995 resultados para ABSOLUTE RATES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present theoretical delay times and rates of thermonuclear explosions that are thought to produce Type Ia supernovae (SNe Ia), including the double-detonation sub-Chandrasekhar mass model, using the population synthesis binary evolution code startrack. If detonations of sub-Chandrasekhar mass carbon-oxygen white dwarfs following a detonation in an accumulated layer of helium on the white dwarf's surface ('double-detonation' models) are able to produce thermonuclear explosions which are characteristically similar to those of SNe Ia, then these sub-Chandrasekhar mass explosions may account for at least some substantial fraction of the observed SN Ia rate. Regardless of whether all double-detonations look like 'normal' SNe Ia, in any case the explosions are expected to be bright and thus potentially detectable. Additionally, we find that the delay time distribution of double-detonation sub-Chandrasekhar mass SNe Ia can be divided into two distinct formation channels: the 'prompt' helium-star channel with delay times

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of photon frequency redistribution by line branching on mass-loss rates for hot luminous stars is investigated. Monte Carlo simulations are carried out for a range of OB star models which show that previous mass-loss calculations which neglect non-resonance line scattering overestimate mass-loss rates for luminous O stars by ~20 per cent. For luminous B stars the effect is somewhat larger, typically ~50 per cent. A Wolf-Rayet star model is used to investigate line branching in the strong wind limit. In this case the effect of line branching is much greater, giving mass-loss rates that are smaller by a factor ~3 from computations which neglect branching.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. From the mid-1980s to mid-1990s, the WHO MONICA Project monitored coronary events and classic risk factors for coronary heart disease (CHD) in 38 populations from 21 countries. We assessed the extent to which changes in these risk factors explain the variation in the trends in coronary-event rates, across the populations. Methods. In men and women aged 35-64 years, non-fatal myocardial infarction and coronary deaths were registered continuously to assess trends in rates of coronary events. We carried out population surveys to estimate trends in risk factors. Trends in event rates were regressed on trends in risk score and in individual risk factors. Findings. Smoking rates decreased in most male populations but trends were mixed in women; mean blood pressures and cholesterol concentrations decreased, body-mass index increased, and overall risk scores and coronary-event rates decreased. The model of trends in 10-year coronary-event rates against risk scores and single risk factors showed a poor fit, but this was improved with a 4-year time lag for coronary events. The explanatory power of the analyses was limited by imprecision of the estimates and homogeneity of trends in the study populations. Interpretation. Changes in the classic risk factors seem to partly explain the variation in population trends in CHD. Residual variance is attributable to difficulties in measurement and analysis, including time lag, and to factors that were not included, such as medical interventions. The results support prevention policies based on the classic risk factors but suggest potential for prevention beyond these.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate and compare the outcome of functioning filtration surgery followed by cataract surgery with posterior intraocular lens implantation by both phacoemulsification and extracapsular cataract extraction (ECCE) techniques in glaucomatous eyes. PATIENTS AND METHODS: We retrospectively evaluated the clinical course of 77 eyes (68 patients) that after successful trabeculectomy, underwent cataract surgery by either phacoemulsification or ECCE techniques. We determined the frequency of partial and absolute failure following cataract surgery by either phacoemulsification or ECCE in eyes with functioning trabeculectomies. Partial failure of intraocular pressure (IOP), control after cataract extraction was defined as the need for an increased number of antiglaucoma medications or argon laser trabeculoplasty to maintain IOP =21mm Hg. Complete failure of IOP control after cataract surgery was defined as an IOP >21 mm Hg on at least two consecutive measurements one or more weeks apart or the performance of additional filtration surgery. Failure rates were calculated using the Kaplan-Meier actuarial method. Failure rates between phacoemulsification and ECCE subgroups were compared using the log rank test. RESULTS: The probability of partial failure by the third postoperative year after cataract surgery was 39.5% in the phacoemulsification subgroup and 37.3% in the ECCE subgroup. This small difference is not statistically significant (P = 0.48). The probability of complete failure by the fourth postoperative year after cataract surgery was 12.0% in the phacoemulsification subgroup and 12.5% in the ECCE subgroup. This difference is also not statistically significant (P = 0.77). At the 6-month follow-up visit, visual acuity of both groups improved one or more lines in 87.0% of patients, and worsened one or more lines in 3.9% of patients. Sixty-one percent achieved visual acuity of 20/40 or better. The most frequent complication was posterior capsular opacification requiring laser capsulotomy that occurred in 31.2% of patients. CONCLUSION: Cataract extraction by either phacoemulsification or ECCE following trabeculectomy surgery may be associated with a partial loss of the previously functioning filter and the need for more antiglaucoma medications to control IOP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The answer to the question of what it means to say that a right is absolute is often taken for granted, yet still sparks doubt and scepticism. This article investigates absoluteness further, bringing rights theory and the judicial approach on an absolute right together. A theoretical framework is set up that addresses two distinct but potentially related parameters of investigation: the first is what I have labelled the ‘applicability’ criterion, which looks at whether and when the applicability of the standard referred to as absolute can be displaced, in other words whether other considerations can justify its infringement; the second parameter, which I have labelled the ‘specification’ criterion, explores the degree to which and bases on which the content of the standard characterised as absolute is specified. This theoretical framework is then used to assess key principles and issues that arise in the Strasbourg Court’s approach to Article 3. It is suggested that this analysis allows us to explore both the distinction and the interplay between the two parameters in the judicial interpretation of the right and that appreciating the significance of this is fundamental to the understanding of and discourse on the concept of an absolute right.