974 resultados para IEC 2-3-A method
Resumo:
Bound and resonance states of HO2 have been calculated quantum mechanically by the Lanczos homogeneous filter diagonalization method [Zhang and Smith, Phys. Chem. Chem. Phys. 3, 2282 (2001); J. Chem. Phys. 115, 5751 (2001)] for nonzero total angular momentum J = 1,2,3. For lower bound states, agreement between the results in this paper and previous work is quite satisfactory; while for high lying bound states and resonances these are the first reported results. A helicity quantum number V assignment (within the helicity conserving approximation) is performed and the results indicate that for lower bound states it is possible to assign the V quantum numbers unambiguously, but for resonances it is impossible to assign the V helicity quantum numbers due to strong mixing. In fact, for the high-lying bound states, the mixing has already appeared. These results indicate that the helicity conserving approximation is not good for the resonance state calculations and exact quantum calculations are needed to accurately describe the reaction dynamics for HO2 system. Analysis of the resonance widths shows that most of the resonances are overlapping and the interferences between them lead to large fluctuations from one resonance to another. In accord with the conclusions from earlier J = 0 calculations, this indicates that the dissociation of HO2 is essentially irregular. (C) 2003 American Institute of Physics.
Resumo:
Matrix photolysis of 3-methoxycarbonyl-1,2,3-triazolo[1,5-a]pyridine (12) affords s-E-2-pyridylketene (4), but flash vacuum thermolysis of 12 gives methoxy(2-pyridyl)ketene (15), predominantly in the s-Z-conformation. Matrix photolysis of 15 affords 2-acetylpyridine. Copyright (C) 2003 John Wiley Sons, Ltd.
Resumo:
A antracnose é responsável por significativos danos no pós-colheita em frutos de mamão, ocasionando expressivas perdas aos produtores. Desta forma, objetivou-se avaliar a eficiência de novas moléculas fungicidas do grupo dos triazóis obtidas a partir de glicerol no manejo in vitro de Colletotrichum gloeosporioides. O experimento foi conduzido em delineamento inteiramente casualizado, em esquema fatorial 18x5+1 (17 moléculas inéditas de triazóis (T1 a T17), 1 fungicida comercial (tebuconazol), cinco concentrações e uma testemunha adicional, com cinco repetições por tratamento. Para avaliar o efeito das moléculas no crescimento micelial e esporulação do fungo foi empregado o método de incorporação de cada molécula ao meio de cultura batata-dextrose-ágar nas concentrações de 1, 10, 100, 500 e 1000 ppm. Com base nos resultados obtidos foi observada diferença significativa entre os tratamentos e concentrações tanto para o crescimento micelial quanto esporulação, sendo que quanto maior a concentração testada maior o efeito fungistático e/ou fungicida dos compostos triazólicos. O efeito inibitório dos fungicidas foi maior sobre a esporulação do que no crescimento micelial, sendo os triazóis T12 e T14 os mais eficazes, havendo inibição completa do patógeno a partir das concentrações de 414,17 e 393,79 ppm, respectivamente. É válido ressaltar que além destes os triazóis T11, T16 e T17 também apresentaram completa inibição do patógeno em concentrações acima de 500 ppm, merecendo ser também estudados em experimentos futuros in vivo. Os valores médios de ED50 e ED100 foram menores para esporulação em relação ao crescimento micelial, demonstrando a eficiência antiesporulante dos novos triazóis sintetizados a partir do glicerol. Assim, conclui-se que compostos com anel 1,2,3-triazol sintetizados a partir do glicerol possuem atividade fungicida sobre C. gloeosporioides, sendo promissores para o manejo da antracnose em mamoeiro.
Resumo:
O descarte ou reutilização da água produzida da indústria do petróleo é difícil por causa dos impactos ambientais causados devido à presença de alta salinidade e componentes tóxicos, ou pelo risco de obstrução nas colunas de produção devido à formação de incrustações que causam redução na produção de petróleo e enormes perdas no processo de extração. Assim, o conhecimento da composição química da água produzida é muito importante. O método proposto por este trabalho visa a determinação de elementos traço (Co, Cr, Fe, Mn, Ni, Se e V) em amostras de água produzida de petróleo por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) utilizando a digestão ácida assistida por micro-ondas para o preparo das amostras (15 g de amostra e 2 mL de HNO3 concentrado). A curva analítica construída em HNO3 2% v v-1 foi adotada para o método após verificar que não é necessário o uso de salinidade para equiparação de matriz. Para o elemento Ni, não há necessidade do uso de padrão interno, para os elementos Co, Cr, Fe, Mn e V os melhores resultados foram obtidos usando Sc como padrão interno. Para o elemento Se é recomendado o uso de Y como padrão interno. Os limites de detecção obtidos foram Co 0,67, Cr 1,2, Fe 2,3, Mn 0,49, Ni 1,9, Se 3,7 e V 5,5 μg L-1; e os limites de quantificação foram Co 2,2, Cr 4,0, Fe 7,7, Mn 1,6, Ni 6,5, Se 12,4 e V 18,3 μg L-1. A exatidão do procedimento foi verificada através de testes de recuperação em dois níveis de concentração (40 e 80 μg L-1) e análise dos materiais certificados de referência de água estuarina SLEW-2 e de água do mar NASS-5. Bons valores de recuperação foram obtidos e não houve diferença significativa (95% de confiança) entre os resultados obtidos e os valores certificados dos materiais de referência.
