997 resultados para Complete test suites


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Skin patch test is the gold standard method in diagnosing contact allergy. Although used for more than 100 years, the patch test procedure is performed with variability around the world. A number of factors can influence the test results, namely the quality of reagents used, the timing of the application, the patch test series (allergens/haptens) that have been used for testing, the appropriate interpretation of the skin reactions or the evaluation of the patient's benefit. METHODS We performed an Internet -based survey with 38 questions covering the educational background of respondents, patch test methods and interpretation. The questionnaire was distributed among all representatives of national member societies of the World Allergy Organization (WAO), and the WAO Junior Members Group. RESULTS One hundred sixty-nine completed surveys were received from 47 countries. The majority of participants had more than 5 years of clinical practice (61 %) and routinely carried out patch tests (70 %). Both allergists and dermatologists were responsible for carrying out the patch tests. We could observe the use of many different guidelines regardless the geographical distribution. The use of home-made preparations was indicated by 47 % of participants and 73 % of the respondents performed 2 or 3 readings. Most of the responders indicated having patients with adverse reactions, including erythroderma (12 %); however, only 30 % of members completed a consent form before conducting the patch test. DISCUSSION The heterogeneity of patch test practices may be influenced by the level of awareness of clinical guidelines, different training backgrounds, accessibility to various types of devices, the patch test series (allergens/haptens) used for testing, type of clinical practice (public or private practice, clinical or research-based institution), infrastructure availability, financial/commercial implications and regulations among others. CONCLUSION There is a lack of a worldwide homogeneity of patch test procedures, and this raises concerns about the need for standardization and harmonization of this important diagnostic procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Data on new predictors of outcome include penumbra core or collaterals.Objective: To test the predictive value of recanalization, collaterals, penumbra and core of ischemia for functional outcome in a large group of patients with MCA occlusion. Method: Consecutive events included prospectively in the Acute Stroke Registry and Analysis of Lausanne from April 2002 to April 2009 with an acute stroke due to proximal MCA occlusion (M1) were considered for analysis. Acute CTA were reviewed to grade the collaterals (dichotomized in poor __50% or good _50% compared to the normal side) and localization of M1 occlusion (proximal or mid-distal). Acute CTP were reviewed and reconstructed to determine penumbra, core and stroke index (penumbra/penumbra_core) of brain ischemia. Good outcome was defined by mRS 0-2 at 3 months.Results: Among 242 events (115 male, mean NIHSS 18.1, SD 5.8, mean age 66, SD 15), 42% were treated with intravenous thrombolysis, and 3% with intraarterial thrombolysis. Collateral status was rated as poor in 53% of events and proximal M1 occlusion was present in 64%. Recanalization determined at 24 hours with CTA was complete in 26% events and partial/absent in 54%.CTP was available for 212 events. Mean penumbra was 88.6 cm3 (median 84.4, SD 53.8), mean core was 54.1 cm3 (median 46.2, SD 45.7) and stroke index was 64% (median 68%, SD 25%). Good outcome was observed in 87 events (36%) and was associated in multivariate logistic regression with thrombolysis (p_0.02, OR_2.5, 95% CI 1.2-5.4), recanalization (p_0.001, OR_4.1, 95% CI 1.9-8.9), lower NIHSS (p_0.001, OR_0.84, 95% CI 0.78-0.91), male gender (p_0.01, OR_2.8, 95% CI 1.3-5.9), mRS prior to stroke (p_0.02, OR_0.5, 95% CI 0.28-0.9) and good collateral status (p_0.005, OR_3, 95% CI 1.4-6.4). Nor penumbra, nor core, nor stroke index were significant in the multivariate model, even if an association was present in the univariate model between good functional outcome and penumbra (p_0.004, OR_1.008, 95% CI 1.003-1.01), core (p_0.001, OR_0.98, 95% CI 0.976-0.99) and strokeindex (p_0.001, OR_16.7, 95% CI 4.6 59.9).Conclusion: MCA recanalization is the best predictor for good functional outcome, followed by collateral status. CTP data did not predict the functional outcome in our large group of M1 occlusion. Author Disclosures: C. Odier: None. P. Michel: Research Grant; Significant; Paion, Lundbeck. Speakers; Modest; Boehringer-Ingelheim. Consultant/Advisory Board; Modest; Boehringer- Ingelheim. Consultant/Advisory Board; Significant; Servier, Lundbeck.