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential that laser based particle accelerators offer to solve sizing and cost issues arising with conventional proton therapy has generated great interest in the understanding and development of laser ion acceleration, and in investigating the radiobiological effects induced by laser accelerated ions. Laser-driven ions are produced in bursts of ultra-short duration resulting in ultra-high dose rates, and an investigation at Queen's University Belfast was carried out to investigate this virtually unexplored regime of cell rdaiobiology. This employed the TARANIS terawatt laser producing protons in the MeV range for proton irradiation, with dose rates exceeding 10 Gys on a single exposure. A clonogenic assay was implemented to analyse the biological effect of proton irradiation on V79 cells, which, when compared to data obtained with the same cell line irradiated with conventionally accelerated protons, was found to show no significant difference. A Relative Biological effectiveness of 1.4±0.2 at 10 % Survival Fraction was estimated from a comparison with a 225 kVp X-ray source. © 2013 SPIE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evidence is presented from three estuarine tide gauges located in the
Sundarban area of southwest Bangladesh of relative sea level rise
substantially in excess of the generally accepted rates from altimetry, as
well as previous tide-gauge analyses. It is proposed that the difference
arises from the use of relative mean sea level (RMSL) to characterise the
present and future coastal flood hazard, since RMSL can be misleading in
estuaries in which tidal range is changing. Three tide gauges, one located in
the uninhabited mangrove forested area (Sundarban) of southwest
Bangladesh, the others in the densely populated polder zone north of the
present Sundarban, show rates of increase in RMSL ranging from 2.8 mm
a-1 to 8.8 mm a-1. However, these trends in RMSL disguise the fact that high
water levels in the polder zone have been increasing at an average rate of
15.9 mm a-1 and a maximum of 17.2 mm a-1. In an area experiencing tidal
range amplification, RMSL will always underestimate the rise in high water
levels; consequently, as an alternative to RMSL, the use of trends in high
water maxima or ‘Effective Sea Level Rise’ (ESLR) is adopted as a more
strategic parameter to characterise the flooding hazard potential. The rate
of increase in ESLR is shown to be due to a combination of deltaic
subsidence, including sediment compaction, and eustatic sea level rise, but
principally as a result of increased tidal range in estuary channels recently
constricted by embankments. These increases in ESLR have been partially
offset by decreases in fresh water discharge in those estuaries connected
to the Ganges. The recognition of increases of the effective sea level in the
Bangladesh Sundarban, which are substantially greater than increases in
mean sea level, is of the utmost importance to flood management in this
low-lying and densely populated area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Achalasia is a neurodegenerative motility disorder of the oesophagus resulting in deranged oesophageal peristalsis and loss of lower oesophageal sphincter function. Historically, annual achalasia incidence rates were believed to be low, approximately 0.5-1.2 per 100000. More recent reports suggest that annual incidence rates have risen to 1.6 per 100000 in some populations. The aetiology of achalasia is still unclear but is likely to be multi-factorial. Suggested causes include environmental or viral exposures resulting in inflammation of the oesophageal myenteric plexus, which elicits an autoimmune response. Risk of achalasia may be elevated in a sub-group of genetically susceptible people. Improvement in the diagnosis of achalasia, through the introduction of high resolution manometry with pressure topography plotting, has resulted in the development of a novel classification system for achalasia. This classification system can evaluate patient prognosis and predict responsiveness to treatment. There is currently much debate over whether pneumatic dilatation is a superior method compared to the Heller's myotomy procedure in the treatment of achalasia. A recent comparative study found equal efficacy, suggesting that patient preference and local expertise should guide the choice. Although achalasia is a relatively rare condition, it carries a risk of complications, including aspiration pneumonia and oesophageal cancer. The risk of both squamous cell carcinoma and adenocarcinoma of the oesophagus is believed to be significantly increased in patients with achalasia, however the absolute excess risk is small. Therefore, it is currently unknown whether a surveillance programme in achalasia patients would be effective or cost-effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: High local control rates are achieved in stage I lung cancer using stereotactic ablative radiotherapy. Target delineation is commonly based on four-dimensional computed tomography (CT) scans. Target volumes defined by positron emission tomography/computed tomography (PET/CT) are compared with those defined by four-dimensional CT and conventional ('three-dimensional') F-fluorodeoxyglucose (F-FDG) PET/CT. Materials and methods: For 16 stage I non-small cell lung cancer tumours, six approaches for deriving PET target volumes were evaluated: manual contouring, standardised uptake value (SUV) absolute threshold of 2.5, 35% of maximum SUV (35%SUV), 41% of SUV (41%SUV) and two different source to background ratio techniques (SBR-1 and SBR-2). PET-derived target volumes were compared with the internal target volume (ITV) from the modified maximum intensity projection (MIP ITV). Volumetric and positional correlation was assessed using the Dice similarity coefficient (DSC). Results: PET-based target volumes did not correspond to four-dimensional CT-based target volumes. The mean DSC relative to MIP ITV were: PET manual = 0.64, SUV2.5 = 0.64, 35%SUV = 0.63, 41%SUV = 0.57. SBR-1 = 0.52, SBR-2 = 0.49. PET-based target volumes were smaller than corresponding MIP ITVs. Conclusions: Conventional three-dimensional F-FDG PET-derived target volumes for lung stereotactic ablative radiotherapy did not correspond well with those derived from four-dimensional CT, including those in routine clinical use (MIP ITV). Caution is required in using three-dimensional PET for motion encompassing target volume delineation. © 2012 The Royal College of Radiologists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The dose delivery accuracy of 30 clinical step and shoot intensity modulated radiation therapy plans was investigated using the single integrated multileaf collimator controller of the Varian Truebeam linear accelerator (linac) (Varian Medical Systems, Palo Alto, CA) and compared with the dose delivery accuracy on a previous generation Varian 2100CD C-Series linac.

