848 resultados para Chlorate reduction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Continuous intraperitoneal insulin infusion (CIPII) with the DiaPort system using regular insulin was compared to continuous subcutaneous insulin infusion (CSII) using insulin Lispro, to investigate the frequency of hypoglycemia, blood glucose control, quality of life, and safety.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The formation of substituted 2-pyrrolidinones and indoles by the reduction of the secondary nitro group in appropriate 3-aryl-2-methylene-4-nitroalkanoates afforded by Baylis-Hillman chemistry via different reducing agents is described. The 3-aryl-2-methylene-4-nitroalkanoate obtained from SN2 nucleophilic reaction between the acetate of Baylis-Hillman adducts and ethyl nitroacetate upon reduction with indium-HCl furnishes a mixture of cis and trans substituted phenyl-3-methylene-2-pyrrolidinones. In contrast, similar reductions of analogous substrates derived from nitroethane stereoselectively furnished only the trans substituted phenyl-3-methylene-2-pyrrolidinones. On the other hand the SnCl2.2H2O-promoted reductions of substrates derived from nitro ethylacetate give oxime derivatives while the ones obtained from nitroethane yield a mixture of cis and trans 4-aryl-3-methylene-2-pyrrolidinones. Alternatively, the SnCl2.2H2O-promoted reduction of substituted 2-nitrophenyl-2-methylene-alkanoate furnished from ethyl nitroacetate yields 3-(1-alkoxycarbonyl-vinyl)-1H-indole-2-carboxylate while indium-promoted reaction of this substrate leads to a complex mixture. Analogous reactions with SnCl2.2H2O of substituted 2-nitrophenyl-2-methylene-alkanoate obtained from nitroethane yield 4-alkyl-3-methylene-2-quinolones in moderate yields

Relevância:

20.00% 20.00%

Publicador:

Resumo:

At the Chair of Logistics Engineering, TU Dresden, a particular focus is research and development of magnetic traction sheaves. Therein the main fundamentals of these special sheaves are determined for applications in different fields such as elevators, several kinds of winches, hoists and cranes. In the current research project “energy balance of magnetic traction sheaves”, the dynamic behaviour of systems with magnetic traction sheaves was investigated. The research focused on theoretical and practical examinations of energy balance. Moreover, a new approach for dimensioning magnetic traction sheave systems is presented. It is a project of the Research Foundation Intralogistics / Material Handling and Logistics (IFL), which is funded through the AiF under the program of Industrial Collective Research for SMEs (IGF) by the Federal Ministry of Economics and Technology (BMWi).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES This study sought to report the final 5 years follow-up of the landmark LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) trial. BACKGROUND The LEADERS trial is the first randomized study to evaluate biodegradable polymer-based drug-eluting stents (DES) against durable polymer DES. METHODS The LEADERS trial was a 10-center, assessor-blind, noninferiority, "all-comers" trial (N = 1,707). All patients were centrally randomized to treatment with either biodegradable polymer biolimus-eluting stents (BES) (n = 857) or durable polymer sirolimus-eluting stents (SES) (n = 850). The primary endpoint was a composite of cardiac death, myocardial infarction (MI), or clinically indicated target vessel revascularization within 9 months. Secondary endpoints included extending the primary endpoint to 5 years and stent thrombosis (ST) (Academic Research Consortium definition). Analysis was by intention to treat. RESULTS At 5 years, the BES was noninferior to SES for the primary endpoint (186 [22.3%] vs. 216 [26.1%], rate ratio [RR]: 0.83 [95% confidence interval (CI): 0.68 to 1.02], p for noninferiority <0.0001, p for superiority = 0.069). The BES was associated with a significant reduction in the more comprehensive patient-orientated composite endpoint of all-cause death, any MI, and all-cause revascularization (297 [35.1%] vs. 339 [40.4%], RR: 0.84 [95% CI: 0.71 to 0.98], p for superiority = 0.023). A significant reduction in very late definite ST from 1 to 5 years was evident with the BES (n = 5 [0.7%] vs. n = 19 [2.5%], RR: 0.26 [95% CI: 0.10 to 0.68], p = 0.003), corresponding to a significant reduction in ST-associated clinical events (primary endpoint) over the same time period (n = 3 of 749 vs. n = 14 of 738, RR: 0.20 [95% CI: 0.06 to 0.71], p = 0.005). CONCLUSIONS The safety benefit of the biodegradable polymer BES, compared with the durable polymer SES, was related to a significant reduction in very late ST (>1 year) and associated composite clinical outcomes. (Limus Eluted From A Durable Versus ERodable Stent Coating [LEADERS] trial; NCT00389220).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among the possible consequences of agency problems between owners and managers is a tendency by managers to make investment decisions for their firms that are deliberately aimed at reducing firm risk, as a means to control managers' personal wealth risk. The literature has suggested that such behavior may occur to the detriment of shareholder wealth, and that mrgers may be a particular class of investment decisions for which the behavior would be observable. We test these hypotheses empirically, but find no evidence from our merger sample that risk reduction for the aqquiring firm is the typical outcome nor that, when it occurs, it is differentially costly for shareholders.