904 resultados para Angulação mésio-distal
Resumo:
Purpose: The aim of this research was to assess, by means of, the bi-dimensional finite element method, the best implant location in the alveolar edge, through stress distribution and support structure displacement of a distal extension removable partial denture associated with an osseointegrated implant of 10.0 x .75 mm, acting as abutment for the denture base.Methods and Materials: Five models in sagittal cut were used to represent: model A-hemi arch containing natural tooth 33 and the distal alveolar edge; model B-similar to model A, but with a conventional removable partial denture to replace the absent teeth; model C (MC)-similar to the previous one, with an implant in the distal region of the edge under the denture base; model D-similar to MC, with the implant in the central region of the edge; model E-similar to MC, with an implant in the mesial region of the edge. With the aid of the finite element program ANSYS 8.0, the models were loaded with strictly vertical forces of 50 N on each cusp tip. Displacement and von Mises Maps were plotted for visualization of results.Results: The introduction of implant diminished the tendency of intrusion of the removable partial denture in all situations. The maximum stress was observed on implant in all situations. Approximating implant in direction of support teeth was benefit for stress distribution.Conclusion: Model D presented the lowest value for maximum tendency to displacement when compared with those found in the other models; model E demonstrated better relief with regard to demand from the abutment tooth; locating the implant near of the abutment tooth influenced positively the distribution of stresses on the analyzed structures.
Resumo:
OBJETIVO: a presente pesquisa clínica, longitudinal e prospectiva, avaliou os efeitos do aparelho Pendex mediante o emprego de modelos de gesso. METODOLOGIA: utilizou-se uma amostra de 30 modelos de gesso, obtidos no início e no final da distalização dos molares superiores com o aparelho Pendex, de 15 jovens brasileiros tratados no Curso de Pós-Graduação, nível de Mestrado em Ortodontia, da Faculdade de Odontologia de Araçatuba - UNESP. RESULTADOS E CONCLUSÕES: os resultados mostraram aumento do perímetro do arco dentário superior com inclinação distal e controle transversal dos primeiros molares superiores.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVO: o presente ensaio científico põe em pauta o efeito imediato da distalização unilateral de molares superiores, lançando mão do distalizador intrabucal Pendex de ação unilateral. METODOLOGIA: o estudo prospectivo foi conduzido em três pacientes na dentadura permanente madura, no estágio de adolescência, que apresentavam uma má oclusão Classe II, subdivisão. O aparelho Pendex foi instalado com a mola distalizadora de TMA, construída apenas no lado direito. A metodologia baseou-se nas radiografias panorâmicas inicial e pós-distalização para quantificar a inclinação axial mesiodistal dos molares superiores. RESULTADOS E CONCLUSÕES: os resultados mostraram que os molares do lado esquerdo mantiveram sua inclinação mesiodistal inicial, sugerindo ancoragem, enquanto os molares do lado direito foram inclinados para distal, à semelhança do que ocorre com a distalização simétrica dos molares superiores, obtida com o aparelho Pendex convencional. Os primeiros molares foram inclinados 11,5º, enquanto os segundos molares foram inclinados 21º para distal.
Resumo:
OBJETIVOS: comparar os valores médios normais das angulações mesiodistais dentárias, propostos por Ursi, em 1989, com as angulações mesiodistais de caninos, pré-molares e molares inferiores em indivíduos com e sem a presença dos terceiros molares inferiores e idades entre 18 e 25 anos. Além disso, foram comparados os valores das angulações mesiodistais desses dentes nessas duas situações. MÉTODOS: foram utilizadas 40 radiografias ortopantomográficas de indivíduos, de ambos os gêneros, que não receberam tratamento ortodôntico, divididos em dois grupos: Grupo I, constituído por 20 radiografias que não apresentavam os terceiros molares inferiores; e Grupo II, formado por 20 radiografias com os terceiros molares inferiores presentes. RESULTADOS E CONCLUSÕES: a análise dos resultados e a análise estatística permitiram concluir que ambos os grupos exibiram pré-molares e molares inferiores mais angulados em sentido mesial, quando comparados à oclusão normal. Por outro lado, a angulação mesiodistal de caninos inferiores mostrou-se semelhante àquela apresentada em casos de oclusão normal. Os dois grupos, quando comparados entre si, exibiram semelhantes valores angulares dos caninos, pré-molares e molares inferiores, de modo que a presença dos terceiros molares não exerceu influência sobre essas angulações mesiodistais dentárias.
