881 resultados para Enterprise system implementation
Resumo:
It is now widely accepted that separating programs into modules has proven very useful in program development and maintenance. While many Prolog implementations include useful module systems, we feel that these systems can be improved in a number of ways, such as, for example, being more amenable to effective global analysis and allowing sepárate compilation or sensible creation of standalone executables. We discuss a number of issues related to the design of such an improved module system for Prolog. Based on this, we present the choices made in the Ciao module system, which has been designed to meet a number of objectives: allowing sepárate compilation, extensibility in features and in syntax, amenability to modular global analysis, etc.
Resumo:
This paper describes the current prototype of the distributed CIAO system. It introduces the concepts of "teams" and "active modules" (or active objects), which conveniently encapsulate different types of functionalities desirable from a distributed system, from parallelism for achieving speedup to client-server applications. The user primitives available are presented and their implementation described. This implementation uses attributed variables and, as an example of a communication abstraction, a blackboard that follows the Linda model. Finally, the CIAO WWW interface is also briefly described. The unctionalities of the system are illustrated through examples, using the implemented primitives.
Resumo:
This paper describes the current prototype of the distributed CIAO system. It introduces the concepts of "teams" and "active modules" (or active objects), which conveniently encapsulate different types of functionalities desirable from a distributed system, from parallelism for achieving speedup to client-server applications. It presents the user primitives available and describes their implementation. This implementation uses attributed variables and, as an example of a communication abstraction, a blackboard that follows the Linda model. The functionalities of the system are illustrated through examples, using the implemented primitives. The implementation of most of the primitives is also described in detail.
Resumo:
Abstract is not available.
Resumo:
We informally discuss several issues related to the parallel execution of logic programming systems and concurrent logic programming systems, and their generalization to constraint programming. We propose a new view of these systems, based on a particular definition of parallelism. We argüe that, under this view, a large number of the actual systems and models can be explained through the application, at different levéis of granularity, of only a few basic principies: determinism, non-failure, independence (also referred to as stability), granularity, etc. Also, and based on the convergence of concepts that this view brings, we sketch a model for the implementation of several parallel constraint logic programming source languages and models based on a common, generic abstract machine and an intermedíate kernel language.
Resumo:
Abstract is not available.
Resumo:
Las técnicas de cirugía de mínima invasión (CMI) se están consolidando hoy en día como alternativa a la cirugía tradicional, debido a sus numerosos beneficios para los pacientes. Este cambio de paradigma implica que los cirujanos deben aprender una serie de habilidades distintas de aquellas requeridas en cirugía abierta. El entrenamiento y evaluación de estas habilidades se ha convertido en una de las mayores preocupaciones en los programas de formación de cirujanos, debido en gran parte a la presión de una sociedad que exige cirujanos bien preparados y una reducción en el número de errores médicos. Por tanto, se está prestando especial atención a la definición de nuevos programas que permitan el entrenamiento y la evaluación de las habilidades psicomotoras en entornos seguros antes de que los nuevos cirujanos puedan operar sobre pacientes reales. Para tal fin, hospitales y centros de formación están gradualmente incorporando instalaciones de entrenamiento donde los residentes puedan practicar y aprender sin riesgos. Es cada vez más común que estos laboratorios dispongan de simuladores virtuales o simuladores físicos capaces de registrar los movimientos del instrumental de cada residente. Estos simuladores ofrecen una gran variedad de tareas de entrenamiento y evaluación, así como la posibilidad de obtener información objetiva de los ejercicios. Los diferentes estudios de validación llevados a cabo dan muestra de su utilidad; pese a todo, los niveles de evidencia presentados son en muchas ocasiones insuficientes. Lo que es más importante, no existe un consenso claro a la hora de definir qué métricas son más útiles para caracterizar la pericia quirúrgica. El objetivo de esta tesis doctoral es diseñar y validar un marco de trabajo conceptual para la definición y validación de entornos para la evaluación de habilidades en CMI, en base a un modelo en tres fases: pedagógica (tareas y métricas a emplear), tecnológica (tecnologías de adquisición de métricas) y analítica (interpretación de la competencia en base a las métricas). Para tal fin, se describe la implementación práctica de un entorno basado en (1) un sistema de seguimiento de instrumental fundamentado en el análisis del vídeo laparoscópico; y (2) la determinación de la pericia en base a métricas de movimiento del instrumental. Para la fase pedagógica se diseñó e implementó un conjunto de tareas para la evaluación de habilidades psicomotoras básicas, así como una serie de métricas de movimiento. La validación de construcción llevada a cabo sobre ellas mostró buenos resultados para tiempo, camino recorrido, profundidad, velocidad media, aceleración media, economía de área y economía de volumen. Adicionalmente, los resultados obtenidos en la validación de apariencia fueron en general positivos en todos los grupos considerados (noveles, residentes, expertos). Para la fase tecnológica, se introdujo el EVA Tracking System, una solución para el seguimiento del instrumental quirúrgico basado en el análisis del vídeo endoscópico. La precisión del sistema se evaluó a 16,33ppRMS para el seguimiento 2D de la herramienta en la imagen; y a 13mmRMS para el seguimiento espacial de la misma. La validación de construcción con una de las tareas de evaluación mostró