940 resultados para Diagnostic radiology
Resumo:
BACKGROUND: Numerous studies suggest that Internet-based self-help treatments are effective in treating anxiety disorders. Trials evaluating such interventions differ in their screening procedures and in the amount of clinician contact in the diagnostic assessment phase. The present study evaluates the impact of a pre-treatment diagnostic interview on the outcome of an Internet-based treatment for Social Anxiety Disorder (SAD). METHOD: One hundred and nine participants seeking treatment for SAD were randomized to either an interview-group (IG, N = 53) or to a non-interview group (NIG, N = 56). All participants took part in the same 10-week cognitive-behavioural unguided self-help programme. Before receiving access to the programme, participants of the IG underwent a structured diagnostic interview. Participants of the NIG started directly with the programme. RESULTS: Participants in both groups showed significant and substantial improvement on social anxiety measures from pre- to post-assessment (d IG = 1.30-1.63; d NIG = 1.00-1.28) and from pre- to 4-month follow-up assessment (d IG = 1.38-1.87; d NIG = 1.10-1.21). Significant between-groups effects in favour of the IG were found on secondary outcome measures of depression and general distress (d = 0.18-0.42). CONCLUSIONS: These findings suggest that Internet-based self-help is effective in treating SAD, whether or not a diagnostic interview is involved. However, the pre-treatment interview seems to facilitate change on secondary outcomes such as depression and general distress.
Resumo:
In recent years, implementation of 68Ga-radiometalated peptides for PET imaging of cancer has attracted the attention of clinicians. Herein, we propose the use of 44Sc (half-life = 3.97 h, average β+ energy [Eβ+av] = 632 keV) as a valuable alternative to 68Ga (half-life = 68 min, Eβ+av = 830 keV) for imaging and dosimetry before 177Lu-based radionuclide therapy. The aim of the study was the preclinical evaluation of a folate conjugate labeled with cyclotron-produced 44Sc and its in vitro and in vivo comparison with the 177Lu-labeled pendant. Methods: 44Sc was produced via the 44Ca(p,n)44Sc nuclear reaction at a cyclotron (17.6 ± 1.8 MeV, 50 μA, 30 min) using an enriched 44Ca target (10 mg 44CaCO3, 97.00%). Separation from the target material was performed by a semiautomated process using extraction chromatography and cation exchange chromatography. Radiolabeling of a DOTA-folate conjugate (cm09) was performed at 95°C within 10 min. The stability of 44Sc-cm09 was tested in human plasma. 44Sc-cm09 was investigated in vitro using folate receptor–positive KB tumor cells and in vivo by PET/CT imaging of tumor-bearing mice Results: Under the given irradiation conditions, 44Sc was obtained in a maximum yield of 350 MBq at high radionuclide purity (>99%). Semiautomated isolation of 44Sc from 44Ca targets allowed formulation of up to 300 MBq of 44Sc in a volume of 200–400 μL of ammonium acetate/HCl solution (1 M, pH 3.5–4.0) within 10 min. Radiolabeling of cm09 was achieved with a radiochemical yield of greater than 96% at a specific activity of 5.2 MBq/nmol. In vitro, 44Sc-cm09 was stable in human plasma over the whole time of investigation and showed folate receptor–specific binding to KB tumor cells. PET/CT images of mice injected with 44Sc-cm09 allowed excellent visualization of tumor xenografts. Comparison of cm09 labeled with 44Sc and 177Lu revealed almost identical pharmacokinetics. Conclusion: This study presents a high-yield production and efficient separation method of 44Sc at a quality suitable for radiolabeling of DOTA-functionalized biomolecules. An in vivo proof-of-concept study using a DOTA-folate conjugate demonstrated the excellent features of 44Sc for PET imaging. Thus, 44Sc is a valid alternative to 68Ga for imaging and dosimetry before 177Lu-radionuclide tumor therapy.
