979 resultados para Bilinear Predictive Control
Resumo:
The aim of this contribution is to extend the techniques of composite materials design to non-linear material behaviour and apply it for design of new materials for passive vibration control. As a first step a computational tool allowing determination of macroscopic optimized one-dimensional isolator behaviour was developed. Voigt, Maxwell, standard and more complex material models can be implemented. Objective function considers minimization of the initial reaction and/or displacement peak as well as minimization of the steady-state amplitude of reaction and/or displacement. The complex stiffness approach is used to formulate the governing equations in an efficient way. Material stiffness parameters are assumed as non-linear functions of the displacement. The numerical solution is performed in the complex space. The steady-state solution in the complex space is obtained by an iterative process based on the shooting method which imposes the conditions of periodicity with respect to the known value of the period. Extension of the shooting method to the complex space is presented and verified. Non-linear behaviour of material parameters is then optimized by generic probabilistic meta-algorithm, simulated annealing. Dependence of the global optimum on several combinations of leading parameters of the simulated annealing procedure, like neighbourhood definition and annealing schedule, is also studied and analyzed. Procedure is programmed in MATLAB environment.
Resumo:
Based on a retrospective case-control study we evaluated the score system adopted by the Ministry of Health of Brazil (Ministério da Saúde - MS), to diagnose pulmonary tuberculosis (PTB) in childhood. This system is independent of bacteriological or histopathological data to define a very likely (> or = 40 points), possible (30-35 points) or unlikely (< or = 25 points) diagnosis of tuberculosis. Records of hospitalized non-infected HIV children at the Instituto de Puericultura e Pediatria Martagão Gesteira of Federal University of Rio de Janeiro (IPPMG-UFRJ), were reviewed. Patients were adjusted for age and divided in two different groups: 45 subjects in the case group (culture-positive) [mean of age = 10.64 mo; SD 9.66]; and 96 in the control group (culture-negative and clinic criteria that dismissed the disease) [mean of age = 11.79 mo.; SD 11.31]. Among the variables analyzed, the radiological status had the greater impact into the diagnosis (OR = 25.39), followed by exposure to adult with tuberculosis (OR = 10.67), tuberculin skin test >10mm (OR = 8.23). The best cut-off point to the diagnosis of PTB was 30 points, where the score system was more accurate, with sensitivity of 88.9% and specificity of 86.5%.
Resumo:
Nowadays, data centers are large energy consumers and the trend for next years is expected to increase further, considering the growth in the order of cloud services. A large portion of this power consumption is due to the control of physical parameters of the data center (such as temperature and humidity). However, these physical parameters are tightly coupled with computations, and even more so in upcoming data centers, where the location of workloads can vary substantially due, for example, to workloads being moved in the cloud infrastructure hosted in the data center. Therefore, managing the physical and compute infrastructure of a large data center is an embodiment of a Cyber-Physical System (CPS). In this paper, we describe a data collection and distribution architecture that enables gathering physical parameters of a large data center at a very high temporal and spatial resolution of the sensor measurements. We think this is an important characteristic to enable more accurate heat-flow models of the data center and with them, find opportunities to optimize energy consumptions. Having a high-resolution picture of the data center conditions, also enables minimizing local hot-spots, perform more accurate predictive maintenance (failures in all infrastructure equipments can be more promptly detected) and more accurate billing. We detail this architecture and define the structure of the underlying messaging system that is used to collect and distribute the data. Finally, we show the results of a preliminary study of a typical data center radio environment.
Resumo:
Potentiometric sensors are typically unable to carry out on-site monitoring of environmental drug contaminants because of their high limits of detection (LODs). Designing a novel ligand material for the target analyte and managing the composition of the internal reference solution have been the strategies employed here to produce for the first time a potentiometric-based direct reading method for an environmental drug contaminant. This concept has been applied to sulfamethoxazole (SMX), one of the many antibiotics used in aquaculture practices that may occur in environmental waters. The novel ligand has been produced by imprinting SMX on the surface of graphitic carbon nanostructures (CN) < 500 nm. The imprinted carbon nanostructures (ICN) were dispersed in plasticizer and entrapped in a PVC matrix that included (or not) a small amount of a lipophilic additive. The membrane composition was optimized on solid-contact electrodes, allowing near-Nernstian responses down to 5.2 μg/mL and detecting 1.6 μg/mL. The membranes offered good selectivity against most of the ionic compounds in environmental water. The best membrane cocktail was applied on the smaller end of a 1000 μL micropipette tip made of polypropylene. The tip was then filled with inner reference solution containing SMX and chlorate (as interfering compound). The corresponding concentrations were studied for 1 × 10−5 to 1 × 10−10 and 1 × 10−3 to 1 × 10−8 mol/L. The best condition allowed the detection of 5.92 ng/L (or 2.3 × 10−8 mol/L) SMX for a sub-Nernstian slope of −40.3 mV/decade from 5.0 × 10−8 to 2.4 × 10−5 mol/L.
