935 resultados para Dental Care for Chronically Ill
Resumo:
This study investigated the clinical factors associated with a wish to hasten death among patients with advanced cancer receiving palliative care, with a focus on the role of clinician-related factors. Patients were grouped into high- and low-scoring groups on the basis of their wish to hasten death; doctor-patient pairs were formed. Questionnaire data collected from patients and their treating doctors were subjected to multivariate analysis. Significant predictors of a high wish to hasten death in terminally ill patients from among treating clinicians included the clinician's perception of the patient's lower optimism and greater emotional suffering, the patient indicating a wish to hasten death, the doctor willing to assist the patient in hastening death (if requested and legal), and the doctor reporting less training in psychotherapy. When these variables were combined with patient factors identified in a previous study, the model significantly predicted a wish to hasten death with the following variables patient factors: a higher perceived burden on others, higher depressive symptom scores, and lower family cohesion; physician factors: the doctor willing to assist the patient in hastening death (if requested and legal), the doctor's perception of lower levels of optimism and greater emotional distress in the patient, and the doctor having less training in psychotherapy; and the setting of care: recent admission to a hospice. The findings support the multifactorial influences on the wish to hasten death and suggest that the role of the clinician is a vital context within which the wish to hasten death should be considered.
Resumo:
Objective: To assess the outcomes for a group of elderly patients with mental illness following their discharge from a stand-alone psychiatric facility to seven extended care units (ECUs). Method: All patients (n = 60) who were relocated to the ECUs were assessed using a number of standardized clinical and general functioning instruments at 6 months and 6 weeks pre-move, and again at 6 weeks, 6 months and 18 months post-move. Results: By 18 months post-discharge, 13 of the 60 patients (21.7%) had died and seven others had been transferred to nursing homes. Those who died were older and had significantly higher levels of physical ill health when compared to those who did not die. Changes on measures of clinical and behavioural functioning in those who remained in the study did not reach statistical significance by 18 months post-move. However, participants did demonstrate improvements in quality of life with significantly higher scores on measures of social contact and community access. Conclusions: The mortality observed in the follow-up period is likely to be related to physical ill health and old age rather than the trauma associated with relocation. While overall functioning did not improve following relocation, patients had more independence and greater access to community-based activities.
Resumo:
Objective: Few data have been published regarding protein losing enteropathy in adult patients with burns. This study characterised the presence of protein-losing enteropathy in adults with burns and examined the relationship between the magnitude of bum size and the severity of protein loss. Methods: Twenty adult patients with burns (BSA 31+/-25%, range 2-80%) were studied. Fluid resuscitation was based on the Parkland's formula. Protein loss into the gastrointestinal tract was measured using faecal alpha(1)-antitrypsin (FA-1-AT) concentrations. Serial measurements of serum protein and albumin concentrations were performed. Results: Fourteen patients demonstrated elevations in FA-1-AT levels. The mean peak FA-1-AT level was 3.6+/-4.2 mg/g dry weight of stool. Two patients demonstrated elevated FA-1-AT excretion 1.5 months and 3 months after the bums. There was a good correlation between burn size and FA-1-AT excretion (R-2=0.40). Conclusions: Protein losing enteropathy was demonstrable in patients with major burns. The magnitude of this phenomenon appears to be proportional to the burns size.
Resumo:
This study aimed to investigate whether fluid shifts alter ciprofloxacin pharmacokinetics in critically ill patients over time. Patients >= 18 years, with normal renal function, requiring intensive care treatment and parenteral antibiotics were enrolled. Group A (22 patients) included patients with documented intra-abdominal infections. Group B (18 patients) included patients with severe sepsis from other causes. All patients received intravenous ciprofloxacin 400 mg every 8 h infused over 60 min. Eight timed blood specimens were taken on days 0, 2 and 7. Ciprofloxacin plasma concentrations were determined using high performance liquid chromatography. There were no significant differences between the pharmacokinetics of the two groups or over time. Ciprofloxacin pharmacokinetics in critically ill patients do not change over time, and intra-abdominal sepsis does not alter ciprofloxacin pharmacokinetic parameters to a greater degree than sepsis from other causes in critically ill patients. (c) 2005 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.
Resumo:
It is unclear whether a random plasma cortisol measurement and the corticotropin (ACTH) test adequately reflect glucocorticoid secretory capacity in critical illness. This study aimed to determine whether these tests provide information representative of the 24 hour period. Plasma cortisol was measured hourly for 24 hours in 21 critically ill septic patients followed by a corticotropin test with 1 μ g dose administered intravenously. Serum and urine were analysed for ACTH and free cortisol respectively. Marked hourly variability in plasma cortisol was evident (coefficient of variation 8-30%) with no demonstrable circadian rhythm. The individual mean plasma cortisol concentrations ranged from 286 59 nmol/l to 796 &PLUSMN; 83 nmol/l. The 24 hour mean plasma cortisol was strongly correlated with both random plasma cortisol (r(2) 0.9, P< 0.0001) and the cortisol response to corticotropin (r(2) 0.72, P< 0.001). Only nine percent of patients increased their plasma cortisol by 250 nmol/l after corticotropin (euadrenal response). However, 35% of non-responders had spontaneous hourly rises > 250 nmol/l thus highlighting the limitations of a single point corticotropin test. Urinary free cortisol was elevated (865&PLUSMN; 937 nmol) in both corticotropin responders and non-responders suggesting elevated plasma free cortisol. No significant relationship was demonstrable between plasma cortisol and ACTH. We conclude that although random cortisol measurements and the low dose corticotropin tests reliably reflect the 24 hour mean cortisol in critical illness, they do not take into account the pulsatile nature of cortisol secretion. Consequently, there is the potential for erroneous conclusions about adrenal function based on a single measurement. We suggest that caution be exercised when drawing conclusions on the adequacy of adrenal function based on a single random plasma cortisol or the corticotropin test.
