952 resultados para Materials testing laboratories
Resumo:
The common goal of tissue engineering is to develop substitutes that can closely mimic the structure of extracellular matrix (ECM). However, similarly important is the intensive material properties which have often been overlooked, in particular, for soft tissues that are not to bear load assumingly. The mechanostructural properties determine not only the structural stability of biomaterials but also their physiological functionality by directing cellular activity and regulating cell fate decision. The aim here is to emphasize that cells could sense intensive material properties like elasticity and reside, proliferate, migrate and differentiate accordinglyno matter if the construct is from a natural source like cartilage, skin etc. or of synthetic one. Meanwhile, the very objective of this work is to provide a tunable scheme for manipulating the elasticity of collagen-based constructs to be used to demonstrate how to engineer cell behavior and regulate mechanotransduction. Articular cartilage was chosen as it represents one of the most complex hierarchical arrangements of collagen meshwork in both connective tissues and ECM-like biomaterials. Corona discharge treatment was used to produce constructs with varying density of crosslinked collagen and stiffness accordingly. The results demonstrated that elastic modulus increased up to 33% for samples treated up to one minute as crosslink density was found to increase with exposure time. According to the thermal analysis, longer exposure to corona increased crosslink density as the denaturation enthalpy increased. However the spectroscopy results suggested that despite the stabilization of the collagen structure the integrity of the triple helical structure remained intact. The in vitro superficial culture of heterologous chondrocytes also determined that the corona treatment can modulate migration with increased focal adhesion of cells due to enhanced stiffness, without cytotoxicity effects, and providing the basis for reinforcing three-dimensional collagen-based biomaterials in order to direct cell function and mediate mechanotransduction.
Resumo:
Computer generated materials are ubiquitous and we encounter them on a daily basis, even though most people are unaware that this is the case. Blockbuster movies, television weather reports and telephone directories all include material that is produced by utilising computer technologies. Copyright protection for materials generated by a programmed computer was considered by the Federal Court and Full Court of the Federal Court in Telstra Corporation Limited v Phone Directories Company Pty Ltd. The court held that the White and Yellow pages telephone directories produced by Telstra and its subsidiary, Sensis, were not protected by copyright because they were computer-generated works which lacked the requisite human authorship. The Copyright Act 1968 (Cth) does not contain specific provisions on the subsistence of copyright in computer-generated materials. Although the issue of copyright protection for computer-generated materials has been examined in Australia on two separate occasions by independently-constituted Copyright Law Review Committees over a period of 10 years (1988 to 1998), the Committees’ recommendations for legislative clarification by the enactment of specific amendments to the Copyright Act have not yet been implemented and the legal position remains unclear. In the light of the decision of the Full Federal Court in Telstra v Phone Directories it is timely to consider whether specific provisions should be enacted to clarify the position of computer-generated works under copyright law and, in particular, whether the requirement of human authorship for original works protected under Part III of the Copyright Act should now be reconceptualised to align with the realities of how copyright materials are created in the digital era.
Resumo:
Cyclostationary models for the diagnostic signals measured on faulty rotating machineries have proved to be successful in many laboratory tests and industrial applications. The squared envelope spectrum has been pointed out as the most efficient indicator for the assessment of second order cyclostationary symptoms of damages, which are typical, for instance, of rolling element bearing faults. In an attempt to foster the spread of rotating machinery diagnostics, the current trend in the field is to reach higher levels of automation of the condition monitoring systems. For this purpose, statistical tests for the presence of cyclostationarity have been proposed during the last years. The statistical thresholds proposed in the past for the identification of cyclostationary components have been obtained under the hypothesis of having a white noise signal when the component is healthy. This need, coupled with the non-white nature of the real signals implies the necessity of pre-whitening or filtering the signal in optimal narrow-bands, increasing the complexity of the algorithm and the risk of losing diagnostic information or introducing biases on the result. In this paper, the authors introduce an original analytical derivation of the statistical tests for cyclostationarity in the squared envelope spectrum, dropping the hypothesis of white noise from the beginning. The effect of first order and second order cyclostationary components on the distribution of the squared envelope spectrum will be quantified and the effectiveness of the newly proposed threshold verified, providing a sound theoretical basis and a practical starting point for efficient automated diagnostics of machine components such as rolling element bearings. The analytical results will be verified by means of numerical simulations and by using experimental vibration data of rolling element bearings.
