919 resultados para INTRAVASCULAR ULTRASOUND


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present an electrochemical exfoliation method to produce controlled thickness graphene flakes by ultrasound assistance. Bilayer graphene flakes are dominant in the final product by using sonication during the electrochemical exfoliation process, while without sonication the product contains a larger percentage of four-layer graphene flakes. Graphene sheets prepared by using the two procedures are processed into films to measure their respective sheet resistance and optical transmittance. Solid-state electrolyte supercapacitors are made using the two types of graphene films. Our study reveals that films with a higher content of multilayer graphene flakes are more conductive, and their resistance is more easily reduced by thermal annealing, making them suitable as transparent conducting films. The film with higher content of bilayer graphene flakes shows instead higher capacitance when used as electrode in a supercapacitor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives The purpose of the study was to establish regression equations that could be used to predict muscle thickness and pennation angle at different intensities from electromyography (EMG) based measures of muscle activation during isometric contractions. Design Cross-sectional study. Methods Simultaneous ultrasonography and EMG were used to measure pennation angle, muscle thickness and muscle activity of the rectus femoris and vastus lateralis muscles, respectively, during graded isometric knee extension contractions performed on a Cybex dynamometer. Data form fifteen male soccer players were collected in increments of approximately 25% intensity of the maximum voluntary contraction (MVC) ranging from rest to MVC. Results There was a significant correlation (P < 0.05) between ultrasound predictors and EMG measures for the muscle thickness of rectus femoris with an R2 value of 0.68. There was no significant correlation (P > 0.05) between ultrasound pennation angle for the vastus lateralis predictors for EMG muscle activity with an R2 value of 0.40. Conclusions The regression equations can be used to characterise muscle thickness more accurately and to determine how it changes with contraction intensity, this provides improved estimates of muscle force when using musculoskeletal models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Contrast enhanced echocardiography (CEE) is utilised when sub-optimal image quality results in non-diagnostic echocardiograms. However, there have been numerous safety notices issued by regulatory authorities regarding rare but potentially serious adverse reactions (AR). This multi-centre, retrospective analysis was performed to assess the short-term safety of CEE in a broad range of indications. Methods All CEE performed over 58 months at three institutions were assessed for AR within 30 min. Results A total of 5956 CEE were performed in 5576 patients. A total of 4903 were stress CEE and 1053 resting CCE.Bolus administration in 5719, infusion in 237 cases; 89.9% of CCE were outpatients. Commonest CEE indication was functional stress testing (82.3%). There were 16 AR related to CEE (0.27%). All AR were mild, transient and all patients made a full recovery. No cases of serious anaphylaxis or death within 30 min of contrast administration. Comparing those with and without an AR, there were no significant differences in age, gender, BMI, LVEF, patient location, exam type or RVSP. There was a slightly increased likelihood of an AR during infusion versus bolus dosing (p = 0.02). Conclusion CEE is a safe investigation in a broad range of indications and clinical scenarios. AR are very rare, mild and transient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Ankle joint equinus, or restricted dorsiflexion range of motion (ROM), has been linked to a range of pathologies of relevance to clinical practitioners. This systematic review and meta-analysis investigated the effects of conservative interventions on ankle joint ROM in healthy individuals and athletic populations. METHODS: Keyword searches of Embase Medline Cochrane and CINAHL databases were performed with the final search being run in August 2013. Studies were eligible for inclusion if they assessed the effect of a non-surgical intervention on ankle joint dorsiflexion in healthy populations. Studies were quality rated using a standard quality assessment scale. Standardised mean differences (SMDs) and 95% confidence intervals (CIs) were calculated and results were pooled where study methods were homogenous. RESULTS: Twenty-three studies met eligibility criteria, with a total of 734 study participants. Results suggest that there is some evidence to support the efficacy of static stretching alone (SMDs: range 0.70 to 1.69) and static stretching in combination with ultrasound (SMDs: range 0.91 to 0.95), diathermy (SMD 1.12), diathermy and ice (SMD 1.16), heel raise exercises (SMDs: range 0.70 to 