978 resultados para Dental Amalgam


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate and compare the roughness and superficial morphology of enamel and a composite restorative resin after different bleaching techniques application. Material and Methods: Bovine incisors were selected and standardized cavities were prepared on the buccal surface, which were restored with composite resin. The teeth were distributed according to the following treatments: G1- bleaching with 10% carbamide peroxide (CP); G2 - bleaching with 38% hydrogen peroxide (HP); and G3 - bleaching with 38% of HP associated to light irradiation. For G1, the bleaching gel was applied for 8 hours daily during 21 days. For G2 and G3, 3 sessions were performed, consisting of 3 applications of 15 minutes each, with 7 days of intervals between the sessions. For G3, the LED (470nm) light was used to activate the bleaching agent for 6 minutes. The surface of enamel and composite resin were evaluated before and after the bleaching procedures using a roughness tester and an atomic force microscope. Results: The results showed significant differences in surface roughness of enamel after bleaching only for G1 (Wilcoxon, p<0.05). For composite resin, neither group showed a statistical difference compared to control (Mann-Whitney, p>0.05). Conclusion: It was concluded that the increase in the roughness of enamel occurred only after bleaching therapy using a gel with 10% of CP. The bleaching procedures evaluated in this investigation did not increase the roughness or cause changes in the superficial morphology of the composite resin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: In clinical situations where severe bone resorption has occurred following tooth loss, implant treatment options may comprise either a previous bone reconstruction or only the use of short implants. Objective: This non-systematic review summarizes and discusses some aspects of the use of short implants, such as: biomechanical aspects, success rate, longevity and surgical-prosthetic planning. Literature review: Current and relevant references were selected in order to compare short dental implants to conventional ones. Several studies have highlighted the great importance of wide-diameter implants. Dental short implants have shown high predictability and success rates when some biomechanical aspects are taken into consideration. Conclusion: Placement of short dental implants is a viable treatment method for patients with decreased bone height.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to mechanical and aesthetic improvement properties, continuous fiber-reinforced composites have been developed to replace the metal framework in fixed partial dentures becoming an interesting alternative to conventional treatments. A male patient, 57 years old, attended at Fixed Partial Denture Clinic of Araraquara Dental School - UNESP, complaining about upper right first molar absence. After clinical examination, it was observed: upper right second molar with amalgam restoration and periodontal bone reduction and upper right second premolar unsatisfactory treated. Following the clinical conditions and the patient expectations, it was decided to use a fiber-reinforced composite resin to make a three-element fixed bridge. The patient showed full satisfaction with the aesthetic and functional results. The case has been followed up for 60 months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports the experimental evaluation of physical and gas permeation parameters of four spinel-based investments developed with or without inclusion of sacrificial fillers. Data were compared with those of three commercial formulations. Airflow tests were conducted from 27 to 546°C, and permeability coefficients were fitted from Forchheimer's equation. Skeletal densities found for spinel- (ρs = 3635 ± 165 kg/m3) and phosphate-bonded (ρs = 2686 ± 11 kg/m3) samples were in agreement with the literature. The developed investments were more porous and less permeable than commercial brands, and the differences were ascribed to the different pore morphologies and hydraulic pore sizes of ceramic matrices. The inclusion of both fibers and microbeads resulted in increases of total porosity (42.6–56.6%) and of Darcian permeability coefficient k1 (0.76 × 10−14–7.03 × 10−14 m2). Air permeation was hindered by increasing flow temperatures, and the effect was related to the influence of gas viscosity on ΔP, in accordance with Darcy's law. Casting quality with molten titanium (CP Ti) was directly proportional to the permeability level of the spinel-based investments. However, the high reactivity of the silica-based investment RP and the formation of α-case during casting hindered the benefits of the highest permeability level of this commercial brand.