998 resultados para Cardiac Imaging


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Purpose Early prediction of motor outcome is of interest in stroke management. We aimed to determine whether lesion location at DTT is predictive of motor outcome after acute stroke and whether this information improves the predictive accuracy of the clinical scores. Methods We evaluated 60 consecutive patients within 12 hours of MCA stroke onset. We used DTT to evaluate CST involvement in the MC and PMC, CS, CR, and PLIC and in combinations of these regions at admission, at day 3, and at day 30. Severity of limb weakness was assessed using the m-NIHSS (5a, 5b, 6a, 6b). We calculated volumes of infarct and FA values in the CST of the pons. Results Acute damage to the PLIC was the best predictor associated with poor motor outcome, axonal damage, and clinical severity at admission (P&.001). There was no significant correlation between acute infarct volume and motor outcome at day 90 (P=.176, r=0.485). The sensitivity, specificity, and positive and negative predictive values of acute CST involvement at the level of the PLIC for 4 motor outcome at day 90 were 73.7%, 100%, 100%, and 89.1%, respectively. In the acute stage, DTT predicted motor outcome at day 90 better than the clinical scores (R2=75.50, F=80.09, P&.001). Conclusions In the acute setting, DTT is promising for stroke mapping to predict motor outcome. Acute CST damage at the level of the PLIC is a significant predictor of unfavorable motor outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Es presenta un estudi retrospectiu descrivint les característiques radiològiques en una sèrie de nou casos de tumor fibrós solitari que affecta partes toves. Aquests resultats es comparen amb els resultats d’anatomia patològica i amb l’evolució clínica dels pacients

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated whether neuron-specific enolase (NSE) in serum or cerebrospinal fluid (CSF) reflects subtle or manifest brain injury in children undergoing cardiac surgery using cardiopulmonary bypass (CPB). NSE was measured in serum (s-NSE) before, and up to, 102 h after surgery in 27 children undergoing cardiac surgery with CPB. In 11 children, CSF-NSE was also measured 48 or 66 h post-surgery. As erythrocytes contain NSE, hemoglobin concentration in the samples was determined spectrophotometrically at 550 nm (cut-off limit: absorbance 0.4 = 560 mg/l) in 14 children and in a further 13 children by spectroscopic multicomponent analysis (cut-off limit 5 micromol/l = 80 mg/l). One hundred and one of 214 post-operative serum samples (47%) had to be discarded because of hemolysis (18% spectrophotometrically at 550 nm and 88% with spectroscopic multicomponent analysis). On the first and second post-operative day, the median s-NSE values were significantly higher when compared with samples taken after 54 h or longer (P = 0.008 and P = 0.002). All CSF-NSE levels were within the normal range and below the s-NSE measured in the same patient. Although in our study elevated s-NSE seems to indicate brain injury in CPB-surgery, the low concentration of NSE in the post-operative CSF of 11 children puts the neuronal origin of s-NSE in question. NSE from other non-neuronal tissues probably contributes to the elevated s-NSE. Additionally, normal post-operative CSF-NSE values in two children with post-operative neurological sequelae might question the predictive value of CSF-NSE with regard to brain injury.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: A single bolus dose of etomidate decreases cortisol synthesis by inhibiting the 11-beta hydroxylase, a mitochondrial enzyme in the final step of cortisol synthesis. In our institution, all the patients undergoing cardiac surgery receive etomidate at anesthesia induction. The purpose of this study was to assess the incidence of adrenocortical dysfunction after a single dose of etomidate in selected patients undergoing major cardiac surgery and requiring high-dose norepinephrine postoperatively. STUDY DESIGN: Retrospective descriptive study in the surgical ICU of a university hospital. PATIENTS AND METHODS: Sixty-three patients presented acute circulatory failure requiring norepinephrine (>0,2 microg/kg/min) during the 48 hours following cardiac surgery. Absolute adrenal insufficiency was defined as a basal cortisol below 414 nmo/l (15 microg/dl) and relative adrenal insufficiency as a basal plasma cortisol between 414 nmo/l (15 microg/dl) and 938 nmo/l (34 microg/dl) with an incremental response after 250 microg of synthetic corticotropin (measured at 60 minutes) below 250 nmol/l (9 microg/dl). RESULTS: Fourteen patients (22%) had normal corticotropin test results, 10 (16%) had absolute and 39 (62%) relative adrenal