Resumo:
The clinical use of potent, well-tolerated, broad-spectrum antibiotics has been paralleled by the development of resistance in bacteria, and the prevalence of highly resistant bacteria in some intensive care units is despairingly commonplace. The intensive care community faces the realistic prospect of untreatable nosocomial infections and should be searching for new approaches to diagnose and manage resistant bacteria. In this review, we discuss some of the relevant underlying biology, with a particular focus on genetic transfer vehicles and the relationship of selection pressure to their movements. It is an attempt to demystify the relevant language and concepts for the anaesthetist and intensivist, to explain some of the reasons for the emergence of resistance in bacteria, and to provide a contextual basis for discussion of management approaches such as selective decontamination and antibiotic cycling.
Resumo:
Aim. The paper presents a study assessing the rate of adoption of a sedation scoring system and sedation guideline. Background. Clinical practice guidelines including sedation guidelines have been shown to improve patient outcomes by standardizing care. In particular sedation guidelines have been shown to be beneficial for intensive care patients by reducing the duration of ventilation. Despite the acceptance that clinical practice guidelines are beneficial, adoption rates are rarely measured. Adoption data may reveal other factors which contribute to improved outcomes. Therefore, the usefulness of the guideline may be more appropriately assessed by collecting adoption data. Method. A quasi-experimental pre-intervention and postintervention quality improvement design was used. Adoption was operationalized as documentation of sedation score every 4 hours and use of the sedation and analgesic medications suggested in the guideline. Adoption data were collected from patients' charts on a random day of the month; all patients in the intensive care unit on that day were assigned an adoption category. Sedation scoring system adoption data were collected before implementation of a sedation guideline, which was implemented using an intensive information-giving strategy, and guideline adoption data were fed back to bedside nurses. After implementation of the guideline, adoption data were collected for both the sedation scoring system and the guideline. The data were collected in the years 2002-2004. Findings. The sedation scoring system was not used extensively in the pre-intervention phase of the study; however, this improved in the postintervention phase. The findings suggest that the sedation guideline was gradually adopted following implementation in the postintervention phase of the study. Field notes taken during the implementation of the sedation scoring system and the guideline reveal widespread acceptance of both. Conclusion. Measurement of adoption is a complex process. Appropriate operationalization contributes to greater accuracy. Further investigation is warranted to establish the intensity and extent of implementation required to positively affect patient outcomes.
Resumo:
To examine the effect of an algorithm-based sedation guideline developed in a North American intensive care unit (ICU) on the duration of mechanical ventilation of patients in an Australian ICU. The intervention was tested in a pre-intervention, post-intervention comparative investigation in a 14-bed adult intensive care unit. Adult mechanically ventilated patients were selected consecutively (n =322) The pre-intervention and post-intervention groups were similar except for a higher number of patients with a neurological diagnosis in the pre-intervention group. An algorithm-based sedation guideline including a sedation scale was introduced using a multifaceted implementation strategy. The median duration of ventilation was 5.6 days in the post-intervention group, compared with 4.8 days for the pre-intervention group (P = 0.99). The length of stay was 8.2 days in the post-intervention group versus 7.1 days in the pre-intervention group (P = 0.04). There were no statistically significant differences for the other secondary outcomes, including the score on the Experience of Treatment in ICU 7 item questionnaire, number of tracheostomies and number of self-extubations. Records of compliance to recording the sedation score during both phases revealed that patients were slightly more deeply sedated when the guideline was used. The use of the algorithm-based sedation guideline did not reduce duration of mechanical ventilation in the setting of this study.
Resumo:
Objective: To compare the total plasma cortisol values obtained from three widely used immunoassays and a high pressure liquid chromatography (HPLC) technique on samples obtained from patients with sepsis. Design and setting: Observational interventional in the general intensive care unit of a metropolitan hospital. Patients and participants: Patients admitted to the intensive care unit with a diagnosis of sepsis and fulfilling criteria of systemic inflammatory response syndrome. Interventions: Standard short synacthen test performed with 250 mu g cosyntropin. Measurements and results: Two of the three immunoassays returned results significantly higher than those obtained by HPLC: Immulite by 95% (95%CI 31-188%) and TDx by 79% (21-165%). The limits of agreement for all three immunoassays with HPLC ranged from -62% to 770%. In addition, by classifying the patients into responders and non-responders to ACTH by standard criteria there was concordance in all assays in only 44% of patients. Conclusions: Immunoassay estimation of total plasma cortisol in septic patients shows wide assay related variation that may have significant impact in the diagnosis of relative adrenal insufficiency.