900 resultados para Farm Buildings.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Policy makers in the European Union are envisioning the introduction of a community farm animal welfare label which would allow consumers to align their consumption habits with their farm animal welfare preferences. For welfare labelling to be viable the market for livestock products produced to higher welfare standards has to be sufficiently segmented with consumers having sufficiently distinct and behaviourally consistent preferences. The present study investigates consumers’ preferences for meat produced to different welfare standards using a hypothetical welfare score. Data is obtained from a contingent valuation study carried out in Britain. The ordered probit model was estimated using Bayesian inference to obtain mean willingness to pay. We find decreasing marginal WTP as animal welfare levels increase and that people’s preferences for different levels of farm animal welfare are sufficiently differentiated making the introduction of a labelling scheme in the form of a certified rating system appear feasible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lighting and small power will typically account for more than half of the total electricity consumption in an office building. Significant variations in electricity used by different tenants suggest that occupants can have a significant impact on the electricity demand for these end-uses. Yet current modelling techniques fail to represent the interaction between occupant and the building environment in a realistic manner. Understanding the impact of such behaviours is crucial to improve the methodology behind current energy modelling techniques, aiming to minimise the significant gap between predicted and in-use performance of buildings. A better understanding of the impact of occupant behaviour on electricity consumption can also inform appropriate energy saving strategies focused on behavioural change. This paper reports on a study aiming to assess the intent of occupants to switch off lighting and appliances when not in use in office buildings. Based on the Theory of Planned Behaviour, the assessment takes the form of a questionnaire and investigates three predictors to behaviour individually: 1) behavioural attitude; 2) subjective norms; 3) perceived behavioural control. The paper details the development of the assessment procedure and discusses preliminary findings from the study. The questionnaire results are compared against electricity consumption data for individual zones within a multi-tenanted office building. Initial results demonstrate a statistically significant correlation between perceived behavioural control and energy consumption for lighting and small power

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of the surrounding lower buildings on the wind pressure distribution on a high-rise building is investigated by computational fluid dynamics (CFD). When B/H=0.1, it is found that the wind pressure on the windward side was reduced especially on the lower part, but for different layers of surrounding buildings, there was no great difference, which agrees with our previous wind tunnel experiment data. Then we changed the aspect ratio from 0.1 to 2, to represent different airflow regimes: skimming flow (SF), and wake interference (WI). It shows that the average Cp increases when B/H increases. For different air flow regimes, it is found that insignificant difference exists when the number of the building layers is more than 2. From the engineering point of view, it is sufficient to only include the first layer for natural ventilation design by using CFD simulation or wind tunnel experiment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The building sector is one of the highest consumers of energy in the world. This has led to high dependency on using fossil fuel to supply energy without due consideration to its environmental impact. Saudi Arabia has been through rapid development accompanied by population growth, which in turn has increased the demand for construction. However, this fast development has been met without considering sustainable building design. General design practices rely on using international design approaches and features without considering the local climate and aspects of traditional passive design. This is by constructing buildings with a large amount of glass fully exposed to solar radiation. The aim of this paper is to investigate the development of sustainability in passive design and vernacular architecture. Furthermore, it compares them with current building in Saudi Arabia in terms of making the most of the climate. Moreover, it will explore the most sustainable renewable energy that can be used to reduce the environmental impact on modern building in Saudi Arabia. This will be carried out using case studies demonstrating the performance of vernacular design in Saudi Arabia and thus its benefits in terms of environmental, economic and social sustainability. It argues that the adoption of a hybrid approach can improve the energy efficiency as well as reduce the carbon footprint of buildings. This is by combining passive design, learning from the vernacular architecture and implementing innovative sustainable technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper provides a comparative study of the performance of cross-flow and counter-flow M-cycle heat exchangers for dew point cooling. It is recognised that evaporative cooling systems offer a low energy alternative to conventional air conditioning units. Recently emerged dew point cooling, as the renovated evaporative cooling configuration, is claimed to have much higher cooling output over the conventional evaporative modes owing to use of the M-cycle heat exchangers. Cross-flow and counter-flow heat exchangers, as the available structures for M-cycle dew point cooling processing, were theoretically and experimentally investigated to identify the difference in cooling effectiveness of both under the parallel structural/operational conditions, optimise the geometrical sizes of the exchangers and suggest their favourite operational conditions. Through development of a dedicated computer model and case-by-case experimental testing and validation, a parametric study of the cooling performance of the counter-flow and cross-flow heat exchangers was carried out. The results showed the counter-flow exchanger offered