0.77), superficial moist heat (SMDs: range 0.65 to 0.84) and warm up (SMD 0.87) in improving ankle joint dorsiflexion ROM. CONCLUSIONS: Some evidence exists to support the efficacy of stretching alone and stretching in combination with other therapies in increasing ankle joint ROM in healthy individuals. There is a paucity of quality evidence to support the efficacy of other non-surgical interventions, thus further research in this area is warranted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. In isotropic materials, the speed of acoustic wave propagation is governed by the bulk modulus and density. For tendon, which is a structural composite of fluid and collagen, however, there is some anisotropy requiring an adjustment for Poisson's ratio. This paper explores these relationships using data collected, in vivo, on human Achilles tendon and then compares estimates of elastic modulus and hysteresis against published values from in vitro mechanical tests. Methods. Measurements using conventional B-model ultrasound imaging, inverse dynamics and acoustic transmission techniques were used to determine dimensions, loading conditions and longitudinal speed of sound in the Achilles tendon during a series of isometric plantar flexion exercises against body weight. Upper and lower bounds for speed of sound versus tensile stress in the tendon were then modelled and estimates of the elastic modulus and hysteresis of the Achilles tendon derived. Results. Axial speed of sound varied between 1850 and 2090 ms-1 with a non-linear, asymptotic dependency on the level of tensile stress (5-35 MPa) in the tendon. Estimates derived for the elastic modulus of the Achilles tendon ranged between 1-2 GPa. Hysteresis derived from models of the stress-strain relationship, ranged from 3-11%. Discussion. Estimates of elastic modulus agree closely with those previously reported from direct measurements obtained via mechanical tensile tests on major weight bearing tendons in vitro [1,2]. Hysteresis derived from models of the stress-strain relationship is consistent with direct measures from various mamalian tendon (7-10%) but is lower than previous estimates in human tendon (17-26%) [3]. This non-invasive method would appear suitable for monitoring changes in tendon properties during dynamic sporting activities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Child born with gross hydrocephalus - cerebral palsy - questions surrounding obstetrician's notes - ultrasound not ordered - illegible handwriting - importance of legible, accurate and detailed medical records - causation - child born with congenital varicella syndrome (CVS) - chicken pox - forseeability of risk.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The book is mostly designed for students of echocardiography, teachers of echocardiography and cardiac sonographers working in routine clinical practice, but will also be very useful to echocardiologists and cardiac registrars. The goal of the text is to provide a comprehensive review of transthoracic echocardiography in the assessment of various cardiac pathologies. Refresher notes on cardiac anatomy and the relevant cardiac physiology and pathophysiology are included to expand the cardiac sonographer’s knowledge in this area and further their understanding of various diseases, disease processes and associated findings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction Clinical guidelines for the treatment of chronic low back pain suggest the use of supervised exercise. Motor control (MC) based exercise is widely used within clinical practice but its efficacy is equivalent to general exercise therapy. MC exercise targets the trunk musculature. Considering the mechanical links between the hip, pelvis, and lumbar spine, surprisingly little focus has been on investigating the contribution of the hip musculature to lumbopelvic support. The purpose of this study is to compare the efficacy of two exercise programs for the treatment of non-specific low back pain (NSLBP). Methods Eighty individuals aged 18-65 years of age were randomized into two groups to participate in this trial. The primary outcome measures included self-reported pain intensity (0-100mm VAS) and percent disability (Oswestry Disability Index V2). Bilateral measures of hip strength (N/kg) and two dimensional frontal plane mechanics (º) were the secondary outcomes. Outcomes were measured at baseline and following a six-week home based exercise program including weekly sessions of real-time ultrasound imaging. Results Within group comparisons revealed clinically meaningful reductions in pain for both groups. The MC exercise only (N= 40, xˉ =-20.9mm, 95%CI -25.7, -16.1) and the combined MC and hip exercise (N= 40, xˉ = -24.9mm, 95%CI -30.8, -19.0). There was no statistical difference in the change of pain (xˉ =-4.0mm, t= -1.07, p=0.29, 95%CI -11.5, 3.5) or disability (xˉ =-0.3%, t=-0.19, p=0.85, 95%CI -11.5, 3.5) between groups. Conclusion Both exercise programs had similar and positive