939 resultados para Electric currents
Resumo:
http://digitalcommons.colby.edu/atlasofmaine2008/1010/thumbnail.jpg
Resumo:
Ed Tilin a graduate of the New York Trade School's Advanced Television program is pictured here as part of the General Electric Company. Original caption reads, "Ed Tilin - Advanced Television 1954, joined G.E. in 1956 and has risen rapidly. He now supervises all television product service, product training and consumer relations activities for the New York district. He is a member of the exemtive [sic] board of CETA (Certified Electronic Technicians Association). Black and white photograph with original caption glued to reverse.
Resumo:
This thesis develops and evaluates a business model for connected full electric vehicles (FEV) for the European market. Despite a promoting political environment, various barriers have thus far prevented the FEV from becoming a mass-market vehicle. Besides cost, the most noteworthy of these barriers is represented by range anxiety, a product of FEVs’ limited range, lacking availability of charging infrastructure, and long recharging times. Connected FEVs, which maintain a constant connection to the surrounding infrastructure, appear to be a promising element to overcome drivers’ range anxiety. Yet their successful application requires a well functioning FEV ecosystem which can only be created through the collaboration of various stakeholders such as original equipment manufacturers (OEM), first tier suppliers (FTS), charging infrastructure and service providers (CISP), utilities, communication enablers, and governments. This thesis explores and evaluates how a business model, jointly created by these stakeholders, could look like, i.e. how stakeholders could collaborate in the design of products, services, infrastructure, and advanced mobility management, to meet drivers with a sensible value proposition that is at least equivalent to that of internal combustion engine (ICE) cars. It suggests that this value proposition will be an end-2-end package provided by CISPs or OEMs that comprises mobility packages (incl. pay per mile plans, battery leasing, charging and battery swapping (BS) infrastructure) and FEVs equipped with an on-board unit (OBU) combined with additional services targeted at range anxiety reduction. From a theoretical point of view the thesis answers the question which business model framework is suitable for the development of a holistic, i.e. all stakeholder-comprising business model for connected FEVs and defines such a business model. In doing so the thesis provides the first comprehensive business model related research findings on connected FEVs, as prior works focused on the much less complex scenario featuring only “offline” FEVs.
Resumo:
Este estudo analisa a integração da sustentabilidade ambiental na estratégia das empresas no contexto da indústria automobilística. A implementação de estratégias de sustentabilidade e o desenvolvimento de veículos híbrido-elétricos são investigados com referência ao caso de um ator principal na indústria. Entre as aplicações de mobilidade eléctrica, que irá aumentar a presença no mercado nos próximos anos devido às regulamentações rigorosas e as preferências dos clientes, a pesquisa está focada em veículos híbrido-elétricos. As estratégias de sustentabilidade das grandes fabricantes de automóveis e as implicações subsequentes em termos de desenvolvimento de produtos, com uma atenção especial aos veículos elétricos híbridos, foram analisados através de dados secundários. Além disso, os dados primários foram coletados sobre a estratégia de sustentabilidade de um ator importante na indústria e usados para realizar um estudo de caso. A análise incidiu sobre os fatores críticos e os aspectos que têm impacto sobre as estratégias de sustentabilidade, que visam reduzir o impacto ambiental da indústria automobilística, e sobre o desenvolvimento de veículos híbridos. A análise dos dados mostrou que a Fiat-Chrysler Automobiles (FCA) teve uma ênfase menor na mobilidade eléctrica em termos de relatórios de sustentabilidade. A conclusão apresenta uma avaliação da estratégia corporativa da FCA, em termos de sustentabilidade ambiental, e apresenta um quadro para o desenvolvimento de veículos híbridos com quatro abordagens diferentes que têm impacto sobre a estratégia de sustentabilidade de uma montadora.
Resumo:
O objetivo deste trabalho foi avaliar as taxas de ativação e de clivagem de oócitos bovinos tratados com estrôncio (10mm de SrCl2), após maturação in vitro por 27-28 horas. No experimento 1, os tratamentos foram: S4 - ativação pelo estrôncio por 4 horas; S12 - ativação pelo estrôncio por 12 horas; S30 - ativação pelo estrôncio por 30 horas; e P - ativação por pulso elétrico (3 pulsos de 1,0kv/cm). No experimento 2 os tratamentos foram: PS4 - ativação combinada pelo pulso elétrico e pelo estrôncio por 4 horas; S4P - ativação pelo estrôncio por 4 horas e pelo pulso elétrico; e PS30 - ativação pelo pulso elétrico e pelo estrôncio por 30 horas. No experimento 1, todos os tratamentos apresentaram taxas similares de ativação (83-90%; P>0,05). Para clivagem, P foi melhor (53%; P<0,05) do que todos os tratamentos com estrôncio (6 a 28%). No experimento 2, o tratamento S4P apresentou melhor taxa de ativação (88%; P<0,05) do que PS4 e PS30 (60 e 68%, respectivamente). Para clivagem, observou-se o mesmo padrão, S4P (65%; P<0,05) e PS4 e PS30 (37% e 44%, respectivamente). Conclui-se que o estrôncio é capaz de ativar oócitos bovinos e sua combinação com pulso elétrico não melhora a ativação. Este é o primeiro relato demonstrando que o estrôncio ativa oócitos bovinos.
