue phantom, representative of the thorax region of a range of human bodies. The wearable antenna has sufficient bandwidth for the 868 MHz Industrial, Scientific and Medical frequency band. Wearable radiation efficiency of up to 30 % is reported when mounted in close proximity to the novel human tissue phantom antenna test-bed at 868 MHz.
Resumo:
Data registration refers to a series of techniques for matching or bringing similar objects or datasets together into alignment. These techniques enjoy widespread use in a diverse variety of applications, such as video coding, tracking, object and face detection and recognition, surveillance and satellite imaging, medical image analysis and structure from motion. Registration methods are as numerous as their manifold uses, from pixel level and block or feature based methods to Fourier domain methods.
This book is focused on providing algorithms and image and video techniques for registration and quality performance metrics. The authors provide various assessment metrics for measuring registration quality alongside analyses of registration techniques, introducing and explaining both familiar and state-of-the-art registration methodologies used in a variety of targeted applications.
Key features:
- Provides a state-of-the-art review of image and video registration techniques, allowing readers to develop an understanding of how well the techniques perform by using specific quality assessment criteria
- Addresses a range of applications from familiar image and video processing domains to satellite and medical imaging among others, enabling readers to discover novel methodologies with utility in their own research
- Discusses quality evaluation metrics for each application domain with an interdisciplinary approach from different research perspectives
Resumo:
The use of biosensors attached to the body for health monitoring is now readily accepted, and the merits of such systems and their potential impact on healthcare receive much attention. Wearable medical systems used in clinical applications to monitor vital signs must be comfortable to wear, yet have robust performance to ensure reliable communications links. Additionally, and vital to the success of these innovations, is that these solutions are disposable to avoid risk of patient infection and this means that they must be ultra-low cost. Antennas optimized for printing using conductive inks offer new exciting advances in making a truly disposable solution.
Resumo:
Purpose: To determine differences in overall tumor responses measured by volumetric assessment and bioluminescence imaging (BLI) following exposure to uniform and non-uniform radiation fields in an ectopic prostate tumor model.
Materials and methods: Bioluminescent human prostate tumor xenografts were established by subcutaneous implantation into male mice. Tumors were irradiated with uniform or non-uniform field configurations using conventional in vivo irradiation procedures performed using a 225 kVp generator with custom lead shielding. Tumor responses were measured using Vernier calipers and by BLI using an in vivo imaging system. Survival was defined as the time to quadroupling of pre-treatment tumor volume.
Results: The correlation between BLI and tumor volume measurements was found to be different for un-irradiated (R = 0.61), uniformly irradiated (R = 0.34) and partially irradiated (R = 0.30) tumors. Uniformly irradiated tumors resulted in an average tumor growth delay of 60 days with median survival of 75 days, compared to partially irradiated tumors which showed an average growth delay of 24 days and median survival of 38 days.
Conclusions: Correlation between BLI and tumor volume measurements is lower for partially irradiated tumors than those exposed to uniform dose distributions. The response of partially irradiated tumors suggests non-uniformity in response beyond physical dose distribution within the target volume. Dosimetric uncertainty associated with conventional in vivo irradiation procedures prohibits their ability to accurately determine tumor response to non-uniform radiation fields and stresses the need for image guided small animal radiation research platforms.
Resumo:
BACKGROUND AND OBJECTIVE: Human research ethics committees provide essential review of research projects to ensure the ethical conduct of human research. Several recent reports have highlighted a complex process for successful application for human research ethics committee approval, particularly for multi-centre studies. Limited resources are available for the execution of human clinical research in Australia and around the world.
METHODS: This report overviews the process of ethics approval for a National Health and Medical Research Council-funded multi-centre study in Australia, focussing on the time and resource implications of such applications in 2007 and 2008.
RESULTS: Applications were submitted to 16 hospital and two university human research ethics committees. The total time to gain final approval from each committee ranged between 13 and 77 days (median = 46 days); the entire process took 16 months to complete and the research officer's time was estimated to cost $A34 143.
CONCLUSIONS: Obstacles to timely human research ethics committee approval are reviewed, including recent, planned and potential initiatives that could improve the ethics approval of multi-centre research.
Resumo:
PURPOSE: Arteriovenous fistulae (AVFs) are the preferred option for vascular access, as they are associated with lower mortality in hemodialysis patients than in those patients with arteriovenous grafts (AVGs) or central venous catheters (CVCs). We sought to assess whether vascular access outcomes for surgical trainees are comparable to fully trained surgeons.
METHODS: A prospectively collected database of patients was created and information recorded regarding patient demographics, past medical history, preoperative investigations, grade of operating surgeon, type of AVF formed, primary AVF function, cumulative AVF survival and functional patency.
RESULTS: One hundred and sixty-two patients were identified as having had vascular access procedures during the 6 month study period and 143 were included in the final analysis. Secondary AVF patency was established in 123 (86%) of these AVFs and 89 (62.2%) were used for dialysis. There was no significant difference in survival of AVFs according to training status of surgeon (log rank x2 0.506 p=0.477) or type of AVF (log rank x2 0.341 p=0.559). Patency rates of successful AVFs at 1 and 2 years were 60.9% and 47.9%, respectively.
CONCLUSION: We have demonstrated in this prospective study that there are no significant differences in outcomes of primary AVFs formed by fully trained surgeons versus surgical trainees. Creation of a primary AVF represents an excellent training platform for intermediate stage surgeons across general and vascular surgical specialties.
Resumo:
Bioresorbable polymers such as PLA have an important role to play in the development of temporary implantable medical devices with significant benefits over traditional therapies. However, development of new devices is hindered by high manufacturing costs associated with difficulties in processing the material. A major problem is the lack of insight on material degradation during processing. In this work, a method of quantifying degradation of PLA using IR spectroscopy coupled with computational chemistry and chemometric modeling is examined. It is shown that the method can predict the quantity of degradation products in solid-state samples with reasonably good accuracy, indicating the potential to adapt the method to developing an on-line sensor for monitoring PLA degradation in real-time during processing.
Resumo:
Punctal plugs (PPs) are miniature medical implants that were initially developed for the treatment of dry eyes. Since their introduction in 1975, many PPs made from different materials and designs have been developed. PPs, albeit generally successful, suffer from drawbacks such as epiphora and suppurative canaliculitis. To overcome these issues intelligent designs of PPs were proposed (e.g. SmartPLUG™ and Form Fit™). PPs are also gaining interest among pharmaceutical scientists for sustaining drug delivery to the eye. This review aims to provide an overview of PPs for dry eye treatment and drug delivery to treat a range of ocular diseases. It also discusses current challenges in using PPs for ocular diseases.