999 resultados para Lodo de esgoto - Toxicologia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Natal still dominates the use of individual disposal systems for domestic sewage, once only 29% of the city has a sewarage system. Wastes that are accumulated in these individual treatment systems should be exhausted periodically, service provided by collector entrepreneurs. Some of these companies causing major damage to the environment. In Natal, only two companies have their own septage (RESTI) treatment system, which were designed with parameters from domestic sewage generating strain and inefficient systems. Therefore, the characterization becomes essential as a source of parameters for their design. Thus, this work presents the physical-chemical and microbiological characterization of waste pumped from individual sewage treatment systems. Samples collections were made weekly from 5 different trucks at the reception point on the treatment plant on the point of the preliminary treatment. From each truck it was taken 5 samples during the discharge in order to make a composite sample. Afterwards, samples were carried out to laboratory and analyses for determination of temperature, pH, conductivity, BOD, COD, nitrogen (ammonia e organic), alkalinity, oils, phosphorus, solids, faecal coliforms and helminth egg. The results were treated as a single database, and ranked according to its generating source (multi and single house, lodging, health, services and / or food), area of origin (metropolitan, south and north) and type of system (cesspits, septic tank and / or sink). Through these data it was possible to verify that the type of system adopted by most in Natal and the metropolitan region is cesspit, besides to confirm the difference between the septage of areas with a population have different social and economical characteristics. It was found that the septage have higher concentrations than domestic sewage, except for thermotolerant coliforms that showed concentrations of 1,38E+07. Among the parameters studied, is the median values identified for COD (3,549 mg / L), BOD (973mg / L) and total solids (3.557mg / L). The volatile fraction constitutes about 70% of the total solids of the septage. For helminths has been a median of 7 eggs/L. In general, the characteristics of the waste followed the variability found in the literature reviewed for all variables, showing high amplitudes

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Because of disability in public policy development in mind to attend issues of sanitation in the municipalities, companies known as "clean-blue" appeared proposing to solve a simple collection and management of wastewater produced in single or multifamily residences, commercial, hospitals, etc. In the case of an activity in which there are no worries about the fate of sewage, emerged some doubts about the degree of health and environmental safety in these companies. Traditionally, most of them makes the provision of waste depleted soil or wetland, open, usually located on the outskirts of cities (MENESES, 2001). In turn, the sludge from septic tanks exhausted, provided no technical criteria - in the soil, rivers and as an agricultural fertilizer put in risk the health of the population and environmental quality. This work was entered in the search network 5 of the Notice of the Research Program in Sanitation - PROSAB-5, aimed to study the theme 'Characterization and study of alternative ways of treating sludge from septic tanks in the city of Natal, RN', proposing to evaluate the performance of the use of stabilization ponds as a system to handle waste from septic tanks exhausted. A series of lakes studied belong to one of the largest clean-pit of Natal, consisting of two anaerobic ponds, one facultative and maturation, and a tank disinfection, the wastewater being released in the Potengi River. Samples were collected between the months of October 2007 to October 2008, at six points previously defined and judged as more appropriate to what is proposed study. The analysis results in field and laboratory showed the most significant removal of COD (88.93%), total suspended solids (94.87%), organic nitrogen (66.87%) and thermotolerant coliforms (99.88%). Some results have not reached the expected because the system under study had operating problems that have undermined the efficiency of the reactors

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigates a new treatment system of wastewater by anaerobic and aerobic biological filters for nitrogen modification. The main objective of this study was evaluate, on a pilot scale, quantitatively and qualitatively the bacterian nitrifying community in a experimental sewage treatment system made by aerobics biological filters in series, in search of figure out the dynamic of nitrogen modification process. It was collected and laboratorial analysed microbiologically, regarding NMP of Nitrosomonas e Nitrobacter, and physical-chemically considering nitrogen sequence. We conclude that: the association in aerobic biological filters under nutrition controlled conditions and oxygen level allows the appearance of bacterian community responsible for the nitrogen modification; the method used, despite its limitations, provided the selection of autotrophic nitrifying microorganisms, allowing the identification of Nitrosomonas and Nitrobacter; the flow direction tested in the experimental unit did not affect the nitrifying bacterial community, certainly because they were kept drowned and did not occur flow speed that could breake the formed biomass; the nitrification process happened in aerated biological filters in all phases of the research, comproved by microbiological tests; in the third phase of the research the increase of the oxygen rate was significant for the nitrificant bacterian community in the aerate biological filters, allowing its growth, occurring relation between the efficiency of nitrification system and the quantity of organisms responsible for this process; the conduit used in aerated biological filters showed satisfactory performance support material to the nitrifying bacteria development