Resumo:
Neste trabalho, ajustou-se um modelo matemático para quantificar o efeito do rendimento do motor elétrico sobre os custos de um sistema de bombeamento para irrigação na estrutura tarifária de energia elétrica convencional e horo-sazonal verde, bem como calcular o tempo de recuperação do capital investido no equipamento de maior rendimento. em seguida, o mesmo foi aplicado a um sistema de irrigação tipo pivô central em duas opções de rendimento do motor elétrico: 92,6% (linha padrão) e 94,3% (linha alto rendimento), sendo que o custo de aquisição do primeiro correspondeu a 70% do segundo. A potência do motor elétrico era de 100 cv. Os resultados mostraram que o modelo permitiu avaliar se um motor de alto rendimento era viável economicamente em relação ao motor-padrão em cada estrutura tarifária. Nas duas estruturas tarifárias, o motor de alto rendimento não foi viável. Na tarifa horo-sazonal verde, somente seria viável se seu rendimento fosse 4,46% superior ao do motor-padrão. Na tarifa convencional, somente seria viável se o ganho de rendimento superasse 2,71%.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective. Measure physical therapists' exposure to the electric and magnetic fields produced by 17 shortwave diathermy devices in physical therapy clinics in the city of Presidente Prudente, São Paulo State, Brazil. Compare the observed values with the exposure levels recommended by the International Commission on Non-ionizing Radiation Protection (ICNIRP). Observe the efficacy of Faraday cages as a means of protecting physical therapists from exposure to oscillating electric and magnetic fields.Methods. Electric and magnetic field measurements were taken at four points during actual physical therapy sessions: in proximity to the operator's pelvis and head, the devices' electrical cables, and the electrodes. The measuring equipment was a Wandel & Goltermann EMR-200.Results. The values obtained in proximity to the electrodes and cables were 10 to 30 times higher than ICNIRP's recommended occupational reference levels. In the shortwave diathermy treatment rooms with Faraday cages, the fields were even higher than in treatment rooms not so equipped-principally the magnetic field, where the values were more than 100 times higher than the ICNIRP exposure limit.Conclusions. The electric and magnetic field intensities obtained in this study are generally above the exposure levels recommend in ICNIRP standards. It was also observed that the Faraday cage offers physical therapists no protection, and instead, increases their level of exposure.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The polarization effects of in-plane electric fields and eccentricity on electronic and optical properties of semiconductor quantum rings (QRs) are discussed within the effective-mass approximation. As eccentric rings may appropriately describe real (grown or fabricated) QRs, their energy spectrum is studied. The interplay between applied electric fields and eccentricity is analysed, and their polarization effects are found to compensate for appropriate values of eccentricity and field intensity. The importance of applied fields in tailoring the properties of different nanoscale materials and structures is stressed.
Resumo:
The effects of an in-plane electric field and eccentricity on the electronic spectrum of a GaAs quantum ring in a perpendicular magnetic field are studied. The effective-mass equation is solved by two different methods: an adiabatic approximation and a diagonalization procedure after a conformal mapping. It is shown that the electric field and the eccentricity may suppress the Aharonov-Bohm oscillations of the lower energy levels. Simple expressions for the threshold energy and the number of flat energy bands are found. In the case of a thin and eccentric ring, the intensity of a critical field which compensates the main effects of eccentricity is determined. The energy spectra are found in qualitative agreement with previous experimental and theoretical works on anisotropic rings.
Resumo:
Electron quasi-stationary states in a periodic semiconductor superlattice are calculated, as linear combinations of Wannier-Kohn functions, for different values of an electric field applied along the heterostructure. A comparison with an alternative approach, which is based on the localization of quasi-stationary states, is performed. (C) 2004 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Power performance evaluation of an electric home fan with triac-based automatic speed control system
Resumo:
In order to provide a low cost system of thermal comfort, a common model of home fan, 40 cm diameter size, had its manual four-button control system replaced by an automatic speed control. The new control system has a temperature sensor feeding a microcontroller that, by using an optic coupling, DIAC or TRIAC-based circuit, varies the RMS value of the fan motor input voltage and its speed, according to the room temperature. Over a wide range of velocity, the fan net power and the motor fan input power were measured working under both control system. The temperature of the motor stator and the voltage waveforms were observed too. Measured values analysis showed that the TRIAC-based control system makes the fan motor work at a very low power factor and efficiency values. The worst case is at low velocity range where the higher fan motor stator temperatures were registered. The poor power factor and efficiency and the harmonics signals inserted in the motor input voltage wave by the TRIAC commutation procedure are correlated.
Resumo:
The use of mean values of thermal and electric demand can be justifiable for synthesising the configuration and for estimating the economic results because it simplifies the analysis in a preliminary feasibility study of a cogeneration plant. For determining the cogeneration scheme that best fits the energetic needs of a process several cycles and combinations must be considered, and those technically feasible will be analysed according to economic models. Although interesting for a first approach, this procedure do not consider that the peaks and valleys present in the load patterns will impose additional constraints relatively to the equipment capacities. In this paper, the effects of thermal and electric load fluctuation to the cogeneration plant design were considered. An approach for modelling these load variability is proposed for comparing two competing thermal and electric parity competing schemes. A gas turbine associated to a heat recovery steam generator was then proposed and analysed for thermal- and electric-following operational strategies. Thermal-following option revealed to be more attractive for the technical and economic limits defined for this analysis. (c) 2006 Elsevier Ltd. All rights reserved.