965 resultados para Axial Rotation Exertion
Resumo:
We report on a new measurement of the neutron beta-asymmetry parameter A with the instrument \perkeo. Main advancements are the high neutron polarization of P=99.7(1) from a novel arrangement of super mirror polarizers and reduced background from improvements in beam line and shielding. Leading corrections were thus reduced by a factor of 4, pushing them below the level of statistical error and resulting in a significant reduction of systematic uncertainty compared to our previous experiments. From the result A0=−0.11996(58), we derive the ratio of the axial-vector to the vector coupling constant λ=gA/gV=−1.2767(16)
Resumo:
The Hox gene products are transcription factors involved in specifying regional identity along the anteroposterior body axis. In Drosophila, where these genes are known as HOM-C (Homeotic-complex) genes and where they have been most extensively studied, they are expressed in restricted domains along the anteroposterior axis with different anterior limits. Genetic analysis of a large number of gain- and loss-of-function alleles of these genes has revealed that these genes are important in specifying segmental identity at their anterior limits of expression. Furthermore, there is a functional dominance of posterior genes over anterior genes, such that posterior genes can dominantly specify their developmental programs in spite of the expression of more anterior genes in the same segment. In the mouse, there are four clusters of HOM-C genes, called Hox genes. Thus, there may be up to four genes, called paralogs, that are more highly homologous to each other and to their Drosophila homolog than they are to the other mouse Hox genes. The single mutants for two paralogous genes, hoxa-4 and hoxd-4, presented in this dissertation, are similar to several other mouse Hox mutants in that they show partial, incompletely penetrant homeotic transformations of vertebrae at their anterior limit of expression. These mutants were then bred with hoxb-4 mutants (Ramirez-Solis, et al. 1993) to generate the three possible double mutant combinations as well as the triple mutant. The skeletal phenotypes of these group 4 Hox compound mutants displayed clear alterations in regional identity, such that a nearly complete transformation towards the morphology of the first cervical vertebra occurs. These results suggest a certain degree of functional redundancy among paralogous genes in specifying regional identity. Furthermore, there was a remarkable dose-dependent increase in the number of vertebrae transformed to a first cervical vertebra identity, including the second through the fifth cervical vertebrae in the triple mutant. Thus, these genes are required in a larger anteroposterior domain than is revealed by the single mutant phenotypes alone, such that multiple mutations in these genes result in transformations of vertebrae that are not at their anterior limit of expression. ^
Resumo:
BACKGROUND: Impaired manual dexterity is frequent and disabling in patients with multiple sclerosis (MS). Therefore, convenient, quick and validated tests for manual dexterity in MS patients are needed. OBJECTIVE: The aim of this study was to validate the Coin Rotation task (CRT) to examine manual dexterity in patients with MS. DESIGN: Cross-sectional study. METHODS: 101 outpatients with MS were assessed with the CRT, the Expanded Disability Status Scale (EDSS), the Scale for the assessment and rating of ataxia (SARA), the Modified Ashworth Scale (MAS), and their muscle strength and sensory deficits of the hands were noted. Concurrent validity and diagnostic accuracy of the CRT were determined by comparison with the Nine Hole Peg Test (9HPT). Construct validity was determined by comparison with a valid dexterity questionnaire. Multiple regression analysis was done to explore correlations of the CRT with the EDSS, SARA, MAS, muscle strength and sensory deficits. RESULTS: The CRT correlated significantly with the 9HPT (r=.73, p<.0001) indicating good concurrent validity. The cut-off values for the CRT relative to the 9HPT were 18.75 seconds for the dominant (sensitivity: 81.5%; specificity 80.0%) and 19.25 seconds for the non-dominant hand (sensitivity: 90.3%; specificity: 81.8%) demonstrating good diagnostic accuracy. Furthermore, the CRT correlated significantly with the dexterity questionnaire (r=-.49, p<.0001) indicating moderate construct validity. Multiple regression analyses revealed that the EDSS was the strongest predictor for impaired dexterity. LIMITATIONS: Mostly relapsing-remitting MS patients with an EDSS up to 7 were examined. CONCLUSIONS: This study validates the CRT as a test that can be used easily and quickly to evaluate manual dexterity in patients with MS.
Resumo:
The European Commission’s proposals for the Legislative Framework of the Common Agricultural Policy (CAP) in the period 2014-2020 include, inter alia, the introduction of a “strong greening component”. For the first time, all EU farmers in receipt of support are to “go beyond the requirements of cross compliance and deliver environmental and climate benefits as part of their everyday activities crop diversification as a contribution to all EU farmers in receipt of support go beyond the requirements of cross compliance and deliver environmental and climate benefits as part of their everyday activities.” In a legal opinion prepared at the request of APRODEV, the Association of World Council of Churches related Development Organisations in Europe (www.aprodev.eu), Christian Häberli examines the WTO implications of this proposal, as compared with an alternative proposal to rather link direct payments to crop rotation. The conclusions are twofold: 1. Crop rotation is at least as likely to be found Green Box-compatible as crop diversification. Moreover, it will be more difficult to argue that crop diversification is “not more than minimally production-distorting” because it entails for most farmers less cost and work. 2. Even if (either of the two cropping schemes) were to be found “amber”, the EU would not have to relinquish this conditionality. This is because the direct payments involved would in all likelihood not, together with the other price support instruments, exceed the amount available under the presently scheduled maximum.