Resumo:
This paper investigates the potential of pulsed power to sterilize hard and soft tissues and its impact on their physico-mechanical properties. It hypothesizes that pulsed plasma can sterilize both vascular and avascular tissues and the transitive layers in between without deleterious effects on their functional characteristics. Cartilage/bone laminate was chosen as a model to demonstrate the concept, treated at low temperature, at atmospheric pressure, in short durations and in buffered environment using a purposed-built pulsed power unit. Input voltage and time of exposure were assigned as controlling parameters in a full factorial design of experiment to determine physical and mechanical alteration pre- and post-treatment. The results demonstrated that, discharges of 11 kV sterilized samples in 45 s, reducing intrinsic elastic modules from 1.4 ± 0.9 to 0.9 ± 0.6 MPa. There was a decrease of 14.1 % in stiffness and 27.8 % in elastic-strain energy for the top quartile. Mechanical impairment was directly proportional to input voltage (P value < 0.05). Bacterial inactivation was proportional to treatment time for input voltages above 32 V (P < 0.001; R Sq = 0.98). Thermal analysis revealed that helix-coil transition decelerated with exposure time and collagen fibrils were destabilized as denaturation enthalpy reduced by 200 μV. We concluded by presenting a safe operating threshold for pulsed power plasma as a feasible protocol for effective sterilization of connective tissues with varying level of loss in mechanical robustness which we argue to be acceptable in certain medical and tissue engineering application.
Resumo:
Bone, a hard biological material, possesses a combination of high stiffness and toughness, even though the main basic building blocks of bone are simply mineral platelets and protein molecules. Bone has a very complex microstructure with at least seven hierachical levels. This unique material characteristic attracts great attention, but the deformation mechanisms in bone have not been well understood. Simulation at nano-length scale such as molecular dynamics (MD) is proven to be a powerful tool to investigate bone nanomechanics for developing new artificial biological materials. This study focuses on the ultra large and thin layer of extrafibrillar protein matrix (thickness = ~ 1 nm) located between mineralized collagen fibrils (MCF). Non-collagenous proteins such as osteopontin (OPN) can be found in this protein matrix, while MCF consists mainly of hydroxyapatite (HA) nanoplatelets (thickness = 1.5 – 4.5 nm). By using molecular dynamics method, an OPN peptide was pulled between two HA mineral platelets with water in presence. Periodic boundary condition (PBC) was applied. The results indicate that the mechanical response of OPN peptide greatly depends on the attractive electrostatics interaction between the acidic residues in OPN peptide and HA mineral surfaces. These bonds restrict the movement of OPN peptide, leading to a high energy dissipation under shear loading.
Resumo:
The objective of this study was to test for the measurement invariance of the Attention and Thought Problems subscales of the Child Behavior Checklist (CBCL) and Youth Self-Report (YSR) in a population-based sample of adolescents with and without epilepsy. Data were obtained from the 14-year follow-up of the Mater University Study of Pregnancy in which 33 adolescents with epilepsy and 1068 healthy controls were included for analysis. Confirmatory factor analysis was used to test for measurement invariance between adolescents with and without epilepsy. Structural equation modeling was used to test for group differences in attention and thought problems as measured with the CBCL and YSR. Measurement invariance was demonstrated for the original CBCL Attention Problems and YSR Thought Problems. After the removal of ambiguous items (“confused” and “daydreams”),measurement invariance was established for the YSR Attention Problems. The original and reduced CBCL Thought Problems were noninvariant. Adolescents with epilepsy had significantly more symptoms of behavioral problems on the CBCL Attention Problems, β = 0.51, p = 0.002, compared with healthy controls. In contrast, no significant differences were found for the YSR Attention and Thought Problems, β = −0.11, p = 0.417 and β = −0.20, p = 0.116, respectively. In this population-based sample of adolescents with epilepsy, the CBCL Attention Problems and YSR Thought Problems appear to be valid measures of behavioral problems, whereas the YSR Attention Problems was valid only after the removal of ambiguous items. Replication of these findings in clinical samples of adolescents with epilepsy that overcome the limitations of the current study is warranted.
