996 resultados para CT value
Resumo:
Positron emission computed tomography (PET) is a functional, noninvasive method for imaging regional metabolic processes that is nowadays most often combined to morphological imaging with computed tomography (CT). Its use is based on the well-founded assumption that metabolic changes occur earlier in tumors than morphologic changes, adding another dimension to imaging. This article will review the established and investigational indications and radiopharmaceuticals for PET/CT imaging for prostate cancer, bladder cancer and testicular cancer, before presenting upcoming applications in radiation therapy.
Resumo:
Abstract
Resumo:
Do our brains implicitly track the energetic content of the foods we see? Using electrical neuroimaging of visual evoked potentials (VEPs) we show that the human brain can rapidly discern food's energetic value, vis à vis its fat content, solely from its visual presentation. Responses to images of high-energy and low-energy food differed over two distinct time periods. The first period, starting at approximately 165 ms post-stimulus onset, followed from modulations in VEP topography and by extension in the configuration of the underlying brain network. Statistical comparison of source estimations identified differences distributed across a wide network including both posterior occipital regions and temporo-parietal cortices typically associated with object processing, and also inferior frontal cortices typically associated with decision-making. During a successive processing stage (starting at approximately 300 ms), responses differed both topographically and in terms of strength, with source estimations differing predominantly within prefrontal cortical regions implicated in reward assessment and decision-making. These effects occur orthogonally to the task that is actually being performed and suggest that reward properties such as a food's energetic content are treated rapidly and in parallel by a distributed network of brain regions involved in object categorization, reward assessment, and decision-making.
Resumo:
Companies are under IAS 40 required to report fair values of investment properties on the balance sheet or to disclose them in the notes. The standard requires also that companies have to disclose the methods and significant assumptions applied in determining fair values of investment properties. However, IAS 40 does not include any illustrative examples or other guidance on how to apply the disclosure requirements. We use a sample with publicly traded companies from the real estate sector in the EU. We find that a majority of the companies use income based methods for the measurement of fair values but there are considerable cross-country variations in the level of disclosures about the assumptions used in determining fair values. More specifically, we find that Scandinavian and German origin companies disclose more than French and English origin companies. We also test whether disclosure quality is associated with enforcement quality measured with the “Rule of Law” index according to Kaufmann et al. (2010), and associated with a secrecy- versus transparency-measure based on Gray (1988). We find a positive association between disclosure and earnings quality and a negative association with secrecy.
Resumo:
Abstract
Resumo:
Purpose: 1. To review Ct features suggestive of saprophytic aspergillosis (aspergilloma) and to correlate them with the final pathological results. 2. To illustrate the wide range of differential diagnosis. Methods and materials: The electronic database of our department from 1995 to 2007 revealed CT reports of 48 patients that had been considered very suggestive of aspergilloma. Two radiologists with 6 and 12 years experience in thoracic radiology jointly reviewed the corresponding CT features including ancillary findings and the underlying lung diseases and correlated them with the final pathological diagnosis. Results: Forty patients could be included in the study (12 women, mean age 52), while in 8 patients there was no adequate clinical follow-up. In 17 patients the diagnosis "mycetoma" due to aspergillus fumigatus infection was confirmed, either by surgery, biopsy or bronchoscopy. In 23 patients, differential diagnoses were found, such as cavitating bronchial carcinoma (n = 7), bacterial abscess (n = 3), typical (n = 2) and atypical (n = 2) tuberculosis, as well as inflammatory changes due to mucoviscidosis (n = 1), Wegener's disease (n = 1) or chronic obstructive pulmonary disease (n = 3). Fibromyxoide hamartoma, lung infarction and bronchomucocele were responsible for the typical CT feature in one patient each. Conclusion: 1. The typical CT feature suggesting mycetoma is softtissue proliferation within a pre-existing wall-thickened lung cavity, oten even considered "pathognomonic". However, this diagnosis was finally confirmed by surgery or laboratory findings in less than 50% of patients only. 2. Since differential diagnoses are very large, not only including cavitating lung cancer and tuberculosis, the individual underlying lung disease needs strongly being taken into account often giving the best clue for the correct diagnosis.