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the effect of incremental increases in intraocular straylight on threshold measurements made by three modern forms of perimetry: Standard Automated Perimetry (SAP) using Octopus (Dynamic, G-Pattern), Pulsar Perimetry (PP) (TOP, 66 points) and the Moorfields Motion Displacement Test (MDT) (WEBS, 32 points).Methods: Four healthy young observers were recruited (mean age 26yrs [25yrs, 28yrs]), refractive correction [+2 D, -4.25D]). Five white opacity filters (WOF), each scattering light by different amounts were used to create incremental increases in intraocular straylight (IS). Resultant IS values were measured with each WOF and at baseline (no WOF) for each subject using a C-Quant Straylight Meter (Oculus, Wetzlar, Germany). A 25 yr old has an IS value of ~0.85 log(s). An increase of 40% in IS to 1.2log(s) corresponds to the physiological value of a 70yr old. Each WOFs created an increase in IS between 10-150% from baseline, ranging from effects similar to normal aging to those found with considerable cataract. Each subject underwent 6 test sessions over a 2-week period; each session consisted of the 3 perimetric tests using one of the five WOFs and baseline (both instrument and filter were randomised).Results: The reduction in sensitivity from baseline was calculated. A two-way ANOVA on mean change in threshold (where subjects were treated as rows in the block and each increment in fog filters was treated as column) was used to examine the effect of incremental increases in straylight. Both SAP (p<0.001) and Pulsar (p<0.001) were significantly affected by increases in straylight. The MDT (p=0.35) remained comparatively robust to increases in straylight.Conclusions: The Moorfields MDT measurement of threshold is robust to effects of additional straylight as compared to SAP and PP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Creació d'una aplicació web que genera exàmens tipus test agafant les preguntes d'un banc de preguntes. Genera una versió per cada alumne del mateix exàmen, amb les preguntes desordenades i les opcions també desordenades. A cada resposta se li associa un número. El resultat de l'exàmen és la suma de les repostes. Mitjançant el criptosistema Knapsack ficant a l'aplicació el número resultat de l'exàmen s'obté la nota.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most ventricular assist devices (VADs) currently used in infants are extracorporeal. These VADs require long-term anticoagulation therapy and extensive surgery, and two devices are needed for biventricular support. We designed a biventricular assist device based on shape memory alloy that reproduces the hemodynamic effects of cardiomyoplasty, supporting the heart with a compressing movement, and evaluated its performance in a dedicated mockup system. Nitinol fibers are the device's key component. Ejection fraction (EF), cardiac output (CO), and generated systolic pressure were measured on a test bench. Our test bench settings were a preload range of 0-15 mm Hg, an afterload range of 0-160 mm Hg, and a heart rate (HR) of 20, 30, 40, and 60 beats/min. A power supply of 15 volts and 3.5 amperes was necessary. The EF range went from 34.4% to 1.2% as the afterload and HR increased, along with a CO from 180 to 6 ml/min. The device generated a maximal systolic pressure of 25 mm Hg. Cardiac compression for biventricular assistance in child-sized heart using shape memory alloy is technically feasible. Further testing remains necessary to assess this VAD's in vivo performance range and its reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lab tests are frequently used in primary care to guide patient care. This is particularly the case when a severe disorder, or one that will affect patients' initial care, needs to be excluded rapidly. At the PMU-FLON walk-in clinic the use of HIV testing as recommended by the Swiss Office of Public Health was hampered by the delay in obtaining test results. This led us to introduce rapid HIV testing which provides results within 30 minutes. Following the first 250 tests the authors discuss the results as well as the benefits of rapid HIV testing in an urban walk-in clinic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims and objectives  This study aimed to determine the discriminant validity and the test-retest reliability of a questionnaire testing the impact of evidence-based medicine (EBM) training on doctors' knowledge and skills. Methods  Questionnaires were sent electronically to all doctors working as residents and chief residents in two French speaking hospital networks in Switzerland. Participants completed the questionnaire twice, within a 4-week interval. The discriminant validity was examined in comparing doctors' performance according to their reported EBM previous training. Proportion of agreement between both sessions of the questionnaire, Cohen's kappa and 'uniform kappa' determined its test-retest reliability. Results  The participation rate was 9.8%/7.1% to first/second session. Performance increased according to the level of doctors' previous training in EBM. The observed proportion of agreement between both sessions was over 70% for 14/19 questions, and the 'uniform kappa' was superior to 0.60 for 15/19 questions. Conclusion  The discriminant validity and test-retest reliability of the questionnaire were satisfying. The low participation rate did not prevent the study from achieving its aims.