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The growing accumulation of people in urban centers caused chronic problems of the cities to begin to take an increasingly unsustainable. Primarily related to lack of infrastructure coupled with sanitation and lack of investment in critical sectors such as health, education, housing and transportation, these problems start to deteriorate markedly the quality of life of city dwellers and put into test management policies of the spaces urbanized. To reverse this situation, shows is essential to the use of tools (highlighting this harvest rates and environmental indicators) that help in assessing the current conditions and may assist in predicting future scenarios. From the information listed above, now put the research seeks to present an index called ISBA Environmental (Sanitation Index) which looks at the four urban systems (water, sewer, solid waste and urban drainage) from the viewpoint of application in a geographical cutout specific - in this case the Drainage Basin XII, defined by the Plan of Urban Drainage Stormwater in the city of Natal, capital of Rio Grande do Norte. This index, together with analysis of other factors sought to trace the current conditions of the basin and thus, assist in proposing the best solutions. For the preparation of the index was applied a questionnaire with a sample of 384 (three hundred eighty-four) households that aimed to study two variables: access to services and satisfaction of the population in relation to these. The ISBA has shown that the system is the most deficient collection and disposal of effluents (ICE = 47.66%), followed by the drainage of rainwater (IDAP = 54.17%), water supply (AAI = 61, 36) and solid waste collection (IRS = 78.28). With the ISBA was possible to verify that the qualitative data shows whose subjectivity is evident (as is the case of user satisfaction) can be of great importance when an assessment, since we obtained the correlation coefficient between the variables "Access" and " Satisfaction "equal to 0.8234, showing a strong correlation between the existence / quality of service offered and the impressions of the population that receives them

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stabilization pond is the main technology used for treatment wastewater, in northeast Brazil, due to lower cost of deployment, operation and maintenance compared to other technologies. Most systems of stabilization ponds has been in operation for some time, on average 10 years of operation, receiving high organic loads and do not have good removal efficiencies of the main parameters for which have been designed. Therefore it is necessary to work to quantify the efficiency of current systems. This study evaluated the biodegradability of organic matter in raw sewage, the removal of organic matter in reactors and determination of the kinetic constant removal of organic matter (k), both in reactors and in raw sewage, based on the analysis made in the laboratory and through mathematical methods proposed in the literature, in nine systems stabilization ponds, located in Rio Grande do Norte. In relation the degradation kinetics in stabilization ponds, it was observed that many papers published in the literature were obtained in pilot-scale systems, which often, due to the action of external factors such as wind and temperature, these can t be considered as a reference in the analysis of the kinetic constant K, so the need for more research into systems of scale. This study had three distinct phases and simultaneous, routine monitoring, study of the daily cycle and the determination of kinetic constant of degradation of organic matter (K). The monitoring showed that the removal efficiencies of organic matter on most systems were lower than suggested by the literature, the best efficiencies of around 76% (BOD) and 72% (COD) and the worst of the order of 48% (BOD) and 55% (COD). The calculation of K in raw sewage (Ke) was within the range of variation expected in the literature (0.35 to 0.60 days-1). Already for the results obtained for K in the reactors (Kr), there were well below the values recommended in the literature (0.25 to 0.40 d-1 for complete mix and from 0.13 to 0.17 d-1 for flow dispersed), in line with the overloads that organic systems are subject