Resumo:
When the electrostatic spraying is used correctly, it provides advantages over conventional systems, however many factors can affect the system efficiency. Therefore, the objective of this study was to evaluate the charge/mass ratio (Q/M) at different spraying distances (0, 1, 2, 3, 4 and 5 m), and the liquid deposition efficiency on the target. Evaluating the Q/M ratio the Faraday cage method was used and to evaluate the liquid deposition efficiency the artificial targets were positioned longitudinally and transversely to the spray jet. It was found that the spraying distance affects the Q/M ratio, consequently, the liquid deposition efficiency. For the closest distance to the target the Q/M ratio was 4.11 mC kg-1, and at distances of 1, 2, 3, 4 and 5 m, the ratio decreased to 1.38, 0.64, 0.31, 0.17 and 0.005 mC kg-1, respectively. For the liquid deposition, the electrostatic system was affected by the target orientation and spraying distance. The target transversely to the jet of liquid did not improve the liquid deposition, but longitudinally increased the deposition up to 3 meters of distance.
Resumo:
CoDeSys "Controller Development Systems" is a development environment for programming in the area of automation controllers. It is an open source solution completely in line with the international industrial standard IEC 61131-3. All five programming languages for application programming as defined in IEC 61131-3 are available in the development environment. These features give professionals greater flexibility with regard to programming and allow control engineers have the ability to program for many different applications in the languages in which they feel most comfortable. Over 200 manufacturers of devices from different industrial sectors offer intelligent automation devices with a CoDeSys programming interface. In 2006, version 3 was released with new updates and tools. One of the great innovations of the new version of CoDeSys is object oriented programming. Object oriented programming (OOP) offers great advantages to the user for example when wanting to reuse existing parts of the application or when working on one application with several developers. For this reuse can be prepared a source code with several well known parts and this is automatically generated where necessary in a project, users can improve then the time/cost/quality management. Until now in version 2 it was necessary to have hardware interface called “Eni-Server” to have access to the generated XML code. Another of the novelties of the new version is a tool called Export PLCopenXML. This tool makes it possible to export the open XML code without the need of specific hardware. This type of code has own requisites to be able to comply with the standard described above. With XML code and with the knowledge how it works it is possible to do component-oriented development of machines with modular programming in an easy way. Eplan Engineering Center (EEC) is a software tool developed by Mind8 GmbH & Co. KG that allows configuring and generating automation projects. Therefore it uses modules of PLC code. The EEC already has a library to generate code for CoDeSys version 2. For version 3 and the constant innovation of drivers by manufacturers, it is necessary to implement a new library in this software. Therefore it is important to study the XML export to be then able to design any type of machine. The purpose of this master thesis is to study the new version of the CoDeSys XML taking into account all aspects and impact on the existing CoDeSys V2 models and libraries in the company Harro Höfliger Verpackungsmaschinen GmbH. For achieve this goal a small sample named “Traffic light” in CoDeSys version 2 will be done and then, using the tools of the new version it there will be a project with version 3 and also the EEC implementation for the automatically generated code.
Resumo:
O presente trabalho descreve o estudo da actividad e antimicrobiana de quarto derivados da quinoxalina N,N-dióxido: quinoxalina 1,4-dióxido, 2-metilquinoxalina 1,4- dióxido, 6-cloro-2,3-dimetilquinoxalina 1,4-dióxido e 3-benzoil-2-metilquinoxalina 1,4- dióxido contra as estirpes bacterianas Geobacillus stearothermophilus ATCC 10149, Escherichia coli ATCC 25922, Escherichia coli HB101, Escherichia coli (blaTEM, blaCTX-M) e Salmonella (blaCTX-M), assim como contra a estirpe de levedura Saccharomyces cerevisiae PYCC 4072. A determinação da concentração mínima inibitória (MIC) foi realizada pelo método de diluição. Os valores de MIC’s foram estimados para cada composto e estirpe. Os resultados obtidos sugerem potenciais novas drogas para quimioterapia.