Resumo:
The purpose of this study was to evaluate histologically, in dogs, the periodontal healing of 1-walled intraosseous defects in teeth that were subjected to orthodontic movement toward the defects. The defects were surgically created bilaterally at the mesial aspects of the maxillary second premolars and distal aspects of the mandibular second premolars of 4 mongrel dogs. One week after creating the defects, an orthodontic appliance was installed, and the teeth were randomly assigned to 1 of 2 treatment groups: those in the test group received a titanium-molybdenum alloy rectangular wire spring that performed a controlled tipping root movement, and those in the control group received a passive stainless steel wire. Active orthodontic movement of the test teeth lasted 2 months and was followed by a stabilization period of another 2 months, after which the animals were killed. Throughout the study, routine daily plaque control was performed on the dogs with a topical application of a 2% chlorhexicline gel. The results showed no difference between the groups, with some regularization of the defects and periodontal regeneration limited to the apical portion of the defects. Histometric analysis showed a significant difference in bone height; on average, it was 0.53 mm smaller in the test group. It was concluded that orthodontic movement does not interfere with the healing of 1-walled intraosseous defects, with the exception of the linear extent of new bone apposition.
Resumo:
Objective. The aim of this study was to evaluate the use of a collagen-based membrane compared with no treatment on guided bone regeneration by 3-dimensional computerized microtomography (mu CT).Study Design. Defects were created between the mesial and distal premolar roots of the second and third premolars (beagle dogs; n = 8). A collagen-based membrane (Vitala; Osteogenics Biomedical Inc., TX, USA) was placed in one of the defects (membrane group; n = 16), and the other was left untreated (no-membrane group; n = 16). Left and right sides provided healing samples for 2 and 16 weeks. Three-dimensional bone architecture was acquired by mu CT and categorized as fully regenerated (F, bone height and width) or nonregenerated (N).Results. Chi-square tests (95% level of significance) showed that tooth did not have an effect on outcome (P = .5). Significantly higher F outcomes were observed at 16 weeks than 2 weeks (P = .008) and in membrane group than in no-membrane group (P = .008).Conclusions. The collagen-based membrane influenced bone regeneration at the furcation. (Oral Surg Oral Med Oral Pathol Oral Radiol 2012;114:437-443)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: the goal of the present study was to evaluate the microleakage on the cementum/dentin and enamel surfaces in Class 11 restorations, using different kinds of resin composite (microhybrid, flowable, and compactable). Method and materials: Forty human caries-free molars were extracted and selected. Eighty Class 11 standardized cavities were made in the cervical wall at the cementoenamel junction (CEJ) and at the mesial and distal surfaces. The teeth were divided into four groups: G1 - adhesive system + microhybrid resin composite Z100; G2 - adhesive system + compactable resin composite Prodigy Condensable; G3 - adhesive system + flowable resin composite Revolution + Z1 00 resin composite; G4 - adhesive system + Revolution fluid resin + compactable resin composite Prodigy Condensable. The adhesive system used in this study was Scotchbond Multi-Purpose Plus. The specimens were thermocycled in baths of 5degreesC and 55degreesC for 1,000 cycles and immersed in 50% silver nitrate solution. The specimens then were sectioned and evaluated on degree of dye penetration. Results: the results were evaluated using the nonparametric Kruskall-Wallis test, which showed a statistically significant difference between groups G1 and G4, G2 and G4, and G3 and G4. Conclusions: None of the materials was able to eliminate the marginal microleakage at the cervical wall; the application of a low-viscosity resin composite combined with a compactable resin composite significantly decreased the microleakage.
