958 resultados para Lars Liekenbrock


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Multi-GNSS Experiment (MGEX) of the International GNSS Service (IGS) aims at the data collection and analysis of all available satellite navigation systems. In particular the new global and regional satellite navigation systems are of interest, i.e., the European Galileo, the Chinese BeiDou, the Japanese QZSS as well as satellite based augmentation systems. This article analyzes the orbit and clock quality of the Galileo products of four MGEX analysis centers for a common time period of 20 weeks. Orbit comparisons of the individual analysis centers have a consistency at the 5–30 cm level. Day boundary discontinuities range from 4 to 28 cm whereas 2-day orbit fit RMS values vary between 1 and 7 cm. The accuracy evaluated by satellite laser ranging residuals is on the one decimeter level with a systematic bias of about −5 cm for all analysis centers. In addition, systematic errors on the decimeter level related to solar radiation pressure mismodeling are present in all orbit products. Due to the correlation of radial orbit errors with the clock parameters, these errors are also visible as a bump in the Allan deviation of the Galileo satellite clocks at the orbital frequency.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the advent of multimodality therapy, the overall five-year survival rate from childhood cancer has improved considerably now exceeding 80% in developed European countries. This growing cohort of survivors, with many years of life ahead of them, has raised the necessity for knowledge concerning the risks of adverse long-term sequelae of the life-saving treatments in order to provide optimal screening and care and to identify and provide adequate interventions. Childhood cancer survivor cohorts in Europe. Considerable advantages exist to study late effects in individuals treated for childhood cancer in a European context, including the complementary advantages of large population-based cancer registries and the unrivalled opportunities to study lifetime risks, together with rich and detailed hospital-based cohorts which fill many of the gaps left by the large-scale population-based studies, such as sparse treatment information. Several large national cohorts have been established within Europe to study late effects in individuals treated for childhood cancer including the Nordic Adult Life after Childhood Cancer in Scandinavia study (ALiCCS), the British Childhood Cancer Survivor Study (BCCSS), the Dutch Childhood Oncology Group (DCOG) LATER study, and the Swiss Childhood Cancer Survivor Study (SCCSS). Furthermore, there are other large cohorts, which may eventually become national in scope including the French Childhood Cancer Survivor Study (FCCSS), the French Childhood Cancer Survivor Study for Leukaemia (LEA), and the Italian Study on off-therapy Childhood Cancer Survivors (OTR). In recent years significant steps have been taken to extend these national studies into a larger pan-European context through the establishment of two large consortia - PanCareSurFup and PanCareLIFE. The purpose of this paper is to present an overview of the current large, national and pan-European studies of late effects after childhood cancer. This overview will highlight the strong cooperation across Europe, in particular the EU-funded collaborative research projects PanCareSurFup and PanCareLIFE. Overall goal. The overall goal of these large cohort studies is to provide every European childhood cancer survivor with better care and better long-term health so that they reach their full potential, and to the degree possible, enjoy the same quality of life and opportunities as their peers.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to determine the reliability of the conditioned pain modulation (CPM) paradigm assessed by an objective electrophysiological method, the nociceptive withdrawal reflex (NWR), and psychophysical measures, using hypothetical sample sizes for future studies as analytical goals. Thirty-four healthy volunteers participated in two identical experimental sessions, separated by 1 to 3 weeks. In each session, the cold pressor test (CPT) was used to induce CPM, and the NWR thresholds, electrical pain detection thresholds and pain intensity ratings after suprathreshold electrical stimulation were assessed before and during CPT. CPM was consistently detected by all methods, and the electrophysiological measures did not introduce additional variation to the assessment. In particular, 99% of the trials resulted in higher NWR thresholds during CPT, with an average increase of 3.4 mA (p<0.001). Similarly, 96% of the trials resulted in higher electrical pain detection thresholds during CPT, with an average increase of 2.2 mA (p<0.001). Pain intensity ratings after suprathreshold electrical stimulation were reduced during CPT in 84% of the trials, displaying an average decrease of 1.5 points in a numeric rating scale (p<0.001). Under these experimental conditions, CPM reliability was acceptable for all assessment methods in terms of sample sizes for potential experiments. The presented results are encouraging with regards to the use of the CPM as an assessment tool in experimental and clinical pain. Trial registration: Clinical Trials.gov NCT01636440.