905 resultados para Automated quantification
Resumo:
Background: Prostate cancer is a serious public health problem that affects quality of life and has a significant mortality rate. The aim of the present study was to quantify the fractal dimension and Shannon’s entropy in the histological diagnosis of prostate cancer. Methods: Thirty-four patients with prostate cancer aged 50 to 75 years having been submitted to radical prostatectomy participated in the study. Histological slides of normal (N), hyperplastic (H) and tumor (T) areas of the prostate were digitally photographed with three different magnifications (40x, 100x and 400x) and analyzed. The fractal dimension (FD), Shannon’s entropy (SE) and number of cell nuclei (NCN) in these areas were compared. Results: FD analysis demonstrated the following significant differences between groups: T vs. N and H vs. N groups (p < 0.05) at a magnification of 40x; T vs. N (p < 0.01) at 100x and H vs. N (p < 0.01) at 400x. SE analysis revealed the following significant differences groups: T vs. H and T vs. N (p < 0.05) at 100x; and T vs. H and T vs. N (p < 0.001) at 400x. NCN analysis demonstrated the following significant differences between groups: T vs. H and T vs. N (p < 0.05) at 40x; T vs. H and T vs. N (p < 0.0001) at 100x; and T vs. H and T vs. N (p < 0.01) at 400x. Conclusions: The quantification of the FD and SE, together with the number of cell nuclei, has potential clinical applications in the histological diagnosis of prostate cancer.
Resumo:
The content of isoorientin in passion fruit rinds (Passiflora edulis fo. flavicarpa O. Degener) was determined by HPTLC (high performance thin layer chromatography) with densitometric analysis. The results revealed a higher amount of isoorientin in healthy rinds of P. edulis (92.275 ± 0.610 mg L-1) than in rinds with typical symptoms of PWV (Passion fruit Woodiness Virus) infection (28.931 ± 0.346 mg L-1). The HPTLC data, allied to assays of radical scavenging activity, suggest the potential of P. edulis rinds as a natural source of flavonoids or as a possible functional food.
Resumo:
A simple, rapid and selective method using high-performance liquid chromatography with ultraviolet detection (267 nm) was applied for the determination of tryptophan in plasma. Separation was carried out on a C18 column (150 x 4.6 mm internal diameter) in 6 min. The mobile phase consisted of 5 mM the sodium acetate and acetonitrile (92:8, v/v). The method was shown to be precise and accurate, and good recovery of analyte was achieved, characterizing the method as efficient and reliable for use in laboratory analysis.
Resumo:
The development of new procedures for quickly obtaining accurate information on the physiological potential of seed lots is essential for developing quality control programs for the seed industry. In this study, the effectiveness of an automated system of seedling image analysis (Seed Vigor Imaging System - SVIS) in determining the physiological potential of sun hemp seeds and its relationship with electrical conductivity tests, were evaluated. SVIS evaluations were performed three and four days after sowing and data on the vigor index and the length and uniformity of seedling growth were collected. The electrical conductivity test was made on 50 seed replicates placed in containers with 75 mL of deionised water at 25 ºC and readings were taken after 1, 2, 4, 8 and 16 hours of imbibition. Electrical conductivity measurements at 4 or 8 hours and the use of the SVIS on 3-day old seedlings can effectively detect differences in vigor between different sun hemp seed lots.
Resumo:
OBJETIVOS: Traduzir, adaptar culturalmente para o Brasil o ATDM Satisfaction Scales e avaliar a confiabilidade da versão adaptada em adultos brasileiros com DM. MÉTODOS: Estudo metodológico, cujo processo de adaptação cultural incluiu: tradução, comitê de juízes, retrotradução, análise semântica e pré-teste. Este estudo incluiu uma amostra de 39 adultos brasileiros com DM cadastrados em um programa educativo do interior paulista. RESULTADOS: A versão adaptada do instrumento mostrou boa aceitação com fácil compreensão dos itens pelos participantes, com confiabilidade variando entre 0,30 e 0,43. CONCLUSÃO: Após a análise das propriedades psicométricas e finalização do processo de validação no País, o instrumento poderá ser utilizado por pesquisadores brasileiros, possibilitando ser comparado com outras culturas.