Resumo:
Messages à retenir: Le scanner peut aider au diagnostic et la caractérisation des valvulopathies et des lésions associées (aorte, coronaires). Le scanner est un examen incontournable pour l'évaluation pré-thérapeutique des procédures TAVI (transfémorale ou transapicale). Le scanner peut être utile pour caractériser les insuffisances aortiques. Grâce aux développements récents dans les thérapies peu invasives et au progrès du CT, le rôle du radiologue est redevenu central dans la prise en charge de certaines valvulopathies aortiques. Résumé: Les valvulopathies aortiques sont des maladies fréquentes. Leur exploration repose largement sur l'échocardiographie et sur l'IRM. Les progrès technologiques en scanner cardiaque ont permis à ce dernier d'explorer la valve aortique et ses pathologies. Ce cours est principalement consacré aux méthodes d'acquisition et de traitement des images dédiées à l'exploration de la valve aortique (plan de coupes, planimétrie, scores...). Une attention particulière est réservée aux considérations anatomiques spécifiques à celle-ci (variantes anatomiques). Les indications du scanner cardiaque dans les valvulopathies seront résumées (sténoses, insuffisances, pathologie tumorale et pathologies inflammatoires). Dans la sténose de la valve, outre ses performances diagnostiques, le scanner plus ou moins couplé à l'exploration des vaisseaux périphériques, est devenu une méthode intournable dans le bilan pré-thérapeutique. La connaissance des paramètres à évaluer (taille de l'anneau, position des coronaires, orientation du plan de la valve...) et la standardisation des mesures sont un élément clé pour une prise en charge optimale. Dans les insuffisances aortiques, les méthodes de quantification (planimétrie) peuvent être utilisées pour les caractériser avec des performances comparables à celles obtenues par d'autres techniques.
Resumo:
The present study investigates the predictive value of the early appearance of simultaneous pointing-speech combinations. An experimental task was used to obtain a communicative productive sample from nineteen children at 1;0 and 1;3. Infant’s communicative productions, in combination with gaze joint engagement patterns, were analyzed in relation to different social conditions. The results show a significant effect of age and social condition on infants’ communicative productions. Gesture-speech combinations seem to work as a strong communicative resource to attract the adult’s attention in social demanding communicative contexts. Gaze joint engagement was used in combination with simultaneous pointing-speech combinations to attract adults’ attention during social demanding conditions. Finally, the use of simultaneous pointing-speech combinations at 1;0 in demanding conditions predicted greater expressive vocabulary acquisition at 1;3 and 1;6. These results indicate that the use of gesture-speech combinations may be considered a significant step towards the early integration of language components.
Resumo:
Background: Visual analog scales (VAS) are used to assess readiness to changeconstructs, which are often considered critical for change.Objective: We studied whether 3 constructs -readiness to change, importance of changing and confidence inability to change- predict risk status 6 months later in 20 year-old men with either orboth of two behaviors: risky drinking and smoking. Methods: 577 participants in abrief intervention randomized trial were assessed at baseline and 6 months later onalcohol and tobacco consumption and with three 1-10 VAS (readiness, importance,confidence) for each behavior. For each behavior, we used one regression model foreach constructs. Models controlled for receipt of a brief intervention and used thelowest level (1-4) in each construct as the reference group (vs medium (5-7) and high(8-10) levels).Results: Among the 475 risky drinkers, mean (SD) readiness, importance and confidence to change drinking were 4.0 (3.1), 2.8 (2.2) and 7.2 (3.0).Readiness was not associated with being alcohol-risk free 6 months later (OR 1.3[0.7; 2.2] and 1.4 [0.8; 2.6] for medium and high readiness). High importance andhigh confidence were associated with being risk free (OR 0.9 [0.5; 1.8] and 2.9 [1.2;7.5] for medium and high importance; 2.1 [1.0;4.8] and 2.8 [1.5;5.6] for medium andhigh confidence). Among the 320 smokers, mean readiness, importance andconfidence to change smoking were 4.6 (2.6), 5.3 (2.6) and 5.9 (2.6). Neitherreadiness nor importance were associated with being smoking free (OR 2.1 [0.9; 4.7]and 2.1 [0.8; 5.8] for medium and high readiness; 1.4 [0.6; 3.4] and 2.1 [0.8; 5.4] formedium and high importance). High confidence was associated with being smokingfree (OR 2.2 [0.8;6.6] and 3.4 [1.2;9.8] for medium and high confidence).Conclusions: For drinking and smoking, high confidence in ability to change wasassociated -with similar magnitude- with a favorable outcome. This points to thevalue of confidence as an important predictor of successful change.