insufficiency. All patients received a low-dose steroid substitution after the corticotropin test. Substituted patients had similar clinical outcomes compared to patients with normal adrenal function. CONCLUSION: A high incidence of relative adrenal failure was observed in selected cardiac surgery patients with acute postoperative circulatory failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electromagnetic radiation at a terahertz frequencies (from 0.1 THz to 10 THz) is situated in the frequency band comprised between the optical band and the radio band. The interest of the scientific community in this frequency band has grown up due to its large capabilities to develop innovative imaging systems. The terahertz waves are able to generate extremely short pulses that achieve good spatial resolution, good penetration capabilities and allow to identify microscopic structures using spectral analysis. The work carried out during the period of the grant has been based on the developement of system working at the aforementioned frequency band. The main system is based on a total power radiometer working at 0.1 THz to perform security imaging. Moreover, the development of this system has been useful to gain knowledge in the behavior of the component systems at this frequency band. Moreover, a vectorial network analyzer has been used to characterize materials and perform active raster imaging. A materials measurement system has been designed and used to measure material properties as permittivity, losses and water concentration. Finally, the design of a terahertz time-domain spectrometer (THz-TDS) system has been started. This system will allow to perform tomographic measurement with very high penetration resolutions while allowing the spectral characterization of the sample material. The application range of this kind of system is very wide: from the identification of cancerous tissues of a skin to the characterization of the thickness of a painted surface of a car.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The majority of convulsions are due to an epileptic seizure or a convulsive syncope. The incidence of out-of-hospital cardiac arrest (OH-CA) presenting as a convulsion is unknown. Objective: This study aimed to measure the incidence of adult nontraumatic OH-CA presenting as a convulsion, a rate that has not been published so far, to the best of our knowledge. Methods: We prospectively collected all incoming calls with an out-of-hospital nontraumatic seizure as the chief complaint in patients >18 years old during a 24-month period. Among these calls, we collected cases identified as OH-CA by paramedics. Results: During the 24-month period, the emergency medical services (EMS) dispatch center received 561 calls for an out-of-hospital nontraumatic convulsion in an adult. Twelve cases were ultimately classified as CA. In this group, one bystander spontaneously reported that the patient was known for epilepsy. The incidence of OH-CA presenting as convulsions was therefore 2.1% of all calls for convulsion. Over the same period, the EMS dispatch center received 1,035 calls related to an adult nontraumatic OH-CA. Therefore, the rate of OH-CA presenting as a convulsion represented 1.2% of all adult nontraumatic OH-CA. Conclusion:L Only 12 cases out of the 531 calls for nontraumatic adult convulsions were confirmed OHCA (2.1%). Nevertheless, this unusual presentation of OH-CA must be recognized by dispatchers, even when a patient is reported by bystander as a known epileptic. Dispatchers should keep bystanders on the line or call them back before paramedics' arrival, and have them confirm the progressive return of a normal pat- tern of breathing and state of consciousness; if not, they should encourage the bystander to initiate CPR when necessary. An intervention should be implemented to improve the detection by dispatchers of OH-CA presenting as convulsion by the development of a specific interview and directed observation. For dispatchers, a past medical history of epilepsy should not be regarded as sufficient information to rule out OH-CA. It is mandatory that known epileptic patients should be monitored in the same way as nonepileptic patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Cognitive impairment affects 40-65% of multiple sclerosis (MS) patients, often since early stages of the disease (relapsing remitting MS, RRMS). Frequently affected functions are memory, attention or executive abilities but the most sensitive measure of cognitive deficits in early MS is the information processing speed (Amato, 2008). MRI has been extensively exploited to investigate the substrate of cognitive dysfunction in MS but the underlying physiopathological mechanisms remain unclear. White