Resumo:
A method for the simultaneous quantification of lycopene, β-carotene, retinol and α-tocopherol by high-performance liquid chromatography (HPLC) with Vis/fluorescence detection with isocratic elution was optimized and validated. The method consists of a rapid and simple liquid-liquid extraction procedure and a posterior quantification of extracted supernatants by HPLC. Aliquots of plasma were stored at -20°C for three months for stability study. The methodology was applied to samples from painters and individuals not exposed to paints (n = 75). The assay was linear for all vitamins (r > 0.99). Intra- and inter-run precisions were obtained with coefficient of variation smaller than 5%. The accuracies ranged from 0.29 to -5.80% and recoveries between 92.73 and 101.97%. Plasma samples and extracted supernatants were stable for 60 days at -20°C. A significant decrease of lycopene, β-carotene and retinol concentrations in plasma from exposed individuals compared to non-exposed individuals (p < 0.05) was observed. The method is simple, reproducible, precise, accurate and sensitive, and can be routinely utilized in clinical laboratories.
Resumo:
The cellular rheology has recently undergone a rapid development with particular attention to the cytoskeleton mechanical properties and its main components - actin filaments, intermediate filaments, microtubules and crosslinked proteins. However it is not clear what are the cellular structural changes that directly affect the cell mechanical properties. Thus, in this work, we aimed to quantify the structural rearrangement of these fibers that may emerge in changes in the cell mechanics. We created an image analysis platform to study smooth muscle cells from different arteries: aorta, mammary, renal, carotid and coronary and processed respectively 31, 29, 31, 30 and 35 cell image obtained by confocal microscopy. The platform was developed in Matlab (MathWorks) and it uses the Sobel operator to determine the actin fiber image orientation of the cell, labeled with phalloidin. The Sobel operator is used as a filter capable of calculating the pixel brightness gradient, point to point, in the image. The operator uses vertical and horizontal convolution kernels to calculate the magnitude and the angle of the pixel intensity gradient. The image analysis followed the sequence: (1) opens a given cells image set to be processed; (2) sets a fix threshold to eliminate noise, based on Otsu's method; (3) detect the fiber edges in the image using the Sobel operator; and (4) quantify the actin fiber orientation. Our first result is the probability distribution II(Δθ) to find a given fiber angle deviation (Δθ) from the main cell fiber orientation θ0. The II(Δθ) follows an exponential decay II(Δθ) = Aexp(-αΔθ) regarding to its θ0. We defined and determined a misalignment index α of the fibers of each artery kind: coronary αCo = (1.72 ‘+ or =’ 0.36)rad POT -1; renal αRe = (1.43 + or - 0.64)rad POT -1; aorta αAo = (1.42 + or - 0.43)rad POT -1; mammary αMa = (1.12 + or - 0.50)rad POT -1; and carotid αCa = (1.01 + or - 0.39)rad POT -1. The α of coronary and carotid are statistically different (p < 0.05) among all analyzed cells. We discussed our results correlating the misalignment index data with the experimental cell mechanical properties obtained by using Optical Magnetic Twisting Cytometry with the same group of cells.
Resumo:
A rapid, sensitive and specific method for quantifying hydroxocobalamin in human plasma using paracetamol as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using an organic solvent (ethanol 100%; -20°C). The extracts were analyzed by high performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-MS-MS). Chromatography was performed on Prevail C8 3 μm, analytical column (2.1×100 mm i.d.). The method had a chromatographic run time of 3.4 min and a linear calibration curve over the range 5-400 ng.mL-1 (r>0.9983). The limit of quantification was 5 ng.mL-1. The method was also validated without the use of the internal standard. The precision in the intra-batch validation with IS was 9.6%, 8.9%, 1.0% and 2.8% whereas without IS was 9.2%, 