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Temporomandibular disorders (TMD) are recognized as one of the mostcontroversial topics in dentistry, despite the fact that both basic science and clinicalresearchers have currently reached some degree of consensus. This study aimed toconduct a questionnaire-based survey about the management of TMD patients bygeneral dental practitioners (GDPs).Materials and Methods: One hundred fifty-one GDPs with a private practice in a cityof southern Brazil were included, independent of school of origin, gender, graduationyear, and curriculum content. All participants were administered a questionnaire aboutthe management of patients with TMD, and the responses were analyzed by binomialand chi-square tests (α = 0.05).Results: Of the GDPs, 88.7% received TMD patients, who were primarily diagnosedon the basis of medical history (36.6%) or physical examination (30.4%). Of these,65.4% referred the patients elsewhere, primarily to specialists in occlusion (36.1%) ororthodontics (29.7%). Occlusal splinting was the most commonly used managementmodality (20.8%), followed by occlusal adjustment (18.1%) and pharmacotherapy(16.6%). Splints were fabricated in maximum habitual intercuspation or centric re-lation depending on individual patient (54.8%). The hard stabilization form was themost common type of appliance used (35.0%). Moreover, 73.8% of the GDPs didnot employ semi-adjustable articulators, and 69.5% adjusted the appliances at thetime of fixing. The duration of splint use and the frequency of follow-up were con-sidered patient dependent by 62.1% and 72.8%, respectively. GDPs considered thetwo major TMD etiologic categories as multifactorial (20.8%) and occlusion (19.9%).Multidisciplinary medical and dental treatment was considered necessary by 97.9%.Conclusions: The evaluated general dental practitioners manage TMD patients ac-cording to international guidelines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to review the literature on the systems used to decontaminate the implant's surface. Different instruments have been proposed, but there is no agreement in the literature about which methods would be more efficient with no damage to the implant surface. It was reported the use of plastic, carbon fiber, stainless-steel and titanium curettes and also the use of other systems such as ultrasonic points with different tips, rubber cups and air abrasion. Literature review: In most of the studies, the injury caused on the titanium surface at the time of instrumentation was examined. In others, the cell adhesion on the titanium dental implants following instrumentation of the implant surface was observed. Moreover, to enhance cleaning around implants, ultrasonic systems were recently tested. Conclusion: Metal instruments can lead to major damage to implant surface, therefore, they are not indicated for decontamination of dental implants surfaces. Furthermore, non-metallic instruments, such as plastic curettes, rubber cups, air abrasion and some ultrasonic systems seem to be better choices to remove calculus and plaque of the sub- and supra-gingival peri-implant area. It is noteworthy that more studies evaluating the effects of these systems are required to establish best practices to be used in the treatment of patients with dental implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeicoamento de Pessoal de Nivel Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study evaluated the effect of 10% sodium ascorbate (10SA), in gel (10SAg) or aqueous solution (10SAs) formulations, on fracture resistance of endodontically treated tooth submitted to dental bleaching procedures with 15% hydrogen peroxide associated with titanium dioxide (15HP-TiO2) nanoparticles and photoactivated by LED-laser. Material and methods: Forty maxillary premolars were endodontically-treated and embedded in acrylic resin up to the cement-enamel junction. The specimens were divided into four groups (n=10): G1 (negative control): no bleaching, coronal access restored with composite resin; G2 (positive control): three dental bleaching sessions using 15HP-TiO2 and LED-laser photoactivation and restored with composite resin (positive control); G3 (10SAg): similar procedures to G2, but applied 10SA, in gel formulation, for 24 hours before restoration; G4 (10SAs): similar procedures to G3, but applied 10SA, in aqueous solution formulation. The 15HP-TiO2 was applied on buccal and lingual surfaces of the crown tooth and inside the pulp chamber and photoactivated by LED-laser. Between each bleaching session, the teeth were maintained in artificial saliva, at 37oC, for 7 days. In sequence, the teeth were submitted to fracture resistance testing using an eletromechanical machine test. The data was analyzed using Kruskal Wallis test (p = 0.05) Results: There are no differences significant among the groups in relation to fracture resistance of endodontically treated teeth (p>0.05). Conclusions: The use of 10% sodium ascorbate, in gel or aqueous solution formulations, did not interfered on the fracture resistance teeth after dental bleaching using 15HP-TiO2 and LED-laser photoactivation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the correlation of color change on bleaching tooth through delta E (ΔE) by the spectrophotometer Spectroshade (SS) and digital program Scanwhite (SW). Methods: 25 patient volunteers were recruited from Operative Dentistry at Universidad de Chile Dental School, between 18 to 30 years, with good oral hygiene. Exclusion criteria: Previous experienced tooth bleaching, anterior restorations, cervical lesions, pain dental, pregnant patient, stained teeth, malposition of the teeth and periodontal pathology. The bleaching was made in two sessions with three different bleaching systems which were randomly. The assessment of color change through ΔE was made on the two upper central incisors (N=50) by the SS and SW. The color in the same teeth were measured before (T0) and after (T1) of the bleaching treatment. Data were analyzed using test Spearman correlation coefficient (Rho) with a significant level of 95%. Results: The results showed a positive and significant correlation (0.676), with a statistically significant difference (p<0.05). Conclusion: There is correlation in the measurement of color change on bleaching tooth by SS and SW.