matter lesion load, whole-brain atrophy and cortical lesions' number play a role but correlations are in some cases modest (Rovaris, 2006; Calabrese, 2009). In this study, we aimed at characterizing and correlating the T1 relaxation times of cortical and sub-cortical lesions with cognitive deficits detected by neuropsychological tests in a group of very early RR MS patients. Methods: Ten female patients with very early RRMS (age: 31.6 ±4.7y; disease duration: 3.8 ±1.9y; EDSS disability score: 1.8 ±0.4) and 10 age- and gender-matched healthy volunteers (mean age: 31.2 ±5.8y) were included in the study. All participants underwent the following neuropsychological tests: Rao's Brief Repeatable Battery of Neuropsychological tests (BRB-N), Stockings of Cambridge, Trail Making Test (TMT, part A and B), Boston Naming Test, Hooper Visual Organization Test and copy of the Rey-Osterrieth Complex Figure. Within 2 weeks from neuropsychological assessment, participants underwent brain MRI at 3T (Magnetom Trio a Tim System, Siemens, Germany) using a 32-channel head coil. The imaging protocol included 3D sequences with 1x1x1.2 mm3 resolution and 256x256x160 matrix, except for axial 2D-FLAIR: -DIR (T2-weighted, suppressing both WM and CSF; Pouwels, 2006) -MPRAGE (T1-weighted; Mugler, 1991) -MP2RAGE (T1-weighted with T1 maps; Marques, 2010) -FLAIR SPACE (only for patient 4-10, T2-weighted; Mugler, 2001) -2D Axial FLAIR (0.9x0.9x2.5 mm3, 256x256x44 matrix). Lesions were identified by one experienced neurologist and radiologist using all contrasts, manually contoured and assigned to regional locations (cortical or sub-cortical). Lesion number, volume and T1 relaxation time were calculated for lesions in each contrast and in a merged mask representing the union of the lesions from all contrasts. T1 relaxation times of lesions were normalized with the mean T1 value in corresponding control regions of the healthy subjects. Statistical analysis was performed using GraphPad InStat software. Cognitive scores were compared between patients and controls with paired t-tests; p values ≤ 0.05 were considered significant. Spearmann correlation tests were performed between the cognitive tests, which differed significantly between patients and controls, and lesions' i) number ii) volume iii) T1 relaxation time iv) disease duration and v) years of study. Results: Cortical and sub-cortical lesions count, T1 values and volume are reported in Table 1 (A and B). All early RRMS patients showed cortical lesions (CLs) and the majority consisted of CLs type I (lesions with a cortical component extending to the sub-cortical tissue). The rest of cortical lesions were characterized as type II (intra-cortical lesions). No type III/IV lesions (large sub-pial lesions) were detected. RRMS patients were slightly less educated (13.5±2.5y vs. 16.3±1.8y of study, p=0.02) than the controls. Signs of cortical dysfunction (i.e. impaired learning, language, visuo-spatial skills or gnosis) were rare in all patients. However, patients showed on average lower scores on measures of visual attention and information processing speed (TMT-part A: p=0.01; TMT-part B: p=0.006; PASAT-included in the BRB-N: p=0.04). The T1 relaxation values of CLs type I negatively correlated with the TMT-part A score (r=0.78, p<0.01). The correlations of TMT-part B score and PASAT score with T1 relaxation time of lesions as well and the correlation between TMT-part A, TMT-part B and PASAT score with lesions' i) number ii) volume iii) disease duration and iv) years of study did not reach significance. In order to preclude possible influences from partial volume effects on the T1 values, the correlation between lesion volume and T1 value of CLs type I was calculated; no correlation was found, suggesting that partial volume effects did not affect the statistics. Conclusions: The present pilot study reports for the first time the presence and the T1 characteristics at 3 T of cortical lesions in very early RRMS (< 6 y disease duration). It also shows that CLS type I represents the most frequent cortical lesion type in this cohort of RRMS patients. In addition, it reveals a negative correlation between the attentional test TMT-part A and the T1 properties of cortical lesions type I. In other words, lower attention deficits are concomitant with longer T1-relaxation time in cortical lesions. In respect to this last finding, it could be speculated that long relaxation time correspond to a certain degree of tissue loss that is enough to stimulate compensatory mechanisms. This hypothesis is in line with previous fMRI studies showing functional compensatory mechanisms to help maintaining normal or sub-normal attention performances in RR MS patients (Penner, 2003).