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The simulation of SES-Natal Ponta Negra: mitigation of environmental risks and predictive maintenance strategy was developed in the context of several operational irregularities in the pumping stations and sewage systems in the system Ponta Negra. Thus, the environmental risks and complaints against the company due to overflows of sewage into the public thoroughfare became common. This neighborhood has shown in recent years an increase of resident higher than the initial expectation of growth. In this sense presumed the large population growth and generation of sewers higher than expected, associated to the use of corrective maintenance and misuse of the system may be the main causes of operational failures occurring in the SES. This study aimed at analyzing the hydraulic behavior of SES Ponta Negrathrough numerical simulation of its operation associated to future scenarios of occupation. The SES Ponta Negra has a long lengthof collection networks and 6 pumping stations interconnected, being EE 1, 2, 4 coastal way, and beach Shopping interconnected EE3 to receives all sewers pumped from the rest pumping station and pumped to the sewage treatment station of neighborhood which consists of a facultative pond followed by three maturation ponds with disposal of treated effluent into infiltration ditches. Oncethey are connected with each other, the study was conducted considering the days and times of higher inflow for all lifts. Furthermore, with the aim of measuring the gatherer network failures were conducted data survey of on the networks. Thephysical and operational survey data was conducted between January/2011 and janeiro/2012. The simulation of the SES was developed with the aim ofdemonstrating its functioning, eithercurrently and in the coming years, based in population estimates and sewage flow. The collected data represents the current framework of the pumping stations of the SES Ponta Negra and served as input to the model developed in MS Excel ® spreadsheet which allowed simulating the behavior of SES in future scenarios. The results of this study show thatBeach Shopping Pumping Station is actually undersized and presents serious functioning problemsthatmay compromise the environmental quality of surrounding area. The other pumping stations of the system will reach itsmaximum capacity between 2013 and 2015, although the EE1 and EE3 demonstrateoperation capacity, even precariously, until 2017. Moreover, it was observed that the misuse of the network system, due to the input of both garbage and stormwater, are major factors of failures that occur in the SES. Finally, it was found that the corrective maintenance appliance, rather than predictive,has proven to beinefficient because of the serious failuresin the system, causing damage to the environment and health risks to users

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stabilization pond is the most used sewage treatment system in the country, corresponding to approximately 90% of all systems. The systems evaluated were stabilization ponds system of sewage treatment in the city of Natal / RN. This research aimed to analyze the possible uses through physical-chemical and bacteriological of these final effluent ponds for urban uses depending on the characteristics after passage around the treatment system. The parameters used were chosen according to those established by Chernicharo et al. (2006), in order to characterize the effluent. The parameters evaluated were: DO, temperature, pH, conductivity, organic nitrogen, ammonia, NTK, total phosphorus, and series of solid fecal coliforms. Generally, the characteristics of the effluent followed variability found in the literature. The results showed an efficiency that is technically feasible to use the effluent end of some of STPs analyzed when checked parameters alone, if fitting in unrestricted urban use, restricted use and urban land use

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A região semiárida sofre escassez hídrica. A fim de regularizar a disponibilidade hídrica nos períodos de estiagem, são construídas barragens. No entanto, a qualidade da água armazenada tem sofrido os efeitos do descarte irregular de resíduos no meio ambiente e das atividades antrópicas exercidas nas bacias hidrográficas. A degradação hídrica pode ser constatada a partir do monitoramento dos parâmetros de qualidade da água. Estes dados podem ser analisados através de métodos estatísticos tais como a Análise de Componentes Principais e a análise de agrupamento, que seleciona indivíduos com características semelhantes. O objetivo deste trabalho é realizar oagrupamento dos reservatórios do Rio Grande do Norte, com base nos parâmetros de qualidade da água, para a identificação de grupos homogêneos de reservatórios em termos de fontes de poluição. Serão objeto desse estudo as bacias Piranhas-Açu, Apodi-Mossoró, Trairí, Potengi e Ceará-Mirim. Os parâmetros mercúrio, chumbo, cromo, fósforo total, nitrogênio total e zinco contribuíram para a formação da primeira componente principal, que pode indicar poluição por metais pesados; sólidos totais, DBO, OD e cobre, para a segunda componente, que pode ser indicativo de poluição por matéria orgânica e atividades antrópicas; e clorofila a , cádmio e níquel, para a terceira componente, que pode indicar eutrofização e poluição por metais pesados. De posse das componentes principais se procedeu o agrupamento dos reservatórios, formando-se quatro grupos distintos. Os grupos 1 e 2 são constituídos por reservatórios da Bacia Piranhas-Açu, que apresentou maiores valores de metais pesados. O grupo 3, constituído por reservatórios das bacias Ceará-Mirim, Potengi e Trairí, apresentou maiores valores de DBO e sólidostotais e o grupo 4 é formado por reservatórios da Bacia Apodi-Mossoró. Nas Bacias do Trarí e Piranhas-Açu deve ser coibido o lançamento desordenado de efluentes e fontes de poluição difusas, e implantado um sistema de coleta de esgoto para minimizar a poluição por matéria orgânica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research evaluated the microalgae removal produced in a stabilization pond system using biofilters as post-treatment, besides characterizing the effluents of stabilization ponds and filters in relation to concentrations of algal biomass (chlorophyll a and suspended solids), organic matter (BOD and COD), total phosphorus, orthophosphate, pH and dissolved oxygen, and tried to correlate physicochemical parameters with chlorophyll "a". It was held at the Ponta Negra ETE which is constituted by three stabilization ponds, with a primary facultative pond and two of maturation. For the algae removal were used two submerged bio-filters: the filter FPF (Facultative Pond Filter), fed with facultative pond effluent; and the filter MPF (Maturation Pond Filter), fed with second maturation pond effluent. The filling material of both filters was predominantly gravel no. 2, although it contains portions of gravel no. 1 and no. 3. The filters operating conditions were bad, they were nearly 10 years without maintenance, without cleaning or removal of sludge since the time of its construction, and part of the filling material may be obstruct. Despite poor operating conditions were obtained satisfactory results, in level of posttreatment. Removal efficiencies in relation to BOD and COD were 7 and 25% in FPF and 9 and 19% and in MPF, respectively. In relation to TSS efficiencies in MPF and FPF were 37 and 20%, respectively. As for the chlorophyll "a" removal, the FPF efficiency was 44% and the MPF was 40%. There was 50% of consumption of dissolved oxygen, on average, within the filters. Two profiles were performed in the filters, and it was possible to conclude that variations throughout the day were not statistically significant, and that, regardless of the time of collection, they would have the same representation comparing to the time of data collection (7 am) and the daily average, although individual variations throughout the day have been shown to be significant. Another important observation is that the correlations between Chlorophyll a and TSS were bigger and more significant in the effluent of the filters than in the effluent of the ponds