8.2%, 1.8% and 1.5% for 5, 15, 80 and 320 ng/mL, respectively. The accuracy in intra-batch validation with IS was 108.9%, 99.9%, 98.9% and 99.0% whereas without IS was 101.1%, 99.3%, 97.5% and 92.5% for 5, 15, 80 and 320 ng/mL, respectively. The precision in the inter-batch validation with IS was 9.4%, 6.9%, 4.6% and 5.5% whereas without IS was 10.9%, 6.4%, 5.0% and 6.2% for 5, 15, 80 and 320 ng/mL, respectively. The accuracy in inter-batch validation with IS was 101.9%, 104.1%, 103.2% and 99.7% whereas without IS was 94.4%, 101.2%, 101.6% and 96.0% for 5, 15, 80 and 320 ng/mL, respectively. This HPLC-MS-MS procedure was used to assess the pharmacokinetics of Hydroxo cobalamin following intramuscular injection 5000 μg in healthy volunteers of both sexes (10 males and 10 females). The volunteers had the following clinical characteristics (according to gender and expressed as mean ± SD [range]): males: age: 32.40 ± 8.00 y [23.00-46.00], height: 1.73 ± 0.07 m [1.62-1.85], body weight: 72.48 ± 10.22 Kg [60.20- 88.00]; females: age: 28.60 ± 9.54 y [18.00-44.00], height: 1.60 ± 0.05 m [1.54-1.70], body weight: 58.64 ± 6.09 Kg [51.70- 66.70]. The following pharmacokinetic parameters were obtained from the hydroxocobalamin plasma concentration vs. time curves: AUClast, T1/2, Tmax, Vd, Cl, Cmax and Clast. The pharmacokinetic parameters were 120 (± 25) ng/mL for Cmax, 2044 (± 641) ng.h/mL for AUClast, 8 (± 3.2) ng.mL-1 for Clast, 38 (± 15.8) hr for T1/2 and 2.5 (range 1-6) hr for Tmax. Female volunteers presented significant (p=0.0136) lower AUC (1706 ± 704) ng.h/mL) and larger (p=0.0205) clearance (2.91 ± 1.41 L/hr), as compared to male 2383 ± 343 ng.h/mL and 1.76 ± 0.23 L/hr, respectively. These pharmacokinetic differences could explain the higher prevalence of vitamin B12 deficiency in female patients. The method described validated well without the use of the internal standard and this approach should be investigated in other HPLC-MS-MS methods.
Resumo:
ZUSAMMENFASSUNG Langzeitbeobachtungsstudien zur Landschaftsdynamik inSahelländern stehen generell einem defizitären Angebot anquantitativen Rauminformationen gegenüber. Der in Malivorgefundene lokal- bis regionalräumliche Datenmangelführte zu einer methodologischen Studie, die die Entwicklungvon Verfahren zur multi-temporalen Erfassung und Analyse vonLandschaftsveränderungsdaten beinhaltet. Für den RaumWestafrika existiert in großer Flächenüberdeckunghistorisches Fernerkundungsmaterial in Form hochauflösenderLuftbilder ab den 50er Jahren und erste erdbeobachtendeSatellitendaten von Landsat-MSS ab den 70er Jahren.Multitemporale Langzeitanalysen verlangen zur digitalenReproduzierbarkeit, zur Datenvergleich- undObjekterfaßbarkeit die a priori-Betrachtung derDatenbeschaffenheit und -qualität. Zwei, ohne verfügbare, noch rekonstruierbareBodenkontrolldaten entwickelte Methodenansätze zeigen nichtnur die Möglichkeiten, sondern auch die Grenzen eindeutigerradiometrischer und morphometrischerBildinformationsgewinnung. Innerhalb desÜberschwemmungsgunstraums des Nigerbinnendeltas im ZentrumMalis stellen sich zwei Teilstudien zur Extraktion vonquantitativen Sahelvegetationsdaten den radiometrischen undatmosphärischen Problemen:1. Präprozessierende Homogenisierung von multitemporalenMSS-Archivdaten mit Simulationen zur Wirksamkeitatmosphärischer und sensorbedingter Effekte2. Entwicklung einer Methode zur semi-automatischenErfassung und Quantifizierung der Dynamik derGehölzbedeckungsdichte auf panchromatischenArchiv-Luftbildern Die erste Teilstudie stellt historischeLandsat-MSS-Satellitenbilddaten für multi-temporale Analysender Landschaftsdynamik als unbrauchbar heraus. In derzweiten Teilstudie wird der eigens, mittelsmorphomathematischer Filteroperationen für die automatischeMusterkennung und Quantifizierung von Sahelgehölzobjektenentwickelte Methodenansatz präsentiert. Abschließend wird die Forderung nach kosten- undzeiteffizienten Methodenstandards hinsichtlich ihrerRepräsentativität für die Langzeitbeobachtung desRessourceninventars semi-arider Räume sowie deroperationellen Transferierbarkeit auf Datenmaterial modernerFernerkundungssensoren diskutiert.