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Empirical CODE Orbit Model (ECOM) of the Center for Orbit Determination in Europe (CODE), which was developed in the early 1990s, is widely used in the International GNSS Service (IGS) community. For a rather long time, spurious spectral lines are known to exist in geophysical parameters, in particular in the Earth Rotation Parameters (ERPs) and in the estimated geocenter coordinates, which could recently be attributed to the ECOM. These effects grew creepingly with the increasing influence of the GLONASS system in recent years in the CODE analysis, which is based on a rigorous combination of GPS and GLONASS since May 2003. In a first step we show that the problems associated with the ECOM are to the largest extent caused by the GLONASS, which was reaching full deployment by the end of 2011. GPS-only, GLONASS-only, and combined GPS/GLONASS solutions using the observations in the years 2009–2011 of a global network of 92 combined GPS/GLONASS receivers were analyzed for this purpose. In a second step we review direct solar radiation pressure (SRP) models for GNSS satellites. We demonstrate that only even-order short-period harmonic perturbations acting along the direction Sun-satellite occur for GPS and GLONASS satellites, and only odd-order perturbations acting along the direction perpendicular to both, the vector Sun-satellite and the spacecraft’s solar panel axis. Based on this insight we assess in the third step the performance of four candidate orbit models for the future ECOM. The geocenter coordinates, the ERP differences w. r. t. the IERS 08 C04 series of ERPs, the misclosures for the midnight epochs of the daily orbital arcs, and scale parameters of Helmert transformations for station coordinates serve as quality criteria. The old and updated ECOM are validated in addition with satellite laser ranging (SLR) observations and by comparing the orbits to those of the IGS and other analysis centers. Based on all tests, we present a new extended ECOM which substantially reduces the spurious signals in the geocenter coordinate z (by about a factor of 2–6), reduces the orbit misclosures at the day boundaries by about 10 %, slightly improves the consistency of the estimated ERPs with those of the IERS 08 C04 Earth rotation series, and substantially reduces the systematics in the SLR validation of the GNSS orbits.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND New psychoactive substances (NPS) have become increasingly prevalent and are sold in internet shops as 'bath salts' or 'research chemicals' and comprehensive bioanalytical methods are needed for their detection. METHODOLOGY We developed and validated a method using LC and MS/MS to quantify 56 NPS in blood and urine, including amphetamine derivatives, 2C compounds, aminoindanes, cathinones, piperazines, tryptamines, dissociatives and others. Instrumentation included a Synergi Polar-RP column (Phenomenex) and a 3200 QTrap mass spectrometer (AB Sciex). Run time was 20 min. CONCLUSION A novel method is presented for the unambiguous identification and quantification of 56 NPS in blood and urine samples in clinical and forensic cases, e.g., intoxications or driving under the influence of drugs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE Cochlear implants (CIs) are standard treatment for postlingually deafened individuals and prelingually deafened children. This human cadaver study evaluated diagnostic usefulness, image quality and artifacts in 1.5T and 3T magnetic resonance (MR) brain scans after CI with a removable magnet. METHODS Three criteria (diagnostic usefulness, image quality, artifacts) were assessed at 1.5T and 3T in five cadaver heads with CI. The brain magnetic resonance scans were performed with and without the magnet in situ. The criteria were analyzed by two blinded neuroradiologists, with focus on image distortion and limitation of the diagnostic value of the acquired MR images. RESULTS MR images with the magnet in situ were all compromised by artifacts caused by the CI. After removal of the magnet, MR scans showed an unequivocal artifact reduction with significant improvement of the image quality and diagnostic usefulness, both at 1.5T and 3T. Visibility of the brain stem, cerebellopontine angle, and parieto-occipital lobe ipsilateral to the CI increased significantly after magnet removal. CONCLUSIONS The results indicate the possible advantages for 1.5T and 3T MR scanning of the brain in CI carriers with removable magnets. Our findings support use of CIs with removable magnets, especially in patients with chronic intracranial pathologies.