Resumo:
We have used the “Discussion Board” feature of an online classroom application (Blackboard) to present diagnostic questions for our advanced practice nursing students in their course on differential diagnosis. [See PDF for complete abstract]
Resumo:
In the present study, we wanted to (1) evaluate whether high-sensitive troponin T levels correlate with the grade of renal insufficiency and (2) test the accuracy of high-sensitive troponin T determination in patients with renal insufficiency for diagnosis of acute myocardial infarction (AMI). In this cross-sectional analysis, all patients who received serial measurements of high-sensitive troponin T from August 1, 2010, to October 31, 2012, at the Department of Emergency Medicine were included. We analyzed data on baseline characteristics, reason for referral, medication, cardiovascular risk factors, and outcome in terms of presence of AMI along with laboratory data (high-sensitive troponin T, creatinine). A total of 1,514 patients (67% male, aged 65 ± 16 years) were included, of which 382 patients (25%) had moderate to severe renal insufficiency and significantly higher levels of high-sensitive troponin T on admission (0.028 vs 0.009, p <0.0001). In patients without AMI, high-sensitive troponin T correlated inversely with the estimated glomerular filtration rate (R = -0.12, p <0.0001). Overall, sensitivity of an elevated high-sensitive troponin for diagnosis of AMI was 0.64 (0.56 to 0.71) and the specificity was 0.48 (0.45 to 0.51). The area under the curve of the receiver operating characteristic for all patients was 0.613 (standard error [SE] 0.023), whereas it was 0.741 (SE 0.029) for patients with a Modification of Diet in Renal Disease estimated glomerular filtration rate >60 ml/min presenting with acute chest pain or dyspnea and 0.535 (SE 0.056) for patients with moderate to severe renal insufficiency presenting with acute chest pain or dyspnea. In conclusion, the diagnostic accuracy for presence of AMI of a baseline measurement of high-sensitive troponin in patients with renal insufficiency was poor and resembles tossing a coin.
Resumo:
Introduction: First Trimester Screening (FTS) combines maternal age with fetal nuchal translucency (NT) and maternal analytes to identify pregnancies at an increased risk for Down syndrome and trisomy 18. Though the accuracy of this screening is high, it cannot replace the conclusive accuracy of prenatal diagnostic testing (PDT). Since FTS has been available, a decrease in the number of women who pursue PDT has been observed. This study sought to determine if there has been a significant change in the amount of PDT performed in our clinics, if the type of FTS result affects the patient’s decision regarding PDT, and what the patient’s intentions are regarding PDT. Material and Methods: A database review was performed for the two years prior and the two years after the January 2007 American College of Obstetricians and Gynecologists (ACOG) guidelines regarding FTS were issued. We compared the number of women who were AMA and the number of women who were AMA and had PDT between those time periods. We also determined the number of positive and negative FTS results, and determined how many of those patients had PDT. Finally, we surveyed our patients and referring physicians to determine: what the patient understands about FTS, what the patient’s intentions are regarding FTS, and how physicians present the option of FTS to their patients. Results: We determined that there was a 19.6% decrease in the amount of PDT performed when we compared the two time periods at our three specified clinics. Many of our patients were against having PDT prior to their genetic counseling session, but after they received genetic counseling, 76% of our population became open to the possibility of having PDT. Conclusion: Similar to previous studies, we determined that there has been a significant decrease in the number of PDT procedures performed at our clinics, which coincides with the release of the January 2007 ACOG statement regarding FTS. While our patients regarded FTS as a way to gain early information about their pregnancy in a non-invasive manner, they also stated they would use their results as a way to aid in their decision regarding PDT.
Resumo:
Le consensus 2012 sur le diagnostic et le traitement des patients atteints de démence en Suisse a été élaboré par une conférence d’experts qui s’est déroulée du 23 au 25 mars 2012 à Lucerne. Après revue des données scientifiques récentes, les auteurs ont rédigé un projet qui a été soumis à de nombreux experts de la démence en Suisse dans le cadre d’une procédure de consultation. Après adaptation et révisions du document initial en fonction des remarques exprimées, l’ensemble des spécialistes consultés et les membres du groupe d’experts adhèrent expressément aux prises de position énoncées dans ce document. La conférence d’experts a été financée par le Forum Alzheimer Suisse.