buenos resultados para tiempo, camino recorrido, profundidad, velocidad media, aceleración media, economía de área y economía de volumen. La validación concurrente con el TrEndo® Tracking System por su parte presentó valores altos de correlación para 8 de las 9 métricas analizadas. Finalmente, para la fase analítica se comparó el comportamiento de tres clasificadores supervisados a la hora de determinar automáticamente la pericia quirúrgica en base a la información de movimiento del instrumental, basados en aproximaciones lineales (análisis lineal discriminante, LDA), no lineales (máquinas de soporte vectorial, SVM) y difusas (sistemas adaptativos de inferencia neurodifusa, ANFIS). Los resultados muestran que en media SVM presenta un comportamiento ligeramente superior: 78,2% frente a los 71% y 71,7% obtenidos por ANFIS y LDA respectivamente. Sin embargo las diferencias estadísticas medidas entre los tres no fueron demostradas significativas. En general, esta tesis doctoral corrobora las hipótesis de investigación postuladas relativas a la definición de sistemas de evaluación de habilidades para cirugía de mínima invasión, a la utilidad del análisis de vídeo como fuente de información y a la importancia de la información de movimiento de instrumental a la hora de caracterizar la pericia quirúrgica. Basándose en estos cimientos, se han de abrir nuevos campos de investigación que contribuyan a la definición de programas de formación estructurados y objetivos, que puedan garantizar la acreditación de cirujanos sobradamente preparados y promocionen la seguridad del paciente en el quirófano. Abstract Minimally invasive surgery (MIS) techniques have become a standard in many surgical sub-specialties, due to their many benefits for patients. However, this shift in paradigm implies that surgeons must acquire a complete different set of skills than those normally attributed to open surgery. Training and assessment of these skills has become a major concern in surgical learning programmes, especially considering the social demand for better-prepared professionals and for the decrease of medical errors. Therefore, much effort is being put in the definition of structured MIS learning programmes, where practice with real patients in the operating room (OR) can be delayed until the resident can attest for a minimum level of psychomotor competence. To this end, skills’ laboratory settings are being introduced in hospitals and training centres where residents may practice and be assessed on their psychomotor skills. Technological advances in the field of tracking technologies and virtual reality (VR) have enabled the creation of new learning systems such as VR simulators or enhanced box trainers. These systems offer a wide range of tasks, as well as the capability of registering objective data on the trainees’ performance. Validation studies give proof of their usefulness; however, levels of evidence reported are in many cases low. More importantly, there is still no clear consensus on topics such as the optimal metrics that must be used to assess competence, the validity of VR simulation, the portability of tracking technologies into real surgeries (for advanced assessment) or the degree to which the skills measured and obtained in laboratory environments transfer to the OR. The purpose of this PhD is to design and validate a conceptual framework for the definition and validation of MIS assessment environments based on a three-pillared model defining three main stages: pedagogical (tasks and metrics to employ), technological (metric acquisition technologies) and analytical (interpretation of competence based on metrics). To this end, a practical implementation of the framework is presented, focused on (1) a video-based tracking system and (2) the determination of surgical competence based on the laparoscopic instruments’ motionrelated data. The pedagogical stage’s results led to the design and implementation of a set of basic tasks for MIS psychomotor skills’ assessment, as well as the definition of motion analysis parameters (MAPs) to measure performance on said tasks. Validation yielded good construct results for parameters such as time, path length, depth, average speed, average acceleration, economy of area and economy of volume. Additionally, face validation results showed positive acceptance on behalf of the experts, residents and novices. For the technological stage the EVA Tracking System is introduced. EVA provides a solution for tracking laparoscopic instruments from the analysis of the monoscopic video image. Accuracy tests for the system are presented, which yielded an average RMSE of 16.33pp for 2D tracking of the instrument on the image and of 13mm for 3D spatial tracking. A validation experiment was conducted using one of the tasks and the most relevant MAPs. Construct validation showed significant differences for time, path length, depth, average speed, average acceleration, economy of area and economy of volume; especially between novices and residents/experts. More importantly, concurrent validation with the TrEndo® Tracking System presented high correlation values (>0.7) for 8 of the 9 MAPs proposed. Finally, the analytical stage allowed comparing the performance of three different supervised classification strategies in the determination of surgical competence based on motion-related information. The three classifiers were based on linear (linear discriminant analysis, LDA), non-linear (support vector machines, SVM) and fuzzy (adaptive neuro fuzzy inference systems, ANFIS) approaches. Results for SVM show slightly better performance than the other two classifiers: on average, accuracy for LDA, SVM and ANFIS was of 71.7%, 78.2% and 71% respectively. However, when confronted, no statistical significance was found between any of the three. Overall, this PhD corroborates the investigated research hypotheses regarding the definition of MIS assessment systems, the use of endoscopic video analysis as the main source of information and the relevance of motion analysis in the determination of surgical competence. New research fields in the training and assessment of MIS surgeons can be proposed based on these foundations, in order to contribute to the definition of structured and objective learning programmes that guarantee the accreditation of well-prepared professionals and the promotion of patient safety in the OR.
