959 resultados para CNG tank
Resumo:
This study aimed to evaluate the use of a mixer to determine the rheological properties of fluids. The mixer is comprised of an agitation tank and an anchor type impeller. The tests were performed with honey and fruit juices (orange, guava and peach). The rheological characterization was performed using data from the torque and rotation speed required for the operation of fluid agitation. Tests were also made with a concentric cylinder rotational viscometer with the samples being subjected to various shear rates. The rheological parameters were obtained from the flow curves fitted to the power law model. Analyses of results showed that the mixer can be used, within its limitations, to determine rheological properties.
Resumo:
Currently has few studies today concerning the behavior of the ethyl alcohol hydrated combustible in the geological environment, results of eventual spill or leaks in a wide transport chain and distribution. This work discusses the results of an experiment in laboratorial scale, that involves the monitoring of alterations in physical properties a simulate leak of alcohol in a tank with sand saturated in water, during 4920 hours. Are applied electrical resistivity, induced polarization and spontaneous potential geophysical methods. The electric resistivity is clearly correlating to the ethanol degradation pattern. The chargeability demonstrated sensibility to this pattern, while the natural electric potential revealed direct association with the oscillations of groundwater level. The variability of the physical parameters monitoring probable control for ethanol degradation process in environment study.
Resumo:
The main article aim was to investigate the collecting system of a dissolved air flotation (DAF) unit in pilot scale. Referring to the collecting system position, two options were analyzed: (i) top manifold and (ii) bottom manifold, pipes or plates. Qualitative and quantitative essays were performed, as image and stimulusresponse tests, respectively. The results of the essays standardized were adjusted by N-continuous stirred tank reactors in series and theoretical models of dispersion (low and high). The bottom manifold (plates with orifices) was more appropriate. The results pointed out that the N-continuous stirred tank reactors in series model was more adequate to describe the hydrodynamic behavior of the DAF unit.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Milk that is adequate for consumption must be of hygienic quality, nutritional value, and should maintain its organoleptic properties. Isolation of fecal and/or total coliforms from bovine milk is considered an indicator of hygiene and good management practices, and can be used as a quality indicator. This study aimed to isolate, identify, and assess the resistance profile of coliforms isolated from collective bulk tanks and individual milk tanks. A total of 89 milk samples were collected from collective bulk tanks and, from these, 21 Klebsiella spp., one E. coli, and 29 Enterobacter spp. were isolated, whereas 102 milk samples from individual tanks showed isolation of one Klebsiella spp. and seven Enterobacter spp. In collective bulk tanks, at least 47% of Klebsiella spp. and Enterobacter spp. were resistant to cephalexin and 30% to ampicillin. From these, at least 24% showed multidrug resistance. Among the microorganisms isolated from the individual tanks, 85% or more were resistant to ampicillin. The ESBL phenotype and the blaTEM gene were detected in strains of Klebsiella spp. isolated from both tanks. It was concluded that contamination of milk with resistant total coliforms, and especially the storage of raw milk from several small producers in the collective bulk tank increase the risk of contamination.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
In this paper are discussed the main project stages of an atmospheric storage tank with floating roof. It emphasizes the calculations of the bottom, the shell and the floating roof, discussing its stages and conditions, based on the technical standards of the project. The storage tanks are static equipment working under low pressure and has an essential importance for the operation of a process plant. This paper has the purpose of obtaining the dimensions and materials of each component of the tank through the calculations and prove them with results obtained by numerical simulation by finite elements with the help of Autodesk Inventor software, consolidating the project
Resumo:
The desire of Nebraska people to continue the improvement of living conditions and to secure more healthful foods has been responsible for many changes in methods of caring for milk. One of the important factors in keeping milk sweet and of good quality is the process of cooling and keeping it cool until used. Three of these processes are as follows: placing containers of warm milk in any quantity of still water or still air at temperatures ranging from freezing to within a few degrees of the temperature of the milk, placing the containers in such positions that air or water are circulated around them, and causing the milk to flow in such manner that a thin film comes in contact with a surface which is cooled by air or liquids varying in temperature from 10 degrees Fahrenheit to a few degrees below that of the milk. After some of the heat has been removed the milk is stored under conditions very similar to those found in cooling processes. This 1932 research bulletin discusses why milk is cooled, why milk sours, how bacteria grows, and the many ways that milk can be cooled.
Resumo:
When the well "goes dry" or when the windmill or pump breaks down, every one in the household immediately appreciates the value fo plenty of water. In other words, "You never miss the water until the well runs dry." Fortunately, in most sections of this state, plenty of pure water may be obtained by sinking wells of moderate depth, yet surprisingly few farm homes are supplied with running water in the kitchen even though the barn yards are equipped with hydrants and tanks. It is the purpose of this bulletin to present a number of water supply and sewage disposal systems which have been used in Nebraska and surrounding states and which add greatly to the comfort and convenience of the farm home.
Resumo:
In this paper are discussed the main project stages of an atmospheric storage tank with floating roof. It emphasizes the calculations of the bottom, the shell and the floating roof, discussing its stages and conditions, based on the technical standards of the project. The storage tanks are static equipment working under low pressure and has an essential importance for the operation of a process plant. This paper has the purpose of obtaining the dimensions and materials of each component of the tank through the calculations and prove them with results obtained by numerical simulation by finite elements with the help of Autodesk Inventor software, consolidating the project
Resumo:
The retaking of the ethanol program in the year 2003 as a fuel for light road transportation in Brazil through the introduction of flex fuel vehicles fleet was a good strategy to overcome the difficulties of the ethanol production sector and did work to increase its market share relative to gasoline. This process, however, may cause a future disequilibrium on the food production and on the refining oil derivates structure. In order to analyze the substitution process resultant of the competition between two opponents fighting for the same market, in this case the gasoline/ethanol substitution process, a method derived from the biomathematics based on the non-linear differential equations (NLDE) system is utilized. A brief description of the method is presented. Numerical adherence of the method to explain several substitution phenomena that occurred in the past is presented in the previous author`s paper, in which the urban gas pipeline system substitution of bottled LPG in the dwelling sector and the substitution of the urban diesel transportation fleet by compressed natural gas (CNG) buses is presented. The proposed method is particularly suitable for prospective analysis and scenarios assessment. (c) 2008 Elsevier Ltd. All rights reserved.