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work intends to develop an approach based through scientific criteria in the operational diagnosis of ponds of stabilization, starting from analyses accomplished in loco and in laboratory of 78 systems of sewer treatment through ponds of stabilization in the State of Rio Grande do Norte. The objectives of the research are: to map, to evaluate and to diagnose the operational acting of the ponds of stabilization of the state of Rio Grande do Norte, through visits in loco and analyses laboratory; to build a SIG, through the map rain, locate the points of releases of sewages of the systems of existent ponds in Rio Grande do Norte, as well as operational data and his/her respective efficiency diagnosis in the removal of BOD and Coliforms Termotolerantes; to evaluate, in real scale, three systems of ponds of stabilization of RN in the operational efficiency for the parameters BOD5, COD, pH, Temperature, OD and Coliforms Termotolerantes. Of 78 ETEs of appraised RN just, 9% or 7 had maximum concepts in what concerns the removal of BOD and Coliforms Termotolerantes and 41% or 32, they had the worst concepts in term of operational efficiency. The flowing concentrations ETEs of RN of BOD and Coliforms were of 410mg/L and 2,50x107UFC/100ml, the predominant configuration is of the type F1+M1+M2, the relationship BOD/COD revealed for the sewer tributary characteristic biodegradable high. For the study of case of 3 ETEs, the best operational efficiencies in decreasing order were: Cidade (Municipal district), it Roça (State) and São Miguel (SAAE). The removals of final BOD were 51,6mg/L; 108,27mg/L and 62,6mg/L, tends efficiency of 82%; 74% and 81%. In term of coliforms removal in the final effluentes were 1,90x103UFC/100ml; 1,50x104UFC/100ml and 3,10x104UFC/100ml, tends efficiencies of 99,99%; 99,95% and 99,90%. In what it concerns the practice of agricultural reúso of cultures consumed raw, none of 3 ETEs assisted the parameters of the Resolution CONAMA 357/05, for other reúso practices, all assisted the categories B and C of OMS. For release in body receiving ETE Cidade just, they assist the demands of the resolution of CONAMA 357/05, by study of purification solemnity of the receiving body. The maintenance lack and operation; exclusive operator in ETEs and operation knowledge was the contributory factors for the operational fall in appraised ETEs of RN