Resumo:
Ionic Liquids (ILs) are ionic compounds that possess melting temperature below 100ºC and they have been a topic of great interest since the mid-1990s due to their unique properties. The range of IL uses has been broadened, due to a significant increase in the variety of physical, chemical and biological ILs properties. They are now used as Active Pharmaceutical Ingredients (APIs) and recent interests are focused on their application as innovative solutions in new medical treatment and delivery options.1 In this work, our principal objective was the synthesis and investigation of physicochemical and medical properties of ionic liquids (ILs) and organic salts from ampicillin. This approach is of huge interest in pharmaceutical industry as cation and anion composition of ILs and organic salts can greatly alter their desired properties, namely the melting temperature and even synergistic effects can be obtained.2,3 For the synthesis of these compounds we used a recently developed method proposed by Ohno et al.4 for the preparation of quaternary ammonium and phosphonium hydroxides, that were neutralized by ampicillin. After purification we obtained pure ILs and salts in good yields. These ILs shows good antimicrobial and antifungal activities. As it is well known that some ionic liquids containing phosphonium and ammonium cation also shows anti-cancer activity1,5 we also decided to study these compounds against some cancer cell lines.
Resumo:
Dissertação de Mestrado, Ciências Sociais, 11 de Abril de 2014, Universidade dos Açores.
Resumo:
The compounds [mPTA][CoCl4] (1, mPTA = N-methyl-1,3,5-triaza-7-phosphaadamantane cation), [CoCl(H2O)(DION)(2)][BF4] (2, DION = 1,10-phenanthroline-5,6-dione), [Zn(DION)(2)]Cl-2 (3) and [ZnCl(O-PTA=O)(DION)][BF4] (4) were synthesized by reaction of CoCl2 with [mPTA]I or DION and ZnCl2 with DION or 1,3,5-triaza-7-phosphaadamantane-7-oxide (PTA=O) and DION, respectively. All complexes are water soluble and have been characterized by IR, far-IR, H-1, C-13 and P-31{H-1} NMR spectroscopy, ESI-MS, elemental analyses and single-crystal X-ray diffraction structural analysis (for 1). They were screened against the human tumour cell lines HCT116, HepG2 and MCF7. Complexes 2 and 3 exhibit the highest in vitro cytotoxicity and show lower cytotoxic activities in normal human fibroblast cell line than in HCT116 tumour cell line, which demonstrates their slight specificity for this type of tumour cell.
Resumo:
Ibuprofen is one of the most used active pharmaceutical ingredients worldwide. A new method for the analysis of ibuprofen and its metabolites, hydroxyibuprofen and carboxyibuprofen, in soils is presented. The extraction of these compounds from the soil matrices was performed by using a modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) method. The method involves a single extraction of the investigated compounds with purified water (acidified at pH 2.5 with hydrochloric acid), and a slow and continuous addition of the QuEChERS content, followed by the addition of acidified acetonitrile (1% acetic acid), prior to the determination by liquid chromatography coupled with fluorescence detection (LC–FLD). Validation studies were carried out using soil samples with a range of organic carbon contents. Recoveries of the fortified samples ranged from 79.5% to 101%. Relative standard deviations for all matrix–compound combinations did not exceed 3%. The method quantification limits were ≤22.4 μg kg−1 in all cases. The developed method was applied to the analysis of sixteen real samples.