Resumo:
OBJECTIVE: We sought to evaluate the performance of the human papillomavirus high-risk DNA test in patients 30 years and older. MATERIALS AND METHODS: Screening (n=835) and diagnosis (n=518) groups were defined based on prior Papanicolaou smear results as part of a clinical trial for cervical cancer detection. We compared the Hybrid Capture II (HCII) test result with the worst histologic report. We used cervical intraepithelial neoplasia (CIN) 2/3 or worse as the reference of disease. We calculated sensitivities, specificities, positive and negative likelihood ratios (LR+ and LR-), receiver operating characteristic (ROC) curves, and areas under the ROC curves for the HCII test. We also considered alternative strategies, including Papanicolaou smear, a combination of Papanicolaou smear and the HCII test, a sequence of Papanicolaou smear followed by the HCII test, and a sequence of the HCII test followed by Papanicolaou smear. RESULTS: For the screening group, the sensitivity was 0.69 and the specificity was 0.93; the area under the ROC curve was 0.81. The LR+ and LR- were 10.24 and 0.34, respectively. For the diagnosis group, the sensitivity was 0.88 and the specificity was 0.78; the area under the ROC curve was 0.83. The LR+ and LR- were 4.06 and 0.14, respectively. Sequential testing showed little or no improvement over the combination testing. CONCLUSIONS: The HCII test in the screening group had a greater LR+ for the detection of CIN 2/3 or worse. HCII testing may be an additional screening tool for cervical cancer in women 30 years and older.
Resumo:
Virtual colonoscopy (VC) is a minimally invasive means for identifying colorectal polyps and colorectal lesions by insufflating a patient’s bowel, applying contrast agent via rectal catheter, and performing multi-detector computed tomography (MDCT) scans. The technique is recommended for colonic health screening by the American Cancer Society but not funded by the Centers for Medicare and Medicaid Services (CMS) partially because of potential risks from radiation exposure. To date, no in‐vivo organ dose measurements have been performed for MDCT scans; thus, the accuracy of any current dose estimates is currently unknown. In this study, two TLDs were affixed to the inner lumen of standard rectal catheters used in VC, and in-vivo rectal dose measurements were obtained within 6 VC patients. In order to calculate rectal dose, TLD-100 powder response was characterized at diagnostic doses such that appropriate correction factors could be determined for VC. A third-order polynomial regression with a goodness of fit factor of R2=0.992 was constructed from this data. Rectal dose measurements were acquired with TLDs during simulated VC within a modified anthropomorphic phantom configured to represent three sizes of patients undergoing VC. The measured rectal doses decreased in an exponential manner with increasing phantom effective diameter, with R2=0.993 for the exponential regression model and a maximum percent coefficient of variation (%CoV) of 4.33%. In-vivo measurements yielded rectal doses ranged from that decreased exponentially with increasing patient effective diameter, in a manner that was also favorably predicted by the size specific dose estimate (SSDE) model for all VC patients that were of similar age, body composition, and TLD placement. The measured rectal dose within a younger patient was favorably predicted by the anthropomorphic phantom dose regression model due to similarities in the percentages of highly attenuating material at the respective measurement locations and in the placement of the TLDs. The in-vivo TLD response did not increase in %CoV with decreasing dose, and the largest %CoV was 10.0%.
Resumo:
Background. A nonrecognized pneumothorax (PTX) may become a life-threatening tension PTX. A reliable point-of-care diagnostic tool could help in reduce this risk. For this purpose, we investigated the feasibility of the use of the PneumoScan, an innovative device based on micropower impulse radar (MIR). Patients and Methods. addition to a standard diagnostic protocol including clinical examination, chest X-ray (CXR), and computed tomography (CT), 24 consecutive patients with chest trauma underwent PneumoScan testing in the shock trauma room to exclude a PTX. Results. The application of the PneumoScan was simple, quick, and reliable without functional disorder. Clinical examination and CXR each revealed one and PneumoScan three out of altogether four PTXs (sensitivity 75%, specificity 100%, positive predictive value 100%, and negative predictive value 95%). The undetected PTX did not require intervention. Conclusion. The PneumoScan as a point-of-care device offers additional diagnostic value in patient management following chest trauma. Further studies with more patients have to be performed to evaluate the diagnostic accuracy of the device.
