991 resultados para Composting heat extraction unit


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Concerning catheter-related infections, many studies have been conducted until the last consensus conference of the Sociétéde réanimation de langue française (SRLF) in 1994. This text is the synthesis of the considerable amount of work performed by the experts of the society to review recent studies. The experts' texts as well as extensive bibliography are available at http://www.srlf.org.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are growing concerns on long-term health consequences, notably on fertility rates, of plasticizers such as phthalates. While di(2-ethylhexyl)phthalate (DEHP) is currently used in several medical devices, newborns in the neonatal intensive care unit are both more exposed and more vulnerable to DEHP. The objectives of this study were to identify, count, and describe possible sources of DEHP in a neonatal care unit. Our method consisted in the listing and the inspection of the information on packaging, complemented by contact with manufacturers when necessary. According to the results, 6% of all products and 10% of plastic products contained some DEHP; 71% of these involved respiratory support devices. A vast majority of the items showed no information on the content of DEHP. Further research is needed, particularly to determine the effects of such an early exposure and to study and develop safer alternatives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiative heat exchange at the nanoscale presents a challenge for several areas due to its scope and nature. Here, we provide a thermokinetic description of microscale radiative energy transfer including phonon-photon coupling manifested through a non-Debye relaxation behavior. We show that a lognormal-like distribution of modes of relaxation accounts for this non-Debye relaxation behavior leading to the thermal conductance. We also discuss the validity of the fluctuation-dissipation theorem. The general expression for the thermal conductance we obtain fits existing experimental results with remarkable accuracy. Accordingly, our approach offers an overall explanation of radiative energy transfer through micrometric gaps regardless of geometrical configurations and distances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim  Avoiding 'mini-laparotomy' to extract a colectomy specimen may decrease wound complications and further improve recovery after laparoscopic surgery. The aim of this study was to develop a new technique for transrectal specimen extraction (TRSE) and to compare it with conventional laparoscopy (CL) for left sided colectomy. Method  Eleven patients with benign disease requiring either sigmoid or left colon resection underwent TRSE. The unfired circular stapler was inserted transanally and used as a guide to suture-close the recto-sigmoid junction laparoscopically and as a handle to pull the sutured sigmoid through the opened rectum inside a laparoscopic camera bag. The anvil was inserted into the lumen of the intussuscepted sigmoid and pushed to the level of the anastomosis. The anastomosis was fashioned end-to-end in the first patients and side-to-end in the following patients to improve safety. Intra-operative and postoperative outcomes of patients undergoing TRSE were compared with those of a group of 20 patients undergoing CL, who were matched for type of resection, body mass index and age. Results  The procedure was successful in all but the first patient who was converted to conventional laparoscopic colectomy without any additional morbidity. Two patients in the end-to-end anastomosis group, but none in the side-to-end group, developed peri-anastomotic sepsis. Compared with CL, patients undergoing TRSE did not show any significant differences in operative time, recovery or morbidity. Conclusion  Transrectal specimen extraction after left colectomy using the circular stapler technique is feasible. A side-to-end anastomosis appears safer than an end-to-end anastomosis. Further studies are needed to explore the potential advantages of this procedure over CL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Audit report on the Iowa Lottery Authority, a component unit of the State of Iowa, as of and for the year ended June 30, 2015

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Audit report of Iowa State University of Science and Technology, Ames, Iowa, (Iowa State University) and its discretely presented component unit as of and for the years ended June 30, 2015 and 2014

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combined Heat and Power (CHP) refers to the onsite production of electricity and thermal energy from the same fuel source. Integrating power and thermal energy production is more efficient than separate generating systems and used in the right situation can yield several benefits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combined Heat and Power (CHP) refers to the onsite production of electricity and thermal energy from the same fuel source. Integrating power and thermal energy production is more efficient than separate generating systems and used in the right situation can yield several benefits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction and aim: Children hospitalised in a paediatric intensive care unit (PICU) are mainly fed by nutritional support (NS) which may often be interrupted. The aims of the study were to verify the relationship between prescribed (PEI) and actual energy intake (AEI) and to identify the reasons for NS interruption. Methods: Prospective study in a PICU. PEI and AEI from day 1 to 15, type of NS (enteral, parenteral, mixed), position of the feeding tube, interruptions in NS and reasons for these were noted. Inter - ruptions were classified in categories of barriers and their frequency and duration were analysed. Results: Fifteen children (24 ± 25.2 months) were studied for 84 days. The NS was exclusively enteral (69%) or mixed (31%). PEI were significantly higher than AEI (54.7 ± 32.9 vs 49.2 ± 33.6 kcal/kg, p = 0.0011). AEI represented 93% of the PEI. Ninety-eight interruptions were noted and lasted 189 h, i.e. 9.4% of the evaluated time. The most frequent barriers were nursing procedures, respiratory physiotherapy and unavailability of intravenous access. The longest were caused by the necessity to stop NS for surgery or diagnostic studies, to treat burns or to carry out medical procedures. Conclusion: AEI in PICU were inferior by 7% to PEI, considerably lower than in adult studies. Making these results available to medical staff for greater anticipation and compensation could reduce NS interruptions. Starving protocols should be reconsidered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Medication errors in hospitalsmay occur at any step of the medication process including prescription, transcription, preparation and administration, and may originate with any of the actors involved. Neonatal intensive care units (NICU) take care of extremely frail patients in whom errors could have dramatic consequences. Our objective was to assess the frequency and nature of medication errors in the NICU of a university hospital in order to propose measures for improvement.Materials & Methods The design was that of an observational prospective study over 4 consecutivemonths. All patients receiving C 3drugs were included. For each patient, observations during the different stages were compiled in a computer formulary and compared with the litterature. Setting: The 11-bed NICU of our university hospital.Main outcome measures:(a) Frequency and nature of medication errors in prescription,transcription, preparation and administration.(b) Drugs affected by errors.Results 83 patients were included. 505 prescriptions and transcriptions, 447 preparations and 464 administrations were analyzed. 220 medications errors were observed: 102 (46.4%) at prescription, 25 (11.4%) at transcription, 19 (8.6%) at preparation and 73 (33.2%) at administration. Uncomplete/ambiguous orders (24; 23.5%) were the most common errors observed at prescription, followed by wrong name (21; 20.6%), wrong dose (17; 16.7%) and omission (15; 14.7%). Wrong time (33; 45.2%) and wrong administration technique (31; 42.5%) were the most important medication errors during administration. According to the ATC classification, systemic antibacterials (53; 24.1%) were the most implicated, followed by perfusion solutions (40; 18.2%), respiratory system products (30; 13.6%), and mineral supplements and antithrombotic agents (20; 9.1%).Discussions, Conclusion Proposed recommendations: ? Better teaching of neonatal prescription to medical interns;? Improved prescription form to avoid omissions and ambiguities;? Development of a neonatal drug formulary, including prescription,preparation and administration modalities to reduce errors at different stages;? Presence of a clinical pharmacist in the NICU.Disclosure of Interest None Declared