Methods and Materials: Ten prostate, 10 prostate and pelvic node, and 10 head-and-neck cases were investigated in this study. Dose delivery accuracy on each linac was assessed using Farmer ionization chamber point dose measurements, 2-dimensional planar ionization chamber array measurements, and the corresponding Varian dynamic log files. Absolute point dose measurements, fluence delivery accuracy, leaf position accuracy, and the overshoot effect were assessed for each plan.

Results: Absolute point dose delivery accuracy increased by 1.5% on the Truebeam compared with the 2100CD linac. No improvement in fluence delivery accuracy between the linacs, at a gamma criterion of 3%/3 mm was measured using the 2-dimensional ionization chamber array, with median (interquartile range) gamma passing rates of 98.99% (97.70%-99.72%) and 99.28% (98.26%-99.75%) for the Truebeam and 2100CD linacs, respectively. Varian log files also showed no improvement in fluence delivery between the linacs at 3%/3 mm, with median gamma passing rates of 99.97% (99.93%-99.99%) and 99.98% (99.94%-100%) for the Truebeam and 2100CD linacs, respectively. However, log files revealed improved leaf position accuracy and fluence delivery at 1%/1 mm criterion on the Truebeam (99.87%; 99.78%-99.94%) compared with the 2100CD linac (97.87%; 91.93%-99.49%). The overshoot effect, characterized on the 2100CD linac, was not observed on the Truebeam.