Resumo:
Cada vez mais começa a notar-se, na indústria vitivinícola, uma grande preocupação com a qualidade dos seus produtos, motivada pela maior sensibilização e exigência dos consumidores. Deste modo, a presença de defeitos organoléticos no vinho representa uma fonte de perda financeira nesta indústria, pelo que o seu controlo se torna indispensável para que se obtenha um produto de elevada qualidade. Neste sentido, torna-se interessante desenvolver um método de análise que seja rápido de forma a permitir a quantificação simultânea das moléculas identificadas como principais responsáveis pelos distúrbios olfativos dos vinhos. Assim, este trabalho surge com o objetivo de implementar e validar um método para a determinação de contaminantes em vinho por microextração em fase sólida (SPME) e cromatografia gasosa acoplada à espetrometria de massa tandem (GC-MS/MS) e a sua correlação com a análise sensorial. A técnica de microextração em fase sólida é simples e rápida na medida em que não requer um pré-tratamento da amostra. Por sua vez, a análise por GC-MS permite identificar de forma clara os compostos em estudo, nomeadamente, 4-Etilfenol (4-EP), 4-Etilguaiacol (4-EG), 2,4,6-Tricloroanisol (TCA), 2,3,4,6-Tetracloroanisol (TeCA) e 2,4,6-Tribromoanisol (TBA). Foram realizados estudos de otimização das condições de extração, comparando as fibras 100 μm PDMS e 50/30 μm DVB/CAR/PDMS. Obtiveram-se resultados mais satisfatórios, em termos de resposta e da relação sinal/ruído, com a fibra 50/30 μm DVB/CAR/PDMS e estabeleceram-se como condições de extração 55ºC para a temperatura de incubação/extração, uma velocidade de agitação de 250 rpm e 60 minutos de tempo de extração. Ao longo deste trabalho, analisaram-se 50 amostras de vinho, das quais 48 eram amostras de Vinho Tinto do Douro e 2 de Vinho do Porto. Para validar a metodologia foram realizados estudos de linearidade, limiares analíticos, repetibilidade, precisão intermédia e recuperação. De um modo geral, obtiveram-se bons resultados ao nível da linearidade para as gamas de concentração escolhidas. Quanto aos limites de deteção e de quantificação, o 4-EP é o contaminante que apresenta uma gama de concentrações mais alta, notando-se limiares analíticos mais elevados, com valores próximos dos últimos níveis de concentração, oscilando entre 65 e 583 μg/L. No caso dos Anisóis, o TBA apresenta limites de deteção mais baixos, entre 0,4 e 17,0 ng/L. Os limiares analíticos foram validados com recurso a estudos de precisão intermédia e repetibilidade, cujos resultados se encontram dentro das especificações descritas no documento SANCO/10684/2009 (%RSD ≤ 30% para os Anisóis e %RSD ≤ 20% para os Fenóis Voláteis). Foram, ainda, realizados estudos de exatidão recorrendo a ensaios de recuperação e a ensaios interlaboratoriais. Muitas vezes conseguem-se boas recuperações, no entanto notam-se maiores dificuldades para o TBA e para o TeCA. Relativamente aos ensaios interlaboratoriais, verificam-se maiores discrepâncias para o 4-EP. Já os restantes contaminantes apresentam resultados, geralmente, satisfatórios (|z-score| ≤ 2).
Resumo:
Trabalho de Projeto de Natureza Científica para obtenção do grau de Mestre em Engenharia Civil
Resumo:
The electrochemical behavior of citalopram was studied by square-wave and square-wave adsorptive-stripping voltammetry (SWAdSV). Citalopram can be reduced and accumulated at a mercury drop electrode, with a maximum peak current intensity being obtained at a potential of approximately -1.25V vs. AgCl/Ag, in an aqueous electrolyte solution of pH 12. A SWAdSV method has been developed for the determination of citalopram in pharmaceutical preparations. The method shows a linear range between 1.0x10-7 and 2.0x10-6 mol L-1 with a limit of detection of 5x10-8 mol L-1 for an accumulation time of 30 s. The precision of the method was evaluated by assessing the repeatability and intermediate precision, achieving good relative standard deviations in all cases (≤2.3%). The proposed method was applied to the determination of citalopram in five pharmaceutical products and the results obtained are in good agreement with the labeled values.
Resumo:
The evaluation of benzene in different environments such as indoor (with and without tobacco smoke), a city area, countryside, gas stations and near exhaust pipes from cars running on different types of fuels was performed. The samples were analyzed using gas chromatography (GC) with flame ionization detection (FID) and tandem mass spectrometric detection (MS/MS) (to confirm the identification of benzene in the air samples). Operating conditions for the GC-MS analysis were optimized as well as the sampling and sample preparation. The results obtained in this work indicate that i) the type of fuel directly influences the benzene concentration in the air. Gasoline with additives provided the highest amount of benzene followed by unleaded gasoline and diesel; ii) the benzene concentration in the gas station was always higher than the advisable limit established by law (5 μg m−3) and during the unloading of gasoline the achieved concentration was 8371 μg m−3; iii) the data from the countryside (Taliscas) and the urban city (Matosinhos) were below 5 μg m−3 except 5 days after a fire on a petroleum refinery plant located near the city; iv) it was proven that in coffee shops where smoking is allowed the benzene concentration is higher (6 μg m−3) than in coffee shops where this is forbidden (4 μg m−3). This method may also be helpful for environmental analytical chemists who use GC-MS/MS for the confirmation or/and quantification of benzene.