effects on NSLBP which support the use of the home based exercise programs with weekly supervised visits. However, the addition of specific hip strengthening exercises to a MC based exercise program did not result in significantly greater reductions in pain or disability. Trial Registration NCTO1567566 Funding: Worker’s Compensation Board Alberta Research Grant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To determine i) the reliability of two-dimensional ultrasonography for the assessment of biceps femoris long head (BFlh) architectural characteristics; ii) if limbs with a history of strain injury in the BFlh display different architecture and eccentric strength compared to uninjured limbs. Methods: This case-control study (control [n=20], injured group [n=16], males) assessed the BFlh architecture at rest and during graded isometric contractions using two-dimensional ultrasonography. The control group were assessed three times (>24hrs apart) to determine reliability. Previously injured individuals were evaluated once. Results The assessment of BFlh architecture was highly reliable (intraclass correlations >0.90). Fascicle length (p<0.001; d range: 0.67 to 1.34) and fascicle length relative to muscle thickness (p<0.001; d range: 0.58 to 0.85) of the previously injured BFlh were significantly less than the contralateral uninjured BFlh at all intensities. Pennation angle of the previously injured BFlh was significantly greater (p<0.001; d range: 0.62 to 0.88) than the contralateral uninjured BFlh at all intensities. Eccentric strength in the previously injured limb was significantly lower than the contralateral limb (-15.4%; -52.5N; 95% CI=-28.45 to -76.23; p<0.001, d=0.56). Conclusion These data indicate that two-dimensional ultrasonography is reliable for assessing BFlh architecture at rest and during graded isometric contractions. Fascicle length, fascicle length relative to muscle thickness and pennation angle are significantly different in previously injured BFlh compared to an uninjured contralateral BFlh. Eccentric strength of the previously injured limb is also significantly lower than the uninjured contralateral limb. These findings have implications for rehabilitation and injury prevention practices which should consider altered architectural characteristics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction This research evaluated the effect of tendinopathy on the cumulative transverse strain response of the patellar tendon to a bout of resistive quadriceps exercise. Methods Nine adults with unilateral patellar tendinopathy (age 18.2±0.7 years, height 1.92±0.06 m and weight 76.8±6.8 kg) and ten healthy adults free of knee pain (age 17.8±0.8 years, height 1.83±0.05 m and weight 73.2±7.6 kg) underwent standardised sagittal sonograms (7.2–14 MHz linear–array transducer) of both patellar tendons immediately prior and following 45 repetitions of a double–leg decline–squat exercise performed against a resistance of 145% bodyweight. Tendon thickness was determined 5–mm and 25–mm distal to the patellar pole. Transverse Hencky strain was calculated as the natural log of the ratio of post– to pre–exercise tendon thickness and expressed as a percentage. Measures of tendon echogenicity were calculated within the superficial and deep aspects of each tendon site from gray–scale profiles. Intratendinous microvessels were evaluated using power Doppler ultrasound. Results The cumulative transverse strain response to exercise in symptomatic tendinopathy was significantly lower than that of asymptomatic and healthy tendon (P<.05). There was also a significant reduction (57%) in the area of microvascularity immediately following exercise (P=.05), which was positively correlated (r=0.93, P<.05) with VISA-P score. Conclusions This study is the first to show that patellar tendinopathy is associated with an altered morphological and mechanical response of the tendon to exercise, which is manifest by a reduction in cumulative transverse strain and microvascularity, when present. Research directed toward identifying factors that influence the acute microvascular and transverse strain response of the patellar tendon to exercise in the various stages of tendinopathy is warranted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Footwear remains a prime candidate for the prevention and rehabilitation of Achilles tendinopathy as it is thought to decrease tension in the tendon through elevation of the heel. However, evidence for this effect is equivocal. Purpose: This study used an acoustic transmission technique to investigate the effect of running shoes on Achilles tendon loading during barefoot and shod walking. Methods: Acoustic velocity was measured in the Achilles tendon of twelve recreationally–active males (age, 31±9 years; height, 1.78±0.06 m; weight, 81.0±16.9 kg) during barefoot and shod walking at matched self–selected speed (3.4±0.7 km/h). Standard running shoes incorporating a 10– mm heel offset were used. Vertical ground reaction force