Resumo:
Dentin hipersensitivity (DH) is a relatively common clinical condition, especially in periodontal patients after treatment. In this study it was evaluated 28 teeth who presented dentin hypersensitivity. The teeth were subjected to clinical and radiographic exams and were divided into groups following the treatment and the time of examination after application proposed: GI: PO 3% (Potassium Oxalate-group control)/Baseline; GII: PO 3%/3 days after first session; GIII: PO 3%/6 days; GIV: PO 3%/30 days; GV: PO 3%/60 days; GVI: PO 3%/90 days; GVII: Laser (Low-level diode laser with 110 mW/cm(2))/Baseline; GVIII: Laser/7 days after first session; GIX: Laser/14 days; GX: Laser/30 days; GXI: Laser/60 days; and GXII: Laser/90 days. The groups I-VI, the teeth were subjected to 3 applications (GI-GIII) of desensitizing agent at regular intervals of seven days. The Groups VII-XI, each tooth was subjected to three applications (GVII GIX) in three different points (mesial, meddle and distal surfaces) with an interval of 72 h. The time of application in each point was of 33 s and the patients from both groups were followed up to 90 days. The nonparametric test Friedman (alpha = 0.05) was applied and the test of Mann Whitney (alpha = 0.05) was used to compare the time of examination between groups. The application of Laser was effective 6 days after first session and to PO was 30 days. It was observed that both treatments were effective for the reduction of dentin hypersensitivity, however the laser presented better effectiveness.
Resumo:
Some photosensitizers (PSs) used for PACT (Antimicrobial Photodynamic Therapy) show an affinity for bacterial walls and can be photo-activated to cause the desired damage. However, on dentine bacterias may be less susceptible to PACT as a result of limited penetration of the PS. The aim of this study was to evaluate the diffusion of one PS based on hematoporphyrin on dentine structures. Twelve bovine incisors were used. Class III cavities (3 x 3 x 1 mm) were prepared on the mesial or distal surfaces using a diamond bur. Photogem (R) solution at 1 mg/mL (10 uL for each cavity) was used. The experimental Groups were divided according to thickness of dentine remaining and etched or no-etched before the PS application. The fluorescence excitation source was a VelScope (R) system. For image capture a scientific CCD color camera PixelFly (R) was coupled to VelScope. For image acquisition and processing, a computational routine was developed at Matlab (R). Fick's Law was used to obtain the average diffusion coefficient of PS. Differences were found between all Groups. The longitudinal temporal diffusion was influenced by the different times, thickness and acid etching.
Resumo:
Aim To evaluate differences between anatomic and radiographic measurements of root canal wall thickness (RCWT) after each root canal preparation stage during post placement.Methodology Twenty mandibular premolars with a single canal were decoronated and the roots embedded in resin using a teflon muffle. Roots were sectioned horizontally at a pre-established level and canals were prepared for post placement. Endodontic hand files were used for root canal preparation, followed by Gates Glidden drills and Peeso reamers. Standardized radiographs and photographs at pre-established measurement levels were taken before preparation, after root canal instrumentation, after Gates Glidden preparation and after Peeso enlargement. All images were digitized and RCWT at the mesial and distal walls measured (IMAGETOOL 3.0). Differences between radiographic and anatomic measurements were analysed with paired t-tests. ANOVA was used to compare the percentages of radiographic distortions.Results Regardless of the time-point evaluated, RCWT determined by radiographs were greater than the respective anatomic measurements (P < 0.05). The difference detected at each stage was similar and constant (P > 0.05).Conclusions Throughout preparation for post placement, radiographic images overestimated the RCWT by approximately 25%, regardless of the clinical stage evaluated.
Resumo:
The efferent ductules of the pigeon are localized in the epididymal region and are topographically divided into proximal and distal, both portions being lined with stereociliated pseudostratified epithelium. Transmission electron microscopy shows five distinct cell types
Resumo:
Principal cells of the ducts epididymis of the Mongolian gerbil showed ultrastructural characteristics of lining epithelium cells close related to processes of protein secretion, and transcytosis occurring between adjacent principal cells which were mainly verified in the initial segment. Principal cells also presented roles of fluid phase and adsorptive endocytoses, as well as autophagic and heterophagic lysosomal activities mainly observed in the caput epididymis. Columnar (principal) cells of the corpus epididymidis presented great number of variable vesicles and vacuoles distributed in all the cytoplasmic levels occurring a progressive coalescence pattern among them, which help to guarantee formation of cytoplasmic channels for fluid phase transport between the tubular lumen and epididymal interstitium. Clear cells were presented in the initial segment and predominately in the cauda epididymis epithelium of the gerbil and showed marked ultrastructural characteristics of endocytosis activities occurrence, perhaps directly related to the turnover of fluid phase of spermatozoa stored into the lumen of the distal tail. Other epididymal epithelium cells were verified and described such as basal, halo, apical and dark cells, but they did not presented special ultrastructural features. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)