Resumo:
Zusammenfassung:In dieser Studie werden Deformationsprozesse im mesozoischen Torlesse Akkretionskeil (Neuseeland) quantifiziert, um Aufschluß über die Dynamik in Akkretionskeilen zu erhalten. Absolute und relative Verformungsmessungen zeigen sowohl im lokalen als auch regionalen Maßstab eine stark heterogene Deformation des Torlesse Keils. Die regionale Deformation wurde mit Hilfe einer Tensordurchschnittsberechnung, unter Benutzung einzelner lokaler Verformungsdaten, als uniaxiale Verkürzung entlang einer subvertikalen, maximalen Verkürzungsachse charakterisiert. Absolute Verformungsmessungen an niedriggradigen Metasandsteinen belegen darüber hinaus durchschnittliche Volumenverluste von ca. 20% SiO2. Volumenveränderungen in tieferkrustalen Aufschlüssen wurden mittels einer geochemischen Massenbilanzanalyse abgeschätzt. Chemische Zusammensetzungen höhergradiger Zonen weichen je nach Grad der Volumenverformung von der Protolitzusammensetzung ab und zeigen somit Verluste von 15% SiO2 an. Da Speicherorte für das gelöste Material nicht bekannt sind, muss angenommen werden, dass das Material aus dem Keil abtransportiert wurde. Die Verformungsergebnisse geben weiterhin Aufschluß über den Grad der Kopplung zwischen Akkretionskeil und subduzierter Platte. Die ermittelten Scherwerte in den Gesteinen liegen deutlich unter den zu erwartenden Scherwerten, die mittels eines einfachen Modells berechnet wurden, das sowohl verschiedene Konvergenzgeschwindigkeiten als auch Exhumierungsraten berücksichtigt. Dies belegt, dass der Torlesse Keil stark von der subduzierten pazifischen Platte entkoppelt war und die Deformation hauptsächlich durch den Fluß der Sedimente in und aus dem Keil bestimmt wurde.
Resumo:
3D video-fluoroscopy is an accurate but cumbersome technique to estimate natural or prosthetic human joint kinematics. This dissertation proposes innovative methodologies to improve the 3D fluoroscopic analysis reliability and usability. Being based on direct radiographic imaging of the joint, and avoiding soft tissue artefact that limits the accuracy of skin marker based techniques, the fluoroscopic analysis has a potential accuracy of the order of mm/deg or better. It can provide fundamental informations for clinical and methodological applications, but, notwithstanding the number of methodological protocols proposed in the literature, time consuming user interaction is exploited to obtain consistent results. The user-dependency prevented a reliable quantification of the actual accuracy and precision of the methods, and, consequently, slowed down the translation to the clinical practice. The objective of the present work was to speed up this process introducing methodological improvements in the analysis. In the thesis, the fluoroscopic analysis was characterized in depth, in order to evaluate its pros and cons, and to provide reliable solutions to overcome its limitations. To this aim, an analytical approach was followed. The major sources of error were isolated with in-silico preliminary studies as: (a) geometric distortion and calibration errors, (b) 2D images and 3D models resolutions, (c) incorrect contour extraction, (d) bone model symmetries, (e) optimization algorithm limitations, (f) user errors. The effect of each criticality was quantified, and verified with an in-vivo preliminary study on the elbow joint. The dominant source of error was identified in the limited extent of the convergence domain for the local optimization algorithms, which forced the user to manually specify the starting pose for the estimating process. To solve this problem, two different approaches were followed: to increase the optimal pose convergence basin, the local approach used sequential alignments of the 6 degrees of freedom in order of sensitivity, or a geometrical feature-based estimation of the initial conditions for the optimization; the global approach used an unsupervised memetic algorithm to optimally explore the search domain. The performances of the technique were evaluated with a series of in-silico studies and validated in-vitro with a phantom based comparison with a radiostereometric gold-standard. The accuracy of the method is joint-dependent, and for the intact knee joint, the new unsupervised algorithm guaranteed a maximum error lower than 0.5 mm for in-plane translations, 10 mm for out-of-plane translation, and of 3 deg for rotations in a mono-planar setup; and lower than 0.5 mm for translations and 1 deg for rotations in a bi-planar setups. The bi-planar setup is best suited when accurate results are needed, such as for methodological research studies. The mono-planar analysis may be enough for clinical application when the analysis time and cost may be an issue. A further reduction of the user interaction was obtained for prosthetic joints kinematics. A mixed region-growing and level-set segmentation method was proposed and halved the analysis time, delegating the computational burden to the machine. In-silico and in-vivo studies demonstrated that the reliability of the new semiautomatic method was comparable to a user defined manual gold-standard. The improved fluoroscopic analysis was finally applied to a first in-vivo methodological study on the foot kinematics. Preliminary evaluations showed that the presented methodology represents a feasible gold-standard for the validation of skin marker based foot kinematics protocols.