900 resultados para Lip surgery


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this multicentre study was to systematically analyse the strengths and weaknesses in the surgical training for endoscopic sinus surgery (ESS) and identify measures that may improve training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Placing portal incisions during arthroscopic hip surgery presents challenges for surgeons in terms of anatomic accessibility and patient safety. Based on key anatomic landmarks and portal placement information from recent literature, suggested portal incisions were determined. Guidance in the placement of the three most common portal incision locations (anterior, anterolateral, and posterolateral) for arthroscopic surgery; in addition to visual feedback on tool trajectory to the hip joint is provided in real time by a computer aided system for hip arthroscopy. By simplifying the portal placement process, one of the most challenging aspects of arthroscopic hip surgery, an increased use of this minimally invasive technique could be possible. In addition to portal information, improvements to an existing computer aided system for arthroscopic hip surgery, including a new hip model and redesigned mechanical tracking linkage, were completed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The three main classes of robotics in ear, nose and throat (ENT) surgery (telemanipulation, image-guided functional servoing, and computer numerical control) are discussed and important examples of applications are described to show both technological and clinical developments. As access to many anatomical features of the head requires very small and compact tools to accurately perform procedures, examples are give in ear surgery where manipulation of the minute ossicles requires fine, dexterous movements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was (1) to determine frequency and type of medication errors (MEs), (2) to assess the number of MEs prevented by registered nurses, (3) to assess the consequences of ME for patients, and (4) to compare the number of MEs reported by a newly developed medication error self-reporting tool to the number reported by the traditional incident reporting system. We conducted a cross-sectional study on ME in the Cardiovascular Surgery Department of Bern University Hospital in Switzerland. Eligible registered nurses (n = 119) involving in the medication process were included. Data on ME were collected using an investigator-developed medication error self reporting tool (MESRT) that asked about the occurrence and characteristics of ME. Registered nurses were instructed to complete a MESRT at the end of each shift even if there was no ME. All MESRTs were completed anonymously. During the one-month study period, a total of 987 MESRTs were returned. Of the 987 completed MESRTs, 288 (29%) indicated that there had been an ME. Registered nurses reported preventing 49 (5%) MEs. Overall, eight (2.8%) MEs had patient consequences. The high response rate suggests that this new method may be a very effective approach to detect, report, and describe ME in hospitals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this study was to investigate whether total arch replacement (TAR) during initial surgery for root aneurysm should be routinely performed in patients with Marfan syndrome (MFS). METHODS: Retrospective analysis of 94 consecutive MFS patients fulfilling Ghent criteria who underwent 148 aortic surgeries and were followed at this institution during the past 16 years. RESULTS: The mean follow-up interval was 8.8 ± 7 years. Initial presentation was acute aortic dissection (AAD) in 35% of patients (76% Type A and 24% Type B) and aneurismal disease in 65%. TAR was performed in 8% of patients during initial surgery for AAD (otherwise a hemi-arch replacement was performed) and 1.6% in elective root repair. Secondary TAR had to be performed in only 3% of patients without, but in 33% following AAD (33% Type A and 33% Type B; P = 0.0001). Thirty-day, 6-month, 1-year and overall mortalities were 3.2, 5.3, 6.4 and 11.7%, respectively. Operative and 30-day mortalities in secondary aortic arch replacement were zero. Secondary TAR after AAD did not increase the need for the replacement of the entire thoracoabdominal aorta during follow-up compared with patients without secondary TAR (37 vs 40%, P = 1.0). CONCLUSIONS: MFS patients undergoing elective root repair have small risk of reinterventions on the aortic arch, and primary prophylactic replacement does not seem to be justified. In patients with AAD, the need for reinterventions is precipitated by the dissection itself and not by limiting the procedure to the hemi-arch replacement in the emergency setting. Limiting surgery to the aortic root, ascending aorta and proximal aortic arch is associated with low mortality in MFS patients presenting with AAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The traditional surgical training in the operating room (OR) is often complemented by participation in workshops and on simulators. The foundation Vascular International offers basic courses for vascular surgery techniques with training on pulsatile circulation, lifelike anatomical models. The aim of this study was to assess the efficacy of a 2.5-day intensive course on basic skills in vascular surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While beneficially decreasing the necessary incision size, arthroscopic hip surgery increases the surgical complexity due to loss of joint visibility. To ease such difficulty, a computer-aided mechanical navigation system was developed to present the location of the surgical tool relative to the patient¿s hip joint. A preliminary study reduced the position error of the tracking linkage with limited static testing trials. In this study, a correction method, including a rotational correction factor and a length correction function, was developed through more in-depth static testing. The developed correction method was then applied to additional static and dynamic testing trials to evaluate its effectiveness. For static testing, the position error decreased from an average of 0.384 inches to 0.153 inches, with an error reduction of 60.5%. Three parameters utilized to quantify error reduction of dynamic testing did not show consistent results. The vertex coordinates achieved 29.4% of error reduction, yet with large variation in the upper vertex. The triangular area error was reduced by 5.37%, however inconsistent among all five dynamic trials. Error of vertex angles increased, indicating a shape torsion using the developed correction method. While the established correction method effectively and consistently reduced position error in static testing, it did not present consistent results in dynamic trials. More dynamic paramters should be explored to quantify error reduction of dynamic testing, and more in-depth dynamic testing methodology should be conducted to further improve the accuracy of the computer-aided nagivation system.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Limitations associated with the visual information provided to surgeons during laparoscopic surgery increases the difficulty of procedures and thus, reduces clinical indications and increases training time. This work presents a novel augmented reality visualization approach that aims to improve visual data supplied for the targeting of non visible anatomical structures in laparoscopic visceral surgery. The approach aims to facilitate the localisation of hidden structures with minimal damage to surrounding structures and with minimal training requirements. The proposed augmented reality visualization approach incorporates endoscopic images overlaid with virtual 3D models of underlying critical structures in addition to targeting and depth information pertaining to targeted structures. Image overlay was achieved through the implementation of camera calibration techniques and integration of the optically tracked endoscope into an existing image guidance system for liver surgery. The approach was validated in accuracy, clinical integration and targeting experiments. Accuracy of the overlay was found to have a mean value of 3.5 mm ± 1.9 mm and 92.7% of targets within a liver phantom were successfully located laparoscopically by non trained subjects using the approach.