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this study was to compare a novel compressed sensing (CS)-based single-breath-hold multislice magnetic resonance cine technique with the standard multi-breath-hold technique for the assessment of left ventricular (LV) volumes and function. BACKGROUND: Cardiac magnetic resonance is generally accepted as the gold standard for LV volume and function assessment. LV function is 1 of the most important cardiac parameters for diagnosis and the monitoring of treatment effects. Recently, CS techniques have emerged as a means to accelerate data acquisition. METHODS: The prototype CS cine sequence acquires 3 long-axis and 4 short-axis cine loops in 1 single breath-hold (temporal/spatial resolution: 30 ms/1.5 × 1.5 mm(2); acceleration factor 11.0) to measure left ventricular ejection fraction (LVEFCS) as well as LV volumes and LV mass using LV model-based 4D software. For comparison, a conventional stack of multi-breath-hold cine images was acquired (temporal/spatial resolution 40 ms/1.2 × 1.6 mm(2)). As a reference for the left ventricular stroke volume (LVSV), aortic flow was measured by phase-contrast acquisition. RESULTS: In 94% of the 33 participants (12 volunteers: mean age 33 ± 7 years; 21 patients: mean age 63 ± 13 years with different LV pathologies), the image quality of the CS acquisitions was excellent. LVEFCS and LVEFstandard were similar (48.5 ± 15.9% vs. 49.8 ± 15.8%; p = 0.11; r = 0.96; slope 0.97; p < 0.00001). Agreement of LVSVCS with aortic flow was superior to that of LVSVstandard (overestimation vs. aortic flow: 5.6 ± 6.5 ml vs. 16.2 ± 11.7 ml, respectively; p = 0.012) with less variability (r = 0.91; p < 0.00001 for the CS technique vs. r = 0.71; p < 0.01 for the standard technique). The intraobserver and interobserver agreement for all CS parameters was good (slopes 0.93 to 1.06; r = 0.90 to 0.99). CONCLUSIONS: The results demonstrated the feasibility of applying the CS strategy to evaluate LV function and volumes with high accuracy in patients. The single-breath-hold CS strategy has the potential to replace the multi-breath-hold standard cardiac magnetic resonance technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Minister for Health and Children established the Task Force on Sudden Cardiac Death (SCD) in the Autumn of 2004, with the following terms of reference:1) Define SCD and describe its incidence and underlying causes in Ireland.2) Advise on the detection and assessment of those at high risk of SCD and their relatives.3) Advise on the systematic assessment of those engaged in sports and exercise for risk of SCD.4) Advise on maximizing access to basic life support (BLS) and automated external defibrillators (AEDs) and on:- appropriate levels of training in BLS and use of AEDs, and on the maintenance of that training- priority individuals and priority groups for such training- geographic areas and functional locations of greatest need- best practice models of first responder scheme and public access defibrillation, and- integration of such training services.5) Advise on the establishment and maintenance of surveillance systems, including a registry of SCD and information systems to monitor risk assessment, and training and equipment programmes.6) Advise and make recommendations on other priority issues relevant to SCD in Ireland.7) Outline a plan for implementation and advise on monitoring the implementation of recommendations made in the Task Force’s report. In undertaking its work the Task Force was mindful of national health policy, relevant national strategies and of the recently reformed structures for health service delivery in Ireland. Read the Report (PDF, 1.66mb)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: Dose reduction may compromise patients because of a decrease of image quality. Therefore, the amount of dose savings in new dose-reduction techniques needs to be thoroughly assessed. To avoid repeated studies in one patient, chest computed tomography (CT) scans with different dose levels were performed in corpses comparing model-based iterative reconstruction (MBIR) as a tool to enhance image quality with current standard full-dose imaging. MATERIALS AND METHODS: Twenty-five human cadavers were scanned (CT HD750) after contrast medium injection at different, decreasing dose levels D0-D5 and respectively reconstructed with MBIR. The data at full-dose level, D0, have been additionally reconstructed with standard adaptive statistical iterative reconstruction (ASIR), which represented the full-dose baseline reference (FDBR). Two radiologists independently compared image quality (IQ) in 3-mm multiplanar reformations for soft-tissue evaluation of D0-D5 to FDBR (-2, diagnostically inferior; -1, inferior; 0, equal; +1, superior; and +2, diagnostically superior). For statistical analysis, the intraclass correlation coefficient (ICC) and the Wilcoxon test were used. RESULTS: Mean CT dose index values (mGy) were as follows: D0/FDBR = 10.1 ± 1.7, D1 = 6.2 ± 2.8, D2 = 5.7 ± 2.7, D3 = 3.5 ± 1.9, D4 = 1.8 ± 1.0, and D5 = 0.9 ± 0.5. Mean IQ ratings were as follows: D0 = +1.8 ± 0.2, D1 = +1.5 ± 0.3, D2 = +1.1 ± 0.3, D3 = +0.7 ± 0.5, D4 = +0.1 ± 0.5, and D5 = -1.2 ± 0.5. All values demonstrated a significant difference to baseline (P < .05), except mean IQ for D4 (P = .61). ICC was 0.91. CONCLUSIONS: Compared to ASIR, MBIR allowed for a significant dose reduction of 82% without impairment of IQ. This resulted in a calculated mean effective dose below 1 mSv.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The cerebellum is a complex structure that can be affected by several congenital and acquired diseases leading to alteration of its function and neuronal circuits. Identifying the structural bases of cerebellar neuronal networks in humans in vivo may provide biomarkers for diagnosis and management of cerebellar diseases. OBJECTIVES: To define the anatomy of intrinsic and extrinsic cerebellar circuits using high-angular resolution diffusion spectrum imaging (DSI). METHODS: We acquired high-resolution structural MRI and DSI of the cerebellum in four healthy female subjects at 3T. DSI tractography based on a streamline algorithm was performed to identify the circuits connecting the cerebellar cortex with the deep cerebellar nuclei, selected brainstem nuclei, and the thalamus. RESULTS: Using in-vivo DSI in humans we were able to demonstrate the structure of the following cerebellar neuronal circuits: (1) connections of the inferior olivary nucleus with the cerebellar cortex, and with the deep cerebellar nuclei (2) connections between the cerebellar cortex and the deep cerebellar nuclei, (3) connections of the deep cerebellar nuclei conveyed in the superior (SCP), middle (MCP) and inferior (ICP) cerebellar peduncles, (4) complex intersections of fibers in the SCP, MCP and ICP, and (5) connections between the deep cerebellar nuclei and the red nucleus and the thalamus. CONCLUSION: For the first time, we show that DSI tractography in humans in vivo is capable of revealing the structural bases of complex cerebellar networks. DSI thus appears to be a promising imaging method for characterizing anatomical disruptions that occur in cerebellar diseases, and for monitoring response to therapeutic interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different interferometric techniques were developed last decade to obtain full field, quantitative, and absolute phase imaging, such as phase-shifting, Fourier phase microscopy, Hilbert phase microscopy or digital holographic microscopy (DHM). Although, these techniques are very similar, DHM combines several advantages. In contrast, to phase shifting, DHM is indeed capable of single-shot hologram recording allowing a real-time absolute phase imaging. On the other hand, unlike to Fourier phase or Hilbert phase microscopy, DHM does not require to record in focus images of the specimen on the digital detector (CCD or CMOS camera), because a numerical focalization adjustment can be performed by a numerical wavefront propagation. Consequently, the depth of view of high NA microscope objectives is numerically extended. For example, two different biological cells, floating at different depths in a liquid, can be focalized numerically from the same digital hologram. Moreover, the numerical propagation associated to digital optics and automatic fitting procedures, permits vibrations insensitive full- field phase imaging and the complete compensation for a priori any image distortion or/and phase aberrations introduced for example by imperfections of holders or perfusion chamber. Examples of real-time full-field phase images of biological cells have been demonstrated. ©2008 COPYRIGHT SPIE

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of in situ techniques to detect DNA and RNA sequences has proven to be an invaluable technique with paraffin-embedded tissue. Advances in non-radioactive detection systems have further made these procedures shorter and safer. We report the detection of Trypanosoma cruzi, the causative agent of Chagas disease, via indirect and direct in situ polymerace chain reaction within paraffin-embedded murine cardiac tissue sections. The presence of three T. cruzi specific DNA sequences were evaluated: a 122 base pair (bp) sequence localized within the minicircle network, a 188 bp satellite nuclear repetitive sequence and a 177 bp sequence that codes for a flagellar protein. In situ hybridization alone was sensitive enough to detect all three T. cruzi specific DNA sequences.