1000 resultados para Canal de Lachine


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hypoglossal nerve (HN) is responsible for the intrinsic and extrinsic muscles of the tongue. Knowledge of this is extremely important because this nerve is responsible for tongue movement. HN paralysis can be associated to the disease itself in various zones in which the NH travels, mainly the hypoglossal canal (HC). Variations in shape of the hypoglossal canal have been pointed to as the cause of HN paralysis in several studies. Four hundred dried intact human skulls without sex or race identification, belonging to the Discipline of Anatomy of ICTSJC – UNESP were studied. Each canal was classified into types: type I (without division in the HC), type II (HC with low bone spike), type III (HC more than two projections bone), type IV (presence of complete bony bridge without dividing HC into two distinct canals) and type V (presence of bone bridge by dividing into two HC canals). HC was found in 100% of skulls studied in both side. Regarding types, we found 538 (67.25%) hypoglossal canal of type I (34%, right side and 33.25%, left side), 108 (13.5%) of type II (7.38%, right side, and 6.13%, left side), 60 (7.5%) hypoglossal canal of type III (3.5%, right side and 4.0%, left side) 84 (10.5%) of type IV (4.75%, right side and 5.75%, left side) and 5 (0.63%) of the type V (0.13%, right side and 0.5%, left side). We found 5 (0,63%) different HC and classified ourselves in type VI, VII and VIII. The average angle was 51,3º on right side and 50,25º on left side. Detailed knowledge of the anatomy of the CH supports professionals in interventions of bloody skull base and also in giving the correct diagnosis of the probable causes of paralysis of the hypoglossal nerve

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the increase of the cervical area and dentin thickness in mesial and distal walls of the mesial canals from mandibular molars after the use of LA Axxess (LA), CP Drill (CP) and Gates-Glidden (GG) rotary instruments. Material and Methods: Sixty root canals from thirty mandibular first molar were sectioned 3 mm below the cement-enamel junction, divided in 3 groups (n = 20 root canals, each) according to rotary instrument used, and the cervical images were captured before and after pre-enlargement instrumentation. The increase of the instrumented cervical area (mm2) and the dentin removal thickness (mm), at mesial and distal walls were calculated using Image tools software, by comparison of images. Data were analyzed by ANOVA and Tukey tests (p=0.05). Results: All rotary instruments promoted thickness reduction in dentin walls. In mesial wall, all rotary instruments promoted similar thickness reduction of dentinal wall and did not differ from each other (p>0.05). In distal wall, LA Axxess instrument promoted higher dentin thickness reduction than other groups (p<0.05). The three rotary instruments promoted different increase at the instrumented cervical area (p<0.05), LA promoted the highest increase area and GG and CP presented similar results. Conclusion: LA 20/0.06 promoted the highest thickness reduction in distal wall and increase of cervical area of root canal. On the other hand, CP was the safest instrument, with lower dentin removal of distal wall and similar increased area to GG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The irrigation of root canals aims to their cleaning and disinfection, improving endodontic treatment success. Objective: To investigate the influence of the diameter and type of irrigation needle and the root canal enlargement on the mechanical efficacy of endodontic irrigation. Material and methods: Twelve human single-rooted mandibular incisors were used. During some instrumentation stages (enlargement by #20, #30, and #40 K file), root canals were filled with radiographic contrast solution mixed to propyleneglycol and zinc oxide. Needles with different diameters and designs were employed: G1 – 23G and lateral opening; G2 – 22G and apical opening; G3 – 30G and lateral opening; G4 – 30G and apical opening. The needles were inserted up to resistance, with 1 mm step-back to avoid root canal obliteration. The irrigation was performed with 2 mL of distilled water. Before and after irrigation/aspiration, teeth were radiographed at bucco-lingual and mesiodistal direction, using a digital radiographic system. Then, root canal areas, before (filled by contrast solution) and after irrigation (remnant of contrast solution), were submitted to image subtraction with Adobe Photoshop CS4 software. Subsequently, the areas were measured by Image Tool 3.0 software, allowing the obtaining of the cleaning percentage for each modality. Data were analysed by using Anova and Tukey’s test. The level of significance was set at P < 0.05. Results: For all root canal enlargements, 30G needles (G3 e G4) presented a better cleaning efficacy. In all groups, higher cleaning efficacy percentage was observed at #30 and #40 K file enlargement. Conclusion: Regardless their design, thinner needles were more effective; a better cleaning efficacy occurred in more enlarged root canals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: This study investigated the flowability, setting time, pH, calcium release and bond strength of a MTA-based cement (MTA Fillapex®) compared to AH Plus and Sealapex. Materials and methods: For the flowability test, the ISO 6876:2001 specification was utilized and for the setting time test, the ASTM C266-03 specification was utilized. For the pH and calcium release measurements, 10 samples were prepared for each group and analyzed for several different periods. For the push-out test, dentin disks were distributed into three groups, according to the cement utilized and into three subgroups, according to the root third (n = 10). After obturation, the specimens underwent push-out testing. The data were compared statistically using a significance level of 5%. Results: The flowability of all materials was found to be similar (p > 0.05). The setting times were different among the groups tested (MTA Fillapex < Sealapex < AH Plus) (p < 0.05). At days 7 and 28, the MTA Fillapex presented the higher pH values (p < 0.05). At 24 hours and at 14 days, the calcium release of the MTA Fillapex was similar to that of Sealapex (p > 0.05). AH Plus presented the lowest pH and calcium release values (p < 0.05). In all root thirds, the adhesion to the dentin of the MTA Fillapex and Sealapex were significantly lower than that of AH Plus (p < 0.05). Conclusion: MTA Fillapex and Sealapex presented several similar properties and both were found to be different than AH Plus. Clinical significance: This study evaluated the physicochemical and mechanical properties of new MTA-based root canal cement, in order to use this scaler in root canal fillings. MTA Fillapex showed satisfactory properties for clinical use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate the effectiveness of ProTaper universal retreatment system in the removal of root canal filling material with thermomechanical compaction, in comparison to manualmechanical technique, associated with orange oil or eucalyptol. Materials and methods: Forty extracted lower incisors were filled with thermomechanical compaction technique. After 3 years, the root canal filling was removed by: G1 - manualmechanical technique with orange oil; G2 - manual-mechanical technique with eucalyptol; G3 - ProTaper universal retreatment system with orange oil and G4 - ProTaper universal retreatment system with eucalyptol. In sequence, all root canals were instrumented to F5 instrument. The teeth were longitudinally grooved, images of buccal half were obtained in stereomicroscope and covered area by root canal filling material was measured using image tool software, in cervical, middle and apical radicular thirds. The results were subjected ANOVA and Tukey test (p = 0.05). Results: In all thirds, the manual-mechanical technique showed lower presence of root canal filling material on root canal dentin in comparison to ProTaper retreatment universal system, regardless of organic solvent used (p < 0.05). There is no difference between organic solvents in removal root canal filling material (p > 0.05). Conclusion: The ProTaper universal retreatment system showed lower effectiveness in removal root canal filling material than manual-mechanical technique, regardless of organic solvents (orange oil or eucalyptol oil) used. Clinical significance: Recently rotary instruments have been proposed to removal of root canal filling material. However, there are no studies evaluating its effectiveness in removal root canal filling material in association with orange oil or eucalyptol oil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: This clinical report presents a new method for retrieving separated instruments from the root canal with minimally invasive procedures. Background: The presence of separated instrument in root canal may interfere in the endodontic treatment prognosis. There are several recommended methods to retrieve separated instruments, but some are difficult in clinically practice. Case report: This study describes two cases of separated instrument removal from the root canal using a stainless-steel prepared needle associated with a K-file. Case 1 presented a fractured gutta-percha condenser within the mandibular second premolar, it was separated during incorrect intracanal medication calcium hydroxide placement. Case 2 had a fractured sewing needle within the upper central incisor that the patient used to remove food debris from the root canal. After cervical preparation, the fractured instruments were fitted inside a prepared needle and then an endodontic instrument (#25 K-file) was adapted with clockwise turning motion between the needle inner wall and the fragment. Conclusion: The endodontic or atypical nonendodontic separated instrument may be easily pull on of the root canal using a single and low cost device. Clinical significance: The methods for retrieving separated instruments from root canal are difficult and destructive procedures. The present case describes a simple method to solve this problem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim The aim of the present study was to evaluate the effect of three different formulations of sodium hypochlorite on the microhardness of root canal dentin in cervical and apical segments. Methods Twenty-four extracted human teeth had their roots sectioned along their long axes in a buccolingual direction. One half of each root was selected, and transversely sectioned resulting in two segments, cervical and apical, with similar lengths. The specimens were divided into three groups (n = 16), according to the sodium hypochlorite formulation used: (a) group 1, 2.5% sodium hypochlorite; (b) group 2, Chlor-XTRA; and (c) group 3, 5.5% sodium hypochlorite gel. These groups were subdivided in two subgroups (n = 8): cervical and apical root segments. Before testing the substances, dentin microhardness was measured on each section, 100 μm from the root canal with a Knoop tester. After 15 min of application, a new measurement was performed on each segment. Data were collected and registered for statistical treatment. Results In both segments, the substances reduced dentin microhardness. No differences were observed between the groups, independent of the analyzed segment (P > 0.05). Conclusions All substances reduced dentin microhardness. Chlor-XTRA and 5.5% sodium hypochlorite gel promoted a reduction similar to the 2.5% sodium hypochlorite solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)