Resumo:
RESUMO - A preocupação com os conhecimentos, atitudes, crenças e práticas, no que concerne à utilização de radiações ionizantes para fins de diagnóstico, e a sensibilização de todos os agentes envolvidos, médicos, técnicos, físicos, utentes e responsáveis pela Saúde Publica, relativamente aos níveis de radiação emitida nos exames de Tomografia Computorizada (TC), assume particular importância no domínio da Saúde Pública, na medida em que é necessário influenciar o desenvolvimento de práticas que promovam, auditem e garantam a prestação do controlo da qualidade radiológica e dosimétrica nos serviços de Radiologia a nível Nacional. Para tal, e no âmbito da publicação de estudos já realizados ao nível da União Europeia, ―Orientações Europeias dos Critérios de Qualidade para a Tomografia Computorizada (1999) ‖, é proposto estabelecer orientações na realização de estudos que permitam, numa primeira fase, estabelecer a comparação com os resultados obtidos pelos mecanismos de Controlo da Qualidade (CQ), analisar e proceder aos ajustes (se necessário) e, numa segunda fase, implementar uma moldura sistemática de avaliação periódica dos níveis de dose de radiação por exame TC e que permita a monitorização dos dados. Nesse sentido, propõe-se a realização de um Estudo Nacional que envolva a rede hospitalar pública, privada e universitária, partindo da metodologia utilizada em estudos prévios noutros países da Europa, como seja, selecção do equipamento de TC existente na Instituição Hospitalar, onde serão reunidas informações através do preenchimento de questionários relativos ao equipamento a utilizar. Serão recolhidos dados relativos ao utente, ao equipamento e parâmetros de aquisição de imagem, que permitam identificar os níveis de referência de diagnóstico (NRD) em TC, na realidade Portuguesa. Foi efectuado um estudo piloto numa instituição EPE e os valores obtidos não são significativos, nem podem assumir valor preditivo dado o reduzido tamanho da amostra. Apesar disso, sugerem a existência de parâmetros que podem ser alterados e com isso podem fazer variar a dose de radiação utilizada. ENSP/UNL Maria de Fátima Vaz de Carvalho 5 Espera-se obter com este estudo, como foi referido, a base do estabelecimento dos NRD em TC em Portugal. ----------------- ABSTRACT - The purpose of this study, in an empirical point of view, emerges from concern with the knowledge, attitudes, beliefs and practices regarding the use of ionizing radiation for diagnostic purposes and awareness of all actors involved, medical physical, technical, and responsible public health for the development of practices that promote, audited and ensure the provision of radiological quality control and dosing in radiology service at national level. In view of the complexity and characteristics involved in relation to ionizing radiation, all assume their part in protecting the physical integrity of each user and a global perspective, to ensure the safeguarding of public health, while global and globalizing factor. To this end, and in the context of the publication of studies already carried out at European Union level, "European guidelines for quality criteria for computed tomography", it is proposed to establish guidelines in conducting studies to initially establish the comparison with the results obtained by QC and make adjustments if necessary, and subsequently implement a systematic periodic assessment frame that allows monitoring of data. Accordingly, it is proposed to conduct a national study involving the public network, private and University hospitals, that extends from the methodology used in previous studies in other countries of Europe, as is, selection of equipment of existing CT in Hospital Institution, where information will be gathered by filling out questionnaires concerning the equipment to be used. Data will be collected for the wearer, equipment and parameters of image acquisition, identifying diagnostic reference levels (NRD) in CT in Portuguese fact. A pilot study was carried out in an institution EPE and the values obtained are not significant, nor can they take predictive value given the small sample size. Despite this, suggest the existence of parameters that can be changed and this can vary the dose of radiation used It is hoped to get with this study, as mentioned, the basis of the establishment of NRD in CT in Portugal.
Resumo:
This paper employs the Lyapunov direct method for the stability analysis of fractional order linear systems subject to input saturation. A new stability condition based on saturation function is adopted for estimating the domain of attraction via ellipsoid approach. To further improve this estimation, the auxiliary feedback is also supported by the concept of stability region. The advantages of the proposed method are twofold: (1) it is straightforward to handle the problem both in analysis and design because of using Lyapunov method, (2) the estimation leads to less conservative results. A numerical example illustrates the feasibility of the proposed method.
Resumo:
The shifted Legendre orthogonal polynomials are used for the numerical solution of a new formulation for the multi-dimensional fractional optimal control problem (M-DFOCP) with a quadratic performance index. The fractional derivatives are described in the Caputo sense. The Lagrange multiplier method for the constrained extremum and the operational matrix of fractional integrals are used together with the help of the properties of the shifted Legendre orthonormal polynomials. The method reduces the M-DFOCP to a simpler problem that consists of solving a system of algebraic equations. For confirming the efficiency and accuracy of the proposed scheme, some test problems are implemented with their approximate solutions.