Resumo:
Nuclear morphometry (NM) uses image analysis to measure features of the cell nucleus which are classified as: bulk properties, shape or form, and DNA distribution. Studies have used these measurements as diagnostic and prognostic indicators of disease with inconclusive results. The distributional properties of these variables have not been systematically investigated although much of the medical data exhibit nonnormal distributions. Measurements are done on several hundred cells per patient so summary measurements reflecting the underlying distribution are needed.^ Distributional characteristics of 34 NM variables from prostate cancer cells were investigated using graphical and analytical techniques. Cells per sample ranged from 52 to 458. A small sample of patients with benign prostatic hyperplasia (BPH), representing non-cancer cells, was used for general comparison with the cancer cells.^ Data transformations such as log, square root and 1/x did not yield normality as measured by the Shapiro-Wilks test for normality. A modulus transformation, used for distributions having abnormal kurtosis values, also did not produce normality.^ Kernel density histograms of the 34 variables exhibited non-normality and 18 variables also exhibited bimodality. A bimodality coefficient was calculated and 3 variables: DNA concentration, shape and elongation, showed the strongest evidence of bimodality and were studied further.^ Two analytical approaches were used to obtain a summary measure for each variable for each patient: cluster analysis to determine significant clusters and a mixture model analysis using a two component model having a Gaussian distribution with equal variances. The mixture component parameters were used to bootstrap the log likelihood ratio to determine the significant number of components, 1 or 2. These summary measures were used as predictors of disease severity in several proportional odds logistic regression models. The disease severity scale had 5 levels and was constructed of 3 components: extracapsulary penetration (ECP), lymph node involvement (LN+) and seminal vesicle involvement (SV+) which represent surrogate measures of prognosis. The summary measures were not strong predictors of disease severity. There was some indication from the mixture model results that there were changes in mean levels and proportions of the components in the lower severity levels. ^
Resumo:
BACKGROUND Although well-established for suspected lower limb deep venous thrombosis, an algorithm combining a clinical decision score, d-dimer testing, and ultrasonography has not been evaluated for suspected upper extremity deep venous thrombosis (UEDVT). OBJECTIVE To assess the safety and feasibility of a new diagnostic algorithm in patients with clinically suspected UEDVT. DESIGN Diagnostic management study. (ClinicalTrials.gov: NCT01324037) SETTING: 16 hospitals in Europe and the United States. PATIENTS 406 inpatients and outpatients with suspected UEDVT. MEASUREMENTS The algorithm consisted of the sequential application of a clinical decision score, d-dimer testing, and ultrasonography. Patients were first categorized as likely or unlikely to have UEDVT; in those with an unlikely score and normal d-dimer levels, UEDVT was excluded. All other patients had (repeated) compression ultrasonography. The primary outcome was the 3-month incidence of symptomatic UEDVT and pulmonary embolism in patients with a normal diagnostic work-up. RESULTS The algorithm was feasible and completed in 390 of the 406 patients (96%). In 87 patients (21%), an unlikely score combined with normal d-dimer levels excluded UEDVT. Superficial venous thrombosis and UEDVT were diagnosed in 54 (13%) and 103 (25%) patients, respectively. All 249 patients with a normal diagnostic work-up, including those with protocol violations (n = 16), were followed for 3 months. One patient developed UEDVT during follow-up, for an overall failure rate of 0.4% (95% CI, 0.0% to 2.2%). LIMITATIONS This study was not powered to show the safety of the substrategies. d-Dimer testing was done locally. CONCLUSION The combination of a clinical decision score, d-dimer testing, and ultrasonography can safely and effectively exclude UEDVT. If confirmed by other studies, this algorithm has potential as a standard approach to suspected UEDVT. PRIMARY FUNDING SOURCE None.