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este artigo avaliou a influência do vento em diferentes profundidades na circulação de massa líquida da lagoa facultativa da estação de tratamento de esgotos do município de Álvares Florence, em São Paulo, Brasil, por meio de flutuadores com diferentes dimensões (15, 25 e 35 cm de comprimento). Por meio de um método simples, prático e de baixo custo, foi possível verificar o sentido de circulação da lagoa, o qual, por sua vez, está relacionado com a direção dos ventos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The proposal of this work is to evaluate the influence of the organic matter on the results of the analyses of the metals (Zn, Pb, Al, Cu, Cr, Fe, Cd e Ni) for Atomic Absorption Spectrometry (AAS), so much in the extraction stage as in the reading using for that the chemometrics. They were used for this study sample of bottom sediment collected in river Jundiaí in the vicinity of the city of Macaíba-RN, commercial humus and water of the station of treatment of sewer of UFRN. Through the analyses accomplished by EAA it was verified that the interference of the organic matter happens in the extraction stage and not in the reading. With relationship to the technique of X Ray Fluorescence Spectrometry (XRFS), the present work has as intended to evaluate the viability of this technique for quantitative analysis of trace metals (Cr, Ni, Cu, Zn, Rb, Sr and Pb) in having leached obtained starting from the extraction with acqua regia for an aqueous solution. The used samples constitute the fine fraction (<0.063 mm) of sediments of swamp of the river Jundiaí. The preparation of tablets pressed starting from the dry residue of those leached it allowed your analysis in the solid form. This preliminary study shows that, in the case of the digestion chemistry partially of the fine fractions of bottom sediments used for environmental studies, the technique of applied EFRX to the analysis of dry residues starting from having leached with acqua regia, compared her it analyzes of the leached with ICP-OES, it presents relative mistakes for Cu, Pb, Sr and Zn below 10%

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os atributos físicos e a matéria orgânica do solo influenciam no crescimento e desenvolvimento vegetal, limitando o crescimento de raízes e a produtividade das culturas. Objetivando-se estudar a variabilidade espacial e correlações lineares entre a produtividade do sorgo forrageiro e os atributos físicos e matéria orgânica do solo, realizou-se um experimento em Latossolo Vermelho distroférrico, no município de Selvíria (MS), na safrinha de 2005. Para tanto, estimou-se a produtividade de matéria fresca e seca do sorgo forrageiro, a microporosidade, macroporosidade, porosidade total, densidade e teor de matéria orgânica do solo, em três profundidades (0,00-0,10 m; 0,10-0,20 m; e 0,20-0,30 m). As amostras foram coletadas em uma malha geoestatística, com total de 124 pontos, em área de 4.000 m². As produtividades de matéria fresca e seca apresentaram elevada variabilidade, enquanto, para os atributos do solo, em geral, a variabilidade foi baixa. Os atributos da planta, a macroporosidade (nas primeiras camadas), microporosidade, porosidade total e densidade total, na primeira e terceira camadas, seguiram padrões espaciais bem definidos, com alcances estabelecidos entre 17,9 m e 84,2 m, enquanto os demais atributos apresentaram efeito pepita puro. A correlação linear simples entre os atributos da planta foi alta e positiva, enquanto, entre os atributos da planta com os do solo, foi baixa e significativa, com interações positivas para macroporosidade e porosidade total, bem como negativa para densidade do solo, na primeira camada. A densidade do solo, na menor profundidade, foi um excelente indicador da qualidade física do solo, para a estimativa da produtividade de matéria seca.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo do trabalho foi comparar os efeitos de fontes nitrogenadas: sulfonitrato de amônio com inibidor de nitrificação, sulfato de amônio e uréia, aplicadas na semeadura e/ou em cobertura, sobre teores de N foliar e clorofila, componentes da produção e produtividade do milho no verão, na região de cerrado sob irrigação. O trabalho foi desenvolvido em Latossolo Vermelho Distroférrico, nos anos agrícolas de 2006/2007 e 2007/2008. O delineamento experimental utilizado foi em blocos casualizados com quatro repetições, em esquema fatorial 3x5, sendo: três fontes de nitrogênio aplicadas na semeadura e/ou em cobertura, no estádio de 8 folhas completamente desdobradas, em 5 modos de aplicação (0 + 120; 30 + 90; 60 + 60; 90 + 30 e 120 + 0 kg ha-1 de N). O sulfonitrato de amônio + inibidor de nitrificação difere em relação ao sulfato de amônio quantos aos componentes da produção do milho cultivado no verão, independentemente da época de aplicação. A aplicação de 120 kg ha-1 de nitrogênio usando a uréia em aplicação única no estádio de oito folhas na cultura do milho e em períodos com alta precipitação pluvial afeta negativamente os teores foliares de N no milho e resulta em menor produtividade de grãos em relação à aplicação da mesma dose na semeadura.