greater (around 20% higher) cooling capacity, as well as greater (15%–23% higher) dew-point and wet-bulb effectiveness when equal in physical size and under the same operating conditions. The cross-flow system, however, had a greater (10% higher) Energy Efficiency (COP). As the increased cooling effectiveness will lead to reduced air volume flow rate, smaller system size and lower cost, whilst the size and cost are the inherent barriers for use of dew point cooling as the alternation of the conventional cooling systems, the counter-flow system is considered to offer practical advantages over the cross-flow system that would aid the uptake of this low energy cooling alternative. In line with increased global demand for energy in cooling of building, largely by economic booming of emerging developing nations and recognised global warming, the research results will be of significant importance in terms of promoting deployment of the low energy dew point cooling system, helping reduction of energy use in cooling of buildings and cut of the associated carbon emission.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine the effect of growth of five strains of Salmonella enterica and their isogenic multiply antibiotic-resistant (MAR) derivatives with a phenolic farm disinfectant or triclosan (biocides) upon the frequency of mutation to resistance to antibiotics or cyclohexane. Methods: Strains were grown in broth with or without the biocides and then spread on to agar containing ampicillin, ciprofloxacin or tetracycline each at 4x MIC or agar overlaid with cyclohexane. Incubation was for 24 and 48 h and the frequency of mutation to resistance was calculated for strains with and without prior growth with the biocides. MICs were determined and the presence of mutations in the acrR and marR regions was determined by sequencing and the presence of mutations in gyrA by light-cycler analysis, for a selection of the mutants that arose. Results: The mean frequency of mutation to antibiotic or cyclohexane resistance was increased similar to10- to 100-fold by prior growth with the phenolic disinfectant or triclosan. The increases were statistically significant for all antibiotics and cyclohexane following exposure to the phenolic disinfectant (P less than or equal to 0.013), and for ampicillin and cyclohexane following exposure to triclosan (P less than or equal to 0.009). Mutants inhibited by >1 mg/L ciprofloxacin arose only from strains that were MAR. Reduced susceptibility to ciprofloxacin (at 4x MIC for parent strains) alone was associated with mutations in gyrA. MAR mutants did not contain mutations in the acrR or marR region. Conclusions: These data renew fears that the use of biocides may lead to an increased selective pressure towards antibiotic resistance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: The aim of this study was to determine if three classes of farm disinfectants were able to select for ciprofloxacin or cyclohexane tolerant [ indicative of a multiple antibiotic resistance ( MAR) phenotype] Escherichia coli and if cyclohexane-tolerant E. coli could be isolated from farms. Methods and Results: Chicken slurry containing ca 1 : 99 ratio ciprofloxacin resistant : susceptible E. coli ( 10 different resistant strains examined) was treated for 24 h with each of the disinfectants and examined for survival of resistant : susceptible strains. Ciprofloxacin-sensitive ( n = 5) and - resistant ( n = 5) E. coli were grown with sublethal concentrations of the disinfectants and then plated to agar containing ciprofloxacin or overlaid with cyclohexane. Escherichia coli ( n = 389) isolated from farms were tested for cyclohexane tolerance. Minimum inhibitory concentrations ( MIC) were determined against representative isolates and mutants. The disinfectants did not select for the ciprofloxacin-resistant E. coli in poultry slurry but following growth with each of the three disinfectants, higher numbers ( Pless than or equal to 0(.)023) of cyclohexane-tolerant E. coli were isolated and these had a MAR phenotype. Of the 389 farm E. coli tested, only one was cyclohexane tolerant. Conclusions: It is possible that in a farm environment, E. coli could be exposed to similar concentrations of the disinfectants that are selected for MAR type organisms under these laboratory conditions. Significance and Impact of the Study: Data from this study suggest that cyclohexane-resistant E. coli are not common on farms, but in view of the ease of isolating them in the laboratory with farm disinfectants, further investigations on farms are warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To determine if one passage of Salmonella enterica serovar Typhimurium in the presence of farm disinfectants selected for mutants with decreased susceptibility to disinfectants and/or antibiotics. Methods: Eight Salmonella Typhimurium strains including field isolates and laboratory mutants were exposed to either a tar oil phenol (PFD) disinfectant, an oxidizing compound disinfectant (OXC), an aldehyde based disinfectant (ABD) or a dairy sterilizer disinfectant (based on quaternary ammonium biocide) in agar. The susceptibility of mutants obtained after disinfectant exposure to antibiotics and disinfectants was determined as was the accumulation of norfloxacin. The proteome of SL1344 after exposure to PFD and OXC was analysed using two-dimensional liquid chromatography mass spectrometry. Results: Strains with either acrB or tolC inactivated were more susceptible to most disinfectants than other strains. The majority (3/5) of mutants recovered after disinfectant exposure required statistically significantly longer exposure times to disinfectants than their parent strains to generate a 5 log kill. Small decreases in antibiotic susceptibility were observed but no mutants were multiply antibiotic-resistant (MAR). Notably exposure to ABD decreased susceptibility to ciprofloxacin in some strains. Mutants with increased disinfectant tolerance were able to survive and persist in chicks as well as in parent strains. Analysis of proteomes revealed significantly increased expression of the AcrAB-TolC efflux system after PFD exposure. Conclusions: Data presented demonstrate that efflux pumps are required for intrinsic resistance to some disinfectants and that exposure to disinfectants can induce expression of the AcrAB-TolC efflux system, but that single exposure was insufficient to select for MAR strains.