Resumo:
AIMS: We conducted a meta-analysis to evaluate the accuracy of quantitative stress myocardial contrast echocardiography (MCE) in coronary artery disease (CAD). METHODS AND RESULTS: Database search was performed through January 2008. We included studies evaluating accuracy of quantitative stress MCE for detection of CAD compared with coronary angiography or single-photon emission computed tomography (SPECT) and measuring reserve parameters of A, beta, and Abeta. Data from studies were verified and supplemented by the authors of each study. Using random effects meta-analysis, we estimated weighted mean difference (WMD), likelihood ratios (LRs), diagnostic odds ratios (DORs), and summary area under curve (AUC), all with 95% confidence interval (CI). Of 1443 studies, 13 including 627 patients (age range, 38-75 years) and comparing MCE with angiography (n = 10), SPECT (n = 1), or both (n = 2) were eligible. WMD (95% CI) were significantly less in CAD group than no-CAD group: 0.12 (0.06-0.18) (P < 0.001), 1.38 (1.28-1.52) (P < 0.001), and 1.47 (1.18-1.76) (P < 0.001) for A, beta, and Abeta reserves, respectively. Pooled LRs for positive test were 1.33 (1.13-1.57), 3.76 (2.43-5.80), and 3.64 (2.87-4.78) and LRs for negative test were 0.68 (0.55-0.83), 0.30 (0.24-0.38), and 0.27 (0.22-0.34) for A, beta, and Abeta reserves, respectively. Pooled DORs were 2.09 (1.42-3.07), 15.11 (7.90-28.91), and 14.73 (9.61-22.57) and AUCs were 0.637 (0.594-0.677), 0.851 (0.828-0.872), and 0.859 (0.842-0.750) for A, beta, and Abeta reserves, respectively. CONCLUSION: Evidence supports the use of quantitative MCE as a non-invasive test for detection of CAD. Standardizing MCE quantification analysis and adherence to reporting standards for diagnostic tests could enhance the quality of evidence in this field.
Resumo:
Within the past 15 years, significant advances in the imaging of multiorgan and complex trauma primarily due to the improvement of cross-sectional imaging have resulted in the optimization of the expedient diagnosis and management of the polytrauma patient. At the forefront, multidetector computed tomography (MDCT) has become the cornerstone of modern emergency departments and trauma centers. In many institutions, MDCT is the de facto diagnostic tool upon trauma activation. In the setting of pelvic imaging, MDCT (with its high spatial resolution and sensitivity as well as short acquisition times) allows for rapid identification and assessment of pelvic hemorrhage leading to faster triage and definitive management. In trauma centers throughout the world, angiography and minimally invasive catheter-based embolization techniques performed by interventional radiologists have become the standard of care for patients with acute pelvic trauma and related multiorgan hemorrhage. In an interdisciplinary setting, embolization may be performed either alone or as an adjunct procedure with open or closed reduction and stabilization techniques. A team-based approach involving multiple disciplines (e.g., radiology, traumatology, orthopedic surgery, intensive care medicine) is crucial to monitor and treat the actively bleeding patient appropriately.
Resumo:
Introduction The purpose of this paper is to present the technical specifications of the Forensic Reference Phantom (FRP), to test its behavior relative to organic test materials, and discuss potential applications of the phantom in forensic radiology. Materials and method The FRP prototype is made of synthetic materials designed to simulate the computed tomography (CT) attenuation of water. It has six bore holes that accommodate multiuse containers. These containers were filled with test materials and scanned at 80 kVp, 120 kVp, and 140 kVp. X-ray attenuation was measured by two readers. Intra- and inter-reader reliability was assessed using the intra-class correlation coefficient (ICC). Significance levels between mean CT numbers at 80 kVp, 120 kVp, and 140 kVp were assessed with the Friedman-test. The T-test was used to assess significance levels between the FRP and water. Results Overall mean CT numbers ranged from −3.0–3.7HU for the FRP; −1000.3–−993.5HU for air; −157.7– −108.1HU for oil; 35.5–42.0HU for musle tissue; and 1301.5–2354.8HU for cortical bone. Inter-reader and intra-reader reliability were excellent (ICC>0.994; and ICC=0.999 respectively). CT numbers were significantly different at different energy levels. There was no significant difference between the attenuation of the FRP and water. Conclusions The FRP is a new tool for quality assurance and research in forensic radiology. The mean CT attenuation of the FRP is equivalent to water. The phantom can be scanned during routine post-mortem CT to assess the composition of unidentified objects. In addition, the FRP may be used to investigate new imaging algorithms and scan protocols in forensic radiology.