Resumo:
The finding that tissue δ15N values increase with protein catabolism has led researchers to apply this value to gauge nutritive condition in vertebrates. However, its application to marine mammals has in most occasions failed. We investigated the relationship between δ15N values and the fattening/fasting cycle in a model species, the fin whale, a migratory capital breeder that experiences severe seasonal variation in body condition. We analyzed two tissues providing complementary insights: one with isotopic turnover (muscle) and one that keeps a permanent record of variations in isotopic values (baleen plates). In both tissues δ15N values increased with intensive feeding but decreased with fasting, thus contradicting the pattern previously anticipated. The apparent inconsistency during fasting is explained by the fact that a) individuals migrate between different isotopic isoscapes, b) starvation may not trigger significant negative nitrogen balance, and c) excretion drops and elimination of 15N-depleted urine is minimized. Conversely, when intensive feeding is resumed in the northern grounds, protein anabolism and excretion start again, triggering 15N enrichment. It can be concluded that in whales and other mammals that accrue massive depots of lipids as energetic reserves and which have limited access to drinking water, the δ15N value is not affected by fasting and therefore cannot be used as an indicatior of nutritive condition.
Resumo:
PURPOSE: To assess the technical feasibility of multi-detector row computed tomographic (CT) angiography in the assessment of peripheral arterial bypass grafts and to evaluate its accuracy and reliability in the detection of graft-related complications, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. MATERIALS AND METHODS: Four-channel multi-detector row CT angiography was performed in 65 consecutive patients with 85 peripheral arterial bypass grafts. Each bypass graft was divided into three segments (proximal anastomosis, course of the graft body, and distal anastomosis), resulting in 255 segments. Two readers evaluated all CT angiograms with regard to image quality and the presence of bypass graft-related abnormalities, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. The results were compared with McNemar test with Bonferroni correction. CT attenuation values were recorded at five different locations from the inflow artery to the outflow artery of the bypass graft. These findings were compared with the findings at duplex ultrasonography (US) in 65 patients and the findings at conventional digital subtraction angiography (DSA) in 27. RESULTS: Image quality was rated as good or excellent in 250 (98%) and in 252 (99%) of 255 bypass segments, respectively. There was excellent agreement both between readers and between CT angiography and duplex US in the detection of graft stenosis, aneurysmal changes, and arteriovenous fistulas (kappa = 0.86-0.99). CT angiography and duplex US were compared with conventional DSA, and there was no statistically significant difference (P >.25) in sensitivity or specificity between CT angiography and duplex US for both readers for detection of hemodynamically significant bypass stenosis or occlusion, aneurysmal changes, or arteriovenous fistulas. Mean CT attenuation values ranged from 232 HU in the inflow artery to 281 HU in the outflow artery of the bypass graft. CONCLUSION: Multi-detector row CT angiography may be an accurate and reliable technique after duplex US in the assessment of peripheral arterial bypass grafts and detection of graft-related complications, including stenosis, aneurysmal changes, and arteriovenous fistulas.