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ideally projected to be applied on soft tissues, infrared lasers were improved by restorative dentistry to be used in hard dental tissues cavity preparations-namely enamel and dentin. This paper evidentiates the relevant aspects of infrared Erbium laser's action mechanism and its effects, and characterizes the different effects deriving from the laser's beams emission. The criteria for use and selection of optimal parameters for the correct application of laser systems and infuence of supporting factors on the process, such as water amount and its presence in the ablation process, protection exerted by the plasma shielding and structural factors, which are indispensable in dental tissues cavity preparation related to restorative technique, are subordinated to optical modifcations caused by the interaction of the energy dissipated by these laser light emission systems in the targeted tissue substrate. Clinical relevance: Differences in the action of infrared Erbium laser system in regard to the nature of the ablation process and variations on the morphological aspects observed in the super-fcial structure of the target tissue irradiated, may be correlated to the structural optical modifcations of the substrate produced by an interaction of the energy propagated by laser systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The laser has been widely used in many specialties of dentistry and several wavelengths have been investigated as a substitute for high-speed handpiece. The purpose of this paper is to review the literature about the use of Er:YAG and Er,Cr:YSGG lasers in cavity preparation for dental tissues. Despite the differences in wavelength, pulse duration and energy, the morphological characteristics of the irradiated dentin surface with these lasers are comparable, as well as its effects as methods of dental caries prevention. Thus, Er:YAG and Er,Cr:YSGG lasers prepared cavities with similar effects on the dental tissue, however, further investigations about ideal irradiation conditions are needed for both lasers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the surface roughness of 5 indirect restorative materials treated with hydrofluoric acid to 10%, with aluminum oxide jet and a combination of both. The specimens was prepared with 10 mm in diameter and 2 mm thickness, divided into fi ve groups: (1) Ceromer (CeseadII-Kuraray), (2) Leucite crystals ceramics (IPS EmpressIIIvoclarforcasket), (3) glass ceramic with fluorapatite (IPS D. Sign-Ivoclar), (4) lithium disilicate ceramic (IPS Empress II-Ivoclar restorations), (5) ceramics (Cergogold-Degussa). For all groups were performed the controls, and the surfaces with the 3 types of treatment. For testing roughness used the rugosimeter Taylor/Hobson-Precision, model form tracerSV-C525 high sensitivity. After confi rmation of variance analysis with a signifi cance level of 1% (p < 0.01), there was equality between the average roughness of materials from groups 1, 3 and 5, and the group 2 was different from the others. It was also found that the ceramics of the group 5 behaved similar to group 4. However the lowest average roughness was observed in group 2 ceramic. In the evaluation between the types of treatment, the aluminum oxide jet and associations and blasting with hydrofl uoric acid were similar, and different isolated hydrofl uoric acid, and 3 types of treatment signifi cantly higher than the control group. All treatments promoted superfi cial alterations in all tested materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In-office dental bleaching has been subject of several studies. Generally those studies quantify through visual analysis, the shade reduction of the teeth submitted to different bleaching protocols (light sources, bleaching agent concentrations and irradiation time). The objective of this work is the determination of the influence of four irradiation protocols on the obtainment of better aesthetic results using a colorimetric spectrophotometer that quantifies color changes in each situation imposed. Forty bovine incisors were selected in function of similar anatomic characteristics; a concentrated coffee solution was used to stain the teeth. A commercial spectrophotometer was used to measure the color changes during evolution of the experiment (stain and bleaching phases) and the obtained data was analyzed by the ANOVA test. The obtained data showed the evolution of teeth color during the staining period, as well as, the color reduction that each bleaching protocol achieved. Based on our findings it is possible to conclude that bleaching protocols with larger irradiation periods did not showed significant differences when compared with shorter irradiation protocols, in that way the use of protocols with 30 min or more of consecutive irradiation are not clinically justified and also can cause several side effects.