Resumo:
Background: A new method for determining serum specific IgE (IMMULITE“ 2000 3gAllergy) has recently become available. Objective: To evaluate the clinical performance of IMMULITE 2000 in the diagnosis of cow’s milk allergy compared with that of UniCAP“. Additionally, we verified the behavior of both methods at two diagnostic decision points proposed by other authors. Methods: The study population consisted of 31 children with cow’s milk allergy (group A) and a control group of 19 atopic children without food allergy(group B). A blood sample from each child was tested using both methods and the results were compared. Results: In group A, the values for cow’s milk IgE ranged from 0.35 kU/L (the lowest common detection limit) to above 100 kU/L. In group B, the values were less than 1.1 kU/L for IMMULITE 2000 and less than 1.6 kU/L for UniCAP. An agreement of 90 % in IgE classes was obtained. Both methods demonstrated exactly the same diagnostic performance(sensitivity: 100 %; specificity: 78.9 %; negative predictive value: 100%; positive predictive value: 84.6%;efficiency: 90.2 %). The evaluation of the two methods at the two different decision points proposed in the literature showed a better positive predictive value with UniCAP, but we obtained equivalent performance with IMMULITE 2000 by choosing higher cutoff values. Conclusions: We conclude that IMMULITE 2000 is as effective as UniCAP in the diagnosis of cow’s milk allergy. Both methods can be used to obtain site-specific decision points that are population, age and disease dependent.
Resumo:
This investigation aimed to design a strategy for echinococcosis control in Santana do Livramento county, an endemic area in state of Rio Grande do Sul (Brazil). Fecal samples from 65 dogs were obtained from urban, suburban and rural areas. Purging with Arecoline Bromhidrate (AB) was done to visualize Echinococcus granulosus, and Enzyme Linked Immunosorbent Assay (ELISA) was performed to detect parasite coproantigen. Samples were obtained at the beginning and at the end of treatment with Praziquantel. A third fecal sampling was also done in rural areas four months after the end of treatment. Each dog was treated immediately after the first purging and every 30 days for eight months. In urban and suburban areas no infected dogs were found. In rural areas, first evaluation showed 11.36% and 27.69% of infected dogs by AB and ELISA, respectively. No infected dogs were diagnosed in the second evaluation and in the third evaluation 36.84% and 47.37% infected dogs were identified by AB and ELISA, respectively. Medication program to combat dog infection resulted in successful interruption of parasite transmission, but the project failed to create awareness of the need for dog prophylaxis among rural populations as well as to establish a permanent control program in this municipality.
Resumo:
Postural control deficits are the most disabling aspects of Parkinson's disease (PD), resulting in decreased mobility and functional independence. The aim of this study was to assess the postural control stability, revealed by variables based on the centre of pressure (CoP), in individuals with PD while performing a sit-to-stand-to-sit sequence under single- and dual-task conditions. An observational, analytical and cross-sectional study was performed. The sample consisted of 9 individuals with PD and 9 healthy controls. A force platform was used to measure the CoP displacement and velocity during the sit-to-stand-to-sit sequence. The results were statistically analysed. Individuals with PD required greater durations for the sit-to-stand-to-sit sequence than the controls (p < 0.05). The anteroposterior and mediolateral CoP displacement were higher in the individuals with PD (p < 0.05). However, only the anteroposterior CoP velocity in the stand-to-sit phase (p = 0.006) was lower in the same individuals. Comparing the single- and dual-task conditions in both groups, the duration, the anteroposterior CoP displacement and velocity were higher in the dual-task condition (p < 0.05). The individuals with PD presented reduced postural control stability during the sit-to-stand-to-sit sequence, especially when under the dual-task condition. These individuals have deficits not only in motor performance, but also in cognitive performance when performing the sit-to-stand-to-sit sequence in their daily life tasks. Moreover, both deficits tend to be intensified when two tasks are performed simultaneously.
Resumo:
In this work the mission control and supervision system developed for the ROAZ Autonomous Surface Vehicle is presented. Complexity in mission requirements coupled with flexibility lead to the design of a modular hierarchical mission control system based on hybrid systems control. Monitoring and supervision control for a vehicle such as ROAZ mission is not an easy task using tools with low complexity and yet powerful enough. A set of tools were developed to perform both on board mission control and remote planning and supervision. “ROAZ- Mission Control” was developed to be used in support to bathymetric and security missions performed in river and at seas.
Resumo:
Underwater acoustic networks can be quite effective to establish communication links between autonomous underwater vehicles (AUVs) and other vehicles or control units, enabling complex vehicle applications and control scenarios. A communications and control framework to support the use of underwater acoustic networks and sample application scenarios are described for single and multi-AUV operation.