Resumo:
Bone defect treatments can be augmented by mesenchymal stem cell (MSC) based therapies. MSC interaction with the extracellular matrix (ECM) of the surrounding tissue regulates their functional behavior. Understanding of these specific regulatory mechanisms is essential for the therapeutic stimulation of MSC in vivo. However, these interactions are presently only partially understood. This study examined in parallel, for the first time, the effects on the functional behavior of MSCs of 13 ECM components from bone, cartilage and hematoma compared to a control protein, and hence draws conclusions for rational biomaterial design. ECM components specifically modulated MSC adhesion, migration, proliferation, and osteogenic differentiation, for example, fibronectin facilitated migration, adhesion, and proliferation, but not osteogenic differentiation, whereas fibrinogen enhanced adhesion and proliferation, but not migration. Subsequently, the integrin expression pattern of MSCs was determined and related to the cell behavior on specific ECM components. Finally, on this basis, peptide sequences are reported for the potential stimulation of MSC functions. Based on the results of this study, ECM component coatings could be designed to specifically guide cell functions.
Resumo:
This project advances the knowledge of rail wear and crack formation due to rail/wheel contact in Australian heavy-haul railway lines. This comprehensive study utilised numerous techniques including: simulation using a twin-disk test-rig, scanning electron microscope particle analysis and finite element modeling for material failure prediction. Through this work, new material failure models have been developed which may be used to predict the lifetime and reliability of materials undergoing severe contact conditions.
Resumo:
Purpose The aim of this study is to assess the refractive and visual outcomes following cataract surgery and implantation of the AcrySof IQ Toric SN6AT2 intraolcular lens (IOL) (Alcon Laboratories, Inc) in patients with low corneal astigmatism. Materials and Methods A retrospective, consecutive, single surgeon series of ninety-eight eyes of 88 patients following cataract surgery and implantation of the AcrySof IQ Toric SN6AT2 IOL in eyes with low preoperative corneal astigmatism. Postoperative measurements were obtained at one month post surgery. Main outcome measures were monocular distance visual acuity and residual refractive astigmatism. Results The mean preoperative corneal astigmatic power vector (APV) was 0.38 ± 0.09 D. Following surgery and implantation of the toric IOL, mean postoperative refractive APV was 0.13 ± 0.10 D. Mean postoperative distance uncorrected visual acuity (UCVA) was 0.08 ± 0.09 logMAR. Postoperative spherical equivalent refraction (SER) resulted in a mean of - 0.23 ± 0.22 D, with 96% of eyes falling within 0.50 D of the target SER. Conclusions The AcrySof IQ Toric SN6AT2 IOL is a safe and effective option for eyes undergoing cataract surgery with low amounts of preoperative corneal astigmatism.
Resumo:
Rigid lenses, which were originally made from glass (between 1888 and 1940) and later from polymethyl methacrylate or silicone acrylate materials, are uncomfortable to wear and are now seldom fitted to new patients. Contact lenses became a popular mode of ophthalmic refractive error correction following the discovery of the first hydrogel material – hydroxyethyl methacrylate – by Czech chemist Otto Wichterle in 1960. To satisfy the requirements for ocular biocompatibility, contact lenses must be transparent and optically stable (for clear vision), have a low elastic modulus (for good comfort), have a hydrophilic surface (for good wettability), and be permeable to certain metabolites, especially oxygen, to allow for normal corneal metabolism and respiration during lens wear. A major breakthrough in respect of the last of these requirements was the development of silicone hydrogel soft lenses in 1999 and techniques for making the surface hydrophilic. The vast majority of contact lenses distributed worldwide are mass-produced using cast molding, although spin casting is also used. These advanced mass-production techniques have facilitated the frequent disposal of contact lenses, leading to improvements in ocular health and fewer complications. More than one-third of all soft contact lenses sold today are designed to be discarded daily (i.e., ‘daily disposable’ lenses).
Resumo:
"The success of Criminal Laws lies both in its distinctive features and in its appeal to a range of readerships. As one review put it, it is simultaneously a "textbook, casebook, handbook and reference work". As such it is ideal for criminal law and criminal justice courses as a teaching text, combining as it does primary sources with extensive critical commentary and a contextual perspective. It is likewise indispensable to practitioners for its detailed coverage of substantive law and its extensive references and inter-disciplinary approach make it a first point of call for researchers from all disciplines. This fifth edition strengthens these distinctive features. All chapters have been systematically updated to incorporate the plethora of legislative, case law, statistical and research material which has emerged since the previous edition. The critical, thematic, contextual and interdisciplinary perspectives have been continued."--Publisher's website. Table of Contents: 1. Some themes -- 2. Criminalisation -- 3. The criminal process -- 4. Components of criminal offences -- 5. Homicide: murder and involuntary manslaughter -- 6. Defences -- 7. Assault and sexual assault -- 8. Public order offences -- 9. Drugs offences -- 10. Dishonest acquisition -- 11. Extending criminal liability: complicity, conspiracy and association -- 12. Sentencing and penality.