Conclusions: The integrated multileaf collimator controller on the Varian Truebeam improves clinical treatment delivery accuracy of step and shoot intensity modulated radiation therapy fields compared with delivery on a Varian C-series linac. © 2014.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: High local control rates are achieved in stage I lung cancer using
stereotactic ablative radiotherapy. Target delineation is commonly based on
four-dimensional computed tomography (CT) scans. Target volumes defined by
positron emission tomography/computed tomography (PET/CT) are compared with those defined by four-dimensional CT and conventional ('three-dimensional')
(18)F-fluorodeoxyglucose ((18)F-FDG) PET/CT.

MATERIALS AND METHODS: For 16 stage I non-small cell lung cancer tumours, six
approaches for deriving PET target volumes were evaluated: manual contouring,
standardised uptake value (SUV) absolute threshold of 2.5, 35% of maximum SUV
(35%SUV(MAX)), 41% of SUV(MAX) (41%SUV(MAX)) and two different source to
background ratio techniques (SBR-1 and SBR-2). PET-derived target volumes were compared with the internal target volume (ITV) from the modified maximum
intensity projection (MIP(MOD) ITV). Volumetric and positional correlation was
assessed using the Dice similarity coefficient (DSC).

RESULTS: PET-based target volumes did not correspond to four-dimensional CT-based target volumes. The mean DSC relative to MIP(MOD) ITV were: PET manual = 0.64, SUV2.5 = 0.64, 35%SUV(MAX) = 0.63, 41%SUV(MAX) = 0.57. SBR-1 = 0.52, SBR-2 =0.49. PET-based target volumes were smaller than corresponding MIP ITVs.

CONCLUSIONS: Conventional three-dimensional (18)F-FDG PET-derived target volumes for lung stereotactic ablative radiotherapy did not correspond well with those derived from four-dimensional CT, including those in routine clinical use
(MIP(MOD) ITV). Caution is required in using three-dimensional PET for motion
encompassing target volume delineation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recent decision of the European Court of Human Rights in Ahmad v UK dangerously undermines the well-established case law of the Court on counter-terrorism and non-refoulement towards torture, inhuman and degrading treatment or punishment. Although ostensibly rejecting the ‘relativist’ approach to Article 3 ECHR adopted by the House of Lords in Wellington v Secretary of State for the Home Department, the Court appeared to accept that what is a breach of Article 3 in a domestic context may not be a breach in an extradition or expulsion context. This statement is difficult to reconcile with the jurisprudence constante of the Court in the last fifteen years, according to which Article 3 ECHR is an absolute right in all its applications, including non-refoulement, regardless of who the potential victim of torture, inhuman or degrading treatment is, what she may have done, or where the treatment at issue would occur.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The incidence of nonmelanomatous skin cancer (NMSC) is substantially higher among renal transplant recipients (RTRs) than in the general population. With a growing RTR population, a robust method for monitoring skin cancer rates in this population is required.
Methods: A modeling approach was used to estimate the trends in NMSC rates that adjusted for changes in the RTR population (sex and age), calendar time, the duration of posttransplant follow-up, and background population NMSC incidence rates. RTR databases in both Northern Ireland (NI) and the Republic of Ireland (ROI) were linked to their respective cancer registries for diagnosis of NMSC, mainly squamous cell carcinoma (SCC) and basal cell carcinoma (BCC).
Results: RTRs in the ROI had three times the incidence (P<0.001) of NMSC compared with NI. There was a decline (P<0.001) in NMSC 10-year cumulative incidence rate in RTRs over the period 1994–2009, which was driven by reductions in both SCC and BCC incidence rates. Nevertheless, there was an increase in the incidence of NMSC with time since transplantation. The observed graft survival was higher in ROI than NI (P<0.05) from 1994–2004. The overall patient survival of RTRs was similar in NI and ROI.
Conclusion: Appropriate modeling of incidence trends in NMSC among RTRs is a valuable surveillance exercise for assessing the impact of change in clinical practices over time on the incidence rates of skin cancer in RTRs. It can form the basis of further research into unexplained regional variations in NMSC incidence.