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Topological indices have been applied to build QSAR models for a set of 20 antimalarial cyclic peroxy cetals. In order to evaluate the reliability of the proposed linear models leave-n-out and Internal Test Sets (ITS) approaches have been considered. The proposed procedure resulted in a robust and consensued prediction equation and here it is shown why it is superior to the employed standard cross-validation algorithms involving multilinear regression models

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND:: Although cell therapy is a promising approach after cerebral cortex lesion, few studies assess quantitatively its behavioral gain in non-human primates. Furthermore, implantations of fetal grafts of exogenous stem cells are limited by safety and ethical issues. OBJECTIVE:: To test in non-human primates the transplantation of autologous adult neural progenitor cortical cells with assessment of functional outcome. METHODS:: Seven adult macaque monkeys were trained to perform a manual dexterity task, before the hand representation in motor cortex was chemically lesioned unilaterally. Five monkeys were used as control, compared to two monkeys subjected to different autologous cells transplantation protocols performed at different time intervals. RESULTS:: After lesion, there was a complete loss of manual dexterity in the contralesional hand. The five "control" monkeys recovered progressively and spontaneously part of their manual dexterity, reaching a unique and definitive plateau of recovery, ranging from 38% to 98% of pre-lesion score after 10 to 120 days. The two "treated" monkeys reached a first spontaneous recovery plateau at about 25 and 40 days post-lesion, representing 35% and 61% of the pre-lesion performance, respectively. In contrast to the controls, a second recovery plateau took place 2-3 months after cell transplantation, corresponding to an additional enhancement of functional recovery, representing 24 and 37% improvement, respectively. CONCLUSIONS:: These pilot data, derived from two monkeys treated differently, suggest that, in the present experimental conditions, autologous adult brain progenitor cell transplantation in non-human primate is safe and promotes enhancement of functional recovery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En el present treball es pretén determinar si existeix una correlació entre la dislèxia (dificultat en l'aprenentatge de la lectura i l'escriptura) i els resultats en el test IGF (intel·ligència general i factorial), concretament els resultats d'eficàcia. Es va seleccionar una mostra d'alumnes a la que, en primer lloc, es va diagnosticar o descartar la dislèxia, i després se'ls-hi va administrar l'IGF. No es van observar diferències significatives en els resultats d'eficàcia del test IGF entre dislèxics i no-dislèxics en dits resultats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the long-term results of 18 chemotherapy relapsed indolent (N = 12) or transformed (N = 6) NHL patients of a phase II anti-CD20 (131)I-tositumomab (Bexxar) therapy study. The biphasic therapy included two injections of 450 mg unlabelled antibody combined with (131)I-tositumomab once as dosimetric and once as therapeutic activity delivering 75 or 65 cGy whole-body radiation dose to patients with normal or reduced platelet counts, respectively. Two patients were not treated due to disease progression during dosimetry. The overall response rate was 81% in the 16 patients treated, including 50% CR/CRu and 31% PR. Median progression free survival of the 16 patients was 22.5 months. Median overall survival has not been reached after a median observation of 48 months. Median PFS of complete responders (CR/CRu) has not been reached and will be greater than 51 months. Short-term side effects were mainly haematological and transient. Among the relevant long-term side effects, one patient previously treated with CHOP chemotherapy died from secondary myelodysplasia. Four patients developed HAMA. In conclusion, (131)I-tositumomab RIT demonstrated durable responses especially in those patients who achieved a complete response. Six of eight CR/CRu are ongoing after 46-70 months.