Resumo:
Background Drink driving among women is a growing problem in many motorised countries. While research has shown that male and female drink drivers differ on a number of characteristics, few studies have addressed the circumstances surrounding women’s drink driving offences specifically. Aim To add to previous research by comparing apprehension characteristics among men and women and to extend the understanding of the female drink driving problem by investigating the drink driving characteristics that are unique to women. Results The sample consisted of the 248,173 (21.5% women) drink drivers apprehended between 2000 and 2011 in Queensland, Australia. Gender comparisons showed that women were older, had lower levels of reoffending, and were more likely to be apprehended in Major Cities compared to men. Comparisons of age group and reoffending and non-reoffending among female drink drivers only revealed that higher BAC readings were more common among younger women. Moreover, a substantial minority (13.7%) of women aged 24 years or younger were apprehended with a BAC below0.05%, reflecting a breach of the zero tolerance BAC for provisional licence holders in Australia. Older women were more likely to be charged with a ‘failure to provide a test’ offence as a result of refusing to provide a breath or blood sample, indicating that drink driving is associated high levels of stigma for this group. Reoffending occurred among 16.2% of the female drink drivers and these drivers were more likely than non-reoffending drivers to record a mid to high range BAC, to be aged 30-39 or below 21years, and to be apprehended in Inner Regional or Remote locations. Conclusion Findings highlight the unique circumstances and divergent needs of female drink drivers compared to male drivers and for different groups of female drivers.
Resumo:
Insulated rail joints (IRJs) are a primary component of the rail track safety and signalling systems. Rails are supported by two fishplates which are fastened by bolts and nuts and, with the support of sleepers and track ballast, form an integrated assembly. IRJ failure can result from progressive defects, the propagation of which is influenced by residual stresses in the rail. Residual stresses change significantly during service due to the complex deformation and damage effects associated with wheel rolling, sliding and impact. IRJ failures can occur when metal flows over the insulated rail gap (typically 6-8 mm width), breaks the electrically isolated section of track and results in malfunction of the track signalling system. In this investigation, residual stress measurements were obtained from rail-ends which had undergone controlled amounts of surface plastic deformation using a full scale wheel-on-track simulation test rig. Results were compared with those obtained from similar investigations performed on rail ends associated with ex-service IRJs. Residual stresses were measured by neutron diffraction at the Australian Nuclear Science and Technology Organisation (ANSTO). Measurements with constant gauge volume 3x3x3 mm3 were carried in the central vertical plane on 5mm thick sliced rail samples cut by an electric discharge machine (EDM). Stress evolution at the rail ends was found to exhibit characteristics similar to those of the ex-service rails, with a compressive zone of 5mm deep that is counterbalanced by a tension zone beneath, extending to a depth of around 15mm. However, in contrast to the ex-service rails, the type of stress distribution in the test-rig deformed samples was apparently different due to the localization of load under the particular test conditions. In the latter, in contrast with clear stress evolution, there was no obvious evolution of d0. Since d0 reflects rather long-term accumulation of crystal lattice damage and microstructural changes due to service load, the loading history of the test rig samples has not reached the same level as the ex-service rails. It is concluded that the wheel-on-rail simulation rig provides the potential capability for testing the wheel-rail rolling contact conditions in rails, rail ends and insulated rail joints.
Resumo:
We present a pole inspection system for outdoor environments comprising a high-speed camera on a vertical take-off and landing (VTOL) aerial platform. The pole inspection task requires a vehicle to fly close to a structure while maintaining a fixed stand-off distance from it. Typical GPS errors make GPS-based navigation unsuitable for this task however. When flying outdoors a vehicle is also affected by aerodynamics disturbances such as wind gusts, so the onboard controller must be robust to these disturbances in order to maintain the stand-off distance. Two problems must therefor be addressed: fast and accurate state estimation without GPS, and the design of a robust controller. We resolve these problems by a) performing visual + inertial relative state estimation and b) using a robust line tracker and a nested controller design. Our state estimation exploits high-speed camera images (100Hz) and 70Hz IMU data fused in an Extended Kalman Filter (EKF). We demonstrate results from outdoor experiments for pole-relative hovering, and pole circumnavigation where the operator provides only yaw commands. Lastly, we show results for image-based 3D reconstruction and texture mapping of a pole to demonstrate the usefulness for inspection tasks.