Resumo:
INTRODUCTION An accurate description of the biomechanical behavior of the spine is crucial for the planning of scoliotic surgical correction as well as for the understanding of degenerative spine disorders. The current clinical assessments of spinal mechanics such as side-bending or fulcrum-bending tests rely on the displacement of the spine observed during motion of the patient. Since these tests focused solely on the spinal kinematics without considering mechanical loads, no quantification of the mechanical flexibility of the spine can be provided. METHODS A spinal suspension test (SST) has been developed to simultaneously monitor the force applied on the spine and the induced vertebral displacements. The system relies on cervical elevation of the patient and orthogonal radiographic images are used to measure the position of the vertebras. The system has been used to quantify the spinal flexibility on five AIS patients. RESULTS Based on the SST, the overall spinal flexibility varied between 0.3 °/Nm for the patient with the stiffer curve and 2 °/Nm for the less rigid curve. A linear correlation was observed between the overall spinal flexibility and the change in Cobb angle. In addition, the segmental flexibility calculated for five segments around the apex was 0.13 ± 0.07 °/Nm, which is similar to intra-operative stiffness measurements previously published. CONCLUSIONS In summary, the SST seems suitable to provide pre-operative information on the complex functional behavior and stiffness of spinal segments under physiological loading conditions. Such tools will become increasingly important in the future due to the ever-increasing complexity of the surgical instrumentation and procedures.
Resumo:
Ex vivo porcine retina laser lesions applied with varying laser power (20 mW–2 W, 10 ms pulse, 196 lesions) are manually evaluated by microscopic and optical coherence tomography (OCT) visibility, as well as in histological sections immediately after the deposition of the laser energy. An optical coherence tomography system with 1.78 um axial resolution specifically developed to image thin retinal layers simultaneously to laser therapy is presented, and visibility thresholds of the laser lesions in OCT data and fundus imaging are compared. Optical coherence tomography scans are compared with histological sections to estimate the resolving power for small optical changes in the retinal layers, and real-time time-lapse scans during laser application are shown and analyzed quantitatively. Ultrahigh-resolution OCT inspection features a lesion visibility threshold 40–50 mW (17 reduction) lower than for visual inspection. With the new measurement system, 42 of the lesions that were invisible using state-of-the-art ophthalmoscopic methods could be detected.
Resumo:
OBJECTIVE To evaluate the initiation of and response to tumor necrosis factor (TNF) inhibitors for axial spondyloarthritis (axSpA) in private rheumatology practices versus academic centers. METHODS We compared newly initiated TNF inhibition for axSpA in 363 patients enrolled in private practices with 100 patients recruited in 6 university hospitals within the Swiss Clinical Quality Management (SCQM) cohort. RESULTS All patients had been treated with ≥ 1 nonsteroidal antiinflammatory drug and > 70% of patients had a baseline Bath Ankylosing Spondylitis Disease Activity Index (BASDAI) ≥ 4 before anti-TNF agent initiation. The proportion of patients with nonradiographic axSpA (nr-axSpA) treated with TNF inhibitors was higher in hospitals versus private practices (30.4% vs 18.7%, p = 0.02). The burden of disease as assessed by patient-reported outcomes at baseline was slightly higher in the hospital setting. Mean levels (± SD) of the Ankylosing Spondylitis Disease Activity Score were, however, virtually identical in private practices and academic centers (3.4 ± 1.0 vs 3.4 ± 0.9, p = 0.68). An Assessment of SpondyloArthritis international Society (ASAS40) response at 1 year was reached for ankylosing spondylitis in 51.7% in private practices and 52.9% in university hospitals (p = 1.0) and for nr-axSpA in 27.5% versus 25.0%, respectively (p = 1.0). CONCLUSION With the exception of a lower proportion of patients with nr-axSpA newly treated with anti-TNF agents in private practices in comparison to academic centers, adherence to ASAS treatment recommendations for TNF inhibition was equally high, and similar response rates to TNF blockers were achieved in both clinical settings.
Resumo:
Aims. Approach observations with the Optical, Spectroscopic, and Infrared Remote Imaging System (OSIRIS) experiment onboard Rosetta are used to determine the rotation period, the direction of the spin axis, and the state of rotation of comet 67P’s nucleus. Methods. Photometric time series of 67P have been acquired by OSIRIS since the post wake-up commissioning of the payload in March 2014. Fourier analysis and convex shape inversion methods have been applied to the Rosetta data as well to the available ground-based observations. Results. Evidence is found that the rotation rate of 67P has significantly changed near the time of its 2009 perihelion passage, probably due to sublimation-induced torque. We find that the sidereal rotation periods P1 = 12.76129 ± 0.00005 h and P2 = 12.4043 ± 0.0007 h for the apparitions before and after the 2009 perihelion, respectively, provide the best fit to the observations. No signs of multiple periodicity are found in the light curves down to the noise level, which implies that the comet is presently in a simple rotation state around its axis of largest moment of inertia. We derive a prograde rotation model with spin vector J2000 ecliptic coordinates λ = 65° ± 15°, β = + 59° ± 15°, corresponding to equatorial coordinates RA = 22°, Dec = + 76°. However, we find that the mirror solution, also prograde, at λ = 275° ± 15°, β = + 50° ± 15° (or RA = 274°, Dec = + 27°), is also possible at the same confidence level, due to the intrinsic ambiguity of the photometric problem for observations performed close to the ecliptic plane.