842 resultados para Electrode position


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Speaking about professionals, working with children at child care homes in Lithuania, first of all we encounter a problem of terminology. This problem rises, because in various countries and languages we call these professionals differently. In Lithuania we call them ”aukletojai”. We also use the word ”aukletojas” when speaking about both professionals, working directly with children at kindergartens, and parents, as all parents are educators of their children. We suppose, that the word ”aukletojas” corresponds to the German “erzieher”, and “aukleti” to “erziehen”. Every “aukletojas” in Lithuania clearly realizes, that he is a pedagogue, because in this country every professional, involved in educational work with children – an ”aukletojas”, a teacher, a social pedagogue and a special pedagogue – is called a pedagogue. In this context it is essential to conceive that in Lithuania an ”educator” and a ”social pedagogue” are different pedagogical professions and that none of the ”aukletojas” identify himself as a social pedagogue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of a high-density active microelectrode array for in vitro electrophysiology is reported. Based on the Active Pixel Sensor (APS) concept, the array integrates 4096 gold microelectrodes (electrode separation 20 microm) on a surface of 2.5 mmx2.5 mm as well as a high-speed random addressing logic allowing the sequential selection of the measuring pixels. Following the electrical characterization in a phosphate solution, the functional evaluation has been carried out by recording the spontaneous electrical activity of neonatal rat cardiomyocytes. Signals with amplitudes from 130 microVp-p to 300 microVp-p could be recorded from different pixels. The results demonstrate the suitability of the APS concept for developing a new generation of high-resolution extracellular recording devices for in vitro electrophysiology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The idea of xMOOCs initially aimed at fundamentally changing the US tertiary education system by providing open mass education. This attempt failed for a number of reasons. They include: the ignorance of the importance and benefits of face-to-face instruction, the high workload imposed on students by xMOOCs, the consequences of current xMOOC didactics, the financing of the high costs, and the difficulties of integration into the teaching organization. As a consequence, xMOOCs are turning into methods for professional continuing education including a business model that covers the institution’s cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have studied Au(55 nm)@SiO2 nanoparticles (NPs) on two low-index phases of gold and platinum single crystal electrodes in ClO4– and SO42– ion-containing electrolytes by both electrochemical methods and in-situ shell-isolated nanoparticle enhanced Raman spectroscopy (SHINERS). We showed the blocking of the electrode with surfactants originating from the synthesis of as-prepared SHINERS NPs. We introduce an efficient procedure to overcome this problem, which provides a fundamental platform for the application of SHINERS in surface electrochemistry and beyond. Our method is based on a hydrogen evolution treatment of the SHINERS-NP-modified single-crystal surfaces. The reliability of our preparation strategy is demonstrated in electrochemical SHINERS experiments on the potential-controlled adsorption and phase formation of pyridine on Au(hkl) and Pt(hkl). We obtained high-quality Raman spectra on these well-defined and structurally carefully characterized single-crystal surfaces. The analysis of the characteristic A1 vibrational modes revealed perfect agreement with the interpretation of single-crystal voltammetric and chronoamperometric experiments. Our study demonstrates that the SHINERS protocol developed in this work qualifies this Raman method as a pioneering approach with unique opportunities for in situ structure and reactivity studies at well-defined electrochemical solid/liquid interfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

HYPOTHESIS A previously developed image-guided robot system can safely drill a tunnel from the lateral mastoid surface, through the facial recess, to the middle ear, as a viable alternative to conventional mastoidectomy for cochlear electrode insertion. BACKGROUND Direct cochlear access (DCA) provides a minimally invasive tunnel from the lateral surface of the mastoid through the facial recess to the middle ear for cochlear electrode insertion. A safe and effective tunnel drilled through the narrow facial recess requires a highly accurate image-guided surgical system. Previous attempts have relied on patient-specific templates and robotic systems to guide drilling tools. In this study, we report on improvements made to an image-guided surgical robot system developed specifically for this purpose and the resulting accuracy achieved in vitro. MATERIALS AND METHODS The proposed image-guided robotic DCA procedure was carried out bilaterally on 4 whole head cadaver specimens. Specimens were implanted with titanium fiducial markers and imaged with cone-beam CT. A preoperative plan was created using a custom software package wherein relevant anatomical structures of the facial recess were segmented, and a drill trajectory targeting the round window was defined. Patient-to-image registration was performed with the custom robot system to reference the preoperative plan, and the DCA tunnel was drilled in 3 stages with progressively longer drill bits. The position of the drilled tunnel was defined as a line fitted to a point cloud of the segmented tunnel using principle component analysis (PCA function in MatLab). The accuracy of the DCA was then assessed by coregistering preoperative and postoperative image data and measuring the deviation of the drilled tunnel from the plan. The final step of electrode insertion was also performed through the DCA tunnel after manual removal of the promontory through the external auditory canal. RESULTS Drilling error was defined as the lateral deviation of the tool in the plane perpendicular to the drill axis (excluding depth error). Errors of 0.08 ± 0.05 mm and 0.15 ± 0.08 mm were measured on the lateral mastoid surface and at the target on the round window, respectively (n =8). Full electrode insertion was possible for 7 cases. In 1 case, the electrode was partially inserted with 1 contact pair external to the cochlea. CONCLUSION The purpose-built robot system was able to perform a safe and reliable DCA for cochlear implantation. The workflow implemented in this study mimics the envisioned clinical procedure showing the feasibility of future clinical implementation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of pressure waves to confirm the correct position of the epidural needle has been described in several domestic species and proposed as a valid alternative to standard methods, namely, control radiographic exam and fluoroscopy. The object of this retrospective clinical study was to evaluate the sensitivity of the epidural pressure waves as a test to verify the correct needle placement in the epidural space in dogs, in order to determine whether this technique could be useful not only in the clinical setting but also when certain knowledge of needle's tip position is required, for instance when performing clinical research focusing on epidural anaesthesia. Of the 54 client-owned dogs undergoing elective surgeries and enrolled in this retrospective study, only 45% showed epidural pressure waves before and after epidural injection. Twenty-six percent of the animals showed epidural pressure waves only after the injection, whereas 29% of the dogs showed epidural pressure waves neither before nor after injection and were defined as false negatives. Our results show that the epidural pressure wave technique to verify epidural needle position lacks sensitivity, resulting in many false negatives. As a consequence, the applicability of this technique is limited to situations in which precise, exact knowledge of the needle's tip position is not mandatory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Digital analysis of the occlusal contacts can be performed with the T-scan device (T Scan III, TekScan, Boston, USA). However, the thickness of the interocclusal T-scan sheet (100 μm) may lead to a displacement of the mandible. Thus, the aim of this study was to investigate the impact of the T-scan sheet on the position of the mandibular condyles in maximum intercuspidation. Twenty dentate subjects with healthy jaw function were enrolled in the study. An ultrasonic axiography device was used to measure the position of the condyles. Ten 3D condyle positions in maximum intercuspidation of the teeth were recorded: first the reference position without the sheet, then 3 times without the sheet, 3 times with the sheet, and finally again 3 times without the sheet. There was a statistically significant difference (Wilcoxon matched pairs test) between the condyle positions with and without the interocclusally positioned T-scan sheet (P < 0.0005). The T-scan device lead to a displacement of the condyles of about 1 mm mainly in ventral direction (P = 0.005). Thus, occlusal analysis is not performed in physiological, maximum intercuspidation. This has to be considered when interpreting the measured contact points.