Resumo:
Abstract is not available
Resumo:
We discuss several issues involved in the implementation of ACE, a model capable of exploiting both And-parallelism and Or-parallelism in Prolog in a unified framework. The Orparallel model that ACE employs is based on the idea of stack-copying developed for Muse, while the model of independent And-parallelism is based on the distributed stack approach of &-Prolog. We discuss the organization of the workers, a number of sharing assumtions, techniques for work load detection, and issues relaed to which parts need to be copied when a flexible and-scheduling strategy is used.
Resumo:
This report presents an overview of the current work performed by us in the context of the efficient parallel implementation of traditional logic programming systems. The work is based on the &-Prolog System, a system for the automatic parallelization and execution of logic programming languages within the Independent And-parallelism model, and the global analysis and parallelization tools which have been developed for this system. In order to make the report self-contained, we first describe the "classical" tools of the &-Prolog system. We then explain in detail the work performed in improving and generalizing the global analysis and parallelization tools. Also, we describe the objectives which will drive our future work in this area.
Resumo:
In this work, a fiber-based optical powering (or power-by-light) system capable of providing more than 1 W is developed. The prototype was used in order to power a shunt regulator for controlling the activation and deactivation of solar panels in satellites. The work involves the manufacture of a light receiver (a GaAs multiple photovoltaic converter (MPC)), a power conditioning block, and a regulator and the implementation and characterization of the whole system. The MPC, with an active area of just 3.1 mm2, was able to supply 1 W at 5 V with an efficiency of 30%. The maximum measured device efficiency was over 40% at an input power (Pin) of 0.5 W. Open circuit voltage over 7 V was measured for Pin over 0.5 W. A system optoelectronic efficiency (including the optical fiber, connectors, and MPC) of 27% was measured at an output power (Pout) of 1 W. At Pout = 0.2 W, the efficiency was as high as 36%. The power conditioning block and the regulator were successfully powered with the system. The maximum supplied power in steady state was 0.2 W, whereas in transient state, it reached 0.44 W. The paper also describes the characterization of the system within the temperature range going from -70 to +100?°C.
Resumo:
Descripción y evaluación de sistema de estimulación cognitiva a través de la TDT orientada a personas con enfermedad de Parkinson, con supervisión por parte de sus terapeutas de forma remota. Abstract: This paper details the full design, implementation, and validation of an e-health service in order to improve the community health care services for patients with cognitive disorders. Specifically, the new service allows Parkinson’s disease patients benefit from the possibility of doing cognitive stimulation therapy (CST) at home by using a familiar device such as a TV set. Its use instead of a PC could be a major advantage for some patients whose lack of familiarity with the use of a PC means that they can do therapy only in the presence of a therapist. For these patients this solution could bring about a great improvement in their autonomy. At the same time, this service provides therapists with the ability to conduct follow-up of therapy sessions via the web,benefiting from greater and easier control of the therapy exercises performed by patients and allowing them to customize new exercises in accordance with the particular needs of each patient. As a result, this kind of CST is considered to be a complement of other therapies oriented to the Parkinson patients. Furthermore, with small changes, the system could be useful for patients with a different cognitive disease such as Alzheimer’s or mild cognitive impairment.
Resumo:
The Networks of Evolutionary Processors (NEPs) are computing mechanisms directly inspired from the behavior of cell populations more specifically the point mutations in DNA strands. These mechanisms are been used for solving NP-complete problems by means of a parallel computation postulation. This paper describes an implementation of the basic model of NEP using Web technologies and includes the possibility of designing some of the most common variants of it by means the use of the web page design which eases the configuration of a given problem. It is a system intended to be used in a multicore processor in order to benefit from the multi thread use.
Resumo:
This paper describes an automatic-dependent surveillance-broadcast (ADS-B) implementation for air-to-air and ground-based experimental surveillance within a prototype of a fully automated air traffic management (ATM) system, under a trajectory-based-operations paradigm. The system is built using an air-inclusive implementation of system wide information management (SWIM). This work describes the relations between airborne and ground surveillance (SURGND), the prototype surveillance systems, and their algorithms. System's performance is analyzed with simulated and real data. Results show that the proposed ADS-B implementation can fulfill the most demanding surveillance accuracy requirements.
Resumo:
Many applications in several domains such as telecommunications, network security, large scale sensor networks, require online processing of continuous data lows. They produce very high loads that requires aggregating the processing capacity of many nodes. Current Stream Processing Engines do not scale with the input load due to single-node bottlenecks. Additionally, they are based on static con?gurations that lead to either under or over-provisioning. In this paper, we present StreamCloud, a scalable and elastic stream processing engine for processing large data stream volumes. StreamCloud uses a novel parallelization technique that splits queries into subqueries that are allocated to independent sets of nodes in a way that minimizes the distribution overhead. Its elastic protocols exhibit low intrusiveness, enabling effective adjustment of resources to the incoming load. Elasticity is combined with dynamic load balancing to minimize the computational resources used. The paper presents the system design, implementation and a thorough evaluation of the scalability and elasticity of the fully implemented system.