and spatiotemporal parameters were determined with an instrumented treadmill. Axial acoustic velocity in the Achilles tendon was measured using a custom built ultrasonic device. All data were acquired at a rate of 100 Hz during 10s of steady–state walking. Statistical comparisons between barefoot and shod conditions were made using paired t–tests and repeated measure ANOVAs. Results: Acoustic velocity in the Achilles tendon was highly reproducible and was typified by two maxima (P1, P2) and minima (M1, M2) during walking. Footwear resulted in a significant increase in step length, stance duration and peak vertical ground reaction force compared to barefoot walking. Peak acoustic velocity in the Achilles tendon (P1, P2) was significantly higher with running shoes. Conclusions: Peak acoustic velocity in the Achilles tendon was higher with footwear, suggesting that standard running shoes with a 10–mm heel offset increase tensile load in the Achilles tendon. Although further research is required, these findings question the therapeutic role of standard running shoes in Achilles tendinopathy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives To compare the efficacy of two exercise programs in reducing pain and disability for individuals with non-specific low back pain and to examine the underlying mechanical factors related to pain and disability for individuals with NSLBP. Design A single-blind, randomized controlled trial. Methods: Eighty participants were recruited from eleven community-based general medical practices and randomized into two groups completing either a lumbopelvic motor control or a combined lumbopelvic motor control and progressive hip strengthening exercise therapy program. All participants received an education session, 6 rehabilitation sessions including real time ultrasound training, and a home based exercise program manual and log book. The primary outcomes were pain (0-100mm visual analogue scale), and disability (Oswestry Disability Index V2). The secondary outcomes were hip strength (N/kg) and two-dimensional frontal plane biomechanics (°) measure during the static Trendelenburg test and while walking. All outcomes were measured at baseline and at 6-week follow up. Results There was no statistical difference in the change in pain (xˉ = -4.0mm, t= -1.07, p =0.29, 95%CI -11.5, 3.5) or disability (xˉ = -0.3%, t= -0.19, p =0.85, 95%CI -3.5, 2.8) between groups. Within group comparisons revealed clinically meaningful reductions in pain for both Group One (xˉ =-20.9mm, 95%CI -25.7, -16.1) and Group Two (xˉ =-24.9, 95%CI -30.8, -19.0). Conclusion Both exercise programs had similar efficacy in reducing pain. The addition of hip strengthening exercises to a motor control exercise program does not appear to result in improved clinical outcome for pain for individuals with non-specific low back pain.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two ultrasound survey methods were used to determine the presence and activity patterns of New Zealand long-tailed bats (Chalinolobus tuberculatus) in the city of Hamilton. First, 13 monthly surveys conducted at 18 green spaces found C. tuberculatus in only one urban forest reserve, Hammond Bush, where they were found consistently throughout the year. Bat activity was strongly related to temperature. Second, twice-yearly citywide surveys conducted over 2 years determined the distribution and habitat associations of C. tuberculatus. Bats were found only in the southern part of the city and were strongly associated with the Waikato River. Bat activity was negatively correlated with housing and street light density and positively correlated with topographical complexity. In Hamilton, topographical complexity indicates the presence of gullies. Gullies probably provide foraging and roosting opportunities and connect the river to distant forest patches. These results suggest that urban habitats can be useful for bats if gullies can link these to distant habitat fragments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ultrasonic vocalisations (frequencies > 20 kHz) have been extensively studied in the context of echolocation by bats and other mammals (Sales & Pye 1974; Wilson & Hare 2004). Ultrasonic calls have also been recorded from birds, including the blue-throated hummingbird ( Lampornis clemenciae ) (Pytte et al. 2004), where it was first thought that individuals made use of high pitch calls to avoid masking by background noise in a visually obscured environment. Similarly, city-dwelling great tits ( Parus major ) use song with a higher minimum frequency (although not ultrasonic) compared to woodland birds to communicate with conspecifics to avoid the predominantly low-frequency background noise in the city (Slabbekorn & Peet 2003). The theory that birds use ultrasound to avoid noise masking was discarded when it was discovered that there was no corresponding auditory brainstem response (i.e. sensory perception) to the ultrasonic calls in the hummingbirds producing those calls.